• 제목/요약/키워드: Ventilation design

검색결과 689건 처리시간 0.027초

Effective Local Exhaust Ventilation on Cooking Fumes of Seasoned Meats

  • Byeong Kyu Lee;Mic
    • 한국환경과학회지
    • /
    • 제2권1호
    • /
    • pp.49-56
    • /
    • 1993
  • This study identified the fumes produced from the cooking of the seasoned meats containing various condiments such as garlic, onion, pepper, soy sauce, and sesame oil. Concentrations, at the breathing zone of the cook, of volatile organic compounds (VOCs) and aldehydes included in the cooking fumes of seasoned meats were identified. Many chloro- and fluoro-aliphatic hydrocarbons, aromatic hydrocarbons, ketones, and aldehydes, which could be carcinogen suspecting chemicals, were producing from the cooking fumes of the seasoned meats. This study also identified the ventilation efficiencies of the cooking fumes of the six exhaust ventilation systems, which were widely being used in the general apartments, houses, and small-food factories. For a comparison of the ventilation efficiencies of the systems, acetaldehyde was chosen as a marker pollutant and its concentrations at the breathing zone of the cook were identified. The laboratory fume hood showed the best ventilation efficiency of the six ventilation systems studied, and then the lateral hood ventilation and the down draft ventilation followed the laboratory fume hood. Finally, this study identified that both a wall factor nearby pollutant sources and a distance factor between the hood face and pollutant sources should be also considered for an effective local exhaust ventilation system design.

  • PDF

Economical Ventilation Effectiveness to Reduce Hazardous Chemical Emissions for a Nail-Salon Worker

  • KWON, Woo-Taeg;JUNG, Min-Jae;LEE, Woo-Sik;KWON, Lee-Seung;SO, Young-Jin
    • 유통과학연구
    • /
    • 제17권7호
    • /
    • pp.65-76
    • /
    • 2019
  • Purpose - The purpose of this study is to investigate economical ventilation effectiveness to reduce hazardous materials exposure and damage of workers by analyzing exposure amount of noxious substances under various ventilation conditions of nail salon for indoor environments. Research design, data, and methodology - This study was carried out with cooperation of Nail shop located in SeongNam city to involve an analysis of the environmental impact indoor air quality, pollutant exposure and economical cost-effectiveness in the nail workplace. The hazardous substances were PM-10(Particulate Matter-10㎛), VOCs(Volatile Organic Compounds) and Formaldehyde, which are the major materials of nail workplace. Results - PM-10 is reduced by about 60% with air cleaner, forced artificial ventilation by 32%, and natural ventilation by about 12%. TVOCs and Formaldehyde showed similar efficiency (80~100%) after natural ventilation and ventilation after 60 minutes. The removal efficiencies of VOCs and formaldehyde were similar to those of natural ventilation and mechanical ventilation system. However, in case of dust, natural ventilation was reduced by artificial ventilation system due to inflow of external dust during natural ventilation. Conclusions - If the pollution degree of outdoor air is not high, air volume is high, and natural ventilation is performed when the air conditioning and heating system is not operated. Even at the end of the work, it keeps operating for 60 minutes to remove the pollutants generated. Results of this analysis demonstrated that the worker environment can be improved by adopting institutional legislation and guidelines for ventilation.

현대 건축공간에서 버네큘러 주거 냉방기법의 적용방법에 관한 연구 (A Study on the Application Method of Passive Cooling Technology in Contemporary Architecture)

  • 윤재영;허용석;허범팔
    • 한국실내디자인학회논문집
    • /
    • 제19권3호
    • /
    • pp.22-29
    • /
    • 2010
  • Recent days, transition to ecological thought is being accelerating by environmental impact with a sustainable development. This symptom is no exception in architecture area. So is vernacular design affecting on modern architecture in many ways in terms of economical aspect and eco-friendly environment as well. Natural energy like solar power, environment, and terrestrial heat that applied in vernacular architecture is also widely accepted in name of 'sustainable energy' of which a design applied with ventilation and airing of natural wind is very useful & pragmatic in terms of economical reason. Accordingly, this study examined a relation between vernacular architecture and natural wind and compared it with traditional type and its feature of ventilation & airing. Ventilation & airing applied in the past can be divided into three categories: methods by convection, natural element, and architectural type. All these methods gave some pleasant felling indoors when there were no artificial energies. Even in modern age, such a ventilation & airing is being used with traditional type in different variety of materials, and it will be developed with modern technology without any extra cost in terms of sustainable expansion, and opened for further researches.

보일러빌딩 내부 환기현상에 관한 수치적 연구 (Numerical Study on the Ventilation Effect in the Boiler Building)

  • 김철환;유근종;최훈기
    • 한국산업보건학회지
    • /
    • 제15권3호
    • /
    • pp.239-249
    • /
    • 2005
  • Ventilation effect is analyzed for boiler building with multiple heat sources. Air flow inside the boiler building is characterized as turbulent mixed convection. Analysis methodology is set up with two different $k-{\varepsilon}$ type models (standard $k-{\varepsilon}$, RNG $k-{\varepsilon}$). Two different cases with high and low outside temperature are analyzed. In case of high outside temperature condition, mixed convection is well realized inside the boiler building. With different upper louver opening rate, air flow is also well established and proper opening rate is found to meet design limit in case of low outside temperature condition. Difference of analysis results for two different turbulence models are not significant. Therefore, analysis methodology with simple $k-{\varepsilon}$ turbulence model is found to be reliable for the boiler building ventilation analysis. However, more simplified geometrical model is desired to expand its application.

재료품 품질의 변동이 필터 공기희석율 변동에 미치는 영향 (The Effects of Cigarette Component Variability on Filter Ventilation Variability by Monte Carlo Analysis.)

  • 김정열;김종열;신창호;정한주
    • 한국연초학회지
    • /
    • 제22권2호
    • /
    • pp.151-156
    • /
    • 2000
  • The variability of a ventilated filter cigarette depends on the details of its construction and on the variabilities of its components. Variations in filter ventilation arise from many sources, including variations in tobacco rod pressure drop, filter tip pressure drop, tipping paper permeability, and plugwrap permeability. To reduce the filter ventilation variability, the variability of filter ventilation levels in ventilated cigarettes is studied by Monte Carlo Analysis. For each trials a value is selected for tobacco rod pressure drop, filter tip pressure drop, tipping paper permeability, and plugwrap permeability. These values are selected randomly from a normal distribution based on the target and coefficient of variation for each input variable. The results of this analysis for filter ventilation variation suggest that the variations of filter ventilation are dependent on the details of cigarette designs studied and reducing the variability of any cigarette component will reduce filter ventilation variability. For typical cigarettes, variation in the permeability of tipping paper is usually the most significant contributor to filter ventilation variability. Results of a Monte Carlo Analysis could provide both general insights and specific practical guidance about the design of ventilated filter cigarettes.

  • PDF

자연 및 강제 배기시의 터널 내 연기거동에 관한 실험적 연구 (An Experimental Study of Smoke Movement in Tunnel Fire with Natural and Forced Ventilations)

  • 황철홍;유병훈;금성민;김정엽;신현준;이창언
    • 대한기계학회논문집B
    • /
    • 제29권6호
    • /
    • pp.711-721
    • /
    • 2005
  • In order to design of emergency ventilation systems, the smoke movements in tunnel fire with natural and forced ventilation were investigated. Reduced-scale experiments were carried out under the Froude scaling with novel fire source consisting many wicks. Temperature profiles were measured under the ceiling and vertical direction along the center of the tunnel and poisonous gases were measured at emergency exit point in the natural ventilation case. In forced ventilation, temperature profiles were measured with various flow rate to obtain critical velocity. The results showed that the interval of emergency exit having 225m was estimated reasonably through the measurements of temperature variation and poisonous gas in the natural ventilation. In the case of forced ventilation, the temperature distribution near fire source is remarkably different from that of natural ventilation. Also, the critical velocity to prevent upstream smoke flow has the range of 0.57m/s between 0.64m/s. Finally, it was also identified that although the increase of flow rate can suppress the backward flow of smoke to upstream direction, brings about the increase of flame intensity near stoichiometric fuel/air ratio.

굴착중인 장대터널내 최적의 환기시스템에 대한 연구 (The Study on Optimum Ventilation System during Long Tunnel Construction)

  • 오병화;임한욱
    • 화약ㆍ발파
    • /
    • 제24권2호
    • /
    • pp.9-22
    • /
    • 2006
  • 길이가 대단히 짧은 터널을 제외하고는 터널을 시공하는 경우 일반적으로 인위적인 환기시스템이 필요하다. 특히 장대터널의 경우 굴착 진행에 따라 적절한 환기시스템을 조합해서 사용하는 것이 효과적이다. 터널 연장이 4,580m인 능동터널은 본래 송기식을 사용하는 것으로 설계를 했지만, 굴착이 진행됨에 따라 송기식만으로 환기하는 데에는 한계가 예상되어 별도의 방식 검토를 수행하였다. 굴착중 터널의 소요환기량을 산정하고 이 소요환기량과 선택가능한 여러 가지 경우의 환기조합방식을 사례볕로 구성한 뒤 환기량과 유동성을 해석하고 비교함으로써 경제적으로도 우수한 최적의 환기조합안을 도출하였다. 환기시스템을 결정하기 위하여 각 환기시스템에 대한 경제적 효율성 평가를 수행하였다.

냉각 통풍홀 설계로 인한 견인 전동기 특성 및 제어 성능 영향 연구 (Effect on the Characteristics and Control Performance due to the Ventilation Hole Design of the Traction Motor)

  • 김기찬;이정일;권중록
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.801-803
    • /
    • 2001
  • On this study the motor design method with fairly good characteristics and control capability as well as cooling capability is presented with considering the magnetic effect due to ventilation hole, which is installed to prevent the temperature rise. When the input voltage rises due to critical variation in traction power supply system, the final ventilation hole is presented by checking the inductance parameter with clarifying the relation between saturation of the motor core and the ventilation hole.

  • PDF

멀티존 네트워크 모델을 이용한 주거용 건물의 환기량 분석 (Analysis of Ventilation Rates in Residential Buildings using a Multizone Network Model)

  • 차지형;박철훈;김영하;백창인;한화택
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.45-50
    • /
    • 2005
  • The supply outdoor airflow rates are calculated and analyzed using a multizone network model in a high-rise residential apartment. The system parameters include parameters related to weather conditions, building conditions, operation conditions, and facility conditions. Simulations are conducted according to the method of design of experiments and analysis of variance is conducted to investigate the effects of parameters on ventilation rate. A correlation equation is derived to predict ventilation rates of the building depending on the various parameters.

  • PDF

주택환기시스템의 덕트 Layout에 따른 T-Method의 풍량 예측 및 실험 (Air Flow Prediction and Experiment by T-Method According to Duct Layout on House Ventilation System)

  • 주성용;이정재
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.523-528
    • /
    • 2008
  • The accurate distribution of flow rate has been a very important part to control the air change rate since introduction of house ventilation system. An inappropriate selection of fan due to incorrect prediction of pressure loss in duct brings energy loss. In the previous study the pressure loss of general spiral duct was measured and database was constructed for finding correct loss factors in fitting upper stream. The purpose of this study is to compare and investigate the error range of flow rate by applying T-Method to bilateral symmetry and asymmetry layout of duct. The results of this study are as following. It is demanded to decide accurate size under duct design for house ventilation system. Because the small amount of Flow rate was considered at that time. The error range was 3.17% on case1 and 3.52% on case2. The error range difference was 0.35%.

  • PDF