• Title/Summary/Keyword: Ventilation Process

Search Result 232, Processing Time 0.023 seconds

The diagnosis of sleep related breathing disorders and polysomnography (수면호흡장애의 진단과 수면다원검사)

  • Park, Ji Woon
    • The Journal of the Korean dental association
    • /
    • v.53 no.4
    • /
    • pp.238-248
    • /
    • 2015
  • Sleep related breathing disorders(SRBDs) are a group of diseases accompanied by difficulties in respiration and ventilation during sleep. Central sleep apnea, obstructive sleep apnea(OSA), sleep-related hypoventilation, and hypoxemia disorder are included in this disease entity. OSA is known to be the most common SRBDs and studies show its significant correlation with general health problems including hypertension, arrhythmia, diabetes, and metabolic syndrome. The diagnostic process of OSA is composed of physical examinations of the head and neck area and also the oral cavity. Radiologic studies including cephalography, CT, MRI, and fluoroscopy assist in identifying the site of obstruction. However, polysomnography(PSG) is still considered the gold standard for the diagnosis of OSA since it offers both qualitative and quantitative recording of the events during a whole night's sleep. The dentist who is trained in sleep medicine can easily identify patients with the risk of OSA starting from simple questions and screening questionnaires. Diagnosis is the first step to treatment and considering the high rate of under-diagnosis for OSA the dentist may play a substantial role in the diagnosis and treatment of OSA which will eventually lead to the well-being of the patient as a whole person. So the objective of this article is to assist dental professionals in gaining knowledge and insight of the diagnostic measures for OSA including PSG.

A Study on the Cognitive Gap between Users and Experts in Elementary School Plans for Effective Decision-making Support (효율적(效率的) 의사결정(意思決定)을 위한 초등학교(初等學校) 계획(計劃)에서의 사용자(使用者)와 전문가(專門家)의 인식(認識) 차이(差異) 분석(分析))

  • Oh, Il-Ryong;Choi, Jae-Young;Lee, Dong-Joo;Ko, Eun-Hyung;Choi, Moo-Hyuck
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.12 no.6
    • /
    • pp.18-25
    • /
    • 2005
  • The purpose of this study is to investigate cognitive gap between users and architectural experts for architectural planning of elementary schools to support effective decision-makings. For this study, each architectural factor was selected from the journals published by Korean Institute of Education Facilities(KIEF) from 2000 to 2004. Among these factors, the priority planning factors were decided through Analytic Hierarchy Process(AHP). The results of this study showed users' emphasis on the amenities of physical environment such as orientation, ventilation, noise, view, but experts' preference on spatial composition of space and function such as orientation, circulation, zoning, parking lot, courtyard. This difference shows clear cognitive gaps between two groups and also suggests factors required to be considered to develop effective decision-making in elementary school planning.

Air Quality Changes in a Museum Damaged by a Tsunami - Whale and Sea Museum, Iwate, Japan -

  • MATSUI, Toshiya;KAWASAKI, Emi;Huttmann, Imme
    • Journal of Conservation Science
    • /
    • v.35 no.1
    • /
    • pp.51-60
    • /
    • 2019
  • This paper provides quantitative data that describes the evolution of the air quality in the Whale and Sea Museum, located in the Iwate prefecture, collected after the 2011 Great East Japan Earthquake and tsunami. The museum was damaged significantly by the disaster, and restoration works continued for over six years. The air quality in the temporary storage facility and museum was monitored during the rehabilitation process. Evaluation of air quality is carried out by gas chromatography- mass spectrometry, ion chromatography and high-performance liquid chromatography. The results showed that the characteristics of the chemical components differed depending on the measurement locations inside the building. The museum atmosphere tended to be alkaline as the airtightness increased because of the maintenance works at the entrance. It was also determined that it was necessary to study the intake/exhaust routes and to clean them according to the contamination degree. In Japan, there are recommended museum air quality standards for acetic acid, formic acid, alkali, and aldehydes. The results indicated that these standards should not be used as a reference for damaged museums. Furthermore, at the temporary storage facilities for to store the collections during the rehabilitation of the museum, solvents such as ethyl benzene, toluene, and xylene are initially abundant, although they can be reduced by ventilation, while other components such as 2E1H was confirmed in this case are likely to remain.

The Usefulness of Noninvasive Positive Pressure Ventilation in Patients With Acute Respiratory Failure after Extubation (기관내 관 제거 후 발생한 급성 호흡부전에서 비침습적 양압 환기법의 유용성)

  • Na, Joo-Ock;Lim, Chae-Man;Shim, Tae-Sun;Park, Joo-Hun;Lee, Ki-Man;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.3
    • /
    • pp.350-362
    • /
    • 1999
  • Background: Acute Respiratory failure which is developed after extubation in the weaning process from mechanical ventilation is an important cause of weaning failure. Once it was developed, endotracheal reintubation has been done for respiratory support. Noninvasive Positive Pressure Ventilation (NIPPV) has been used in the management of acute or chronic respiratory failure, as an alternative to endotracheal intubation, using via nasal or facial mask. In this study, we evaluated the usefulness of NIPPV as an alternative method of reintubation in patients who developed acute respiratory failure after extubation. Method: We retrospectively analyzed thirty one patients(eighteen males and thirteen females, mean ages $63\pm13.2$ years) who were developed acute respiratory failure within forty eight hours after extubation, or were extubated unintentionally at medical intensive care unit(MICU) of Asan Medical Center. NIPPV was applied to the patients. Ventilatory mode of NIPPV, level of ventilatory support and inspiratory oxygen concentration were adjusted according to the patient condition and results of blood gas analysis by the attending doctors at MICU. NIPPV was completely weaned when the patients maintained stable clinical condition under 8 $cmH_2O$ of pressure support level. Weaning success was defined as maintenance of stable spontaneous breathing more than forty eight hours after discontinuation of NIPPV. Respiratory rate, heart rate, arterial blood gas analysis, level of pressure support, and level of PEEP were monitored just before extubation, at thirty minutes, six hours, twenty four hours after initiation of NIPPV. They were also measured at just before weaning from NIPPV in success group, and just before reintubation in failure group. Results: NIPPV was successfully applied to thirty-one patients of thirty-two trials and one patient could not tolerated NIPPV longer than thirty minutes. Endotracheal reintubation was successfully obviated in fourteen patients (45%) among them. There was no difference in age, sex, APACHE III score on admission at MICU, duration of intubation, interval from extubation to initiation of NIPPV, baseline heart rate, respiratory rate, arterial blood gas, and $PaO_2/FiO_2$ between the success and the failure group. Heart rate and respiration rate were significantly decreased with increase $SaO_2$ after thirty minutes of NIPPV in both groups(p<0.05). However, in the patients of failure group, heart rate and respiratory rate were increased again with decrease in $SaO_2$ leading to endotracheal reintubation. The success rate of NIPPV treatment was significantly higher in the patients with COPD compared to other diseases(62% vs 39%) (p=0.007). The causes of failure were deterioration of arterial blood gas without aggravation of underlying disease(n=9), aggravation of undelying disease(n=5), mask intolerance(n=2), and retained airway secretion(n=l). Conclusion: NIPPV would be a useful therapeutic alternative which can avoid reintubation in patient who developed acute respiratory failure after extubation.

  • PDF

Studies on the aeration improvement of inner bottle(850ml) culture system during the mycelial culture of Pleurotus ostreatus (느타리의 균사 배양 중 배양기 내부 통기성 개선)

  • Yoo, Young-Jin;Shim, Kyu-Kwang;Koo, Chang-Duck;Kim, Myung-Koon
    • Journal of Mushroom
    • /
    • v.10 no.2
    • /
    • pp.57-62
    • /
    • 2012
  • The plastic culture bottle cap types and accumulated concentration of carbon dioxide, media humidity in the process of medium culture, chitin content and yield were observed in Pleurotus ostreatus 850ml bottle in Iksan, Jeollabuk-do, Korea, during 2011. The concentration of carbon dioxide in the process of medium culture was the highest after 8~9 days cultivation irrespective of cap sizes and types. The accumulated concentration of carbon dioxide in size cap of 29~41mm was 6.5~4.0% in the upper-under perforation hole of cap and 9.0~6.5% in the under perforation hole of cap. The upper-under 23~33mm perforation hole and under 29mm perforation hole of caps in the 850ml bottle were best condition for cultivation of mushroom and increased fruit body, 15.8~21.2% and 20%, respectively. However, the upper-under & under 41mm perforation hole of fruit body were decreased 60.7% and 23.6%, respectively. Also it was weak, lose vitality and the lower of biologically activity substance because the upper medium humidity was too dry.

Analysis of Microclimate in Apartment Complex by Age (시대별 아파트 단지의 미기후 분석)

  • Kim, Chul-Hee;Jung, Eung-Ho;Kim, Dae-Wuk;Cha, Jae-Gyu
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.11a
    • /
    • pp.104-108
    • /
    • 2009
  • Rapid urbanization resulted in expansion of urban area and increase of population bringing deepened housing shortage. Supply-oriented housing policy made apartment a representative residential space in Korea in spite of the short history of apartment. This study analyzed the shape and arrangement of main building by year and the microclimate in the complex depending on the number of floors. The purpose of this study was to present the basic data in developing apartment complex to solve problems like the stagnation of pollution source and the rise of temperature due to the declined ventilation in apartment complex, and the worsened urban heat island phenomenon due to the impeded flow of wind. This study rearranged the shape and arrangement of main building by year and the tendency of the number of floors by year in the process of change, by generalizing the process of change of apartment complex, a representative modern residential space through preliminary research. Based on it, 8 object lot by age was selected and simulated by using Envi-met. Simulation identified that the change of apartment complex takes place having a positive effect on microclimate in the apartment complex and the microclimate in the apartment complex is influenced a lot by the shape of complex. If in future apartment complex plan, a systematic legal criteria of design is made about the shape and arrangement of main building, it might have a positive effect on the improvement of microclimate in the apartment complex, a representative residential space in Korea.

  • PDF

Risk Assessment of Submerged Floating Tunnels based on Fuzzy AHP (퍼지 AHP를 이용한 수중터널의 재해위험도 분석)

  • Han, Sang-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.7
    • /
    • pp.3244-3251
    • /
    • 2012
  • In the construction and operation of large marine structure, hazard risk analysis is one of important factors. Therefore, this paper investigates the hazard risk indexes and evaluates the risk level in the construction and operation of SFT on the basis of expert survey and Fuzzy analytic hierarchy process. Hazard risk is divided into natural hazard risk (earthquake, typhoon, tsunami, and ice collision) and human factor hazard risk (fire, explosion, traffic accident, ship or submarine collision). Also, the influence of hazard risk indexes on SFT was evaluated in tunnel tube, supporting system, ventilation tower, foundation, and connection part. As the hazard risk level of SFT is compared with those of bridge, underwater tunnel, and immersed tunnel, the intrinsic risk level of SFT was evaluated. Tsunami and earthquake had higher risk level in natural hazard risk, and the risk levels of fire and explosion were higher in human factor hazard risk. Hazard risk level of SFT was 1.4 times higher than immersed tunnel, and 3.2 times higher than bridge.

A Prediction Model for TVOC and HCHO Emission of Paint Materials (페인트에서 방출되는 TVOC 및 HCHO 방출량 예측모델)

  • Kim, Hyung-Soo;Lee, Kyung-Hoi
    • KIEAE Journal
    • /
    • v.3 no.1
    • /
    • pp.13-20
    • /
    • 2003
  • It is highly recognized that there is need for protection against indoor air pollution, as we realize environmental pollution is growing, For example, in an indoor environment, a person spends more than 80 percent of their time inside the building. Thus, concern about indoor decoration materials is growing, since they cause pollution in the rooms of an apartment, as well as in offices. As the indoor decoration materials become more diverse and lusurious, so the effect of VOCs(Volatile Organic Compounds) and HCHO(Formaldehy) is growing. The indoor decoration materials cause the Sick Building Syndrome, such as headaches, dizziness, or lack of concentraion, and they in turn cause serious deterioration in people's health. In this study, I probed the status of the indoor air pollution and carried on an investigation and analysis about the prevention technique. In doing so, I performed experimental tests and an assessment of the indoor decoration materials of an apartment. I also examined elements of the emitted and the emission. Finally, I examined the character of emissions, by changing environmental conditions, such as the temperature, humidity, and ventilation. With respect to VOCs tests, I applied the method of solid state adsorption using the adsorptive tube, based on the measurement of the American EPA TO-17, ASTM 5116-97, and the measurement of the Japanese Wall Decoration Industrial Association. The tested sample was analyzed by High Performance Liquid Chromatography, after going through the process of dissolvent extraction. As subjects of the test, Paint were selected. The process of this test is as follows; first, I figured out the character of the emission, by measuring the emitted concentration of VOCs and HOHC from the indoor decoration materials of an apartment. Second, I made a small-scale chamber and the test was processed in the chamber in order to suggest an environment-friendly prediction modlel development.

Study on Micro Dried Bio-potential Electrodes Using Conductive Epoxy on Textile Fabrics (전도성 에폭시를 이용한 직물 위에 구현된 건식 생체전위 전극의 연구)

  • Cha, Doo-Yeol;Jung, Jung-Mo;Kim, Deok-Su;Yang, Hee-Jun;Choi, Kyo-Sang;Choi, Jong-Myong;Chang, Sung-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.5
    • /
    • pp.367-372
    • /
    • 2013
  • In this paper, micro dried bio-potential electrodes are demonstrated for sEMG (surface ElectroMyoGraphic) signal measurement using conductive epoxy on the textile fabric. Micro dried bio-potential electrodes on the textile fabric substrate have several advantages over the conventional wet/dry electrodes such as good feeling of wearing, possibility of extended-wearing due to the good ventilation. Also these electrodes on the textile fabric can easily apply to the curved skin surface. These electrodes are fabricated by the screen-printing process with the size of $1mm{\times}10mm$ and the resultant resistance of these electrodes have the average value of $0.4{\Omega}$. The conventional silver chloride electrode shows the average value of $0.3{\Omega}$. However, the electrode on the textile fabric are able to measure the sEMG signal without feeling of difference and this electrode shows the lower resistance of $1.03{\Omega}$ than conventional silver chloride electrode with $2.8{\Omega}$ in the condition of the very sharp curve surface (the radius of curvature is 40 mm).

Factors affecting the degree of Satisfaction with Workers' Working Environment engaging in Painting Process (도장 근로자의 작업 환경 만족도에 영향을 미치는 요인)

  • Lim, Nam Gu;Roh, Jaehoon;Chang, Kyu Yeob;Song, Jae Suk;Won, Jong Uk;Kim, Chi Nyon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.9 no.1
    • /
    • pp.73-86
    • /
    • 1999
  • This study was performed to find out factors affecting degree of satisfaction with workers' working environment. The study subjects were 165 workers who were working at painting process of twelve furniture manufacturing factories in Incheon area. We used self-administered questionnaire containing general characteristics, working conditions, the degree of satisfaction with working environment, and the degree of satisfaction with working condition. In addition, we measured the exposure levels of occupational hazardous agents. The results were as follows; 1. Correlations between the degree of satisfaction with workers' working environment and the measured of occupational hazardous agents did not affect the degree of satisfaction with workers' working environment. 2. Factors affecting the degree of satisfaction with workers' working environment were not the exposure levels of occupational hazardous agents, but the degree of satisfaction with working condition, size of industry, health status, and types of ventilation system. As the degree of satisfaction with working condition was increased, the degree of satisfaction with working environment was increased. Also, for the workers who had good health status, the degree of satisfaction with work environment was appeared to be high. To increase the degree of satisfaction, with workers' working environment, firstly, effective work management and production control are required. Also, the worker's effort to negotiate continuously with top manager on improving working conditions is required. Secondly, developing heath promotion program to be appropriate for the characteristics of worksite is required. Moreover, leading worker's participation in health promotion program is very important to increase the degree of satisfaction with workers' working environment.

  • PDF