• 제목/요약/키워드: Ventilation Process

검색결과 232건 처리시간 0.025초

에너지 효율 향상을 위한 열전소자를 이용한 흡·탈착 시스템 개발 연구 (A Study on the Development of Adsorption-Desorption Systems Using Thermoelectric Devices for Improved Energy Efficiency)

  • 유직수
    • 한국산업융합학회 논문집
    • /
    • 제27권4_2호
    • /
    • pp.981-989
    • /
    • 2024
  • In recent years, there has been a growing focus on preserving the global environment and utilizing resources efficiently. The significance of energy conservation has led to the development of systems that recycle waste heat from factories and use eco-friendly refrigerants. This study aims to enhance the performance of adsorption-desorption systems using thermoelectric devices, which are known for their ability to convert temperature differences into electrical energy. The research focuses on improving the efficiency of these systems by integrating thermoelectric modules to cool the adsorption side and heat the desorption side, thus enhancing overall system performance. The experiments utilized a typical thermoelectric device and silica gel as the adsorbent. Key experimental parameters included varying the inlet air temperature and relative humidity on the desorption side. The results indicated that increasing the relative humidity of the inlet air on the desorption side significantly enhanced the overall mass transfer coefficient while reducing the completion time of the process. Similarly, higher inlet air temperatures led to an increase in the mass transfer coefficient and a decrease in process completion time. These findings suggest that optimizing the operational conditions of thermoelectric devices can substantially improve the performance of adsorption-desorption systems, offering potential benefits for applications in ventilation systems and other related fields.

환기가 제한된 두 개 격실 화재에서 FDS 검증분석 (Validation of FDS for Fire in Underventilated Condition with Two rooms)

  • 배용범;금오현;김윤일;류수현;김위경;박종석
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.438-443
    • /
    • 2008
  • Fire model shall be verified and validated to reliably show the predictive capabilities for a specific use. In the process of model verification and validation, both the acceptable uses and limitation of fire model are established. In this study, the results of FDS simulation are compared with the data of PRISME experiment such as temperature, heat release rate, heat flux, product concentrations in the under-ventilated two-room condition. Furthermore, the sensitivity of FDS under ventilation condition changes are evaluated. FDS provide the reliable prediction for under-ventilated two-room fire scenario with slightly deviation.

  • PDF

주거겸용 오피스텔의 실내공기환경 개선방안;실내공기환경에 대한 거주자의 의견과 요구사항을 중심으로 (The Improvement Plan for IAQ of the Combined Officetel and Residence;Focused on the Demands and the Opinions of Residents)

  • 장하나;권오정;김진영
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2006년도 추계학술발표대회 논문집
    • /
    • pp.377-381
    • /
    • 2006
  • The purpose of this study was to suggest the improvement plan for IAQ of the combined officetel and residence through analyzing demands, satisfaction, subjective symptoms and device of residents. For this study, the data was collected from 110 residents by questionnaire survey and an experienced planner by interview. The result showed that the IAQ improvement of the combined officetel and residence was urgent. The educational program about maintenance of IAQ for residents was essentially needed. To recommend eco-friendly materials in process of construction wasimportant so as to take precaution against ‘sick building syndrome'. It was also necessary to improve on the size and shape of ventilation window.

  • PDF

홍콩 버비나하이츠(Verbena Heights) 주거단지의 특징에 관한 연구 (A Study on the Architectural Characteristics of ¡?Verbena Heights¡?Estate in Hong Kong)

  • 이재훈;김남응;김성화
    • 한국주거학회논문집
    • /
    • 제13권3호
    • /
    • pp.21-31
    • /
    • 2002
  • The purpose of this study is to find the architectural characteristics of Verbena Heights, super high-rise complex housing, which has been most highly evaluated as a new town development model in Hong Kong, as a successful case of new housing type and sustainable design. The analyzed features of Verbena Heights are as follows; 1) Formation of various open spaces by a creative layout. 2) Enhancement of natural ventilation and daylighting by a linear plan instead of conventional cruciform plans. 3) Applications of integrated facade design for noise mitigation and for sunlight shading. 4) Adoption of energy-efficient devices, use of recyclable materials, and improvement of livability by a sustainable design process. These architectural characteristics provide the high-density high-rise housing with more efficient and comfortable environments for residents. And it is proved that the sustainable design can enhance the quality of dwelling environment.

Automation of Solid-state Bioreactor for Oyster Mushroom Composting

  • Lee, Ho-Yong;Kim, Won-Rok;Min, Bong-Hee
    • Mycobiology
    • /
    • 제30권4호
    • /
    • pp.228-232
    • /
    • 2002
  • This study focused on the production of high quality compost for the growth of aero-thermophilic fungi, which has a promoting effect on the growth rate and production of oyster mushrooms. The automated solid-state bioreactor system was designed on the basis of a Three-Phase-One system, which controls the serial steps of prewetting, pasteurization and fermentation processes. High numbers of thermophilic fungi and bacteria were recovered from the mushroom composts prepared by this solid-state bioreactor. The rates of composting process were depended on physical as well as chemical factors. Among these factors, the parameters of moisture content and temperature were found to be particularly important. In our automated system, constant levels of moisture content, temperature and ventilation via mixing were provided by a centralized control apparatus including PLC, water tank and water jacket systems. These features induced higher microbiological activity of aero-thermophiles.

오피스텔의 실내공기환경 개선에 관한 연구 - 거주자의 의견과 요구사항을 중심으로 - (A Study on the Improvement for IAQ of the Officetel - Focused on Residents' Opinions and Demands -)

  • 장하나;김진영;권오정
    • 한국주거학회논문집
    • /
    • 제18권1호
    • /
    • pp.123-129
    • /
    • 2007
  • The purpose of this study was to suggest the idea for IAQ improvement of the of officetel which is used by fully or partly residential space. The data was collected from 110 residents by questionnaire survey and an experienced architect by personal interview. The results showed that the IAQ improvement of the officetel with residential usage and residence was urgent. The educational program about maintenance of IAQ for residents was essentially needed. To recommend eco-friendly materials in process of construction was important so as to take precaution against 'sick building syndrome'. It was also necessary to improve on the size, shape, and location of ventilation window.

An Enhanced Technologies of Intelligent HVAC PID Controller by Parameter Tuning based on Machine Learning

  • Kim, Jee Hyun;Cho, Young Im
    • 한국컴퓨터정보학회논문지
    • /
    • 제22권12호
    • /
    • pp.27-34
    • /
    • 2017
  • Design of an intelligent controller for efficient control in smart building is one of the effective technologies to reduce energy consumption by reducing response time with keeping comfortable level for inhabitants. In this paper, we focus on how to find major parameters in order to enhance the ability of HVAC(heating, ventilation, air conditioning) PID controller. For the purpose of that, we use machine learning technologies for tuning HVAC devices. We show the simulation results to illustrate the behavioral relation of whole system and each control parameter while learning process.

Earthquake performance of FRP retrofitting of short columns around band-type windows

  • Kocak, Ali
    • Structural Engineering and Mechanics
    • /
    • 제53권1호
    • /
    • pp.1-16
    • /
    • 2015
  • Due to design codes and regulations and the variety of building plans in Turkey, it is very often seen that band-type windows are left for ventilation and lightening of the basements of buildings which are used for various purposes such as workplaces and storage. Therefore when the necessary support measures cannot be given, short columns are subjected to very high shear forces and so damage occurs. One of the precautions to avoid the damage of short column mechanisms in buildings where band-type windows are in the basement is to strengthen the short columns with fiber reinforced polymer (FRP). In this study, the effect of the FRP retrofitting process of the short columns around band-windowed structures, which are found especially in basement areas, is analyzed in accordance with Turkish Seismic Code 2007 (TSC 2007). Three different models which are bare frame, frame with short columns and retrofitted short columns with FRP, are created and analyzed according to TSC 2007 performance analysis methods to understand the effects of band windows in basements and the effect of FRP retrofitting.

Video-Assisted Thoracic Surgery Thymectomy: Subxiphoid Approach

  • Cho, Sukki
    • Journal of Chest Surgery
    • /
    • 제54권4호
    • /
    • pp.314-318
    • /
    • 2021
  • In this paper, I present the technique of subxiphoid single-port video-assisted thoracic surgery (VATS) thymectomy for thoracic surgeons to perform this procedure safely. This procedure is indicated for all anterior mediastinal masses and may be extended to lung cancer. The patient is placed in the lithotomy position, and the operator should be on the midline. Below the xiphoid process, a skin incision is made 4-5 cm horizontally at a single thumb's width down. Under two-lung ventilation, CO2 is insufflated, maintaining 10 mm Hg. The fat tissue and thymic tissue are all resected from the sternum and pericardium between both phrenic nerves using an articulated grasper and an energy device. After retrieval of the mass with a wrap bag, a Jackson-Pratt drain is inserted instead of a chest tube. One of the advantages of this procedure is less postoperative pain than intercostal VATS. The subxiphoid approach can be used for bilateral pneumothorax, bilateral pulmonary metastasectomy, and simple lobectomy for both upper lobes and the right middle lobe.

An Overview of Biopulping Research: Discovery and Engineering

  • Scott, Gary M.;Akhtar, Masood;Lentz, Michael J.;Horn, Eric;Swaney, Ross E.;Kirk, T.Kent
    • 펄프종이기술
    • /
    • 제30권4호
    • /
    • pp.18-27
    • /
    • 1998
  • Biopulping is defined as the treatment of wood chips with lignin-degrading fungi prior to pulping. Fungal pretreatment prior to mechanical pulping reduces electrical energy requirements during refining or increases mill throughput, improves paper strength, reduces the pitch content, and reduces the environmental impact of pulping. Our recent work involved scaling up the biopulping process towards the industrial level, investigating both the engineering and economic feasibility. We envision the process to be done in either a chip-pile or silo-based system for which several factors need to be considered: the degree of decontamination, a hospitable environment for the fungus, and the overall process economics. Currently, treatment of the chips with low-pressure steam is sufficient for decontamination and a simple, forced ventilation system maintains the proper temperature, humidity, and moisture conditions, thus promoting uniform growth of the fungus. The pilot-scale trial resulted in the successful treatment of 4 tons of wood chips (dry weight basis) with results comparable to those on a laboratory. Larger, 40-ton trials were also successful, with energy savings and paper properties comparable with the laboratory scale. The overall economics of the process also look very favorable and can result in significant annual savings to the mill. Although the current research has focused on biopulping for mechanical pulping, it is also beneficial for sulfite chemical pulping and some applications to recycled fiber have been investigated.

  • PDF