• 제목/요약/키워드: Ventilation Path

검색결과 22건 처리시간 0.027초

공동주택에 건강개념인 통기시스템에 관한 연구 - 공기순환과 필로티를 중심으로 - (A Study on the Air Ventilation System in Apartment Houses as a Health Concept - focused on the air ventilation and pilotis -)

  • 조철희;이특구
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제10권1호
    • /
    • pp.29-38
    • /
    • 2004
  • The purpose of this study is to analyze the air ventilation system in apartment houses focused on the air circulation and pilotis. The air ventilation system is used with the data which were obtained by the environmental health, urban climate, air pollution, ventilation path. The architectural element was pilotis concept connected with piloti ratio, piloti position and piloti type. The summaries of this study were as follows; 1) the well-being apartment concept, 2) the heat island phenomenon, 3) the oxygen density of air, 4) the definition of ventilation path, 5) the pilotis connected with residential environment improvement. In addition, the detailded case study to the air ventilation system in apartment houses be needed.

  • PDF

창호일체형 환기장치의 소음분석 및 저감방안 (Noise Analysis and Reduction Methods of the All-in One Window Ventilation System)

  • 박찬재;한찬훈
    • 한국음향학회지
    • /
    • 제32권1호
    • /
    • pp.43-55
    • /
    • 2013
  • 최근 창호의 창틀에 폐열회수장치를 삽입한 일체형 환기장치인 일명 "창호일체형 폐열회수 환기장치"를 개발됨으로써 창문을 열지 않고도 에너지 손실을 최소화하면서 실내외 공기를 교환할 수 있게 되었다. 그러나 이 장치의 작동시 기계소음과 공력소음이 발생하여 실제 주거시설에 적합하지 않은 면이 있다. 따라서 본 연구에서는 창호일체형 환기장치의 소음을 설치상태와 무향실에서 측정하고 소음의 발생 원인과 소음전달 취약부분을 분석하였다. 또한, 창호일체형 환기장치내의 차음재와 흡음재를 설치하여 소음을 제어하기 위한 대안을 제시하였다. 연구결과, 환기장치의 소음원은 블로워로 나타났으며 소음의 주된 누출 원인은 환기장치 구조체의 낮은 차음성능 때문이었음을 알 수 있었다. 또한 이를 제어하기 위하여 장치 내부에 고무시트 등의 차음재를 설치한 결과 폐열회수환기장치의 소음기준인 40 dBA 이하를 만족함을 알 수 있었다.

다연동 온실의 자연환기효율성 비교 분석 (Comparative Study on Efficiencies of Naturally-Ventilated Multi-Span Greenhouses in Korea)

  • 권순홍;정성원;권순구;박종민;최원식;김종순
    • 한국산업융합학회 논문집
    • /
    • 제20권1호
    • /
    • pp.8-18
    • /
    • 2017
  • This research analyzed the ventilation effect of the multi-span greenhouse based on the types of greenhouse structure, weather conditions, and locations inside the greenhouse. To compare and analyze the ventilation effects with different types of greenhouse, the uniform environmental conditions should be selected in advance. But these factors are not controlled and require tense many precision facilities and labor forces. Thus, the CFD simulation was used for the air stream to be analyzed qualitatively and quantitatively. In addition, for the ventilation effect analysis, the TGD (Tracer Gas Decay) was used to overcome the shortcomings of the current ventilation measurement method. The calculation error of ventilation rate using TGD was low (10.5%). Thus, the TGD is very effective in calculating the ventilation efficiency. The wind direction of 90 degrees showed the best ventilation effect. The ventilation rate also decreased along the air circulation path, and the rate was the lowest around the outlet. The computed fluid method (CFD) turned out to be a power tool for simulating flow behavior in greenhouse.

공동주택단지배치의 간극비와 바람장의 상관관계에 관한 연구 (A Study on Correlations of the Gap Ratio of Apartment Houses Arrangement and the Wind Field)

  • 문출성;오세규;조성우
    • KIEAE Journal
    • /
    • 제11권2호
    • /
    • pp.75-82
    • /
    • 2011
  • In Korea, the ratio of population in urban areas used to be only 50.1% in 1970, but with the value risen to 90.8% in 2009, urbanization is going on rapidly. Urbanization, which occurs by the rampantly planted buildings, has become major source of raising building density, changing wind direction and reducing wind amount, and such reductions are affecting even inside the building. In each year, among the total energy consumption in Korea, residential portion takes up significant ratio, and specifically the ratio of apartment house is shown to be highest. In order to solve such problem, many studies are being conducted for the improvement of natural ventilation performance. The natural ventilation performance of apartment house are significantly determined by the characteristics of external and internal structure, but in macroscopic perspective, the performance is established fundamentally by the layout characteristics of the main building of the apartment house in preparation for wind conditions. So far researches on raising the thermal comfort through elevation of ventilation performance have been conducted actively, but many of them propose only theoretical concepts deduced through wind path analysis, and do not include any indicator to measure ventilation performance simply only with area data from layout planning stage. Therefore, in this study, gap ratio a wind field measuring indicator was developed, and after the ventilation characteristics by layout types and main building uniformity were identified, the scope of gap ratio efficient for ventilation and that of uniformity were clarified, followed by verification through simulation.

엔진실 차폐 시스템의 냉각성능 개선을 위한 수치적 연구 (NUMERICAL STUDY FOR COOLING CAPACITY IMPROVEMENT OF ENGINE ROOM ENCLOSURE SYSTEM)

  • 배이석;유근종;최훈기
    • 한국전산유체공학회지
    • /
    • 제14권2호
    • /
    • pp.39-45
    • /
    • 2009
  • In engine room, proper enclosure system is preferable for reducing noise level but the enclosure system in the engine room causes bad influence on cooling performance due to poor ventilation. Cooling efficiency of the enclosure system can be improved by varying fan speed and proper flow path for ventilation. In this study, numerical analysis is performed to assess cooling effect of the enclosure system using finite volume method. The RNG k-$\varepsilon$ model is adopted for turbulence model along with heat exchanger model and porous media model for heat exchanger analysis, and moving reference frame model for rotational fan. Verification result shows reasonable agreement with experimental data. Analysis results show direct effect of velocity and temperature distribution on cooling ability in the enclosure system. Enclosure system of case B shows high heat transfer coefficient and has the smallest area ratio of opened flow passages which is good for noise level reduction.

관수방법, 관수회수 및 송풍처리에 따른 초화류의 생장에 미치는 영향 (Effects of Method, Number of Times for Spraying and! Ventilation Condition on the Growth in Greenhouse)

  • 민병로;김웅;이범선;이대원
    • 생물환경조절학회지
    • /
    • 제13권3호
    • /
    • pp.149-155
    • /
    • 2004
  • 본 연구에서는 주행경로의 설정 및 제어가 용이한 고정 경로 방식을 이용한 주행 시스템을 개발하여 온실의 형태, 고랑의 위치 등에 무관하게 자동관수 및 송풍장치에 따른 생육상태를 실험할 수 있는 다목적 자동작업시스템을 개발하였다. 이 시스템의 성능들을 알아보기 써해 초화류에 대하여 실험한 결과 다음과 같은 결과론 얻었다. 인력두상관수 처리구에서는 전반적으로 생육의 부진을 나타냈으며, 자동관수 처리 중 송풍을 하지 않은 무풍처리구치 경우, 초장 및 엽면적이 높은 것으로 나타났다. 초장의 억제는 저속과 고속송풍처리구에 있어 초장억제 효과가 유의성이 있게 나타났으며, 풍속이 빠를수록 초장억제효과가 높게 나타났다. 줄기의 지름은 송풍을 하지 않고, 자동관수 3회를 한 경우 줄기의 지름이 작은 것으로 나타났다. 엽수는 인력관수나 자동관수 2회 처리에 비하여 3회 처리가 더 많은 것으로 나타났다. 생육은 관수회수가 많을수록 생장량이 높게 나타났다.

관수회수 및 송풍처리가 과채류의 묘 생장에 미치는 영향 (Effects of Spray Times and Ventilation Method on the Seedling Growth of Fruit Vegetables)

  • 김창수;민병로;김웅;김동우;서광욱;이범선;이대원
    • 생물환경조절학회지
    • /
    • 제14권1호
    • /
    • pp.1-6
    • /
    • 2005
  • 본 연구에서는 주행경로의 설정 및 제어가 용이한 고정 경로 방식을 이용한 주행 시스템을 개발하여 온실의 형태, 고랑의 위치 등에 무관하게 자동관수 및 송풍장치에 따른 생육상태를 실험할 수 있는 다목적 자동작업시스템을 개발하였다. 이 시스템의 성능들을 알아보기 위해 과채류에 대하여 실험한 결과 다음과 같은 결과를 얻었다. 오이는 초장, 줄기 지름, 엽면적 및 줄기 한마디의 평균 길이에 있어서 고속송풍에 따른 억제효과가 나타났으나, 관수 회수에 따른 차이는 크지 않았다. 토마토는 송풍처리에 따라 송풍속도가 강할수록 초장이 억제되는 효과를 나타냈다. 줄기의 지름은 처리구간 큰 차이를 나타내지 않았다. 3회 관수처리구의 경우 송풍속도가 강할수록 줄기의 지름이 두꺼워지는 경향을 나타내었다. 엽면적은 대조구(Hand spray)에 비해 2회 관수처리구의 엽면적이 높게 나타났으며, 송풍속도에 따른 차이가 나타나지 않았다. 고추는 전체적으로 대조구에 비해 자동관수 처리구와 송풍처리구가 초장, 줄기의 지름, 엽면적 등이 낮게 나타났다.

냉기류를 이용하여 공동주택단지 내 지하주차장 오염농도를 저감하는 기후 디자인에 관한 연구 (A study on climate design using cold air flow to reduce air contaminant concentration of underground garage in the apartment complex)

  • 김태한;조경학;최지혜;김석철
    • KIEAE Journal
    • /
    • 제11권1호
    • /
    • pp.29-38
    • /
    • 2011
  • This study suggested practical application of climate design on apartment complex with the focus on the use of Cold Air Flow and green building design method. The domestic research on the wind path analysis has been associated since the early 21th century in urban planning and site planning, this initiative study aimed to mitigate the urban heat island effect and to promote the sustainable urban development. It is, however, mostly focused on the flow analysis and heat flow in the urban context, due to the poor application of the wind path analysis in actual planning and design. Special attention is paid to the possibilities of identifying and developing the application methods in relation to Cold Air Flow and building design. This study examined these relations and suggested some trenchant approach to a more comprehensive and efficient use of the wind flow analysis in climate design.

해군 함정에서의 EMP 영향 및 대책 (Electromagnetic Pulse Coupling into Naval Warship and Protective Measures)

  • 양진호;남상욱
    • 한국전자파학회논문지
    • /
    • 제25권4호
    • /
    • pp.426-433
    • /
    • 2014
  • 고고도 핵폭발로 인해 고고도 전자기 펄스(HEMP)가 발생한다. 본 논문에서는 Bell 연구소와 IEC 61000-2-9 기준에 제시된 HEMP 파형이 해군 함정의 복사성 결합 통로와 전도성 결합 통로를 통해 입사할 때 침투하는 침투 전계 특성을 비교 검토하였다. 또한, 두 가지 종류의 결합에 대한 효과를 분석하고, 방호 대책을 제시하였다. 시뮬레이션 결과, IEC 61000-2-9 기준이 Bell 연구소의 기준보다 저주파수 대역을 제외하고 침투전계가 크므로 좀 더 엄격한 기준으로 볼 수 있고, 따라서 IEC 61000-2-9의 기준을 해군내 HEMP 기준으로 제시하였다. 최종적으로 HEMP 방호 대책으로 차폐 코팅, 허니컴 통풍구, TVS 소자 등을 이용하여 미국방부 기준에 부합하는 것을 확인하였다.

통풍식 자동차 디스크 브레이크의 열탄성 불안정성에 관한 실험적 연구 (An Experimental Study of Thermoelastic Instability in Automotive Ventilated Disk Brake)

  • 조병수;백병준;박복춘;김종환;김완두
    • Tribology and Lubricants
    • /
    • 제13권4호
    • /
    • pp.10-17
    • /
    • 1997
  • The present study describes an experimental investigation of temperature fluctuations associated with thermal instability. Surface temperatures of brake disk and pad were monitered at various locations in a caliper type brake system during drag braking conditions. It was found that the thermal instability appeared in pad more seriously than in disk. The temperatures at various circumferential positions fluctuate synchronously, whereas the center temperature fluctuates with 180$^{\circ}$ phase difference from the outer and inner radius temperatures. The temperature and amplitude of the temperature perturbations are increased due to the increase of contact area in the center location. It was also found that the thermal instability was dominantly determined by the increase of rotation speed and pressure. And the modification of ventilation path could retard the onset of thermal instability.