• Title/Summary/Keyword: Ventilation Fan

Search Result 279, Processing Time 0.02 seconds

Prediction of Cooling Performance for Indirect Evaporative Cooling System Using Danpla Sheet (단프라시트를 적용한 간접식 증발냉각 장치의 냉각 성능 예측)

  • Kim, Myung-Ho;Kim, Byoung Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.892-897
    • /
    • 2020
  • Previous plastic heat exchangers are expensive because the mold must be newly manufactured depending on the air conditioning space. On the other hand, danpla is so thin that the heat exchange performance is excellent. Moreover, danpla can be used easily in ventilation systems in view of fabrication. This study proposes correlations for the cooling performance of an indirect evaporative cooling system. The experimental apparatus consisted of a heat exchanger, spray nozzle, fan, thermostat, pump, and measuring sensors for temperature, humidity, and airflow rate. The results showed that the effectiveness decreased gradually as the airflow rate increased. In addition, there was an optimal condition in terms of effectiveness. The performance prediction correlations were determined using the experimental data from various conditions. The proposed correlations showed performance accuracies within 4 % error.

Prevention of Barn Rot during Curing of Burley Tobacco. II. Effect of Curing Conditions and Supplemental Heat. (버어리종 잎담배 건조시 부패방지 II. 건조조건과 보조화력의 영향)

  • 배성국;임해건;한철수
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.34 no.4
    • /
    • pp.331-334
    • /
    • 1989
  • This studies were carried out to investigate the effects of the management of curing barn and the use of supplemental heat on prevention of barn rot during the rainy season. The managemental methods of curing barn were combined with hanging spaces ranged from 15cm to 30cm and ventilating conditions. The supplemental heat was applied with oil burner and oil fan heater. Barn rot was reduced in the wider hanging spaces, and the effects of hanging spaces was larger with ventilating during curing. Barn rot decreased by ventilating condition than non-ventilation. The use of supplemental heat dropped to lower relative humidity in curing barn. Supplemental heat and forced-air movement greatly reduced barn rot in comparison with tobacco cured under natural conditions.

  • PDF

The Study on the Health of Aroma Therapeutist (아로마 시술자들의 건강실태에 관한 연구)

  • Kim, Mi-Ok;Suk, Kui-Duk
    • Korean Journal of Human Ecology
    • /
    • v.17 no.1
    • /
    • pp.171-179
    • /
    • 2008
  • This study focuses on 130 estheticians currently working in and around Daegu and Gyeongbuk region, in order to find out the current state of affairs and side effects related to aromatherapy. This paper is based on a survey. SPSS win 11.0 program was used for the analysis of descriptive statistics and independent t-test. According to the result of analysis, about 33% of the estheticians have had allergy experience. And in terms of installation of an air ventilation fan, which is the most important facility in an treatment room, more than half (50.8%) replied they did not have one. There was a statistically significant difference between those estheticians suffering from allergy and those who did not, in symptoms of stuffy nose/rhinitis (P<0.01) and dry skin/itchiness (P<0.5). (Allergy symptoms from the 33% of estheticians were limited to those which occurred after he or she began career) On work related symptoms, those who had work history at hospitals/clinics or apothecaries were compared. A statistically relevant difference was confirmed between those estheticians with therapy experience and those who had none, in all symptoms except headaches and drowsiness/weariness. In other words, there was difference in symptoms such as dryness of skin/itchiness (P<0.01), stuffy nose/rhinitis, dry throat, tension/nervousness, dizziness, tired eyes(P<0.5), nausea, having trouble with focusing, and fatigue(P<0.1). Those estheticians who had a history of treatment especially suffered most from dryness of skin and itchiness. The rate of regular check-ups and the use of masks, employed for self protection, was lower than average (amounting to 5 points), with the use of masks especially having the lowest average (1.7) points.

The Estimation and Application of Optimum Design Variables for Road Tunnel Ventilation System Based on Statistical Analysis (통계적 분석을 이용한 터널 환기시스템 적정설계변수의 산정 및 적용에 관한 연구)

  • 이보영;유용호;김진
    • Tunnel and Underground Space
    • /
    • v.14 no.5
    • /
    • pp.373-380
    • /
    • 2004
  • In this study, the emission rate of pollutant was modified according to the published standards, and the distribution of pollutant concentration was analyzed for each vehicle velocity. This modified emission rate was applied to a model tunnel and it was proved that the required air quantity was reduced to 49%, compared to the PIARC method. From the simulation result, it was proved by using statistics that the most sensitive factor among them is the friction coefficient and it was modified to the value in the range of 0.018 to 0.021. It is also expected that the required air quantity can be decreased form 14.4% to 19.2% according as the coefficient is applied to the domestic model tunnels. In conclusion, it is proposed that the number of jet fans can be reduced and the annual operating cost can be curtailed as well.

A Numerical Study on the Performance Improvement of Kitchen Range Hood by Air Induction and Air Curtain (유도공기 및 에어커튼을 이용한 주방 레인지후드 성능 개선에 관한 수치모사)

  • Sohn, Deok-Young;Lim, Ji-Hong;Choi, Yun-Ho;Park, Jae-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.4
    • /
    • pp.321-327
    • /
    • 2007
  • In an apartment house that is generally air-tight and well insulated, the combustion gas from cooking devices is the major source of air pollution in the kitchen. It spreads throughout the house affecting the overall Indoor all quality. In this study, the performance of the kitchen range hood which employs air induction and air curtain was investigated by numerical simulation. The results are compared with that of two other kitchen range hoods which are in general use. The two general types of range hoods considered in the present calculations are box and plate type range hoods. The former has a large capture space between the filter and suction duct, while the latter has little. It was found that the capture efficiency of the kitchen range hood with air induction and air curtain Is higher than that of the general types of range hoods by 20% approximately The reason may be because the air induction and the air curtain block the air stream escaping from the front and the side part of range hoods effectively and because an additional fan for air induction and air curtain increases suction flow rates.

Indoor distribution characteristics of airborne bacteria in pig buildings as influenced by season and housing type

  • Kim, Ki Youn;Ko, Han Jong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.5
    • /
    • pp.742-747
    • /
    • 2019
  • Objective: A concentration of airborne bacteria generated from swine houses is recognized to be relatively higher than other work places and it is essential to optimally manage it to prevent farmers' respiratory diseases. This study was conducted to assess the distribution characteristics of airborne bacteria in swine houses located at South Korea. Methods: A total 27 pig buildings of the enclosed type operated with mechanical ventilation system by a side wall fan and deep-pit manure system with slats were surveyed. Air samples were collected at 1.0 m above the middle floor in pig housing room. A six-stage viable particulate cascade impactor was used to identify the distribution of the sizes of particles in diameter. Results: Seasonal mean levels of airborne bacteria in the housing rooms of gestation/farrowing pigs, nursery pigs and growing/fattening pigs were 3,428(${\pm}1,244$) colony forming unit $(cfu)/m^3$, $8,325({\pm}3,209)cfu/m$, and $13,254({\pm}6,108)cfu/m^3$ for spring; $9,824({\pm}2,157)cfu/m^3$, $18,254({\pm}5,166)cfu/m^3$, and $24,088({\pm}9,274)cfu/m^3$ for summer; $1,707({\pm}957)cfu/m^3$, $4,258({\pm}1,438)cfu/m^3$, and $8,254({\pm}2,416)cfu/m^3$ for autumn; and $2,322({\pm}1,352)cfu/m^3$, $6,124({\pm}1,527)cfu/m^3$ and $12,470({\pm}4,869)cfu/m^3$ for winter, respectively. Conclusion: Concentrations of airborne bacteria according to pig housing type were highest in growing/fattening housing room followed by nursery housing room and gestation/farrowing housing room. In terms of seasonal aspect, the pig building showed the highest levels of airborne bacteria in summer followed by spring, winter and autumn. The respirable airborne bacteria which are ranged between 0.6 and $4.7{\mu}m$ accounted for approximately 60% compared to total airborne bacteria regardless of pig housing type.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

Dust Spatial Distribution and Emission of Tunnel Ventilated Windowless Broiler Building (터널환기 무창육계사의 분진크기별 분포와 배출농도에 관한 연구)

  • Choi, H.C.;Yeon, G.Y.;Spmg, J.I.;Kang, H.S.;Kwon, D.J.;Yoo, Y.H.;Yang, C.B.;Chun, S.S.;Kim, Y.K.
    • Journal of Animal Environmental Science
    • /
    • v.12 no.3
    • /
    • pp.115-122
    • /
    • 2006
  • This study investigated the spatial distribution of dust originating from tunnel-ventilated windowless broiler building measuring 12 m wide, 61 m long, with a side wall height of 3 m and a capacity of 16,982 birds. Dust concentrations in terms of total suspended particles (TSP), and particulate matter of sizes $10\;{\mu}m$(PM10), $2.5\;{\mu}m$(PM2.5), and $1\;{\mu}m(PM1)$ were measured at 30 minutes interval by using GRIMM Aerosol Monitor (GRIMM AEROSOL). The spatial distribution of dust showed the lower dust concentration in the inlet than in the outlet of the tunnel ventilation, and dust concentration decreasing as the dust size decreased, as follows: $317.9\;{\mu}g/m^3$ TSP; $74.7{\mu}m/m^3$ PM10; $9.7\;{\mu}g/m^3$ PM2.5; and $6.2\;{\mu}g/m^3$ PM1 in the inlet; and $2,678.5\;{\mu}g/m^3$ TSP; $555.5\;{\mu}g/m^3$ PM10; $33.3\;{\mu}g/m^3$ PM2.5; and $10.2\;{\mu}g/m^3$ PM1 in the outlet. The dust concentration emitted from the tunnel ventilated fan was $446.6\;{\mu}g/m^3$ TSP; $129.1\;{\mu}g/m^3$ PM10; $15.8\;{\mu}g/m^3$ PM2.5; and $6.1\;{\mu}g/m^3$ PM1 in the 3 meters from the fan and $25.1\;{\mu}g/m^3$ TSP; $8.8\;{\mu}g/m^3$ PM10; $5.6\;{\mu}g/m^3$ PM2.5; and $4.9\;{\mu}g/m^3$ PM1 in the 50 meters from the fan.

  • PDF

Effects of Tropical Climate on Reproduction of Cross- and Purebred Friesian Cattle in Northern Thailand

  • Pongpiachan, P.;Rodtian, P.;Ota, K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.7
    • /
    • pp.952-961
    • /
    • 2003
  • In the first part of the study, rates of estrus occurrence and success of A.I. service in the Thai-native and Friesian crossbred, and purebred Friesian cows fed in the National Dairy Training and Applied Research Institute in Chiang Mai, Thailand were traced monthly throughout a year. An electric fan and a water sprinkler cooled the stall for the purebred cows during the hot season (March-September). Both rates in pure Friesians were at their highest in the cold-dry season (October- February), but they decreased steadily during the hot-dry season (March-May) and were at their lowest in the hot-wet season (June-September). Seasonal change of a similar pattern was observed in the incidence of estrus, but not in the success rate of insemination in the crossbred cows. By the use of reproductive data, compiled in the same institute, on the 75 % cross- and purebred Friesian cows, and climatological data in Chiang Mai district, effects of ambient temperature and humidity on the reproductive traits of cows were examined by regression analysis in the second half of the study. Significant relationships in the crossbred, expressed by positive-linear and parabola regressions, were found between reproductive parameters such as days to the first estrus (DTFE), A.I. service (DTFAI), and conception, the number of A.I. services required for conception and some climatic factors. However, regarding this, no consistent or intelligible results were obtained in purebred cows, perhaps because electric fans and water sprinklers were used for this breed in the hot season. Among climatic factors examined, the minimum temperature (MINT) in early lactation affected reproductive activity most conspicuously. As the temperature during one or two months prior to the first estrus and A.I. service rose, DTFE and DTFAI steadily became longer, although, when MINT depleted below $17-18^{\circ}C$, the reproductive interval tended to be prolonged again on some occasions. The maximum temperature also affected DTFE and DTFAI, but only in limited conditions. The effect of humidity was not clear, although the inverse relationship between DTFE and minimum humidity during 2 months before the first estrus in the crossbred seemed to be significant. Failure to detect any definite effect of climate on the reproductive traits of pure Friesians seemed to indicate that forced ventilation by electric fans and water sprinklers were effective enough to protect the reproductive ability of this breed from the adverse effects of a hot climate.

Performance for a small on-site wastewater treatment system using the absorbent biofilter in rural areas (흡수성 Biofilter 를 이용한 농촌 소규모 오수처리 시설의 성능)

  • Kwun, Soon-Kuk;Yoon, Chun-Gyeong
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.4
    • /
    • pp.310-315
    • /
    • 1999
  • The feasibility of an absorbent biofilter system was examined for rural wastewater treatment. Hydraulic loading rates varied from 50 to 250 cm/day. Effluent of the septic tank was fed into the absorbent biofilter, and small ventilation fan was provided to supply air at the rate of 250 L/min to aerate the biofilter. The biofilter system demonstrated high removal rates for $BOD_5$ and TSS at the loading rate of 150 cm/day, generally meeting the Korean effluent water quality standard of 20 mg/L applicable to both. The nutrient removal was less satisfactory than the results of $BOD_5$ and TSS, but it was within the expected range of biological treatment processes. Considering the abnormally high influent concentration of nutrients during the experiment, better performance results could have been obtained if ordinary domestic wastewater was used. The system performance was not significantly affected by the hydraulic loading up to 150 cm/day, which is far more than the loading limit of the sand filter systems. Maintenance requirement was minimal, and no problems with noise, odor, flies or sludge arose. Since the biofilter system can be operated at a distance, operation in remote rural area and multi-system connected to one control office might be advantageous to the rural area. Overall, considering the cost-effectiveness, stable performance, and minimum maintenance, the biofilter system was thought to be a competitive alternative to treat wastewater in Korean rural communities.

  • PDF