• 제목/요약/키워드: Ventilation Effectiveness

검색결과 142건 처리시간 0.02초

Building Control Box Attached Monitor based Color Grid Recognition Methods for User Access Authentication

  • Yoon, Sung Hoon;Lee, Kil Soo;Cha, Jae Sang;Khudaybergenov, Timur;Kim, Min Soo;Woo, Deok Gun;Kim, Jeong Uk
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제12권2호
    • /
    • pp.1-7
    • /
    • 2020
  • The secure access the lighting, Heating, ventilation, and air conditioning (HVAC), fire safety, and security control boxes of building facilities is the primary objective of future smart buildings. This paper proposes an authorized user access to the electrical, lighting, fire safety, and security control boxes in the smart building, by using color grid coded optical camera communication (OCC) with face recognition Technologies. The existing CCTV subsystem can be used as the face recognition security subsystem for the proposed approach. At the same time a smart device attached camera can used as an OCC receiver of color grid code for user access authentication data sent by the control boxes to proceed authorization. This proposed approach allows increasing an authorization control reliability and highly secured authentication on accessing building facility infrastructure. The result of color grid code sequence received by the unauthorized person and his face identification allows getting good results in security and gaining effectiveness of accessing building facility infrastructure. The proposed concept uses the encoded user access authentication information through control box monitor and the smart device application which detect and decode the color grid coded informations combinations and then send user through the smart building network to building management system for authentication verification in combination with the facial features that gives a high protection level. The proposed concept is implemented on testbed model and experiment results verified for the secured user authentication in real-time.

Current status and prospects for in-feed antibiotics in the different stages of pork production - A review

  • Li, Junyou
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제30권12호
    • /
    • pp.1667-1673
    • /
    • 2017
  • Antibiotics have long been of great benefit for people, both in the medical treatment of human disease and in animal food where they improve the growth performance and feed utilization during animal production. Antibiotics as in-feed supplements affect all stages of pork production, including the gestation, nursing, growing, and finishing stages, although the effects show stage-dependent differences. However, the use of antibiotics in animal feed has become a worldwide concern. This review describes why sub-therapeutic levels of antibiotic additives in animal feed have become an integral part of animal feeding programs for more than 70 years, particularly in pork production. It also discusses the threat of the long-term use of sub-therapeutic levels of antibiotics in pork production. In recent years, the effectiveness of in-feed antibiotics has tended to decrease. This review analyzes this change from various perspectives. First, the equipment used at pig farms has improved dramatically and is more sanitary. Worldwide, more pig farms use pig farrowing crates, gestation crates, piglet nursery crates, flooring devices, piggery ventilation and cooler systems, automatic pig feeders, piggery heating equipment, and artificial insemination systems. In addition, scientists have replaced the use of antibiotics with organic acids, fermented mash, probiotics, prebiotics, minerals, oligosaccharides, enzymes, herbs/flavors, and protein/amino acids, and have improved management and husbandry techniques. In addition, animal welfare legislation has been aimed at improving the quality of the floors and living space, ensuring that animals have permanent access to fresh water, and setting a minimum weaning age. Finally, the prospects and the possibility of replacing antibiotics in pork production are described, in line with recent research results.

빌딩 에너지 절감 밸브용 제어 및 감시 보드 개발 (Development of control and monitoring board for building energy saving valve)

  • 오진석;강영민;장재희
    • 한국정보통신학회논문지
    • /
    • 제22권6호
    • /
    • pp.895-902
    • /
    • 2018
  • 건물에 의한 에너지 소비량은 미국 및 일본 등 선진국에서는 전체 국가 에너지 소비량의 40%에 육박하고 있으며, 우리나라에서도 전체 에너지 소비량의 24%를 차지하고 있는 것으로 보고되고 있다. 빌딩에서 HVAC (Heating, Ventilation, and Air conditioning)은 필요 열량에 따라 냉각 유량을 자유롭게 제어할 수 없기 때문에 에너지가 효율적으로 사용되지 않고 있다. 따라서 에너지 절감 밸브를 사용함으로써 유량을 필요한 열량만큼 제어하여 에너지를 절감할 수 있다. 본 논문에서는 에너지 절감 밸브를 개발하기 위한 기본적인 상태를 정의하고 저전력, 고 가성비의 PIC 프로세서 기반의 빌딩 에너지 절감 밸브용 제어 및 감시 보드를 개발한다. 설계된 보드는 온도차 측정을 위한 2개의 온도 값과 유량 값 및 계산된 열량에 관한 정보를 실시간으로 디스플레이 및 전송한다. 개발된 제어 감시 보드는 향후 밸브의 상태를 실시간으로 파악하거나 해상용 밸브 등을 개발하는 데 유용하게 사용될 것이다.

접착제 취급 작업장 내 공기정화 설비를 이용한 휘발성 유기화합물 저감 평가 (Assessment of Volatile Organic Compound Reduction Using an Air Purification Facility in an Adhesive Handling Process)

  • 우재민;김동준;신지훈;민기홍;이채관;양원호
    • 한국환경보건학회지
    • /
    • 제49권2호
    • /
    • pp.78-88
    • /
    • 2023
  • Background: Exposure to volatile organic compounds (VOCs) can have acute and chronic health effects on human beings in general and in working environments. In particular, VOCs are often emitted in large quantities in industrial settings. In such circumstances, there is a need to improve the indoor air quality at workplaces. Objectives: The purposes of this study were to verify the effectiveness of air cleaning devices in workplaces and provide alternative solutions for improving working environments. Methods: Personal exposure and area level of VOCs for workers were evaluated in a car-part adhesive process before and after installing an air cleaning device with a TiO2-coated filter. Passive samplers and direct reading instruments were used to collect and analyze the VOCs, and the removal efficiency and improvement of air quality were evaluated. We also calculated the exposure index (EI) to assess the risk level in the workplace. Results: The removal efficiency for VOCs through the installation of the air cleaning device was approximately 26.9~69.0% as determined by the concentration levels before and after installation. The measured substances did not exceed the exposure limits for the work environment and the EI was less than 1. However, carcinogenic substances such as benzene, formaldehyde, carbon tetrachloride, and trichloroethylene were detected. Conclusions: The application of an air cleaning device can be a solution for controlling the indoor air quality in a workplace, particularly in cases where ventilation systems cannot be installed due to process limitations.

Assessment of Occupational Health Risks for Maintenance Work in Fabrication Facilities: Brief Review and Recommendations

  • Dong-Uk Park;Kyung Ehi Zoh;Eun Kyo Jeong;Dong-Hee Koh;Kyong-Hui Lee;Naroo Lee;Kwonchul Ha
    • Safety and Health at Work
    • /
    • 제15권1호
    • /
    • pp.87-95
    • /
    • 2024
  • Background: This study focuses on assessing occupational risk for the health hazards encountered during maintenance works (MW) in semiconductor fabrication (FAB) facilities. Objectives: The objectives of this study include: 1) identifying the primary health hazards during MW in semiconductor FAB facilities; 2) reviewing the methods used in evaluating the likelihood and severity of health hazards through occupational health risk assessment (OHRA); and 3) suggesting variables for the categorization of likelihood of exposures to health hazards and the severity of health effects associated with MW in FAB facilities. Methods: A literature review was undertaken on OHRA methodology and health hazards resulting from MW in FAB facilities. Based on this review, approaches for categorizing the exposure to health hazards and the severity of health effects related to MW were recommended. Results: Maintenance workers in FAB facilities face exposure to hazards such as debris, machinery entanglement, and airborne particles laden with various chemical components. The level of engineering and administrative control measures is suggested to assess the likelihood of simultaneous chemical and dust exposure. Qualitative key factors for mixed exposure estimation during MW include the presence of safe operational protocols, the use of air-jet machines, the presence and effectiveness of local exhaust ventilation system, chamber post-purge and cooling, and proper respirator use. Using the risk (R) and hazard (H) codes of the Globally Harmonized System alongside carcinogenic, mutagenic, or reprotoxic classifications aid in categorizing health effect severity for OHRA. Conclusion: Further research is needed to apply our proposed variables in OHRA for MW in FAB facilities and subsequently validate the findings.

Respirable Silica Dust Exposure of Migrant Workers Informing Regulatory Intervention in Engineered Stone Fabrication

  • Mahinda Seneviratne;Kiran Shankar;Phillip Cantrell;Aklesh Nand
    • Safety and Health at Work
    • /
    • 제15권1호
    • /
    • pp.96-101
    • /
    • 2024
  • Background: Silicosis among workers who fabricate engineered stone products in micro or small-sized enterprises (MSEs) was reported from several countries. Workplace exposure data of these workers at high risk of exposure to respirable crystalline silica (RCS) dust are limited. Methods: We surveyed workers performing cutting, shaping and polishing tasks at 6 engineered stone fabricating MSEs in Sydney, Australia prior to regulatory intervention. Personal exposure to airborne RCS dust in 34 workers was measured, work practices were observed using a checklist and worker demography recorded. Results: Personal respirable dust measurements showed exposures above the Australian workplace exposure standard (WES) of 0.1 mg/m3 TWA-8 hours for RCS in 85% of workers who performed dry tasks and amongst 71% using water-fed tools. Dust exposure controls were inadequate with ineffective ventilation and inappropriate respiratory protection. All 34 workers sampled were identified as overseas-born migrants, mostly from three linguistic groups. Conclusions: Workplace exposure data from this survey showed that workers in engineered stone fabricating MSEs were exposed to RCS dust levels which may be associated with a high risk of developing silicosis. The survey findings were useful to inform a comprehensive regulatory intervention program involving diverse hazard communication tools and enforcing improved exposure controls. We conclude that modest occupational hygiene surveys in MSEs, with attention to workers' demographic factors can influence the effectiveness of intervention programs. Occupational health practitioners should address these potential determinants of hazardous exposures in their workplace surveys to prevent illness such as silicosis in vulnerable workers.

30분 자가호흡관찰에 의한 기계적 호흡치료로부터의 이탈 (Weaning Following a 30 Minutes Spontaneous Breathing Trial)

  • 신진;고영민;정연태
    • Tuberculosis and Respiratory Diseases
    • /
    • 제44권6호
    • /
    • pp.1326-1331
    • /
    • 1997
  • 연구배경 : 기계적 호흡치료로 부터의 이탈이란 호흡일을 인공호흡기에서 환자에게 되돌리는 과정으로 여러가지 이탈 방법 중 어떤 방법이 더 낫다는 확실한 보고는 없지만 최근의 연구에서는 자가호흡관찰에 의한 이탈시도가 더 낫다는 보고가 있다. 자가호흡관찰에 의한 이탈때도 자가호흡관찰시간에 대한 확실한 의견은 없다. 저자들은 기관내 튜브를 통한 산소공급으로 1시간 자가호흡관찰후 이탈 및 발관을 동시에 시행하는 방법의 유용성에 대해서 발표한 적이 있으면 이번에는 관찰시간을 30분으로 단축하여 성공이 예상되면 다시 인공호흡기 연결없이 바로 발관을 시행하는 적극적인 이탈 방법을 시행하였다. 방 법 : 1994년 8월부터 1995년 7월까지 1년간 호흡부전으로 기계호흡을 받은 환자를 대상으로 하였으며 이탈은 호흡부전을 초래한 기저질환이 호전되고 활력징후들이 안정된 상태로 유지되며 $FiO_2$ 0.4 이하에서 동맥혈 가스분석상 산소분압이 55mmHg 이상인 경우 시도하였다. 이탈기준을 만족하는 대상환자에서 기관내 튜브를 통해 분당 6L 산소를 공급하고 이탈시킨 상태에서 30분 동안 의사가 환자옆에서 환자의 전신상태, 호흡횟수, 맥박수를 고려하여 청색증, 발한, 빈맥, 혈압상승, 혈압저하 등이 없고, 가스분압이 55mmHg 이상으로 유지될 경우 인공호흡기 연결없이 발관을 시행하였다. 인공호흡기 이탈후 48시간 이상 자가호흡이 가능한 경우를 이탈성공으로 정의하였다. 결 과 : 기계적 호흡치료률 받은 42명중 이탈기준을 만족시키는 15명의 환자에게서 총 17회의 이탈을 시행하였다. 이 17회의 30분 자가호흡관찰후 발판을 시행하는 이탈시도 중 14회가 성공하여 82.4%의 성공율을 보였다. 이탈에 성공한 14명의 환자에서 30분간의 호흡관찰후 실제 이탈후 발관까지는 8명이 30분, 3명이 1시간, 3명이 2시간 이상 소요되었다. 결 론 : 이상의 결과로 튜브를 통한 산소공급후 30분 자가호흡관찰에 의한 이탈의 경우도 1시간 자가호흡관찰에서처럼 높은 이탈 성공률을 보이는 쉽고 유용한 방법이다.

  • PDF

혈액암 환자의 원내 사망률에 미치는 신속대응팀의 효용성 (Effectiveness of Rapid Response Team on In-hospital Mortality in Patients with Hematologic Malignancy)

  • 박소정;홍상범;임채만;고윤석;허진원
    • 한국의료질향상학회지
    • /
    • 제27권2호
    • /
    • pp.18-29
    • /
    • 2021
  • Purpose: Patients with hematologic malignancy (HM) typically have a high mortality rate when their condition deteriorates. The chronic progressive course of the disease makes it difficult to assess the effect of intervention on acute events. We investigated the effectiveness of a rapid response team (RRT) on in-hospital mortality in patients with HM. Methods: We retrospectively analyzed the data of patients with HM who admitted to the medical intensive care unit between 2006 and 2015. Clinical outcomes before and after RRT implementation were evaluated. Results: A total of 228 patients in the pre-RRT period and 781 patients in the post-RRT period were included. The overall in-hospital mortality was 55.4%. Patients in the post-RRT period had improved survival; however, they required more vasopressor therapy, continuous renal replacement therapy, and extracorporeal membrane oxygenation. Multivariate analysis revealed that in-hospital mortality was associated with RRT activation (hazard ratio [HR], 0.634; 95% confidence interval [CI], 0.498-0.807; p < .001), neurological disease (HR, 2.007; 95% CI, 1.439-2.800; p < .001), sequential organ failure assessment score (HR, 1.085; 95% CI, 1.057-1.112; p < .001), need for continuous renal replacement therapy (HR, 1.608; 95% CI, 1.206-1.895; p< .001), mechanical ventilation (HR, 1.512; 95% CI, 1.206-1.895; p< .001), vasopressor (HR, 1.598; 95% CI, 1.105-2.311; p = .013), and extracorporeal membrane oxygenation (HR, 1.728; 95% CI, 1.105-2.311; p = .030). Conclusion: RRT activation may be associated with improved survival in patients with HM.

시뮬레이션 모형에 의한 온실의 열환경 분석 (Analysis of Greenhouse Thermal Environment by Model Simulation)

  • 서원명;윤용철
    • 생물환경조절학회지
    • /
    • 제5권2호
    • /
    • pp.215-235
    • /
    • 1996
  • 본 연구에서 수행한 Model 시뮬레이션에 의한 열환경 분석 기법은 지역별로 다양한 기상여건 하에서 대상온실의 난방 및 냉방부하를 보다 합리적으로 예측할 수 있을 뿐만 아니라 냉방이나 난방용 시스템의 결정을 비롯한 난방대책을 수립하고, 에너지 이용 전략의 수립이나 계절적인 작부계획 수립, 온실산업용 적지선정 등에 유익하게 활용될 수 있을 것이라 판단된다. 본 연구에서는 온실의 적극적인 환경조절 유형을 난방과 냉방의 두 가지로 대별하고, 난방 소요열량 산정을 비롯하여 야간의 보온 커튼효과, Heating Degree-Hour 산정 등 난방과 관련된 시뮬레이션은 동적 모형을 이용하여 시간별, 일별 및 월별로 검토하였으며, 환기를 비롯한 차광, 증발냉각시스템의 효과 분석은 정적모형을 이용하여 검토하였다. 특히 하절기 지하수와 같은 저온수를 직접 이용하거나 Heat Pump를 통하여 확보될 수 있는 저온수를 이용하여 온실의 피복면에 살수함으로서 확보할 수 있는 온실냉방효과를 검토하는 데는 1.2m$\times$2.4m 크기의 모형온실을 제작하여 기초실험을 수행함으로서 동절기의 수막시스템의 보온효과와 마찬가지로 하절기 냉방 효과를 거둘 수 있다는 가능성을 확인하였다. 본 연구에 활용된 온실의 수치 환경모형 중 난방관련 시뮬레이션용 동적 수치모형은 소기의 목적을 달성하는데 충분히 응용될 수 있는 이론모형이다. 이 이론모형이 범용성이 높은 것은 온실 내ㆍ외의 미기상 변화, 특히 난방이나 냉방이 본격적으로 요구되는 기간동안에 온도, 습도, 일사, 풍속 등의 미기상 인자들을 면밀하게 관찰하여 실측된 자료를 바탕으로 개발되었고, 다양한 자료에 의해 충분히 검정되었기 때문이다. 본 연구에서는 경남 진주지역의 어느 특정 기간(1987년)의 시간별 기상자료를 중심으로 온실의 열적 환경변화에 대한 수치모형 시뮬레이션을 실시하였으며, 아직 수치모형에 의한 시뮬레이션이 불가능한 일부 냉방효과를 검토하는 데는 모형 실험을 실시하였으며, 그 결과를 요약하면 다음과 같다. 1. 주간과 야간의 설정온도를 달리하고 다단계 변온조절방식으로 시뮬레이션을 행한 결과 난방 소요열량은 난방 설정온도에 따라 현저한 차이를 보였다. 특히 주간 설정온도에 비하여 야간 설정온도가 난방 소요열량에 예민하게 영향을 미치므로 야간의 설정온도 결정에 신중을 기해야 할 것으로 판단된다. 2. 기존의 Heating Degree-Hour 자료는 평균 외기온을 중심으로 임의의 설정온도에 대하여 산정된 값이므로 난방 소요열량에 대한 상대적인 비교수단은 되나 고려되는 기상인자의 제한과 설정온도의 임의성 때문에 실용성이 부족하다. 따라서 본 연구에서 제시된 것처럼 온실 주변의 제반 미기상 인자나 경계조건이 반영됨은 물론 작물의 생육상태 및 구체적인 설정온도까지도 고려하는 동적 수치모형으로 시시각각으로 예측된 실내기온을 중심으로 재배기간 동안의 난방열량을 적산함이 합리적이라 판단된다. 기존의 MDH 자료로 난방 설계를 할 경우에는 지나치게 과잉설계 될 가능성이 있다. 3. 산정된 난방 소요열량은 물론 커튼의 보온성능도 월별 기상여건에 따라 현저한 차이를 보이며, 시뮬레이션에 이용된 커튼의 경우 높은 보온효과를 보임으로서 년 평균 50% 이상의 난방 에너지를 절감할 수 있으며, 동절기 3-4개월의 집중 난방기에 에너지가 크게 절감됨을 발견할 수 있다. 4. 고온기 환기성능은 온실의 구조, 기상조건, 작물의 생육상태 등에 따라 다소의 차이가 있으나 환기율에 의해 크게 좌우되며, 시뮬레이션에 이용된 두 가지 농가보급형 온실 모두 환기율의 증가에 따른 실내기온의 강하 효과가 환기율이 1회/min 정도를 넘어서면서 급격히 둔화되는 현상을 보인다. 이는 기존에 권장되고 있는 적정 환기율인 1회/min 전후의 환기 시스템을 갖추는 것이 합리적임을 확인해 준다. 5. 작물이 성숙된 유리온실에서 외기의 상대습도가 50%인 쾌청한 주간동안 연속적으로 1회/min로 환기를 시킬 경우 실내기온 36.5$^{\circ}C$의 대조구에 비한 온도강하는 50% 차광만 했을 시 2.6$^{\circ}C$이고 효율 80%의 Pad & Fan 시스템만 작동시 6.1$^{\circ}C$ 정도이며, 차광과 냉각시스템을 동시에 작동시는 약 8.6$^{\circ}C$로서 외기온보다 3.3$^{\circ}C$가 낮은 28$^{\circ}C$까지 실내온도를 낮출 수 있으나, 동일 조건하에서 외기의 상대습도가 80%로 높은 경우에는 Pad & Fan시스템에 의한 온도강하가 2.4$^{\circ}C$에 불과하여 50% 차광하에서도 외기온 이하로 실내온도를 낮출 수 없음을 알 수 있다. 6. 하절기 3개월(6/1-8/31)동안 Pad & Fan 시스템의 냉방효과($\Delta$T)는 설정된 작동 온도에 따라 다소 차이를 보일 것으로 예상되나 본 시뮬레이션에서 설정한 시스템의 작동 온도 27$^{\circ}C$에서 상대습도와의 상관관계는 대략 다음과 같았다: $\Delta$T= -0.077RH+7.7 7. 전형적인 하절기 주간기상 하에서 경시적 냉방효과를 분석한 결과 환기만으로는 실내기온을 외기온 보다 5$^{\circ}C$ 높게 유지하는 정도가 고작이고, 차광이나 증발식 냉방시스템 만으로는 작물이 성숙한 단계에서조차도 외기온 이하로 떨어뜨리기가 어려우나 차광과 아울러 증발식 냉방을 병행할 경우에는 작물상태에 따라 다소 차이는 있지만 실내기온을 외기온보다 2.0-2.3$^{\circ}C$ 낮게 유지할 수 있음을 발견할 수 있다. 8. 일사가 차단된 27.5-28.5$^{\circ}C$의 외기온하에서 6.5-8.5$^{\circ}C$의 냉수를 온실 바닥면적 1$m^2$당 1.3 liter/min의 유량으로 온실표면에 살수했을 때 실내기온을 외기온보다 1$0^{\circ}C$ 낮은 16.5-18.$0^{\circ}C$ 정도로 낮출 수 있었다. 앞으로 살수 수온(T$_{w}$ )이나 외기온(T$_{o}$ ) 뿐만아니라 살수율(Q)에 따라 온실기온 (T$_{g}$ )에 미치는 상관 관계 T$_{g}$ = f(T$_{w}$ , Q, T$_{o}$ )를 구명하여 지하수 자체 또는 Heat Pump를 이용한 지하수온 이하의 냉수로 온실냉방의 가능성을 구명하는 것이 앞으로의 과제이다.

  • PDF

플라스틱 온실(温室)의 일사량(日射量) 분석(分析)과 열적(熱的) 환경(環境)의 시뮬레이션에 관(關)한 연구(硏究) -플라스틱 온실(温室)의 열적환경(熱的環境)의 시뮬레이션- (Analysis of solar radiation and simulation of thermal environment in plastic greenhouse -Simulation of thermal environment in plastic greenhouse-)

  • 박재복;고학균
    • Journal of Biosystems Engineering
    • /
    • 제12권2호
    • /
    • pp.16-27
    • /
    • 1987
  • Greenhouse farming was introduced to the Korean farmers in the middle of 1950's and its area has been increased annually. The plastic greenhouse, which is covered with polyethylene or polyvinyl chloride film, has been rapidly spread in greenhouse farming since 1970. The greenhouse farming greatly contributed to the increase of farm household income and the improvement of crop productivity per unit area. Since the greenhouse farming is generally practiced during winter, from November to March, the thermal environment in the plastic greenhouse should be controlled in order to maintain favorable condition for plant growing. Main factors that influence the thermal environment in the plastic greenhouse are solar radiation, convective and radiative heat transfer among the thermal component of the greenhouse, and the use of heat source. The objective of this study was to develop a simulation model for thermal environment of the plastic greenhouse in order to determine the characteristics of heat flow and effects of various ambient environmental conditions upon thermal environments within the plastic greenhouse. The results obtained are summarized as follows: 1. Simulation model for thermal environment of the plastic greenhouse was developed, resulting in a good agreement between the experimental and predicted data. 2. Solar radiation being absorbed in the plant and soil during the daytime was 75 percent of the total solar radiation and the remainder was absorbed in the plastic cover. 3. About 83 percent of the total heat loss was due to convective and radiative heat transfer through the plastic cover. Air ventilation heat loss was 5 to 6 percent of total heat loss during the daytime and 16 to 17 percent during the night. 4. The effectiveness of thermal curtain for the plastic greenhouse at night was significantly increased by the increase of the inside air temperature of the greenhouse due to the supplementary heat. 5. When the temperature difference between the inside and outside of the greenhouse was small, the variation of ambient wind velocity did not greatly affect on the inside air temperature. 6. The more solar radiation in the plastic greenhouse was, the higher the inside air temperature. Because of low heat storage capacity of the plant and soil inside the greenhouse and a relatively high convective heat loss through the plastic cover, the increase of solar radiation during the daytime could not reduce the supplymentary heat requirement for the greenhouse during the night.

  • PDF