종이의 투기도가 담배 물성에 미치는 영향 (The Effect of Paper Permeability on Cigarette Properties)

  • 김영호;한영림;이문용;이영택;김정열
    • 펄프종이기술
    • /
    • 제33권1호
    • /
    • pp.64-72
    • /
    • 2001
  • The cigarette ventilation affects not only the amount of tar and nicotine delivery by a cigarette, but also the composition of the smoke. Therefore, it is important to stabilize of variability in cigarette ventilation that would be affected by changes in cigarette components. This work was conducted to determine the major factors that influence the cigarette ventilation and also to provide fundamental informations for improving the uniformity of cigarette performances. To evaluate the effect of cigarette ventilation as a dependant variable, the three independent factors were the air permeability of plugwrap, tipping paper and the filter pressure drop. We determined the effect of paper permeability on ventilation variability and the optimum condition in combinations of independent factors. The mean of cigarette ventilation was increased as plugwrap permeability increases, particularly at 26,000 CU. However, it was exhibited that standard deviation and coefficient of variation of the cigarette ventilation were decreased with increasing plugwrap permeability. At the 600 CU and 1,200 CU of tipping paper permeability, process capability index (Cp) of the cigarette ventilation increased as plugwrap permeability increases. Following the optimum condition of cigarette ventilation induced by fitted regression equation, one was to optimize 50% ventilation level is by combination with plugwrap permeability of 16,000 CU, tipping paper permeability of 810 CU, filter pressure drop of 319 mm$H_2O$, respectively.

  • PDF

Blower Door Test를 이용한 공동주택 자연환기시스템의 환기성능 분석 (Analysis on Ventilation Performance of Natural Ventilation Systems in Multi-Family Housing Using Blower Door Test)

  • 김민석;어진선;홍구표;김병선
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.129-134
    • /
    • 2016
  • Today, natural ventilation systems are widely applied in multi-family housing. However, studies using the wind data trend line of the blower door test are insufficient. Purpose: Through this study, we will propose a computational method about ventilation performance of natural ventilation systems by conducting blower door test. Method: First, we sealed the gaps between the main systems including the natural ventilation system and conducted the blower door test. Next, the natural ventilation system was opened, the blower door test was conducted, and the difference in air flow rate between when closed and when opened was checked. Blower door test was carried out with a pressure difference of 50 Pa. Result: Therefore, the ventilation performance of the natural ventilation system was checked by drawing a trend line using the data to calculate the air flow rate at 2 Pa of the natural ventilation equipment standard pressure difference.

패시브환기외피의 통기성능 및 열관류율에 대한 연구 (A Study on Ventilation and Heat Transfer Coefficient of Passive Ventilation Skin)

  • 이태철;손유남;윤성환
    • 설비공학논문집
    • /
    • 제24권9호
    • /
    • pp.679-684
    • /
    • 2012
  • This paper aims to evaluate performances of ventilation and insulation of 6types PVS(Passive ventilation skin) by numerical simulation. The results are as follows. 1) The result of Performance of ventilation by pressure difference, it was shown that the amount of ventilation changed bigger under 1Pa and amount of ventilation increased according to increase opening area (${\alpha}A$). Although same opening area of PVS, it can predict that pressure differences cause ventilation differences. 2) In case of same opening area of PVS, however, it was changed the amount of ventilation each types of PVS that is distinguished opening area by flow coefficient. 3) Dynamic U-value that represents performance of insulation PVS was similar change upper ${\alpha}A40\;cm^2/m^2$, great change in casse of 0.1 Pa pressure difference. In case of ${\alpha}A10\;cm^2/m^2$, it was changed bigger under 0.3 Pa pressure difference, ${\alpha}A20\;cm^2/m^2$ of PVS was changed under 0.2 Pa pressure difference.

취침 시 환기횟수에 따른 $CO_2$ 피크치 제어에 관한 연구 (A Research on the $CO_2$ Peak Point Control According to Ventilation Rate During Sleeping)

  • 김세환;김동규;박종일
    • 설비공학논문집
    • /
    • 제21권1호
    • /
    • pp.49-54
    • /
    • 2009
  • Ventilation requirement of apartment was mandated according to building equipment standards in 2006. When ventilation unit was considering for indoor air quality maintenance, we needed energy saving and efficiency ventilation control methods. This study carried out experiment of ventilation rate 0.7 adequacy. When we lived in apartment, we assumed that sleeping time was long stayed time in unconsciousness. Experiments carried out ventilation rate 0, 0.1, 0.4 and 0.7 in environment chamber from 22 o'clock to 06 o'clock, the concentration of $CO_2$, temperature and humidity rate measured. Analyzing the results, conclusions are as follows. 1) When we sleep in bedroom, ventilation rate 0.4 meet the requirements of domestic legal standards. Conform fan of similarity law, ventilation rate 0.4 reduced power cost about 80% than 0.7. 2) In generally sleeping time 8 hours, peak point control reduced running time of ventilation unit about 43% than normal control.

침실 공기질 개선을 위한 강제 환기횟수에 관한 연구 (A study on Forced Ventilation Rate for Bedroom Indoor Air Quality Improvement)

  • 김동규;이성;김세환
    • KIEAE Journal
    • /
    • 제9권1호
    • /
    • pp.85-90
    • /
    • 2009
  • The indoor air quality is one of the most important issues of designing ventilation in high rise apartment buildings. This study suggested proper ventilation rate in the apartment bedroom where mechanical ventilation system has installed. Six university students(four male and two female) were participating in the experiment. Experiments were performed in environmental chamber. Experimental conditions were combinations from three ventilation rate 0, 0.4 and 0.7. Measurement items during 8 hours of experimental time were temperature, humidity, carbon dioxide concentrations and questionnaire surveyed aftrer sleeping. The concentration of Carbon Dioxide depending on ventilation rate in the chamber was analyzed for proper ventilation rate. The results of this paper can be summarized as follows. (1) When two persons experiment, 0.7 ventilation rate was in excess of 1000ppm. (2) When one person experiment, 0.7 and 0.4 ventilation rates were satisfied the criteria of IAQ. (3) It compared 0.4 with 0.7 in the ventilation rate, 0.4 ventilation rate could reduced about 80% of the power by fan similarity law.

압력손실을 고려한 양돈시설의 반폐회로 환기시스템의 환기량 및 혼합비율 평가 (Evaluation of Ventilation Rate and External Air Mixing Ratio in Semi-closed Loop Ventilation System of Pig House Considering Pressure Loss)

  • 박유미;김락우;김준규
    • 한국농공학회논문집
    • /
    • 제65권1호
    • /
    • pp.61-72
    • /
    • 2023
  • The increase in the rearing intensity of pigs has caused deterioration in the pig house's internal environment such as temperature, humidity, ammonia gas, and so on. Traditionally, the widely used method to control the internal environment was through the manipulation of the ventilation system. However, the conventional ventilation system had a limitation to control the internal environment, prevent livestock disease, save energy, and reduce odor emission. To overcome this problem, the air-recirculated ventilation system was suggested. This system has a semi-closed loop ventilation type. For designing this system, it was essential to evaluate the ventilation rates considering the pressure loss of ducts. Therefore, in this study, pressure loss calculation and experiment were conducted for the quantitative ventilation design of a semi-closed loop system. The results of the experiment showed that the inlet through which external air flows should always be opened. In addition, it was also found that for the optimum design of the semi-closed loop ventilation system, it was appropriate to install a damper or a backflow prevention device rather than a ventilation fan.

실내 유해가스 제거효율 향상을 위한 환기성능에 관한 실험적 연구 (An Experimental Study on the Ventilation Performance to Enhance Removal Efficiency of Indoor Hamful Gases)

  • 구재현
    • 한국화재소방학회논문지
    • /
    • 제23권5호
    • /
    • pp.117-124
    • /
    • 2009
  • 본 연구의 목적은 실내 유해가스의 제거효율 향상을 위하여 기계 환기시스템의 환기성능을 분석하는 것이다. 환기성능은 ASTM E741-83 기준에 의거하여 체강법을 사용하여 평가하였다. 추적가스($CO_2$) 기법을 사용하여 환기율과 급기/배기구 위치에 따른 환기성능이 평가되었다. 결과적으로 $CO_2$ 농도는 환기율 증가에 따라 지수적으로 감소하며 환기농도가 증가함을 파악하였다. 2종 환기방식 시스템의 환기성능이 1종 환기방식 또는 3종 환기방식 보다 더 우수하였다. 환경공조챔버에서 자연감쇠의 경우와 비교하여 급기량 570Lpm에서 1시간 후에 재실자가 없는 경우의 환기성능은 55%까지 증가하였고 1인 재실자가 있는 경우의 환기성능은 25%까지 증가하였다. 사무실에서 급기량 570Lpm인 경우 환기성능은 자연감쇠와 비교하여 15% 이상 크게 나타났다.

도로터널 횡류환기방식의 환기특성 및 시스템 설계 관한 연구 (A study on the ventilation characteristics and design of transverse ventilation system for road tunnel)

  • 유지오;김효규
    • 한국터널지하공간학회 논문집
    • /
    • 제20권2호
    • /
    • pp.305-315
    • /
    • 2018
  • 본 연구에서는 도로터널의 횡류환기 및 반횡류환기 방식의 설계 방안을 도출할 목적으로 수치해석적인 방법에 의해서 환기특성을 고찰하고 소요환기량과 환기 시스템 용량의 관계를 검토하였으며, 다음과 같은 결과를 얻었다. 급 배기 횡류환기방식에서 환기시스템의 급 배기풍량은 이론적으로 소요환기량과 자연환기량의 차가 되나, 해석결과에 의하면 환기시스템 용량은 소요환기량과 자연환기량의 차보다 약 10%정도 증가하는 것으로 나타나고 있다. 또한 제트팬을 설치하여 종방향 풍속을 증가시키는 경우, 환기시스템의 급배기 풍량은 감소하나, 터널풍속이 증가할 수록 터널 내 농도가 감소하기 때문에 오염물질에 대한 배기효과가 감소하여, 횡류 환기시스템의 용량 감소효과는 감소하는 것으로 나타나고 있다. 급기만 하는 반횡류식에서는 터널입구 풍향이 차량진행방향과 반대인 경우에는 환기시스템의 급기풍량은 소요환기량과 동일하나, 해석결과에서는 약 13.3% 이내의 범위에서 증가하는 것으로 나타나고 있으며, 터널입구 풍속이 음수인 상태에서는 제트팬 댓수를 증가하여 도 환기효과는 기대할 수 없는 것으로 나타났다.

방음터널의 자연환기성능 향상에 대한 연구 (The Study on the Improvement of Ventilation Performance in the Soundproof Tunnel)

  • 이경희;조성우;최정민;김경환;박창섭
    • 설비공학논문집
    • /
    • 제17권10호
    • /
    • pp.922-929
    • /
    • 2005
  • This paper compared ventilation performance between the sound roof tunnel with flat roof and the sound roof tunnel with gable roof. The ventilation rate of the sound roof tunnel is calculated by natural ventilation rate plus ventilation by vehicle. The roof type is divided by the shape of the roof and the ventilator location on the roof. The results between calculation and CFD on the ventilation rate are almost alike. The ventilation rate on the flat roof is $558.4\;m^3/s$ with mid-ventilator and $496.8\;m^3/s$ with left-right ventilator. The ventilation rate on the gable roof is $653.2\;m^3/s$ with mid-ventilator and $611.6\;m^3/s$ with left-right ventilator. The ventilation rate of soundproof with gable roof is higher than that with flat roof. The ventilation rate and with mid-ventilator is higher than that with left-right ventilator the soundproof roof. Therefore, the ventilation performance of soundproof roof depends on the roof shape and ventilator location on the roof.

Effective Local Exhaust Ventilation on Cooking Fumes of Seasoned Meats

  • Lee Byeong Kyu;Ellenbecker Michael J.
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제2권1호
    • /
    • pp.49-56
    • /
    • 1998
  • This study identified the fumes produced from the cooking of the seasoned meats containing various condiments such as garlic, onion, pepper, soy sauce, and sesame oil. Concentrations, at the breathing zone of the cook, of volatile organic compounds (VOCs) and aldehydes included in the cooking fumes of seasoned meats were identified. Many chloro and fluoro-aliphatic hydrocarbons, aromatic hydrocarbons, ketones, and aldehydes, which could be carcinogen suspecting chemicals, were producing from the cooking fumes of the seasoned meats. This study also identified the ventilation efficiencies of the cooking fumes of the six exhaust ventilation systems, which were widely being used in the general apartments, houses, and small-food factories. For a comparison of the ventilation efficiencies of the systems, acetaldehyde was chosen as a marker pollutant and its concentrations at the breathing zone of the cook were identified. The laboratory fume hood showed the best ventilation efficiency of the six ventilation systems studied, and then the lateral hood ventilation and the down draft ventilation followed the laboratory fume hood. Finally, this study identified that both a wall factor nearby pollutant sources and a distance factor between the hood face and pollutant sources should be also considered for an effective local exhaust ventilation system design.

  • PDF