• Title/Summary/Keyword: Ventilating condition

Search Result 45, Processing Time 0.025 seconds

A Research on the Actual Condition of Narrator Models' Wearing Uniform (도우미의 유니폼 착용실태 조사 - 내레이터 모델을 중심으로 -)

  • Jung, Hea-Young;Lee, Myung-Hee
    • Fashion & Textile Research Journal
    • /
    • v.6 no.6
    • /
    • pp.707-714
    • /
    • 2004
  • This study was carried out to research the actual condition of narrator models' wearing uniform, targeting on the narrator models who are being currently active and are from 19-year-old to 30-year-old. A poll was performed through visiting internet circles and spots, and the characteristic of objects, the form of uniform, attitude on uniform, dissatisfaction index on wearing uniform and preference index on wearing uniform were researched. It was carried out from August 18, 2003 to August 31, 2003. In order to perform this study, 161 questionnaires were used in all, and frequency analysis was implemented using SPSS 10.0. The objects of study were composed of female. Those who are from 21-year-old to 25-year-old accounted for 74.5%, and those who have career from 2 years to 3 years accounted for 75.5%. In respect to attitude on wearing uniform, affirmative answers, affirmative answers, such as a sense of belonging, a pride in activity and increase of efficiency, accounted for 68.8%. On the other hand, in respect to a harmonization between uniform and work, just the 39.8-percent showed affirmative reaction. Concerning the functionality of uniform, such as retaining warmth and ventilating, dissatisfaction index showed very high value; it is judged that it should be improved henceforth. Working postures were researched, following the order of standing posture and arm-using posture. In inconvenient actions, bending down and moving arms were orderly pointed out. With regard to the dissatisfaction of size, busts, the length of skirt and waist girth were orderly pointed out. Likewise, considering the parts of which room is required, bust, hip girth and waist girth were orderly pointed out. As to the points that should be bettered, design and functionality were orderly pointed out. In respect to materials of uniform, sweat-absorption material, light material and well-ventilated material were orderly suggested.

The Measurement of Airtightness Performance of Multi-Family Housing (다가구 및 다세대 원룸주택의 기밀성능 실측연구)

  • Baek, Nam-Choon;Han, Seung-Hyeon;Lee, Wang-Je;Yoon, Jong-Ho;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.14 no.5
    • /
    • pp.117-121
    • /
    • 2014
  • Even though a study of airtightness performance of apartment and detached house have been done constantly, there are few of studies of multi-family housing which increasing every year. Therefore, this study analyzed airtightness performance of 20 households of one room in Daejeon to investigate airtightness performance standard. All experiments were performed under the same conditions except sealing windows to investigate airtightness performance without sealing windows (natural condition) and airtightness performance with sealing windows of studio apartment. As results, (1) average ACH50 without sealing windows was 19.2/h for pressurization, and 12.8/h for depressurization and (2) average ACH50 with sealing windows was 16.0/h for pressurization, and 10.7/h for depressurization and ACH50 in both condition, ACH50 under pressurization was about 50% higher than that under depressurization. Throughout this experiment, we can figure out that about 16% of air infiltration rate is occurred in windows, and the other 84% is occurred in rest of places such as Junction structure, socket and ventilating opening.

A Comparative Analysis of the Level of Occupational Health : Before and After the Subsidiary Program on Health Care Management of Small Scale Industries (영세사업장 보건관리 지원사업 실시 전후의 산업보건수준 비교 분석)

  • Jung, Hye Sun
    • Korean Journal of Occupational Health Nursing
    • /
    • v.4
    • /
    • pp.58-83
    • /
    • 1995
  • The small scale industries which have less than 30 employees occupy 86.5% of total number of industries in Korea. And though they have higher accident rate and lower environmental condition than big industries, it has been not mandatory to appointing health care manager at factory. So, from 1993, government subsidizes to the health care management of small industries. The purpose of this study is to identify the real feature of health care status in small industries, and to evaluate the level of health care management, before and after the subsidiary program. 65 small plating industries which have been managed by the same health care management support institution in 1993 were selected for study. Of the 65 industries, 3 which have not taken both environmental evaluation and health screening in 1994, and 9 which have closed were excluded from study sample. And the remaining 53 were analyzed by using the results of environmental evaluation and health screening, reported to the Ministry of Labor, before and after the subsidiary program, the analysis was done by the comparison of the two year paired data of the same industry. Over-permissible-limit rate, health screening implementation rate, above grade C rate were calculated and compared. The status of health care management ; 1. Of the sample industries, 96.9% provide protective equipment and 80.0% set up ventilating system. Protective gloves (89.2%) and protective clothing (80.0%) are widely provided, but ear plugs (4.6%) are rarely provided. 21.5% of the protective equipment are well put on, and 40.4% of the ventilating systems function well. 2. In 1993, 35 industries, 53.8% of the sample, checked working environment twice. Over-permissible-limit rates of heavy metal (12.2%), suspended particle (11.1%), noise (5.5%) were high. To put on protective equipment and to set up local ventilating system were pointed out by the examiners. 3. General health screening was done at 63.1% of the sample industries and 35.3% of total workers were examined. Specific health screening was done at 93.8% of the sample industries and 75.4% of workers were examined. 15.5% of workers was provided to be above grade C and to have digestive system disease (43.3%), circulatory disease (18.9%), and hematopoietic disease (14.2%), etc. 4. In 1993, the subsidiary program of health care management was provided in forms of health education, health counseling, and rounding check of working field. And 61.5%, 83.0%, 55.4% of sample industries respectively received it. The average visit per industry was 1.8. Comparisons of the level of occupational health before and after the subsidiary program ; 1. Over-permissible-limit rates of hazardous factors of 1993 and that of 1994 were compared. The rates of suspended particle, noise, organic solvent of 1994 (37.5%, 13.4%, 24.2% respectively) were higher than that of 1993 (25.0%, 6.0%, 6.3% respectively). In the case of acid, there was no difference between the rate of 1993 and that of 1994. Only the rate of heavy metal decreased from 12.9% in 1993 to 3.0% in 1994. 2. General health screening was done at 38.7% of the sample industries in 1993 and at 44.6% in 1994. But the implementation rate of specific health screening decreased from 72.4% in 1993 to 64.6% in 1994. 3. The implementation rate of specific health screening was analyzed by some health factors. The rate of suspended particle increased from 61.8% in 1993 to 91.2% in 1994. But the rates of the others-noise, organic solvent, heavy metal, specific chemical substances-decreased. 4. Above grade C rate in health screening increased from 27.8% in 1993 to 35.5% in 1994. But that of endocrine disorders and pulmonary disease decreased.

  • PDF

Environment Factors for Germination, Growing and Storage of Sprout Vegetables of Coreopsis tinctoria Nutt., Saussurea pulchella (Fisch.) Fisch. and Matricaria recutica L. (국화과 기생초, 각시취 및 저먼캐모마일 새싹채소의 발아, 재배 및 저장에 미치는 환경요인)

  • Lee, Moo-Yeul;Shin, So-Lim;Chang, Young-Deug;Lee, Cheol-Hee
    • Korean Journal of Plant Resources
    • /
    • v.22 no.2
    • /
    • pp.136-144
    • /
    • 2009
  • Germination tests on 3 species that have potential for use as sprout vegetables, such as Coreopsis tinctoria, Saussurea pulchella, and Matricaria recutica, were conducted for 20 days under different temperatures of $15{\sim}30^{\circ}C$, and conditions of light and dark. C. tinctoria showed germination of 83% under $15^{\circ}C$ and dark condition after 4 days, S. pulchella 51.7% under $25^{\circ}C$ and light condition after 20 days, and M. recutica 90.3% under $25^{\circ}C$ and dark condition after 4 days. To investigate optimum plantlet size before greening treatment, seeds germinated were allowed to grow under darkness. The optimum growth of C. tinctoria was obtained under $30^{\circ}C$ after 5 days, S. pulchella under $25^{\circ}C$ after 6 days, and M. recutica under $20^{\circ}C$ after 6 days. Greening treatment resulted in diminished longitudinal growth, but C. tinctoria and S. pulchella showed more vigorous latitudinal growth. Days required before marketing as sprout vegetables were different according to species - Three days of greening was good for C. tinctoria, 2 for S. pulchella, no greening for M. recutica. Generally, tightly sealed containers for minimum water loss were recommended for storage of sprout vegetables after harvest. However, storage methods for each species were different depending on various factors like temperature of storage, presence of ventilation holes of storage packages and forms of marketing. More detailed research for above 3 species is proposed.

Numerical Analysis on the Initial Cool-down Performance Inside an Automobile for the Evaluation of Passenger's Thermal Comfort (차량 내부 탑승자의 쾌적성 평가를 위한 초기 냉방운전 성능에 대한 수치해석적 연구)

  • Kim, Yoon-Kee;Yang, Jang-Sik;Baek, Je-Hyun;Kim, Kyung-Chun;Ji, Ho-Seong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.5
    • /
    • pp.115-123
    • /
    • 2010
  • Cool-down performance after soaking is important because it affects passenger's thermal comfort. The cooling capacity of HVAC system determines initial cool down performance in most cases, the performance is also affected by location, and shape of panel vent, indoor seat arrangement. Therefore, optimal indoor designs are required in developing a new car. In this paper, initial cool down performance is predicted by CFD(computational fluid dynamics) analysis. Experimental time-averaging temperature data are used as inlet boundary condition. For more reliable analysis, real vehicle model and human FE model are used in grid generation procedure. Thermal and aerodynamic characteristics on re-circulation cool vent mode are investigated using CFX 12.0. Thermal comfort represented by PMV(predicted mean vote) is evaluated using acquired numerical data. Temperature and velocity fields show that flow in passenger's compartment after soaking is considerably unstable at the view point of thermodynamics. Volume-averaged temperature is decreased exponentially during overall cool down process. However, temperature monitored at different 16 spots in CFX-Solver shows local variation in head, chest, knee, foot. The cooling speed at the head and chest nearby panel vent are relatively faster than at the knee and foot. Horizontal temperature contour shows asymmetric distribution because of the location of exhaust vent. By evaluating the passenger's thermal comfort, slowest cooling region is found at the driver's seat.

A Study of Heat St Smoke Evacuation Characteristics by the Changing of Operational Method of Tunnel Fan Shaft Ventilation System for Fire on Subway Train Vehicle (지하철 화재시 본선터널 환기시스템에 따른 열 및 연기배출특성)

  • 이동호;유지오
    • Fire Science and Engineering
    • /
    • v.17 no.2
    • /
    • pp.62-69
    • /
    • 2003
  • The smoke control system in subway platform is not only using for smoke exhaust facility but also using ventilation system. For this reason, smoke vent effectiveness is depending on its position, ventilating volume capacity and the vent method. In this study, the passenger's evacuation time was calculated for the case of fire on sloped subway train vehicle in subway platform. In order to recommend the mechanical smoke exhaust operation mode, SES (Subway Environmental Simulation) was used to predict the airflow of the inlet and outlet tunnel for the subway station. Fire dynamics Simulator(FDS) was used the SES's velocity boundary conditions to calculate the smoke density and temperature under the condition of fire on stopped subway train vehicle at the platform. We compared smoke density and temperature distributions for each 6 types of smoke exhaust systems to clarify the characteristics of smoke and hot air exhaust effectiveness from the result of fire simulation.

Design of Optimized Multi-Fuzzy Controllers for Air-Conditioning System with Multi-Evaporators (다중 증발기를 갖는 에어컨시스템에 대한 최적화된 Multi-Fuzzy 제어기 설계)

  • Jung, Seung-Hyun;Choi, Jeoung-Nae;Oh, Sung-Kwun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.1
    • /
    • pp.7-12
    • /
    • 2007
  • In this paper, we introduce an approach to design multi-fuzzy controllers for the superheat and the low pressure that have an influence on energy efficiency and stabilization of aft conditioning system. Air conditioning system is composed of compressor, condenser several evaporators and several expansion valves. It is quite difficult to control the air conditioning system because the change of the refrigerant condition give an impact on the overall air conditioning system. In order to solve the drawback, we design multi-fuzzy controllers which control simultaneously both three expansion valve and one compressor for the superheat and the low pressure of air conditioning system. The proposed multi fuzzy controllers are given as two kinds of controller types such as a continuous simplified fuzzy inference type and a discrete fuzzy lookup_table type. Here the scaling factors of each fuzzy controller ate efficiently adjusted by veal coding type Genetic Algorithms. The values of performance index of the conventional type are compared with the simulation results of discrete lookup_table type and continuous simplified inference type.

An analysis on the utility of congealing water to improve efficiency of the air cooling equipment and save energy (냉방설비 성능개선 및 에너지 절약을 위한 응결수 활용성 분석)

  • Park, Keun-Soo;Park, Young-Ho;Yu, Jeong-Beom
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.974-981
    • /
    • 2007
  • Seoul Metro has operated the air cooling equipment established in a machine room of a station building to improve our services focused on our customers who use Seoul Metro during the summer season. However, a new set of problems has arisen with the cooling tower to support a heat exchange of cooling water. One of them is loss of efficiency in the air conditioner. The leading cause of this problem is that we use an underground type of the cooling tower. As the machine room of a station building is located in the underground of inner city because of the nature of the subway, it is difficult to establish the cooling tower on the ground. The underground structure of the No. $1{\sim}4$ subway line is unsuitable for the location requirements of the underground type of the one because it has a limited space to set up the air cooling equipment, for example, the cooling tower and a ventilating opening. As a result of such an unfavorable condition, the cooling tower doesn't work efficiently and the warmth of cooling water because of insufficiency of a heat exchange and a refrigerator's technical obstacle such as a high-temperature and a high-pressure has arisen. Accordingly, the efficiency of the air conditioning is getting lower and lower. Another problem is too wasteful with water. Each station uses the water over 30 tons every day with waterworks to replenish the cooling tower such as a evaporation, a scattering and a distribution of water. Nevertheless, the more an air conditioner increase, the more the use of water supply increase. For this reason, we can't help wasting an enormous amount of water and discharging the congelation of a low temperature(about $15^{\circ}C$) occurred in a heat exchanger inside an air conditioner. The purpose of this study is to analyze the utility of congealing water to improve efficiency of the air cooling equipment and save energy as a supplementary water for the cooling tower.

  • PDF

The Characterization of Carbonyl Compounds in the Newly-Built Schools, Daegu City (대구지역 신축학교 실내공기 중 카보닐화합물의 농도 특성 평가)

  • Hwang, Yoon-Jung;Park, Hee-Sun;Jang, Seong-Il;Roh, Ki-Cheul;Son, Tae-Jung;Han, Jeong-Wook;Bae, Gi-Soo;Choi, Im-Jo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.831-841
    • /
    • 2006
  • The study on school indoor air quality was carried out at classrooms, computer-rooms, laboratories and play- grounds for carbonyl compounds including formaldehyde during the winter time from November to December 2004 and during the summer time from June to July 2005. The sampling was conducted under the general school condition without any artificial intervention such as the sealing, ventilating or heating at indoor environments. The concentrations of formaldehyde at all types of indoor environments were lower than air quality standard of $120{\mu}g/m^3$ for public facilities. The mean concentrations of formaldehyde at indoors were $4.5{\sim}6.1$ times higher than those at outdoors. From the comparison between two year and one year old schools after construction, the concentrations of formaldehyde in two year old school were $30{\sim}38%$ lower than those in one year old school measured at classrooms and laboratories.

A Study on the Activity of Health Management in Small Scale Industries (소규모 사업장 보건관리 지도내용 분석)

  • Kim Myung Soon;Lee Myung Sook;Kim Hyun Li;Cho Yoo Hyang
    • Journal of Korean Public Health Nursing
    • /
    • v.12 no.2
    • /
    • pp.12-26
    • /
    • 1998
  • The occupational health problems are the major issue in the modern industrial society. Especially the small scale industries have many hazardous factors and not any occupational health programs in itself. Fortunately. the government-funded subsidiary program was developed and carried out in the past six years in our country. The purposes of this study were to find out the actual condition of the occupational health personnel's accomplishments for the government-funded subsidiary program for small scale industries and to provide basic data for setting up more developed subsidiary occupational health program. Data were collected through 6 kinds of service records review. These service records were written by 3 occupational health personnels were attached to the one subject center of KIHA. were undertaken during March to December, 1997. at 95 small scale industries which were applied the government-funded subsidiary occupational health program. Results were as follows 1. Concerning 95 small scale industries showed characteristics of a typical small scale industry. 2. A doctor visited in industries total 190 times per year, average 19 industries per month, twice per year and industry. A hygienist visited in industries total 378 times per year, average 38 industries per month, four times per year and industry. A nurse visited in industries total 477 times per year. average 47 industries per month, 5 times per year and industry. 3. 3 occupational health personnels accomplished total 3,869 items. A doctor accomplished total 539 items per year, each time 3 items In an industry. A hygienist accomplished total 1.581 items per year, each time 4 items in an industry. A nurse accomplished total 1.749 items per year, each time 4 items in an industry. 4. The major contents of doctor's accomplishment were 'health consultation for suspicious worker with general & occupational disease', 'a check of the workplace & special health education', 'guidance of special medical examination in the second half of year', etc. The major contents of hygienist's accomplishment were 'pretest & guidance of planning for evaluation of working environment'. 'evaluation for ventilating facilities & suporting self inspection', 'guidance of MSDS recording & chemicals management', etc. The major contents of nurse's accamplishment were 'health counseling of general & special medical examination results'. 'health education of preventing occupational disease & health disorder'. 'guidance of subsidiary program planning', 'selecting & guidance of health monitor', etc. It was concluded that the occupaional health personnels implemented the subsidiary program according to the order of health management guide. The current health management guide of subsidiary occupational health program in which the fixed contents, visiting number & periods is not desirable. That guide is left the characteristics of small scale industries out of consideration. It is suggested that occupational health management guide should be developed according to the general & environmental characteristics of each small scale industry, and on the other hand, the more specific guide for each occupational health personnel should be developed.

  • PDF