• Title/Summary/Keyword: Ventilated Roof

Search Result 6, Processing Time 0.02 seconds

Analysis on Internal Airflow of a Naturally Ventilated Greenhouse using Wind Tunnel and PIV for CFD Validation (CFD 검증을 위한 풍동 및 PIV를 이용한 자연환기식 온실 내부 공기유동 분석)

  • Ha, Jung-Soo;Lee, In-Bok;Kwon, Kyeong-Seok;Ha, Tae-Hwan
    • Journal of Bio-Environment Control
    • /
    • v.23 no.4
    • /
    • pp.391-400
    • /
    • 2014
  • The number of large scale greenhouses has recently been increasing to cope with mass consumption of agricultural product. Korean government announced a new development plan for constructing greenhouse complex in reclaimed lands for the purpose of improvement in exports and activation of domestic market of agricultural product. Wind environment in the reclaimed land is totally different from that of inland area, and it can give a strong influence on ventilation performance of naturally ventilated greenhouse facilities. In this study, internal airflow analysis of naturally ventilated greenhouse built on a reclaimed land was conducted using wind tunnel and PIV for validation research. Later, the PIV measured results will be used to improve the accuracy of 3 dimensional CFD simulation in the future. Wind profile at a reclaimed land was produced using ESDU program and it was applied to the wind tunnel. The calculated error was only 5% and 0.96 of correlation coefficient, implying that the computed profiles were designed properly. From the measured results, when external wind speed changed from $1m{\cdot}s^{-1}$ to $1.5m{\cdot}s^{-1}$, air velocities inside the greenhouse which PIV measured were also increased proportionately in case of both side vent open and side-roof vent open. Considering reduced ratio of air velocity inside the greenhouse, it was measured a minimum of 40% in case of side vent and 30% in case of side-roof vent compared with external wind speed from each vent type. From the quantitative and qualitative PIV analysis, the PIV measured results indicated that there were well ventilated and stagnant areas in the greenhouse according to external wind condition as well as ventilation design.

Predictive Model of Micro-Environment in a Naturally Ventilated Greenhouse for a Model-Based Control Approach (자연 환기식 온실의 모델 기반 환기 제어를 위한 미기상 환경 예측 모형)

  • Hong, Se-Woon;Lee, In-Bok
    • Journal of Bio-Environment Control
    • /
    • v.23 no.3
    • /
    • pp.181-191
    • /
    • 2014
  • Modern commercial greenhouse requires the use of advanced climate control system to improve crop production and to reduce energy consumption. As an alternative to classical sensor-based control method, this paper introduces a model-based control method that consists of two models: the predictive model and the evaluation model. As a first step, this paper presents straightforward models to predict the effect of natural ventilation in a greenhouse according to meteorological factors, such as outdoor air temperature, soil temperature, solar radiation and mean wind speed, and structural factor, opening rate of roof ventilators. A multiple regression analysis was conducted to develop the predictive models on the basis of data obtained by computational fluid dynamics (CFD) simulations. The output of the models are air temperature drops due to ventilation at 9 sub-volumes in the greenhouse and individual volumetric ventilation rate through 6 roof ventilators, and showed a good agreement with the CFD-computed results. The resulting predictive models have an advantage of ensuring quick and reasonable predictions and thereby can be used as a part of a real-time model-based control system for a naturally ventilated greenhouse to predict the implications of alternative control operation.

Evaluation of Computational Fluid Dynamics for Analysis of Aerodynamics in Naturally Ventilated Multi-span Greenhouse

  • Lee, In Bok;Short, Ted H.;Sase, Sadanori;Lee, Seung Kee
    • Agricultural and Biosystems Engineering
    • /
    • v.1 no.2
    • /
    • pp.73-80
    • /
    • 2000
  • Aerodynamics in a naturally ventilated multi-span greenhouse with plants was analyzed numerically by the computational fluid dynamics (CFD) simulation. To investigate the potential application of CFD techniques to greenhouse design and analysis, the numerical results of the CFD model were compared with the results of a steady-state mass and energy balance numerical model. Assuming the results of the mass and energy balance model as the standard, reasonably good agreement was obtained between the natural ventilation rates computed by the CFD numerical model and the mass and energy balance model. The steady-state CFD model during a sunny day showed negative errors as high as 15% in the morning and comparable positive errors in the afternoon. Such errors assumed to be due to heat storage in the floor, benches, and greenhouse structure. For a west wind of 2.5 m s$^{-1}$ , the internal nonporous shading screens that opened to the east were predicted to have a 15.6% better air exchange rate than opened to the west. It was generally predicted that the presence of nonporous internal shading screens significantly reduced natural ventilation if the horizontal opening of the screen for each span was smaller that the effective roof vent opening.

  • PDF

Investigations and Analyses of Duck Breeding Facilities in Jeollanam-do Province, Korea (전남지역 오리 사육시설 실태 조사 및 분석)

  • Kwon, Kyeong-seok;Yang, Kayoung;Kim, Jong-bok;Kim, Jung-kon;Jang, Donghwa;Choi, Sungmin;Lee, Sang-yeon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.1
    • /
    • pp.1-9
    • /
    • 2021
  • Number of duck and its breeding facilities have been steadily decreasing for financial and social issues in Korea. Therefore, the 'turning point' for duck industry is strongly demanded. In this study, the questionary survey was carried out to provide backgrounds for developing policy and technology for duck breeding farms. The questionary survey aimed to investigate the information of operation strategy of farm, ventilation, cooling and heating. The total number of survey respondents was 74. In case of facility type, 55.4% of respondents stated they used greenhouse type, 31.3% for winch-curtain type, and 2.7% for windowless type (mechanically ventilated facility). More than 85% of the facilities were using 'natural ventilation', it meant that these situation can restrict the not only environmental control but also the supply policy for 'smart farm' of the Government. 44.6% used the combination of the cross-ventilation method and roof-ventilation method for ventilation operation in summer season, and 31.1% followed only the cross-ventilation method. In case of winter season, 36.5% used the cross-ventilation method, and 33.3% used the combination of cross and roof-ventilation, method. For the ventilation strategy, about 86.5% depended on farmer's experience. In case of heating and cooling, 79.7% were using kerosene heater for winter season, and 43.2% were using mist-spray for summer season, respectively. More than 75% stated that cooling and heating strategies were based on farmer's experience. From the analyses of the survey results, a few proposals for developing policy and technology for duck breeding farm was suggested.

Effects of an Improved Side Vent on Yield of Oriental Melon and Temperature in Single-span Plastic Greenhouse with Roof Ventilation Fans (지붕 환기팬이 설치된 단동 플라스틱 온실에서 개선된 측창형태가 하우스 내 온도 및 참외 수량에 미치는 영향)

  • Yu, In Ho;Cho, Myeong Whan;Ryu, Hee Ryong;Shin, Young An
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.283-290
    • /
    • 2017
  • In this study, the method to attach plastic film on the side vent from inside of greenhouse for the entire length was developed as the way to make crops less stressful while uniformly getting outside air into the greenhouse when ventilating using roof ventilation fans at single-span plastic greenhouse for oriental melon in a low-temperature period. The plastic film was installed from ground to 10cm below from the height where side vent is fully opened. In order to verify that the improved side vent can improve greenhouse environment and fruit yield, it was compared with the control plot of conventional side vent. Both greenhouses were not ventilated until February 25th, 2017. Air temperature in both greenhouses exceeded $40^{\circ}C$ in mid February. Therefore, it is judged that the greenhouse should be ventilated from mid February. Air temperature in the control plot exceeded $30^{\circ}C$ from late April. Therefore, it is judged that the plastic film attached to the inside of side vent should be removed in late April, or in early May at the latest. Soil temperature in the treatment plot in the mid Aril exceeded $20^{\circ}C$, which is suitable for growth, while that in the control plot was still below $20^{\circ}C$. Soil temperature in the control plot finally exceeded $20^{\circ}C$ in late April. The consumption of electricity was 47.2 kWh in the treatment plot, and 48.3 kWh in the control plot, which was no significant difference. The marketable yield of oriental melon in the treatment plot was 5,094kg, which was 23.9% more than that in the control plot, 4,113kg. The marketable fruit ratio was 73.5% in the treatment plot, and that in the control plot was 73.9%, which was no significant difference.

Actual Utilization and Thermal Environment of Greenhouses According to Several Cooling Methods during Summer Season (하절기 온실의 활용실태 및 몇 가지 고온극복 방법별 열환경 분석)

  • 남상운
    • Journal of Bio-Environment Control
    • /
    • v.9 no.1
    • /
    • pp.1-10
    • /
    • 2000
  • This study was performed to find an efficient method to overcome extremely high temperature in greenhouses during summer season. The actual utilization of greenhouses during hot summer season showed that about 21.6% of the investigated greenhouse farms were in fallow state, and most of greenhouse farms were cultivated under the very inferior environment. Thermal environment of greenhouses according to the evaporative cooling method and several assistant cooling methods such as ventilation, shading screen, roof sprinkling were examined. As the each assistant cooling method was used, about 74.8%, 25.9%, and 58.2% of temperatures measured at intervals of ten minutes between ten and seventeen o'clock were above 35$^{\circ}C$. When shading screen and evaporative cooling system were operated, most greenhouse air temperatures were maintained below 35$^{\circ}C$, and showed a drop of 3.8~4.2$^{\circ}C$ as compared with naturally ventilated greenhouse.

  • PDF