• Title/Summary/Keyword: Vent grille

Search Result 3, Processing Time 0.022 seconds

The Development of an Automation Jig for the Vent Grille Assembly Process (벤트 그릴 조립공정 자동화를 위한 자동화지그 개발)

  • Kim Jin-Woo;Park Bum-Seok;Han Chang-Soo
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.5
    • /
    • pp.87-92
    • /
    • 2005
  • In this study, an automation assembly jig for the automation assembly process for the ventilation grille that is used in the interior of a car Is developed. As the method that can do the automation assembly for the ventilation grille, a simple jig and air cylinder have been applied. And a solenoid valve, a filter regulator, and on-off switch have been used in controlling the system. Moreover, the timer is attached to the equipment so that a worker may control the assembly time, as fitting the quantity on demand of production. Actually with executing the assembly test productivity and performance of assembly have been verified. In case of the automation assembly work for a ventilation grille is compared to the manual work. The optimum working speed has been identified to make the process twice or three times better.

The Development of an Automation Jig for the Vent Grille Assembly Process (벤트 그릴 조립공정 자동화를 위한 자동화 지그 개발)

  • 김진우;한창수
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.77-82
    • /
    • 2000
  • In this study, an automation assembly jig for the automation assembly process for the ventilation grille that is used in the interior of a car is developed. As the method that can do the automation assembly for the ventilation grille, a simple jig and air cylinder have been applied. And a solenoid valve, a filter regulator, and on-off switch have been used in controlling the system. Moreover, the timer is attached to the equipment so that a worker may control the assembly time, as fitting the quantity on demand of production. Actually with executing the assembly test productivity and performance of assembly have been verified. In case of the automation assembly work for a ventilation grille is compared to the manual work. The optimum working speed has been identified to make the process twice or three times better.

  • PDF

Analysis of Indoor Air & thermal environment with Hybrid Ventilation system during summer (하계 공동주택 하이브리드 환기시스템 적용에 따른 실내공기 및 열 환경 평가)

  • Kim, Sang-Jin;Kim, Eun-Soo;Kim, Tae-Yeon;Leigh, Seung-Bok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.387-392
    • /
    • 2006
  • The recent on indoor air problem has led to many studies on the methods and effects of ventilation for better indoor air quality. Although natural ventilation is the most effective and energy-saving method in residental housings, the small size of openable window has been a problem in high-rise residential buildings to ventilate only through natural ventilation. Consequently, the installation of mechanical ventilation system has been a requirement in residential buildings, and has caused other problems such as increase of energy consumption and SBS. Hybrid ventilation which uses forces of both natural and mechanical power has been introduced to solve the problem of increase in energy consumption with natural ventilation. In this paper, two types of hybrid ventilation systems in residential building were introduced. One type was with natural ventilation through vent grille in the window, and another type was with natural ventilation through ceiling duct while both types used mechanical ventilation system with the outlets. The indoor temperature distribution and pollution density distribution in summer while operating the ceiling air conditioner were analyzed through CFD simulation. In this paper, the optimal location of diffusers to achieve thermal comfort would be proposed.

  • PDF