• 제목/요약/키워드: Vent control

검색결과 84건 처리시간 0.022초

물류창고의 배연설비 기준 개선을 위한 국내·외 배연설비의 설계 방법에 따른 연기하강시간 예측에 관한 연구 (A Study on the Prediction of Descending Smoke Time according to the Design Method of Domestic and Foreign Smoke Facilities for the Improvement of Smoke Facilities Standards in Logistics Warehouse)

  • 허예림;김윤성;진승현;구인혁;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.141-142
    • /
    • 2022
  • Recently, fires in logistics warehouses in Korea are continuously increasing. In addition, the need for fire safety in logistics warehouses is emerging. So, it is believed that it is necessary to establish standards for vent facilities under effective smoke control for the evacuation safety of residents in logistics warehouses. Therefore, this paper compares the standards related to combustion facilities in Korea, the United States, and Japan, and applies the design method to logistics warehouses of domestic materials to predict smoke drop time and use it as a basic data for improving domestic smoke facilities standards.

  • PDF

단동 비닐하우스의 지붕 환기장치 설치방법 개선이 참외생육 및 과실수량에 미치는 영향 (Effects of Modified Installation Methods of Roof Ventilation Devices in the Single-span Plastic Greenhouses on Yield and Fruit Quality of Oriental Melon)

  • 여경환;유인호;최경이;이성찬;이재한;박경섭;이중섭
    • 생물환경조절학회지
    • /
    • 제25권4호
    • /
    • pp.334-342
    • /
    • 2016
  • 지붕 환기장치 설치방법의 개선에 의한 작물 재배효과를 검증하고자 농가현장에서 개선 지붕 환기방식과 관행환기방식을 비교, 분석하였다. 개선 지붕 환기방식은 참외재배 단동 플라스틱 온실(폭 5.6m, 길이 108m, 측고 1.1m, 동고 2.2m)에 지붕 환기팬(용량 $38m^3/min$)과 환기통(지름 60cm)을 각각 15m와 6m 간격으로 설치하였고, 대조구로서 관행 지붕 환기방식은 각각 20m와 8m 간격으로 설치하였다. 관행 및 개선 지붕 환기 방식에 따른 생육을 조사한 결과, 관행 환기통과 환기팬 처리에 비해 개선 환기통과 개선 환기팬 처리에서 경경, 엽장, 엽병장, 및 엽폭의 값이 낮게 나타나는 경향을 보였다. 생육기 전반부에 관행 환기통 처리는 환기팬 처리에 비해 절간장이 다소 길게 발달하였는데 이는 착과수가 환기팬 처리에 비해 적었고, 착과수 감소로 인해 동화산물이 잎과 줄기의 신장부로 좀 더 이동된 영향으로 판단되었다. 참외재배 단동 비닐하우스에서 과실 수량을 조사한 결과, 개선 환기팬과 개선 환기통 처리는 관행처리에 비해 과중은 약간 작았지만, 착과수 증가로 인해 전체 수량은 높게 나타났다. 개선 환기팬과 개선 환기통 설치 하우스에서는 관행 지붕 환기 하우스에 비해 상품과율이 높았으며, 10a당 상품수량도 각각 8,391kg, 7,283kg 으로 나타나 관행 지붕 환기에 비해 개선 환기팬 처리는 661kg, 개선 환기통 처리는 487kg 더 증가하였다. 개선 환기팬 처리는 고온기에 암꽃수와 착과수가 가장 많았고, 낙과수는 가장 낮게 나타났으며, 관행의 환기통 처리에 비해 과실의 크기는 작았다. 시기별 환기방식에 따른 참외 과실의 품질을 조사한 결과, 관행 환기통 환기에서 과중, 과경, 과폭, 및 과육두께가 가장 높게 나타났으나, 과폭, 과육두께에 있어서 통계적인 유의차는 나타나지 않았다.

발전소 스팀제어용 유압서보 액추에이터의 씰 수명 향상에 관한 연구 (A Study on the Seal Life Improvement of the Hydraulic Servo Actuator for Steam Control of Power Plants)

  • 이용범;이종직
    • 드라이브 ㆍ 컨트롤
    • /
    • 제15권2호
    • /
    • pp.32-37
    • /
    • 2018
  • The power plants use turbine output control devices to supply or shut off steam to high pressure and low-pressure steam turbines connected to generators. This turbine output control device is driven by a hydraulic servo actuator. The gas flows into the hydraulic servo actuator during periodic inspection or normal operation, and the resulting adiabatic compression of the gas raises the internal temperature of the actuator to $500^{\circ}C$. This temperature increase causes the seals to burn and show wear and tear, resulting in failure. In this study, an air vent valve was installed to allow gas inside the hydraulic servo actuator to flow large quantities of air at the beginning of the operation and after the periodic inspection. Gas was passed through for only minute flow during normal operation of the power plant. By applying the air vent valve, it improves the reliability of the hydraulic servo actuator by discharge the gas appropriately to improve the life of the seal.

Greenhouse Control with PV System

  • Kim, Kee Hwan
    • International Journal of Advanced Culture Technology
    • /
    • 제1권1호
    • /
    • pp.6-10
    • /
    • 2013
  • The greenhouse control system for educational purpose is designed by personal computer. This system should observe and control the growth conditions for crops in both plastic film and glass greenhouses. In this contribution puts emphasis on construction of greenhouse control system by personal computer under the aim of creating safer, more effective and more economical services. This system is developed for the requirements of the intelligent greenhouse control system and is powered by solar energy. A photovoltaic system with sun tracking module is used for the greenhouse control system.

  • PDF

플라스틱 단동온실의 천창 종류에 따른 자연환기 효과 (Efficiency of Different Roof Vent Designs on Natural Ventilation of Single-Span Plastic Greenhouse)

  • 라쉬드아드난;이종원;김현태;이현우
    • 생물환경조절학회지
    • /
    • 제28권3호
    • /
    • pp.225-233
    • /
    • 2019
  • 여름철에 자연환기는 온실의 온도를 낮추는데 중요한 역할을 한다. 온실의 형태, 환기창 종류, 환기창의 위치 등은 자연환기 성능에 큰 영향을 미친다. 본 연구에서는 전산유체역학(CFD)을 이용하여 다양한 천창구조에 대하여 측창에 따른 부력환기 효과를 비교분석 하였다. Boussinnesq 가정을 사용하여 전체 계산영역에 대한 부력효과를 시뮬레이션 하였다. 또한 RNG $K-{\varepsilon}$ 난류모델을 사용하였다. 일사량 효과를 시뮬레이션 하기 위해 Solar ray tracing과 함께 Discrete originates (DO) radiation 모델을 사용하였다. 실험온실 내부의 온도를 측정하여 CFD모델을 검증하였으며, 실험값과 계산값이 잘 일치하는 것으로 나타났다. 7가지의 천창구조에 대하여 온실의 내외부 온도차이와 환기횟수를 비교하였다. 내외부온도의 차이는 $3.2{\sim}9.6^{\circ}C$ 범위로 나타났고, 환기횟수는 $0.33{\sim}0.49min^{-1}$ 범위로 나타났다. 고깔형 천창구조 온실의 경우 내외부 온도차이가 $3.2^{\circ}C$로 가장 낮았고 환기횟수도 $0.49min^{-1}$로 가장 높게 나타나 환기효과가 가장 우수한 것으로 나타났다.

중형 상용차 통풍형 브레이크 디스크의 제동 시 열 유동 및 변형 해석 (Thermal Fluid Flow and Deformation Analysis of Medium Commercial Vehicle Ventilated Brake Disc in Braking)

  • 강채욱;최규재
    • 한국자동차공학회논문집
    • /
    • 제22권7호
    • /
    • pp.63-69
    • /
    • 2014
  • Domestic automobile companies have adopted drum type brake system for commercial vehicles. However recently those companies have been applying disc-brake system to solve vehicle control-instability and inefficient heat discharge performance of conventional drum brake system for a medium commercial vehicle. Because the kinetic energy of a running commercial vehicle is relatively high, the brake system should discharge lots of heat energy while braking. A ventilated type brake disc has been used to increase heat discharge performance of a brake system. The vent structure of a disc highly affects cooling efficiency. This paper compares thermal characteristics of three types of vent structure in JASO C421 braking condition. It is found that the slant bend type disc has the lowest temperature and thermal stress distributions in the braking condition.

카본블랙 제조공정의 안전성 향상에 관한 연구 (A Study on the Safety Improvement of Carbon Black Manufacturing Process)

  • 주종율;정필훈;이성은
    • 대한안전경영과학회지
    • /
    • 제25권4호
    • /
    • pp.153-161
    • /
    • 2023
  • Carbon black is a material in the form of fine black powder obtained by incomplete combustion or pyrolysis of hydrocarbons, and is composed of 90-99% carbon, and the rest is composed of hydrogen and oxygen. In the event of an emergency during the manufacture of carbon black, the generated tail gas should be safely discharged through an emergency line to prevent fire, explosion, and environmental pollution accidents caused by the tail gas. If the pressure continues to rise, the pressure control valve shall operate and the rupture plate shall be ruptured sequentially and the tail gas shall be discharged to the vent stack through the emergency line. As an emergency emission system, even if some untreated substances in the tail gas are released into the atmosphere, they are lighter than air, so it is safe to discharge them to a safe place through the Vent Stack. If the gas pressure is rising or worse, it is discharged from the Vent Stackine, and discharging fuel.

스프링클러와 배연설비의 통합작동이 수평통로의 연기제어에 미치는 영향 (The Effect of the Combined Operation of Sprinkler and Vent Systems on the Smoke Control in a Horizontal Corridor)

  • 전흥균;최영상;추홍록;장준영
    • 한국화재소방학회논문지
    • /
    • 제19권1호
    • /
    • pp.70-89
    • /
    • 2005
  • 수평통로의 천장 아래로 확산되는 연기의 냉각 및 차단을 위해 설치한 스프링클러와 배연설비의 통합작동이 유동장의 온도 및 연기밀도 분포에 미치는 영향을 조사하기 위해 $20.0m\;\times\;4.0m\;\times\;3.0m$ 크기의 공간에 대해 전산유체역학 프로그램(FDS 4.0.3)의 화재모의실험을 수행하였다. 연기의 냉각 및 차단효과는 스프링클러와 배연설비의 통합작동이 단독작동 보다 더 우수한 것으로 확인되었고, 천장에 설치되는 스프링클러헤드는 천장 길이방향으로의 모서리 효과에 의해 작동 헤드수는 2개로 제한되었으며, 적정 헤드수를 초과한 헤드설치는 오히려 연기냉각 및 차단 효과를 저하시키는 것을 확인할 수 있었다. 본 연구에서는 2개의 헤드설치와 $3.0m^3/s$의 배연량인 경우 연기의 냉각 및 차단효과가 가장 좋았다. 헤드 작동 시 연기 하향끌림 현상이 발생하며, 화재크기의 증가로 연기발생 량이 배연 량 보다 큰 경우에는 연기 하향끌림 현상이 훨씬 더 크게 나타남을 확인할 수 있었다.

배연창 크기와 스프링클러 작동이 인명안전에 미치는 영향 연구 (A Study on the Effectiveness to the Life Safety by Enlarging Smoke Vent Size and/or Sprinklered System)

  • 김학중;박용환;임채현;김범규
    • 한국화재소방학회논문지
    • /
    • 제24권2호
    • /
    • pp.133-138
    • /
    • 2010
  • 최근 건축물이 대형화, 복잡화되면서 건축물내 거주자의 피난안전성이 관심의 초점이 되고 있다. 국내 건축물은 용도에 따라 관계법령에 의한 배연창 또는 기계적 배연설비를 설치하도록 규정되어 있다. 화재시 거주자의 피난안전성을 확보하기 위하여 화재실의 제연이 매우 중요하다. 본 연구에서는 배연창 크기의 변화와 스프링클러 설비의 작동이 화재실 연기층 높이와 온도 조건에 미치는 영향을 화재 시뮬레이션프로그램인 CFAST를 이용하여 평가 하였다. 연구결과 배연창 면적이 증가할수록 5MW 화재 크기 이하에서는 연기층 높이와 온도에 미치는 효과가 증가하나 화재크기가 10MW 이상 커지면 배연창의 면적과 연기배출 효과와의 상관성이 떨어진다. 스프링클러 설비가 작동하고 배연창이 열릴 경우에는 화재크기와 상관없이 인명안전기준이 만족되었다. 법규에 의한 일률적인 배연창 면적의 적용보다는 건축물의 용도 및 규모에 따라 화재시나리오를 선정하고 시나리오에 따른 화재 크기에 따라 적절한 크기의 배연창을 적용하여야 하며 실제 실험이나 시뮬레이션을 통한 검증이 이루어져야 한다.

멤브레인형 LNG선박 화물탱크 벤트 마스트 출구에서의 BOG 확산 특성에 관한 연구 (An Examination on the Dispersion Characteristics of Boil-off Gas in Vent Mast Exit of Membrane Type LNG Carriers)

  • 강호근
    • 해양환경안전학회지
    • /
    • 제19권2호
    • /
    • pp.225-231
    • /
    • 2013
  • 일반적으로 액체가스운반선은 인화성 화물이나 독성물질을 운반한다. 이러한 화물들은 폭발, 화재 및 인명손상을 가져올 수 있기 때문에, 액체가스운반선의 거주구역, 서비스 구역 및 통제실은 가스의 유입이 원천적으로 차단되도록 설계한다. 이러한 이유로, IMO IGC 코드의 멤브레인형 LNG선박의 화물탱크에 설치되는 벤트 출구의 높이는 노출갑판상 B/3 또는 6m 중 큰 것 이상으로 하고 작업구역 및 전후부 통행로, 갑판상의 저장탱크 및 화물설계 액위보다 6m 이상 높게 설치하여야 한다라고 규정하고 있다. 또한 LNG 시장이 점진적으로 증가하면서, LNG선박의 크기도 증가해 왔다. 때문에 현 규정에 의하면 LNG선박의 벤트의 높이는 선박 폭(B)에 비례하기 때문에 상당히 높아져야 할 것이며, 이는 높은 벤트 마스트(Mast)로 인하여 작업의 어려움 및 전방 시야를 방해하는 등 항해의 어려움을 초래한다. 본 연구에서는 멤브레인형 LNG선의 Sea-trial시에 측정하였던 데이터 및 CFD유동해석을 통해 LNG선박 화물탱크의 벤트 출구의 높이에 대한 적합성 평가를 수행한다.