• Title/Summary/Keyword: Venous pressure

Search Result 213, Processing Time 0.023 seconds

Development of pulse diagnosis possible simulator using the stepper motor pumps (스텝 모터 펌프를 이용한 맥진 가능한 시뮬레이터의 개발)

  • Ryu, Geun-Taek;Woo, Sung-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.915-918
    • /
    • 2016
  • Virtual testing devices are required due to rapid changes in the health care industry and the increase of the medical or nursing workforce. The importance of devices such as the simulator, blood vessels, and lab equipment for modeling blood flow to the heart is increasing too. In this study, we made heart pump by using a step motor and developed device which simulates arterial, venous blood pressure, and blood flow. We finally evaluated the function of proposed device. The proposed system is composed of the pump for simulating, the valve device to describe the resistance of the artery and vein, and a reducing device showing the characteristics of the venous system. We used BOXER pump for heart simulator and silicon tube for arterial and venous vessels, and designed a reducing device. We also used the pressure sensor to measure arterial blood pressure. For the evaluation of the proposed system, we selected a range of 50~100mmHg of the blood circuit 60 per minute and then compared the blood pressure of a person and the measured blood pressure.

  • PDF

Results of Fontan Operation - 45 Cases Report - (Fontan 수술성적에 대한 보고 - 45례 -)

  • 원용순
    • Journal of Chest Surgery
    • /
    • v.22 no.1
    • /
    • pp.25-31
    • /
    • 1989
  • Forty-five patients, aged 16 months to 15.5 years mean 69 months, with a wide variety of cardiac malformations underwent the modified Fontan operation between Sep. 1986 to Aug. 1988. Nineteen patients had previously undergone palliative operations mainly modified B-T shunt. Twenty patients had a mean pulmonary artery pressure greater than 15 mmHg, with nine operative deaths. Thirteen patients had anomalies of systemic venous connection and seven patients had anomalies of pulmonary venous connection. There were eighteen patients under the age 4 years and fifteen of them survived [83.3%]. Eighteen patients had a pulmonary vascular resistance [PVR] more than 2.5U/m, and nine died [50%] whereas two of twenty-three with a PVR less than 2.5U/m died[8.6%]. PVR and anomalies of pulmonary venous connection had a significant influence on survival, but age and anomalies of systemic venous connection did not. Amount of pleural effusion drained postoperatively and PVR had positive linear correlation. Pulmonary artery pressure was not an independent predictor of outcome and pulmonary artery pressure alone should not contraindicate a Fontan procedure if PVR is low. In general, the Fontan operation should be done at a younger age less than 4 year to avoid ventricular dysfunction due to long-standing exposure to hypoxia.

  • PDF

Analysis of Relation between Ventricular Preload and Cardiac Output and Hemodynamic in the Early Postoperative Period of Congenital Heart Surgery (선천성 심장기형 환자에서 조기술후 심실 전부하 용적과 심박출량의 상호 관계 및 혈역학적 변화 분석)

  • Park, Seung-Il;Kim, Eung-Jung;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.23 no.1
    • /
    • pp.22-32
    • /
    • 1990
  • Postoperative cardiac performance of cyanotic congenital heart disease is somewhat different from that of other cardiac diseases. For the evaluation of postoperative cardiac performance in the cyanotic congenital heart disease we measured cardiac output by thermodilution technique at 1, 4, 8, 12, 16, 20, 24, 36, 48 postoperative hours in 14 patients operated from Feb. 1989 to Nov. 1989 in The Department of Thoracic and Cardiovascular Surgery, Seoul National University Children`s Hospital. At the same time, we checked left atrial pressure [LAP], central venous pressure [CUP], and mixed venous oxygen saturation [SvO2] to detect correlation between them. Immediate postoperative cardiac index was 3.585 $\pm$ 0.945 L/min/m2, and it decreased maximally to 3.322$\pm$1.007 L/min/m2 at postoperative 16 hours. After then it increased and stabilized from 36 hours after operation, and its value was 4.426$\pm$1.358 L/min/m2. There were no correlations between cardiac index and left atrial pressure or central venous pressure. Between mixed venous oxygen saturation and cardiac index, there was no correlation in the early postoperative period but after postoperative 16 hours, there was significant correlation between them and correlation coefficients were 0.573 [16hrs], 0.743 [20hrs], 0.436 [24hrs], 0.560 [36hrs], 0.636 [48hrs], respectively. From these results, we concluded that in the corrective surgery of cyanotic congenital heart disease, cardiac performance was depressed in the early postoperative period. It improved from postoperative 16 hours, and stabilized from 36 hours after operation. During early postoperative period, mixed venous oxygen saturation should not be used as a predictor of cardiac performance but it could be used as a predictor of cardiac performance from 16 hours after operation.

  • PDF

Analysis of Relationship between Mixed Venous PO2 and Status of Cardiac Performance with Hemodynamic Values after Correction of Cyanotic Congenital Heart Disease (청색심기형 교정술후 혼합정맥혈 산소분압과 심근상태 및 혈류역학치와의 상관관계 분석)

  • An, Jae-Ho;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.22 no.2
    • /
    • pp.212-219
    • /
    • 1989
  • We utilized pulmonary artery pressure monitoring system in risky patients for preventing the postoperative pulmonary hypertensive crisis and for sampling the mixed venous blood. And this mixed venous blood oxygen saturation [MVSO2] or partial pressure [MVPO2]tells us many meaningful patients state. We selected 59 cyanotic congenital heart diseased patients, who were operated in our hospital from Nov. 1987 to Oct. 1988, in the Department of Thoracic and Cardiovascular Surgery, Seoul National University Children\ulcorner Hospital, who had pulmonary artery pressure monitoring catheter and who made us know their mixed venous oxygen condition. We found that there was no close relationship between MVPO2 and Cardiac Index [C.I.] during early postoperative period, but on the first and second day after operation the correlation coefficient was increased as r=0.35[p=0.008], r=0.78[p=0.0001]. So we concluded that the correlation between MVPO2 and C.I. was more reliable with time going as hemodynamic stabilization. And we experienced no survivors whose MVPO2 was under 20 torr, but that was not the only factor for death. From these results, we conclude that we can consider the MVPO2 [or MVSO2] representing C.I. after stabilized postoperative condition of the open heart surgery patients, but during early postoperative period, in addition to this MVPO2, we should do also apply other parameter such as urine output, arterial blood pressure, left atrial pressure and pulmonary arterial pressure for exact estimation of the patients status.

  • PDF

Impact of Complex Hemodynamics to the Management of ArterioVenous(AV) Fistula (동정맥루의 복합성 혈류학 소견이 그 관리에 미치는 영향)

  • Lee Byung-Boons
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.9-10
    • /
    • 2002
  • Human circulatory system between heart and tissue is not directly connected in normal condition but mandatory to go through the capillary system in order to fulfill its physiologic aim to deliver oxygen and nutrients, etc. to the tissue and retrieve used blood together with waste products from the tissue properly. When abnormal connection between arterial and venous system (AV fistula), these two circulatory systems respond differently to the hemodynamic impact of this abnormal connection between high pressure (artery) and low pressure (vein) system. Depending upon the location and/or degree (e.g. size and flow) of fistulous condition, each circulatory system exerts different compensatory hemodynamic response to this newly developed abnormal inter-relationship between two systems in order to minimize its hemodynamic impact to own system of different hemodynamic characteristics. Pump action of the heart can assist the failing arterial system directly to maintain arterial circulation against newly established low peripheral resistance by the AV fistula during the compensation period, while it affects venous system in negative way with increased venous loading. However, the negative impact of increased heart action to the venous system is partly compensated by the lymphatic system which is the third circulatory system to assist venous system independently with different hemodynamics. The lymphatic system with own unique Iymphodynamics based on peristaltic circulation from low resistance to high resistance condition, also increases its circulation to assist the compensation of overloaded venous system. Once these compensation mechanisms should fail to fight to newly established hemodynamic condition due to this abnormal AV connection, each system start to show different physiologic ${\underline{de}compensation}$ including heart and lymphatic system. The vicious cycle of decompensation between arterial and vein, two circulatory system affecting each other by mutually negative way steadily progresses to show series of hemodynamic change throughout entire circulation system altogether including heart. Clinical outcome of AV fistula from the compensated status to decompensated status is closely affected by various biological and mechanical factors to make the hemodynmic status more complicated. Proper understanding of these crucial biomechanical factors iii particular on hemodyanmic point of view is mandatory for the advanced assessment of biomechanical impact of AV fistula, since this new advanced concept of AY fistula based on blomechanical information will be able to improve clinical control of the complicated AV fistula, either congenital or acquired.

  • PDF

Effects of Potassium Ion Concentrations on the Cardiac Performances in the Turtle Heart Amyda japonica (자라 심장 박출량과 $K^{+}$ 농도)

  • Kim, Jun;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.14 no.1
    • /
    • pp.31-39
    • /
    • 1980
  • Changes in cardiac performances were observed under variations of the arterial and/or venous pressures with K-loading or K-depletion in turtle heart. Hearts were perfused with turtle Ringer-Locke's solutions containing various levels of potassium ion concentration. When venous pressure increased from 4 to 12 cm $H_2O$, cardiac output increased from $6.2{\pm}0.68$ to $15.7{\pm}0.75\;ml/min$, concomittantly. On the contrary, cardiac output decreased during the elevation of arterial pressure. Stroke work increased more prominently during the arterial pressure elevation than during the elevation of venous pressure. During K-depletion$(1{\sim}2mEq/L)$, cardiac output increased to two times that of normal K-concentration$(3{\sim}6\;mEq/L)$ group. Heart rate increased also, but less markedly. In K-loaded$(7{\sim}8\;mEq/L)$ group, both the cardiac output and heart rate decreased but stroke volume rather increased, because heart rate decrement was disproportionate to that of cardiac output. We concluded that in perfused turtle heart, cardiac output variation was more sensitive to K_depletion whereas heart rate to K-loading.

  • PDF

Prediction of Venous Trans-Stenotic Pressure Gradient Using Shape Features Derived From Magnetic Resonance Venography in Idiopathic Intracranial Hypertension Patients

  • Chao Ma;Haoyu Zhu;Shikai Liang;Yuzhou Chang;Dapeng Mo;Chuhan Jiang;Yupeng Zhang
    • Korean Journal of Radiology
    • /
    • v.25 no.1
    • /
    • pp.74-85
    • /
    • 2024
  • Objective: Idiopathic intracranial hypertension (IIH) is a condition of unknown etiology associated with venous sinus stenosis. This study aimed to develop a magnetic resonance venography (MRV)-based radiomics model for predicting a high trans-stenotic pressure gradient (TPG) in IIH patients diagnosed with venous sinus stenosis. Materials and Methods: This retrospective study included 105 IIH patients (median age [interquartile range], 35 years [27-42 years]; female:male, 82:23) who underwent MRV and catheter venography complemented by venous manometry. Contrast enhanced-MRV was conducted under 1.5 Tesla system, and the images were reconstructed using a standard algorithm. Shape features were derived from MRV images via the PyRadiomics package and selected by utilizing the least absolute shrinkage and selection operator (LASSO) method. A radiomics score for predicting high TPG (≥ 8 mmHg) in IIH patients was formulated using multivariable logistic regression; its discrimination performance was assessed using the area under the receiver operating characteristic curve (AUROC). A nomogram was constructed by incorporating the radiomics scores and clinical features. Results: Data from 105 patients were randomly divided into two distinct datasets for model training (n = 73; 50 and 23 with and without high TPG, respectively) and testing (n = 32; 22 and 10 with and without high TPG, respectively). Three informative shape features were identified in the training datasets: least axis length, sphericity, and maximum three-dimensional diameter. The radiomics score for predicting high TPG in IIH patients demonstrated an AUROC of 0.906 (95% confidence interval, 0.836-0.976) in the training dataset and 0.877 (95% confidence interval, 0.755-0.999) in the test dataset. The nomogram showed good calibration. Conclusion: Our study presents the feasibility of a novel model for predicting high TPG in IIH patients using radiomics analysis of noninvasive MRV-based shape features. This information may aid clinicians in identifying patients who may benefit from stenting.

Responses of Systemic Arterial Blood Pressure and Heart Rates to Graded Increase of Positive Lung Inflation (폐내압증가시(肺內壓增加時)의 동맥혈압(動脈血壓) 및 심박변동(心搏變動)에 관(關)하여)

  • Kim, Kyu-Soo;Oh, Sang-Yu;Choi, Byung-Ok;Lee, Joong-Kil
    • The Korean Journal of Physiology
    • /
    • v.3 no.2
    • /
    • pp.25-31
    • /
    • 1969
  • Effects of graded increase of positive lung inflation upon heart rates and arterial blood pressure were observed in the anesthetized dogs to analyze the mechanical and neural regulatory factor in response to the positive inflation of the lung. The results obtained were summarized as followings: 1) When the low grade of positive lung inflation was employed under the mild to moderate anesthesia, central venous pressure was linearly increased while heart rate was decreased. After bilateral vagotomy, central venous pressure was obviously increased while heart rate was constant. 2) When the high degree of positive lung inflation was employed, changes of central venous pressure and heart rate were not significant. 3) The low grade of intrapulmonary pressure increase caused reflex tachycardia in phase 2 and overshooting in phase 4 in response to the systemic arterial blood pressure change. 4) On the other hand, the high degree of intrapulmonary pressure increase caused paradoxical bradycardia in phase 2 and lack of overshooting in phase 4 in response to the systemic arterial blood pressure change. 5) It may be noted that the experimental model employed in the present study is a useful tool to evaluate and analyze the neural and mechanical regulatory factor in response to the graded increase of the positive lung inflation.

  • PDF

Surgical Correction of Intrahepatic Inferior Vena Cava Obstruction (간내 하공정맥 폐색증의 수술요법)

  • 이정렬
    • Journal of Chest Surgery
    • /
    • v.18 no.1
    • /
    • pp.128-139
    • /
    • 1985
  • Seven patients [six women and one man] with obstruction of hepatic portion of inferior vena cava was operated on, from May, 1969 to January, 1985. Of seven patients, six were undergone corrective operation for IVC obstruction and another one was not operated because of far advanced liver cirrhosis. The occlusions were found at or close to the level of diaphragm and they were membranous or diffuse with or without thrombi. Most of their symptoms were referable to either inferior vena caval or hepatic venous obstruction and onset of the symptoms was usually gradual, beginning between the age of their thirties and forties. Most of the patients showed marked elevation of peripheral venous pressure of lower extremity [29-40 cm H2O] preoperatively, which decreased significantly after corrective operation [17-30 cm H2O]. Venous catheterization for pressure study and venography were essential for confirming the diagnosis. Of six cases, in which corrective operations were done, Transatrial membranotomy with or without IVC dilatation were performed in five cases [case 1, 2, 3, 5, 6], using cardiopulmonary bypass and in another one case, bypass operation between IVC, distal to obstruction, and RA was done using Dacron tube graft under the thoracoabdominal incision. All survived and their conditions were improved.

  • PDF

Direct Open Venous Drainage: An Alternative Choice for Flap Congestion Salvage

  • Park, Su Han;Choi, Woo Young;Son, Kyung Min;Cheon, Ji Seon;Yang, Jeong Yeol
    • Archives of Craniofacial Surgery
    • /
    • v.16 no.3
    • /
    • pp.143-146
    • /
    • 2015
  • In this report, we present a scalp defect reconstruction with lateral arm free flap. We highlight the difficulty in obtaining a recipient vein and the venous drainage managed through an open end of the donor vein. A 52-year-old woman presented with a pressure sore on the left scalp. A lateral arm free flap was transferred to cover this $8{\times}6cm$ defect. The arterial anastomosis was successful, but no recipient vein could be identified within the wound bed. Instead, we used a donor venous end for the direct open venous drainage. In order to keep this exposed venous end patent, we applied heparin-soaked gauze dressing to the wound. Also, the vein end was mechanically dilated and irrigated with heparin solution at two hour intervals. Along with fluid management and blood transfusion, this management was continued for the five days after the operation. The flap survived well without any complication. Through this case, we were able to demonstrate that venous congestion can be avoided by drainage of the venous blood through an open vessel without the use of leeches.