• Title/Summary/Keyword: Velocity Level

Search Result 1,458, Processing Time 0.027 seconds

Analysis of Low Velocity Impact on Biomimetic Composites Mimicking Nacre (진주조개를 모방한 생체모방 복합재료의 저속충격 해석)

  • Jo, Seung-Un;Beom, Hyeon-Gyu
    • Composites Research
    • /
    • v.23 no.4
    • /
    • pp.1-6
    • /
    • 2010
  • The dynamicresponse of biomimetic composites mimicking nacre under low velocity impact is investigated. The composites have hierarchical structures with a staggered pattern consisting of a protein and a mineral. To analyze the impact response of the composites, the finite element method is used. The effects of the hierarchical structures of the compositeson the dynamic response are examined. It is shown that the maximum stress, displacement and contact force in the composite subjected to low velocity impact decrease as the level of structural hierarchy increases.

Measuring Temperature on Wood Surface at the Beginning of Drying Using IR Image Measuring System (적외선 화상처리 장치를 이용한 건조초기 목재 표면 온도 측정)

  • Lee, Kwan-Young;Kang, Ho-Yang;Lee, Min-Kyung
    • Journal of the Korea Furniture Society
    • /
    • v.17 no.3
    • /
    • pp.79-85
    • /
    • 2006
  • Temperature of board surface was monitored during drying using an IR image measurement system. Boards were water-saturated and dried at the levels of four temperatures and three air velocities. At higher DB the surface temperature increased more steeply and level off period was significantly short. At the DB temperatures of 70, 80, $90^{\circ}C$ the period where the surface temperature was equivalent to WB temperature was constant regardless of air velocity while at $60^{\circ}C$ it decreased as air velocity increased. It was confirmed that a surface transfer coefficient increased with DB temperature. Variation of temperature profile on a wood surface increased with DB temperature and air velocity.

  • PDF

Optimization of the head/media interface in HDD considering the load/unload velocity profiles (HDD로드-언로드 속도를 고려한 헤드/미디어 인터페이스 특성 최적화)

  • Kang, Tae-Sik;Kim, Do-Wan;Jeong, Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.902-905
    • /
    • 2003
  • It's general a trend to use the load/unload mechanism in the small form factor HDD, like 2.5", 1.8" and 1.0". The load/unload mechanism has tittle opportunity of head/media contact during the disk spin-up and down. However, the load/unload mechanism needs the precise integration technology with slider, suspension ramp, load/unload velocity and so on, and all of these components should be designed simultaneously, not an individually. In this paper, we measured the load/unload velocity in the drive level, and executed the load/unload dynamics with this velocity profiles. We could find the current load/unload mechanism suitable to the long load/unload test.

  • PDF

An Experimental Study on Laminar Flow Velocity by Using Thermo-sensitive Liquid Crystal (감온액정을 이용한 층류유동의 속도장에 관한 실험적 연구)

  • Chang, Tae-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.7 no.1
    • /
    • pp.19-24
    • /
    • 2004
  • An experimental investigation was performed to study the characteristics of laminar water flow in a horizontal circular tube by using liquid crystal. A simultaneous measurement technique has been employed to measure the velocity field in a two-dimensional cross section of fluid flow. This study found the velocity distributions for Re = 1,594 ~ 2,510 along longitudinal sections and the results appear to be physically reasonable. To determine some characteristics of the laminar flow, 2D PIV technique is employed for velocity measurement by using liquid crystal in water. The experimental rig was manufactured from an acryle tube. The test tube diameter of 25mm, and a length of 1200mm. The used algorithm is the gray level cross-correlation method by using Kimura et al. in 1986.

  • PDF

Two Independent mechanisms for perception of motion in depth

  • Shioiri, Satoshi
    • Journal of the Optical Society of Korea
    • /
    • v.4 no.1
    • /
    • pp.25-29
    • /
    • 2000
  • Two different binocular cues are known for detecting motion in depth. One is disparity change in time and the other is inter-ocular velocity difference. Shioiri, Saisho and Yaguchi (1999) demon-strated that motion in depth can be seen based solely on inter-ocular velocity differences as well as on the disparity change in time. They used conditions in which either cue was minimized and measured performance based on motion in depth, finding better performance than chance level when either velocity cue or the disparity cue was almost isolated. However, there may have been influences from the cue minimized in each condition, since it was practically impossible to isolate perfectly either cue. I re-analyzed their data to examine whether the performance in the condition with disparity change and that in the condition with inter-ocular velocity difference were correlated. The result showed the correlation is very low and therefore, we can conclude that the visual system has two different mechanisms for motion in depth.

Effects of Elastic Taping on the Power and Velocity Error of Rectus Femoris after Muscle Fatigue Occurred (탄력성 테이핑이 근 피로를 적용한 넙다리곧은근의 파워오차와 속도오차에 미치는 영향)

  • Yoon, Junggyu
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.6 no.1
    • /
    • pp.1-6
    • /
    • 2018
  • Purpose : The purpose of this study was to examine the effects of elastic taping on the power and velocity error of rectus femoris after muscle fatigue occurred. Method : The subjects of this study were 15 healthy students. The Primus RS was used to measure the power and velocity error of rectus femoris after muscle fatigue occurred. The power and velocity error were measured 3 times which are consist of pre-fatigue, after-fatigue and after 24 hours applied elastic tape on rectus femoris. A elastic tape was attached to rectus femoris between the antero inferior iliac spine (AIIS) and the tibia tuberosity. The collected data was analyzed using one-way repeated-measures ANOVA for comparison of the power and velocity error according to the measured time and Pearson test for correlation between the power and velocity error according to the measured time. Level of significance was set at 0.05. Result : No significant differences of the power and velocity error were found between $1^{st}$ and 2nd, 3rd measurements (p>.05). The power and velocity error, after 24 hours, of the applied elastic tape with muscle fatigue was significantly lower than muscle fatigue with no taping(p<.05). No significant correlations were found between the power and velocity error according to the measured time(p>.05). Conclusion : After applying the elastic tape on the rectus femoris, muscle fatigue occurred, which improved proprioception by decreasing movement error. It will be an important intervention to prevent musculoskeletal injuries and to enhance the motor control in exercise.

Consideration on the Relation between Vibration Level and Peak Particle Velocity in Regulation of Ground Vibration (지반진동 규제기준에서 진동레벨과 진동속도의 상호관계에 대한 고찰)

  • Choi, Byung-Hee;Ryu, Chang-Ha
    • Explosives and Blasting
    • /
    • v.30 no.2
    • /
    • pp.1-8
    • /
    • 2012
  • The only law related to airblast and ground vibration control in Korea is the Noise and Vibration Control Act enforced by the Ministry of Environment. But this law mainly deals with the annoyance aspects of noises and vibrations in ordinary human life. Hence, the law defines the safety criteria of ground vibration as the vibration level (VL) of dB(V) unit. The ground vibrations produced from blasting, however, have the unique characteristics that can be shown in shock vibrations, and the duration is also very short compared to the vibrations from machinery, tools or facilities. Hence, vibration regulations for blasting operations usually define the safety criterion as the peak particle velocity (PPV) considering the effect of ground vibrations to structural damage. Notwithstanding, there are several attempts that predict VL from PPV or estimate VL based on the scaled distances (SD; in unit of $m/kg^{1/2}$ or $m/kg^{1/3}$) without considering their frequency spectra. It appears that these attempts are conducted mainly for the purpose of satisfying the law in blasting contracts. But, in principle there could no correlation between peaks of velocity and acceleration over entire frequency spectrum. Therefore, such correlations or estimations should be conducted only for the waves with the same or very similar frequency spectra.

Dynamics of Air Temperature, Velocity and Ammonia Emissions in Enclosed and Conventional Pig Housing Systems

  • Song, J.I.;Park, K.H.;Jeon, J.H.;Choi, H.L.;Barroga, A.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.26 no.3
    • /
    • pp.433-442
    • /
    • 2013
  • This study aimed to compare the dynamics of air temperature and velocity under two different ventilation and housing systems during summer and winter in Korea. The $NH_3$ concentration of both housing systems was also investigated in relation to the pig's growth. The ventilation systems used were; negative pressure type for the enclosed pig house (EPH) and natural airflow for the conventional pig house (CPH). Against a highly fluctuating outdoor temperature, the EPH was able to maintain a stable temperature at 24.8 to $29.1^{\circ}C$ during summer and 17.9 to $23.1^{\circ}C$ during winter whilst the CPH had a wider temperature variance during summer at 24.7 to $32.3^{\circ}C$. However, the temperature fluctuation of the CPH during winter was almost the same with that of EPH at 14.5 to $18.2^{\circ}C$. The NH3 levels in the CPH ranged from 9.31 to 16.9 mg/L during summer and 5.1 to 19.7 mg/L during winter whilst that of the EPH pig house was 7.9 to 16.1 mg/L and 3.7 to 9.6 mg/L during summer and winter, respectively. These values were less than the critical ammonia level for pigs with the EPH maintaining a lower level than the CPH in both winter and summer. The air velocity at pig nose level in the EPH during summer was 0.23 m/s, enough to provide comfort because of the unique design of the inlet feature. However, no air movement was observed in almost all the lower portions of the CPH during winter because of the absence of an inlet feature. There was a significant improvement in weight gain and feed intake of pigs reared in the EPH compared to the CPH (p<0.05). These findings proved that despite the difference in the housing systems, a stable indoor temperature was necessary to minimize the impact of an avoidable and highly fluctuating outdoor temperature. The EPH consistently maintained an effective indoor airspeed irrespective of season; however the CPH had defective and stagnant air at pig nose level during winter. Characteristics of airflow direction and pattern were consistent relative to housing system during both summer and winter but not of airspeed. The ideal air velocity measurement favored the EPH and therefore can be appropriate for the Korean environment. Further emphasis on its cost effectiveness will be the subject of future investigations.

The Effect of Replacement Level of Recycled Aggregate on the Properties of High-Performance Concrete (고성능 콘크리트의 특성에 미치는 재생골재 치환율의 영향)

  • Yang Keun-Hyeok;Kim Yong-Seok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.181-184
    • /
    • 2004
  • The objective of this experimental study is to grasp the effect of replacement level of high-quality recycled aggregate on the properties of high-performance concrete. The mixing types were divided into two series based on containing $0\%\;and\;15\%$ fly-ash. Replacement level of recycled aggregate ranged from $0\%\;to\;100\%$. Test results showed that the initial slump and the fluid velocity were independent on the replacement level of recycled aggregate, and the loss of compressive strength was almost $20\%$ with the recycled aggregate only.

  • PDF

Analysis of Hydraulic Characteristics of Yeongsan River and Estuary Using EFDC Model (EFDC-NIER 모델을 이용한 영산강 하구 물흐름 특성 분석)

  • Shin, Chang Min;Kim, Darae;Song, Yongsik
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.6
    • /
    • pp.580-588
    • /
    • 2019
  • The flow of the middle and downstream of the Yeongsan River is stagnant by two weirs of Seungchon and Juksan and the estuary dam and maintained in freshwater. In this study, the Environmental Fluid Dynamics Code-National Institute of Environment Research(EFDC-NIER) model was applied to the Yeongsan River to simulate water flow, temperature, and salinity stratification. The EFDC-NIER model is an improved model which can simulate multi-functional weirs operation, multiple algal species, and the vertical movement mechanism of algal based on the EFDC model. The simulation results for the water level, water temperature, velocity, and salinity reproduced the observed values well. The mean absolute error(MAE) of the model calibration in the annual variations of the water level was 0.1-0.3 m, water temperature was 0.8-1.7 ℃, velocity was 4.5-7.1 cm/sec, and salinity was 1.5 psu, respectively. In the case of scenario simulation for the full opening of the estuary dam, the water level of the estuary dam was directly impacted by the tide so it was predicted to rise - 1.35 m to 0.2 m on average sea level. The velocity was also predicted to increase from 2.7 cm/sec to 50.8 cm/sec, and the flow rate to increase from 53 ㎥/sec to 5,322 ㎥/sec.