• Title/Summary/Keyword: Veiling Reflection

Search Result 6, Processing Time 0.019 seconds

An Ergonomic Study on the Effects of Veiling Reflection in Visibility (시인식에서 반사상의 영향에 관한 인간공학적 연구)

  • Park, Jae-Min;Im, Gi-Yong;Lee, Sang-Do
    • Journal of the Ergonomics Society of Korea
    • /
    • v.19 no.3
    • /
    • pp.13-21
    • /
    • 2000
  • Men perceive and react around him through the five senses. Also men give rise to the human sensibility and maintain his emotion. This study doesn't limit working environment to VDT environment, but considers the universal working environment acquiring information by eyesight stimulation. In case of forming an abnormal veiling reflection we consider the form ; a vertical(25%, 50%, 75%)and a horizontal(25%, 50%, 75%). The results from the subjective evaluation are analyzed by SD(Semantic Differentical methodology)of 5 point scale for visibility and nuisance when an abnormal veiling reflection forms on target. In addition, the results of the objective evaluation are suggested by measuring and analyzing EEG of bio-signal for visual sensitivity. The results of this study can apply to basic data which create a guideline of a visual operation. In particular, it can be designed as an illumination environment concerning an ergonomic factor on visual operations, mental stress such as a visual inspection operation, visual information search operation, etc. As a result, we can expect to reduce the visual nuisance and contribute to the improvement of the performance and the uplift of the competitive power.

  • PDF

An Ergonomic Evaluation of the Effects of Normal Veiling Reflection on the Human Visibility (균일한 반사상이 시인식에 미치는 영향의 인간공학적 평가)

  • 박재민;이상도
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.22 no.50
    • /
    • pp.139-149
    • /
    • 1999
  • The objective of this study was to evaluate the effects of normal veiling reflection on the human visibility during visual tasks. The apparent task luminance and the apparent background luminance contrast were determined by the levels of the normal veiling reflection luminance and the interior illuminance of the visual target. The semantic differential methodology was used for the ergonomic evaluation of the conditions of experiment which were consisted of the apparent task luminance and the apparent background luminance contrast. Twelve subjects (6 male and 6 female) were participated in this study to perform the tasks which were consisted of 40 experimental conditions. And each condition was repeated 4 times.

  • PDF

A evaluating method for the visibility of a visual task covered with veiling reflection (반사상이 중첩한 시대상에 대한 Visibility의 평가법)

  • 김우근
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1993.10a
    • /
    • pp.5-8
    • /
    • 1993
  • The purpose of this study is indused to visibility of visual task when a park of visual task covered with veiling reflection by the transparent materials. As a way, we induce the evaluating systems to the visual task by grasping the rolation between the physical factors and visibility.

  • PDF

Assessment of LCD Color Display Performance Based on AAPM TG 18 Protocol : Decision of Quality Control and Calibration Period (판독용 LCD 컬러 모니터 장치의 성능 평가 - 성능 평가 및 Calibration 주기 결정을 중심으로 -)

  • Lee, Won-Hong;Son, Soon-Yong;Noh, Sung-Soon;Lee, In-Hwa;Kang, Sung-Ho;Lee, Yong-Moon;Park, Jae-Soo;Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.55-60
    • /
    • 2008
  • Purpose: This study is to decide a quality control and calibration period of LCD display devices used for reading diagnostic images. Materias and Methods: The assessment test of 20 flat panel LCD color display devices used for reading diagnostic images were performed based on AAPM TG 18 protocol over the total six sessions at one month intervals from three months after primary calibration, in terms of geometric distortion, reflection test, luminance response evaluation, luminance uniformity, resolution, noise, veiling glare and chromaticity test. Results: The results of geometric distortion, reflection test, luminance uniformity, resolution, noise, veiling glare and chromaticity test were within the criteria recommended by AAPM TG 18, except for luminance response evaluation. In the measured luminance deviation of luminance response evaluation, 4(25%) of 20 display devices were passed a criterion from four months after calibration, and 11 (55%) were passed from eight months. Also in the contrast response of the luminance response evaluation, 1(5%) display device was passed a criterion from four months after calibration, and 3(15%) were passed from eight months. Conclusion: Considering the passing deviation after calibration, the time required and a manpower, the quality control and calibration period of LCD display devices used for reading diagnostic images should be a three months and six months after calibration.

  • PDF

A Study on Quality Assurance(QA) Guideline for Diagnostic Monitor (판독용 모니터 정도관리 항목 및 시행기준안 개발 연구)

  • Son, Gi-Gyeong;Sung, Dong-Wook;Jung, Hae-Jo;Jeong, Jae-Ho;Kang, Hee-Doo;Shin, Jin-Ho;Lee, Sun-Geun;Kim, Yong-Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.1
    • /
    • pp.53-65
    • /
    • 2007
  • PACS has been run at the Kyung Hee University Medical Center(KHMC) since 2001, and the installation and operation of PACS have contributed to automation and quantification of KHMC's medical environment During these five years our greatest concern is how to make our own guiding principle of diagnostic monitor QA which is adapted to international standards. In accordance with the terms of 'KHMC QA Guideline', 'AAPM TG18', 'SMPTE RP133', 'DICOM Part14', 'DIN V 6868-57', 'JESRA X-0093', 'JIS Z4752-2-5' and 'KCARE', concern about quality assurance of medical images are on the increase. With the investigation of acceptance testing and quality control of international standards for medical display devices, and data collection and analysis for recommended guideline, it is reported that acceptance testing(quality control), including geometrical distortion, display reflection, luminance response, luminance uniformity, display resolution, display noise, veiling glare and color chromaticity being adequate and effective to domestic hospital environments for medical display devices and assessment methods according to each performance. Accordingly, KHMC classified the checkpoint items by period, at the time of monitor setting, monthly, quarterly, half-yearly and annually. Periodic classification of checkpoint items for monitor QA makes a good guideline for image QA/QC and useful guideline for persistent good quality of monitor.

  • PDF

The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance (5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구)

  • Jung, Hai-Jo;Kim, Hee-Joung;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • In June 2005, Yonsei University Medical Center, Severance Hospital upgraded a full-PACS system by adding twenty (5 mega pixels) Totoku ME511L flat panel LCD display devices for diagnostic interpretation purposes. Here we report upon the quantitative (or visual) acceptance testing of the twenty Totoku ME511L display devices for reflection, luminance response, luminance spatial dependency, resolution, noise, veiling glare, and display chromaticity based on AAPM TG 18 report. The tools used in the tests included a telescopic photometer, which was used as a colorimeter, illuminance meter, light sources for reflection assessment, light-blocking devices, and digital TG18 test patterns. For selected 8 flat panel displays, mean diffuse reflection coefficient ($R_d$) was $0.019{\pm}0.02sr^{-1}$. In the luminance response test, luminance ratio (LR), maximum luminance difference ($L_{max}$), and deviation of contrast response were $550{\pm}100,\;2.0{\pm}1.9%\;and\;5.8{\pm}1.8%$, respectively. In the luminance uniformity test, maximum luminance deviation was $14.3{\pm}5.5%$ for the 10% luminance of the TG18-UNL10 test pattern. In the resolution test with luminance measurement method, percent luminance (${\Dalta}L$) at the center was $0.94{\pm}0.64%$. In all cases of noise testing, rectangular target In every square in the three quadrants was visible and all 15 targets except the smallest one in the every corner pattern and the center pattern. The glare ratio (GR) was $12,346{\pm}1,995$. The color uniformity, (u',v'), was $0.0025{\pm}0.0008$. Also, the research results of qualify control guideline of primary disply devices suitable for domestic circumstance are presented All test results are in-line with the criteria recommended by AAPM TG18 report and are thus fully acceptable for diagnostic image interpretation. As a result, the acceptance testing schedule described provides not only an acceptance standard but also guidelines for quality control, optimized viewing conditions, and a means for determining the upgrading time of LCD display devices for diagnostic interpretation.

  • PDF