• Title/Summary/Keyword: Various color information

검색결과 811건 처리시간 0.029초

야생화초지 혼파조합을 위한 몇 가지 잔디형 및 야생화 초종의 초기생육과 개화특성에 관한 연구 (Study on the Early Growth and Anthesis Characteristics of Some Turf Type Grasses and Wildflower Species for Mixture Combination of Wildflower Pasture)

  • 이병철;이인덕;이형석
    • 한국초지조사료학회지
    • /
    • 제27권3호
    • /
    • pp.173-182
    • /
    • 2007
  • 본 연구는 야생화 초지조성을 위한 잔디형 목초 및 야생화초종의 선정과 혼파조합구성에 대한 기초자료를 탐색하고자 몇 가지 잔디형 목초와 야생화초종을 공시하여 초기생육, 경엽 및 근중, 건물수량, 개화특성 및 기호성 등을 비교분석하였다. 공시초종은 잔디형 목초 5종{Kentucky bluegrass(Midnight), tall fescue(Millennium), perennial ryegrass(Palmer III), redtop(Barricuda) 및 creeping bentgrass(Crenshaw)}과 야생화 11종{Chrysanthemum leucanthemum L., Coreopsis lanceolata L., Rudbeckia bicolor Nutt., Dianthus chinensis L., Chrysanthemum lindicum L., Lotus corniculatus var. Japonicus Regel, Veronica linariaefolia Pallas, Aster koraiensis Nakai., Chrysanthemum zanadskii var. latilobum(Maxim.) Kitamura, Lythrum anceps Makino 및 Iris nertschinskia. Lodd}을 공시하였으며, 충남대학교 농과대학 초지시험포장에서 2005년 1월부터 2006년 12월까지 수행하였다. 공시된 잔디형 목초 중에서 상대적으로 야생화와 혼파가능성이 큰 초종은 Kentucky bluegrass이었으며, Kentucky bluegrass에 비하여 상대적으로 초기생육이 왕성하고 경엽과 근중이 높아 야생화초지를 조성하는 데 유리할 것으로 보이는 야생화는 Chrysanthemum leucanthemum L., Lotus corniculatus var. Japonicus Regel, Chrysanthemum zawadskii var. latilobum (Maxim) Kitamura 및 Lythrum anceps Makino 등으로 조사되었다. 이들 야생화는 꽃색, 개화시기 및 개화지속기간 등이 서로 중복되지 않았으며 가축에 의한 기호성도 대체적으로 양호한 결과를 보였다. 따라서 야생화초지의 조성을 위해서는 잔디형 목초는 야생화와의 경합력이 낮은 초종을, 반대로 야생화는 경합에서 유리한 초종을 선발하되 개화특성이 서로 다른 야생화를 다양화하여 혼파조합을 구성하는 것이 중요하다고 판단된다.

낭산일대에 분포하는 화강섬록암 암석자원의 열극체계 및 물리적 특성 (Fracture Pattern and Physical Property of the Granodiorite for Stone Resources in the Nangsan Area)

  • 윤현수;홍세선;박덕원
    • 암석학회지
    • /
    • 제16권3호
    • /
    • pp.144-161
    • /
    • 2007
  • 낭산지역 일대의 쥬라기 흑운모 화강섬록암은 담회색, 치밀조직을 이루는 중립질암이다. 암체에 대한 광역적인 열극체계 분석결과는 다음과 같다. 열극의 주향은 빈도등급에 의하여 크게 세 방향으로 분류가 가능하다. 이들 열극은 빈도등급에 의하여 (1) $N80^{\circ}{\sim}90^{\circ}E$ (1st-order)>(2) $N70^{\circ}{\sim}80^{\circ}E$ (2nd-order)>(3) $NS{\sim}N10^{\circ}E$ (3rd-order)의 순으로 나타난다. 특히 이들 열극의 간격은 200 cm 미만의 것들이 대부분을 차지한다. 따라서 분석된 열극체계 및 간격으로 미루어 낭산일대에서는 규격석보다 비규격석의 산출이 훨씬 많아 쇄석자원의 잠재성이 더 클 것으로 해석된다. 특히 밀집하는 기존 석산의 수직상 채석면의 방향도 빈도등급에 의하여 두 그룹으로 분류되어, (1) $N14^{\circ}W{\sim}N16^{\circ}E$ (1st-order)와 (2) $N78^{\circ}E{\sim}N88^{\circ}E$ (2nd-order)에서 뚜렷이 우세하다. 상기한 두 그룹의 수직상 채석면의 방향은 광역적 열극체계와는 다소 차이가 있다. 이와 같은 현상은 단위 석산에서 발달하는 미세균열의 배향성과 크게 관련되는 것으로 볼 수 있다. 낭산지역의 물성 중에서 비중, 흡수율, 공극률, 압축강도, 인장강도와 마모경도는 각각 2.65, 0.28%, 0.73%, $1,628kg/cm^2,\;100kg/cm^2$ 및 31의 평균값을 가진다. 공극률의 경우와는 달리, 낭산 및 속리산지역의 화강암류는 상호 유사한 마모경도를 가진다. 이는 마모저항의 지표로 간주되는 석영과 알칼리장석의 모우드 값의 차이로 설명될 수 있다. 한편 낭산지역의 연구를 통하여 규명된 수직상 채석면의 방향 및 각종 물성특성의 전반적인 이해는 차후 이 지역의 암석자원 활용 시주요 정보로 활용될 것으로 기대된다.

4K-UHD 비디오 시청환경 특성분석을 위한 주관적 화질평가 분석 (Analysis on Subjective Image Quality Assessments for 4K-UHD Video Viewing Environments)

  • 박인경;하광성;김문철;조숙희;최진수
    • 방송공학회논문지
    • /
    • 제15권4호
    • /
    • pp.563-581
    • /
    • 2010
  • 본 논문에서는 초고해상도(UHD: Ultra High Definition) 영상의 방송 서비스를 위한 UHD 영상의 주관적 화질 평가를 수행하고 이에 따른 화질평가 결과를 분석하였다. TV, 인터넷, 개인 미디어 기기들의 보급으로 인해 영상 콘텐츠의 소비가 늘어나고 있으며 이와 더불어 고화질 영상에 대한 수요 또한 증가하고 있다. 현재 HD급($1920{\times}1080$) 영상이 DTV, DVD, 디지털 캠코더, 감시 비디오 및 기타 멀티미디어 기기 등을 통하여 다양한 형태로 소비되고 있으며, 최근에는 이러한 HD 해상도를 넘어 4K-UHD($3840{\times}2160$) 해상도의 디지털 시네마 콘텐츠가 활발히 제작되고 있고, 멀티미디어 시장에서도 이를 지원하는 카메라, 빔 프로젝터, 디스플레이 등의 기기가 출시되기 시작하였으며, 곧 방송${\times}$통신 환경에서도 4K-UHD 비디오 서비스가 출현할 것으로 예상된다. 이에 본 논문에서는 UHD TV 서비스 도입 시에 UHD 비디오의 시청환경 및 신호규격을 결정하는데 도움을 주기 위해 4K-UHD 영상에 대해 공간 해상도, 컬러포맷, 프레임률, 압축률을 포함한 4 가지 항목에 대한 주관적 화질 평가 실험을 수행하였다. 평가 결과, HD 해상도 대비 UHD 해상도의 영상에 대해 더 높은 주관적 화질 평가 결과를 보였으며, 컬러포맷이 YUV444인 4K-UHD 영상이 YUV422, YUV420인 4K-UHD 영상들 보다 화질이 더 높은 주관적 평가를 받았고, YUV422와 YUV420 4K-UHD 영상 간의 화질 비교에서는 주관적 평가 차이는 미미한 것으로 나타났다. 프레임률에 있어서는 60fps의 4K-UHD 영상이 30fps의 4K-UHD 영상보다 움직임이 많은 영상일수록 더 높은 주관적 화질 평가 결과를 보였으며, HD 영상에 대한 비트심도 비교에서는 10bit인 영상과 8bit인 영상 간의 주관적 화질 평가차이는 매우 작은 것으로 나타났다. 마지막으로 복${\times}$부호화된 4K-UHD 영상의 PSNR이 높을수록 높은 주관적 화질평가를 받았으며 시청거리가 멀어질수록 부호화에 의한 화질 열화를 인지하는 능력이 떨어지면서 PSNR이 낮은 영상도 화질이 양호한 것으로 평가되는 경향이 있었다.

오미자(Schizandra chinensis) 추출물이 김치의 과숙억제에 미치는 영향 (Effect of Ethanolic Extract of Schizandra chinensis for the Delayed Ripening Kimchi Preparation)

  • 문영자;박선;성창근
    • 한국식품영양학회지
    • /
    • 제16권1호
    • /
    • pp.7-14
    • /
    • 2003
  • 오미자 에탄올 추출물의 항균활성을 조사하고, 오미자 추출물에 함유된 유기산을 분석하여 오미자 추출물 및 유기산을 첨가하여 제조한 김치의 이화학적 변화와 미생물학적 특성을 살펴본 결과는 다음과 같았다. 1.시중에 유통되는 김치에서 분리한 CS6은 김치의 숙성과 부패에 관여하는 미생물인 Lactobacillus plantarum으로 동정되었으며, 이 균주에 대해 오미자 ethanol 추출물은 항균활성을 보였다. 최소 저해농도는 62.5mg/$m\ell$이었고, 액체배지의 경우 0.5$\mu\textrm{g}$/$m\ell$ 첨가시 미생물의 증식을 완전히 저해하였다. 2. 오미자 ethanol 추출물을 첨가한 김치에서 미생물의 생육을 저해하여 산도는 증가하지 않았다. 0.5% 이하 첨가시에 색상에 영향을 미치지 않으며, 0.4% 첨가시에 맛에 영향을 주지 않았다. 3. 오미자 ethanol 추출물에 succinic acid, malic acid, tartaric acid, oxalic acid등이 포함되어 있었고, 이 중 가장 강한 항균활성을 보인 유기산은 succinic acid였으며, 이의 항균활성은 오미자 ethanol 추출물과 비슷한 저해효과를 보여주었다. 4. Succinic acid를 첨가한 김치의 경우, 미생물의 생육저해로 김치의 신선도 유지에 효과적으로 밝혀졌고, 배양말기까지 일정한 경도를 유지하였고, 역시 0.4% 이하 첨가시 맛에 큰 영향을 주지 않았다. 5. 오미자 ethanol 추출물은 $\beta$-amylase에 대해서는 낮은 저해율을 보였지만 $\alpha$-amylase, glucoamlase에 대해서 강한 저해효과를 나타내어 조직의 연화방지에 효과가 있을 것으로 생각된다. 6. 오미자 ethanol 추출물의 Avicelase 저해효과는 CMCase에 대한 저해효과보다 더 강했으며, 과숙김치에서의 경도 유지효과가 기대된다. 7. 연화와 직접적으로 관련된 효소로 생각되는 polygalacturonase에 대한 저해효과는 오미자 ethanol 추출물 25$\mu\textrm{g}$/$m\ell$ 첨가시에 66.7%의 저해율을 보였고, 30$\mu\textrm{g}$/$m\ell$ 첨가시에는 92.6%의 저해율을 보였으나, pectinesterase의 경우 15~30$\mu\textrm{g}$/$m\ell$ 첨가시에 15~20%의 낮은 저해율을 보였다.

옹기장인의 옹기제작기술과 전통지식 (Techniques and Traditional Knowledge of the Korean Onggi Potter)

  • 김재호
    • 헤리티지:역사와 과학
    • /
    • 제48권2호
    • /
    • pp.142-157
    • /
    • 2015
  • 이 연구는 옹기장인들의 옹기제작기술을 전통지식이라는 관점에서 접근한 것으로 구체적인 옹기제작기술 속에 전통지식들이 어떻게 내재되어 있는지를 살핀 것이다. 특히 옹기제작 관련 전통지식들이 어떤 범주들로 구성되어 있으며 제작기술과의 관계에서 어떤 양상을 띠는가 하는 점들에 주목한다. 옹기제작 과정은 크게 재료의 준비, 기물의 성형, 소성 단계로 나누어지는데, 매 단계마다 고유한 전통지식들이 존재한다. 먼저 재료준비 단계에서는 각종 흙에 대한 지식들이 주를 이룬다. 흙의 색깔과 성질, 좋은 옹기흙의 지역 분포에 대한 정보, 옹기 제작에 적합한 것으로 흙을 재조정하는 기술 등이다. 그리고 두 번째의 기물 성형단계에서는 물레의 구조와 형태, 흙을 쌓아올리는 데 필요한 기술, 각종 도구를 사용하는 방법, 완성된 형태의 옹기를 건조하는 기술 등이 주를 이룬다. 마지막으로 소성 단계에서는 가마에 대한 지식과 가마 제작 기술, 가마 내 옹기를 쟁이는 기술, 화목에 대한 지식과 불 때는 기술, 불의 종류 등이 주를 이룬다. 이들 지식들은 각각 별개로 존재하지 않고 상호 밀접한 관련을 맺고 있다. 이는 어느 한 과정이 잘못되어도 완전한 옹기의 생산이 어려워지기 때문이다. 지식의 내용을 중심으로 볼 때 이들은 재질 색상 형태 분포양상 용융점 강도 물리적 성질 등과 같은 과학적 범주에 속하는 것들이 많다. 하지만 이들 지식들은 공식적 제도교육과정을 통해 얻은 것들이라기보다는 비공식적인 도제교육을 통한 오랜 경험속에서 터득한 것들이 대부분이다. 그리고 지식의 체계는 쉽게 드러나지 않는데, 주로 민속과학(ethnoscience)적 분류와 범주 속에서 이해될 수 있는 것들이 대부분이다. 이들 지식들은 유네스코 세계무형문화유산의 개념으로 보면 '자연 및 우주에 관한 지식'범주에 속한다. 이와는 달리 신체와 사용 도구, 그리고 제작하고자 하는 기물을 일체화시켜 내는 것으로 '신체기술(body techniques)'이라 부를 수 있는 것들도 있다. 이에 대해서는 옹기장인들 스스로도 설명하는 데 어려움을 가지며, 그들이 굳이 설명을 하더라도 해당분야에 대한 경험과 식견이 없는 한 이해가 쉽지 않다. 이러한 지식들은 습득 및 전승방식에 따라 구분해보면,'옹기 장인의 일반적 지식'과 '특정 옹기 장인만이 갖춘 고유한 지식'들로 구분할 수 있다. 그리고 지식이 갖는 축적된 시간의 깊이에 따라 '역사가 긴 지식'과 '최근에 만들어진 지식'등이 있을 수 있다. 옹기제작과정에서 드러난 옹기 장인들의 기술과 전통지식은 재료의 준비과정에서부터 최종 완성품이 만들어지기까지의 전 과정에서 수많은 범주와 층위의 기술들이 긴밀하게 연계되어 있다. 이러한 양상은 '기술의 사슬(techniques chain)'이라고 할 만하다. 이때의 기술은 반드시 자연과학적 범주의 기술(techniques)만을 의미하는 것은 아니며, 솜씨(skill)를 비롯하여 장인들 스스로도 의식하기 어려운 습관적 행위들까지를 포함하는 다양한 층위의 기술과 지식들이라고 할 수 있다.

효과적인 입력변수 패턴 학습을 위한 시계열 그래프 기반 합성곱 신경망 모형: 주식시장 예측에의 응용 (A Time Series Graph based Convolutional Neural Network Model for Effective Input Variable Pattern Learning : Application to the Prediction of Stock Market)

  • 이모세;안현철
    • 지능정보연구
    • /
    • 제24권1호
    • /
    • pp.167-181
    • /
    • 2018
  • 지난 10여 년간 딥러닝(Deep Learning)은 다양한 기계학습 알고리즘 중에서 많은 주목을 받아 왔다. 특히 이미지를 인식하고 분류하는데 효과적인 알고리즘으로 알려져 있는 합성곱 신경망(Convolutional Neural Network, CNN)은 여러 분야의 분류 및 예측 문제에 널리 응용되고 있다. 본 연구에서는 기계학습 연구에서 가장 어려운 예측 문제 중 하나인 주식시장 예측에 합성곱 신경망을 적용하고자 한다. 구체적으로 본 연구에서는 그래프를 입력값으로 사용하여 주식시장의 방향(상승 또는 하락)을 예측하는 이진분류기로써 합성곱 신경망을 적용하였다. 이는 그래프를 보고 주가지수가 오를 것인지 내릴 것인지에 대해 경향을 예측하는 이른바 기술적 분석가를 모방하는 기계학습 알고리즘을 개발하는 과제라 할 수 있다. 본 연구는 크게 다음의 네 단계로 수행된다. 첫 번째 단계에서는 데이터 세트를 5일 단위로 나눈다. 두 번째 단계에서는 5일 단위로 나눈 데이터에 대하여 그래프를 만든다. 세 번째 단계에서는 이전 단계에서 생성된 그래프를 사용하여 학습용과 검증용 데이터 세트를 나누고 합성곱 신경망 분류기를 학습시킨다. 네 번째 단계에서는 검증용 데이터 세트를 사용하여 다른 분류 모형들과 성과를 비교한다. 제안한 모델의 유효성을 검증하기 위해 2009년 1월부터 2017년 2월까지의 약 8년간의 KOSPI200 데이터 2,026건의 실험 데이터를 사용하였다. 실험 데이터 세트는 CCI, 모멘텀, ROC 등 한국 주식시장에서 사용하는 대표적인 기술지표 12개로 구성되었다. 결과적으로 실험 데이터 세트에 합성곱 신경망 알고리즘을 적용하였을 때 로지스틱회귀모형, 단일계층신경망, SVM과 비교하여 제안모형인 CNN이 통계적으로 유의한 수준의 예측 정확도를 나타냈다.

한국(韓國)에서의 벼 잎집무늬마름병 발생변동(發生變動)에 관(關)한 생태학적(生態學的) 연구(硏究) (Ecological Studies on the Transition of Sheath Blight of Rice in Korea)

  • 유승헌
    • 농업과학연구
    • /
    • 제4권2호
    • /
    • pp.283-316
    • /
    • 1977
  • 한국(韓國)에 있어서 벼 잎집무늬마름병(病)의 발생변동(發生變動), 병원균(病原菌)의 배양적(培養的) 특성(特性)과 병원성(病原性), 발병환경(發病環境), 재배법(栽培法)과 발병관계(發病關係), 품종(品種)의 저항성(抵抗性) 등(等)에 관(關)하여 연구(硏究)한 결과(結果)를 요약(要約)하면 다음과 같다. 1. 한국(韓國)에 있어서 벼 잎집무늬마름병(病)의 발생면적(發生面積)은 다비재배(多肥栽培), 조기조식재배(早期早植栽培) 및 통일계품종(統一系品種)의 확대보급등(擴大普及等)으로 인(因)하여 매년(每年) 증가(增加)되었고 특(特)히 1971년(年)부터 전국적(全國的)으로 급격(急激)히 발생면적(發生面積)이 증가(增加)되어서 1976년(年)에는 전체수도재배면적(全體水稻栽培面積)의 약 65.2%에서 본병(本病)이 발생(發生)하였다. 2. 우리나라에 분포(分布)하는 벼 잎집무늬마름병균(病菌)의 배양적(培養的) 성질(性質) 및 병원성(病原性)에는 많은 변이(變異)가 있었으며 병원균(病原菌)의 생육최적(生育最適) 온도(溫度)도 $25^{\circ}C$에서 $30^{\circ}C$사이로 균주간(菌株間)에 차이(差異)가 있었다. 한편 병원균(病原菌)의 배양적(培養的) 성질(性質)과 병원성(病原性)에는 상관관계(相關關係)가 없었다. 3. 잎집무늬마름병균(病菌)의 PDA배지상(培地上)에서의 균사생장(菌絲生長)은 채집지(採集地)의 기온(氣溫)과 밀접(密接)한 관계(關係)가 있었다. 즉 채집지(採集地)의 기온(氣溫)이 높은 지역(地域)의 균주(菌株)들은 기온(氣溫)이 낮은 지역(地域)의 균주(菌株)들에 비(比)해 $35^{\circ}C$ PDA배지(培地)에서 균사생장(菌絲生長)이 양호(良好)하였고 반대로 $12^{\circ}C$ PDA배지상(培地上)에서는 기온(氣溫)이 낮은 지역(地域)에서 채집(採集)한 균주(菌株)들이 기온(氣溫)이 높은 지역(地域)에서 채집(採集)한 균주(菌株)들 보다 균사생장(菌絲生長)이 양호(良好)하였다. 4. 잎집무늬마름병균(病菌)을 접종(接種)한 수도엽(水稻葉)으로부터 얻은 Pectin polygalacturonase 및 Cellulase의 역가(力價)는 접종(接種)3일(日)째에 최대(最大)였고 Pectin methylestrase의 역가(力價)는 접종(接種) 4일(日)째에 최대(最大)였으며 병원성(病原性)이 강(强)한 균주(菌株)에서는 Pectin methylestrase의 활성(活性)이 높은 경향(傾向)이었고 병원성(病原性)이 약한 균주(菌株)에서는 Pectin methylestrase의 활성(活性)이 낮은 경향(傾向)이었으나 다른 효소(酵素)들은 병원성(病原性)과 관계(關係)가 없었다. 5. 배지(培地)에 형성(形成)된 균핵(菌核)을 건조처리(乾燥處理)하였을 경우(境遇)의 저온저항성(低溫抵抗性)은 매우 강(强)하여 $-20^{\circ}C$에서도 발아력(發芽力)을 상실(喪失)치 않았으나 습윤처리(濕潤處理) 하였을 경우(境遇)에는 저항성(抵抗性)이 매우 약(弱)하여 $-5^{\circ}C$에서도 발아력(發芽力)을 상실(喪失)하였다. 포장(圃場)에서 월동(越冬)한 균핵(菌核)의 발아율(發芽率)도 답토양(沓土壤)의 건습(乾濕)에 따라 18%~70%의 차이(差異)를 나타내며 담수상태(湛水狀態)에서 월동(越冬)한 균핵(菌核)은 건조(乾燥)한 토양(土壤)에서 월동(越冬)한 균핵(菌核)보다 발아율(發芽率)이 낮았다. 6. 잡초(雜草)에 대(對)한 기생성(寄生性)을 조사(調査)하였던 바 벗풀(Sagittaria trifolia L.), 물달개비(Monochoria vaginalis Presl), 여뀌(Polygonum hydropiper L.). 피(Echinochloa crusgalli P. Beauv), 한련초(Eclipta prostrata L.), 강아지풀(Septaria viridis P. Beauv.), 좀바랭이(Digitaria sangvinalis Scapoli) 등(等)에서 잎집무늬마름병반(病斑)이 형성(形成)되었다. 7. 질소배비구(窒素倍肥區)에서는 잎집무늬마름병(病)의 피해(被害)가 증가(增加)하였고 가리배비구(加里倍肥區)에서는 감소(減少)하였으나 규산시용구(硅酸施用區)에서는 피해감소(被害減少)의 효과(效果)가 없었다. 규산시용구(硅酸施用區)에서는 도체내(稻體內)의 질소함량(窒素含量)과 전분함량(澱粉含量)이 다같이 감소(減少)하였다. 8. 생육전기(生育前期)의 이병경율(罹病莖率)은 밀식구(密植區)가 높았으나 생육후기(生育後期)에는 소식구(疎植區)의 1주당(株當) 분얼수(分蘖數)가 많아 이병경율(罹病莖率) 및 피해도(被害度)가 높아졌으며 주당(株當) 1본식(本植)한 구(區)에서는 피해(被害)가 적었다. 9. 잎집무늬마름병(病)에 대(對)한 수도(水稻) 품종(品種)의 피해도차이(被害度差異)는 출수일수(出穗日數)와 밀접(密接)한 관계(關係)가 있었다. 즉 출수일수(出穗日數)와 피해도(被害度)와의 상관관계(相關關係)는 6월(月)13일(日) 이앙(移秧)한 구(區)에서는 r=-0.707이었고 6월(月) 25일(日) 이앙(移秧)한 구(區)에서는 r=-0.496으로 비교적 높은 상관(相關)을 나타내어 출수(出穗)가 빠른 것이 피해(被害)가 크고 낮은 것이 피해(被害)가 적은 경향(傾向)이었다. 또한 본병(本病)은 분얼(分蘖)이 많은 품종(品種)일수록 피해(被害)가 심(甚)하였다. 10. 생육전기(生育前期)의 이병경율(罹病莖率)은 출수후(出穗後)의 피해도(被害度)와 상관(相關)이 없었으나 생육후기(生育後期)의 이병경율(罹病莖率)은 피해도(被害度)와 상관(相關)이 높았다.

  • PDF

Emoticon by Emotions: 소비자 감성 기반 이모티콘 추천 시스템 개발 (Emoticon by Emotions: The Development of an Emoticon Recommendation System Based on Consumer Emotions)

  • 김건우;박도형
    • 지능정보연구
    • /
    • 제24권1호
    • /
    • pp.227-252
    • /
    • 2018
  • 인터넷의 발달을 통해 지속적으로 인스턴트 커뮤니케이션이 발달해왔다. 인스턴트 커뮤니케이션에서 가장 대표적인 것이 메신저 애플리케이션이다. 메신저 애플리케이션에서 이모티콘은 송신자의 감정 전달을 보완하기 위해 활용됐다. 메신저 애플리케이션 송신자의 감정 전달에 약한 모습을 보이는데 그 이유는 면대면 커뮤니케이션이 아니기 때문이다. 이모티콘은 과거 화자의 기분 상태를 나타내는 기호로만 사용됐다. 그러나 현재는 이모티콘은 감정 전달 뿐만 아니라 개인의 특성과 개성을 나타내고 싶어 하는 소비자의 심리를 반영하는 형태로 발전해가고 있다. 이모티콘의 사용 환경이 개선되었고, 이모티콘 자체가 발전함으로써 이모티콘 자체에 대한 관심도는 증가하였다. 대표적인 예로 카카오톡, 라인, 애플 등에서 서비스를 진행하고 있으며, 관련 컨텐츠 상품의 매출도 지속적으로 증가할 것으로 전망하고 있다. 이모티콘 자체의 관심도 증가와 관련 사업의 성장세에도 불구하고 현재 적절한 이모티콘 추천 시스템이 부재하다. 국내 점유율 90% 이상의 메신저 애플리케이션인 카카오톡조차 단순히 인기 순이나 최근 순, 혹은 간략한 카테고리 별로 분류한 정도이다. 소비자들은 원하는 이모티콘을 찾기 위해서 스크롤을 계속해서 내려야 하는 불편함이 있으며, 본인이 원하는 감성의 이모티콘을 찾기 어렵다. 소비자들이 편의성 향상과 기업의 이모티콘 관련 사업의 판매 매출 증가를 위해 소비자가 원하는 이모티콘을 추천해줄 수 있는 이모티콘 추천 시스템이 필요하다. 적절한 이모티콘을 추천하기 위해서 소비자가 이모티콘을 보고 느낀 감성에 대해 정량화할 필요성이 있다. 정량화를 통해 소비자가 원하는 이모티콘 셋이 가진 특징과 감성에 대해 분석할 수 있으며, 분석 결과를 토대로 소비자에게 이모티콘을 추천할 수 있다. 이모티콘은 메타데이터화의 방법으로 정량화가 가능하다. 메타데이터화 방법은 빅데이터 시대에 비정형, 반정형 데이터에 대해서 의미를 추출하기 위해 데이터를 구조화 혹은 조직화하는 작업이다. 비정형 데이터인 이모티콘을 메타데이터화를 통해 구조화한다면, 쉽게 소비자가 원하는 감성 형태로 분류할 수 있을 것으로 생각한다. 정확한 감성을 추출하기 위해 감정과 관련된 선행 연구를 통해 7개의 공통 감성 형용사와 한국어에서만 나타나는 은유 혹은 표현적 특징들을 반영하기 위해 하위 세부 표현들까지 고려했다. 이모티콘의 가장 큰 특징인 캐릭터를 기반으로 "표상", "형상", "색상"의 범주에서 세부 하위 감성들을 수집했다. 정확도 높은 추천 시스템을 설계하기 위해 감성 지표만이 아니라 객관적 지표도 고려하였다. 메타데이터화 방법을 통해 이모티콘이 갖고 있는 캐릭터의 특징을 객관적 지표로 14개, 감성 지표로 활용하기 위해 감성 형용사를 36개를 추출하였다. 추출된 감성 형용사는 대비되는 형용사로 구성하여 총 18개로 줄였으며, 18개의 감성 형용사는 카카오톡의 이모티콘을 인기 순으로 임의의 40개 셋을 대상으로 측정하였다. 측정을 위해 이모티콘을 평가할 조사 대상자 온라인으로 모집하였고, 277명의 20~30대의 이모티콘을 구매한 경험이 있는 소비자를 대상으로 설문을 진행하였다. 설문응답자에게 서로 다른 5개의 이모티콘 셋을 평가하도록 하였다. 평가 결과 수집된 18개의 감정 형용사는 요인분석을 통해 감성 지표 요인으로 추출하였다. 추출된 소비자 감성 지표의 요인은 "코믹", "부드러움", "모던함", "투명함"이었다. 이모티콘의 객관적 지표와 감성 지표 요인을 활용하여 소비자 만족과의 관계를 분석하였고, 객관적 지표와 감성 지표 간의 관계도 분석하였다. 이 과정에서 객관적 지표가 소비자 태도에 바로 영향을 주는 것이 아니라 감성 지표 요인을 통해 소비자 태도에 영향을 주는 매개 효과가 있음을 확인하였다. 분석 결과는 소비자의 감성 평가 메커니즘을 밝혀냈고, 소비자의 이모티콘 감성 평가 메커니즘은 객관적 지표가 감성 지표 요인에 영향을 미치며, 감성 지표 요인은 소비자 만족에 영향을 미치는 관계였다. 따라서 감성 지표 요인의 네 가지만으로 이모티콘 추천 시스템을 설계하였고, 추천 방법은 각 감성과의 거리를 유클리디안 거리로 측정하여 거리의 차가 0에 가까울수록 비슷한 감성으로 정의하였다. 본 연구에서 제안한 이모티콘 시스템의 검증을 위해 각 감성 지표 요인과 소비자 만족의 평균을 지표 값으로 활용하여 각 이모티콘 셋의 감성 패턴을 그래프로 비교하였고, 추천된 이모티콘들과 선택된 이모티콘이 대체로 비슷한 패턴을 그리는 것을 확인하였다. 정확한 검증을 위해 사전 조사하였던 소비자를 대상으로 이모티콘 추천 시스템이 제시한 결과와 유사하게 평가하였는지 유사 순위를 세 구간으로 나누어 비교하였고, 순위별 예측 정확도는 결과 1순위 81.02%, 2순위 76.64%, 3순위 81.63%였다. 본 연구의 결과는 학문적, 실무적으로 다양한 분야에서 활용 가능한 방법론을 제시하였으며, 기존에 없던 이모티콘 추천 시스템의 설계를 통해 소비자에게는 편의와 이모티콘을 서비스하는 기업에는 매출증대의 효과를 가져올 것으로 예상한다. 그리고 본 연구를 통해 지능형 이모티콘 시스템으로 발전할 수 있는 단초를 제공했다는 점에서 의미가 있다. 본 연구에서 제안한 감성 요인들을 활용하여 감성 라이브러리로 사용함으로써, 새로운 이모티콘 출시 시 감성 평가의 지표로 활용할 수 있다. 축적된 감성 라이브러리와 기업의 판매 데이터, 매출 정보, 소비자 데이터를 결합하여 본 연구에서 제안한 추천 시스템을 복합형 추천 시스템으로 발전시켜 단순 소비자의 편의성이나 매출 증가뿐만 아니라 기업에서 전략적으로 활용 가능한 지적 자산으로 활용할 수 있을 것으로 판단한다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF