• Title/Summary/Keyword: Various Temperature Condition

Search Result 1,924, Processing Time 0.029 seconds

Neurological aspects of anhidrosis: differential diagnoses and diagnostic tools

  • Park, Kee Hong;Park, Ki-Jong
    • Annals of Clinical Neurophysiology
    • /
    • v.21 no.1
    • /
    • pp.1-6
    • /
    • 2019
  • Anhidrosis refers to the condition in which the body does not respond appropriately to thermal stimuli by sweating. Sweating plays an important role in maintaining the body temperature, and its absence should not be overlooked since an elevated body temperature can cause various symptoms, even leading to death when uncontrolled. The various neurological disorders that can induce anhidrosis make a detailed neurological evaluation essential. The medication history of the patient should also be checked because anhidrosis can be caused by various drugs. The tests available for evaluating sweating include the quantitative sudomotor axon reflex sweat test, thermoregulatory sweat test, sympathetic skin response, and electrochemical skin conductance. Pathological findings can also be checked directly in a skin biopsy. This review discusses the differential diagnosis and evaluation of anhidrosis.

Effects of freezing and thawing on retaining wall with changes in groundwater level

  • Kim, Garam;Kim, Incheol;Yun, Tae Sup;Lee, Junhwan
    • Geomechanics and Engineering
    • /
    • v.24 no.6
    • /
    • pp.531-543
    • /
    • 2021
  • Freezing and thawing of pore water within backfill can affect the stability of retaining wall as the phase change of pore water causes changes in the mechanical characteristics of backfill material. In this study, the effects of freezing and thawing on the mechanical performance of retaining wall with granular backfill were investigated for various temperature and groundwater level (GWL) conditions. The thermal and mechanical finite element analyses were performed by assigning the coefficient of lateral earth pressure according to phase change of soil for at-rest, active and passive stress states. For the at-rest condition, the mobilized lateral stress and overturning moment changed markedly during freezing and thawing. Active-state displacements for the thawed condition were larger than for the unfrozen condition whereas the effect of freezing and thawing was small for the passive condition. GWL affected significantly the lateral force and overturning moment (Mo) acting on the wall during freezing and thawing, indicating that the reduction of safety margin and wall collapse due to freezing and thawing can occur in sudden, unexpected patterns. The beneficial effect of an insulation layer between the retaining wall and the backfill in reducing the heat conduction from the wall face was also investigated and presented.

The Stability of Penicillin G Potassium Injection after Reconstitution in Various Storage Conditions (Penicillin G Potassium 주사액 조제 후 보관방법에 따른 안정성)

  • Chang, Myung Soon;Shin, Hyun Taek;Su, Ok Kyung;Lee, Suk Hyang
    • Korean Journal of Clinical Pharmacy
    • /
    • v.9 no.1
    • /
    • pp.71-76
    • /
    • 1999
  • The stability of penicillin G potassium injection after reconstitution was evaluated in two different diluents of sodium chloride $0.9\%$ and dextrose $5\%$ in water stored at room temperature or refrigerated condition. The concentrations of penicillin G, stored for 24 hours at room temperature or for 10 days at refrigerated condition, were determined by HPLC. Also the pHs of the reconstituted solutions were monitored. The concentrations and pHs of penicillin G potassium 500,000 U/ml injection after reconstitution gradually decreased in all conditions. Stored at room temperature after reconstitution, a new peak which suspected as degradation products of penicillin G was detected in 5 hours in sodium chloride $0.9\%$, 4 hours in dextrose $5\%$ in water. At refrigerated condition, the new peak was detected in 4 days in both sodium chloride $0.9\%$ and dextrose $5\%$ in water. The degradation products of penicillin G allergy have been thought to be one of the substances responsible for evoking allergic reactions. In conclusion, the penicillin G potassium 500,000 U/ml injection after reconstitution was stable for 4 hours in sodium chloride $0.9\%$ 3 hours in dextrose $5\%$ in water solution at room temperature. At refrigerated condition, both solutions were stable for 3 days after reconstitution.

  • PDF

On the Characteristics of the Droplet Formation from an Inkjet Nozzle Driven by a Piezoelectric Actuator (피에조 구동형 잉크젯 노즐에서의 미세 액적 형성 특성)

  • Shin, Pyung-Ho;Sung, Jae-Yong;Lee, Suk-Jong
    • Journal of the Korean Society of Visualization
    • /
    • v.6 no.1
    • /
    • pp.47-52
    • /
    • 2008
  • The present study has focused on the characteristics of droplet formation from an inkjet nozzle driven by a piezoelectric actuator. As an operating fluid, ethylene glycol was used and the physical properties of it such as viscosity, surface tension, contact angle and shear stress were measured. During the experiments, various temperatures and driving voltages are imposed on a capillary tube. These conditions result in a proper drive condition or an overdrive condition. In case of the proper drive condition, an image processing technique is applied to measure the diameter of a single free drop. As a result, the size of droplet is increased when the driving voltage is increased from 160 V to 190 V at 25$^{\circ}C$ In the overdrive condition where temperature or driving voltage becomes higher than the proper drive condition, satellites and the misdirected jets happen.

Biological and Ecological Considerations of the Freshwater Amphipod, Diporeia spp.

  • Song, Ki-Hoon
    • Korean Journal of Environmental Biology
    • /
    • v.21 no.4
    • /
    • pp.328-336
    • /
    • 2003
  • Biological and ecological characteristics of Diporeia spp. are described including size, growth, life cycle, energy storage, temperature effect, bioturbation, feeding depth and sediment ingestion of Diporeia. Bioaccumulation and toxicity of organic contaminants and trace metals were reviewed in addition to an examination of the relationships among various condition indexes (i.e. wet weight, dry weight and body length) of Diporeia.

The Investigation of Microstructure of Electro-deposited Layer for the Corrosion Resistance on Sheet Steel (강판의 부식방지를 위한 도금층 조직관찰)

  • 김인수;이세광
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.10a
    • /
    • pp.224-227
    • /
    • 1997
  • In Ni and Zn plating, microstructure and corrosion behavior of electrodeposits with various electroplating condition were investigated. Optical microstructure, SEM images and polarization curves of electrodeposits are different with plating time and temperature.

  • PDF

Extrusion Puffing of Pork Meat-Defatted Soy Flour-Corn Starch Blends to Produce Snack-like Products

  • Jennifer J. Jamora;Rhee, Ki-Soon;Rhee, Khee-Choon
    • Preventive Nutrition and Food Science
    • /
    • v.6 no.3
    • /
    • pp.163-169
    • /
    • 2001
  • To produce expanded, minimally hard extrudates from blends of raw pork meat (20%), defatted soy flour (25%), and corn starch using a single-screw extruder, various combinations of feed moisture, process temperature, and screw speed were evaluated. First series of extrusion runs were conducted according to a central composite rotatable design/response surface methodology (RSM). Upon assessing the full model for each response, insignificant terms were eliminated to determine final response surface models. Screw speed within the range evaluated was found to have no significant effect on expansion ratio (ER) or shear force (SF) of extrudates. Since examinations of the response surfaces and their generated grids of predicted values indicated that maximum ER and minimum SF were likely to be attained with a moisture-temperature combination outside the RSM experimental range, the second series of extrusion runs were conducted with several selected combinations of moisture and temperature to determine a practical optimum extrusion condition. The combination of 22.78% feed moisture, 16$0^{\circ}C$ process temperature, and 170 rpm screw speed was chosen as such a condition, and used in the final extrusion. The final product required less force to break than did commercial pretzel sticks.

  • PDF

FEM Analysis on Temperature Distribution and Thermal Stress of a Brake Drum for Large Commercial Vehicle (대형 상용차용 브레이크 드럼의 온도 분포 및 열응력에 관한 유한요소 해석)

  • Kim, Ho-Kyung;Lee, Young-In;Joo, Se-Min
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.6 s.78
    • /
    • pp.7-13
    • /
    • 2006
  • A transient heat transfer and thermal stress analysis for a brake drum of commercial vehicles have been performed by ANSYS code in the cases of single braking and the repeated braking condition. The temperature and thermal stress distributions in the brake drum under various braking conditions were obtained using a two-dimensional axisymmetric model. In case of deceleration of 0.3G with an initial vehicle speed of 60km/h, the maximum temperature in the drum was $87.6^{\circ}C$ after braking application. The maximum stress of 78.7MPa in the drum occurred at the intersection between the flange and hat under a condition in which repeated 15 cycles braking with an initial vehicle speed of 60km/h and a deceleration of 0.3G is applied to according to KS R1129. The maximum stress value is much lower than the yield strength of drum material(FC250).

The Effect of Bonding Condition on Tensile Properties of Diffusion Bonds of Graphite Cast Iron FCD60 to Cr-Mo Steel SCM440 (구상흑연주철 FCD60과 Cr-Mo강 SCM440 확산접합부의 인장성질에 미치는 접합조건의 영향)

  • 송우현;김정길;강정윤
    • Journal of Welding and Joining
    • /
    • v.22 no.1
    • /
    • pp.77-82
    • /
    • 2004
  • The effect of bonding condition on tensile properties of joints diffusion bonded spheroidal graphite cast iron, FCD60 to Cr-Mo steel, SCM 440 was investigated. Diffusion bonding was performed with various temperatures, holding times, pressures and atmospheres. All tensile specimens were fractured at the bonding interface. The tensile strength and elongation was increased with increasing bonding temperature. Especially, tensile strength of joints bonded at 1123K was higher than that of a raw material, FCD60, and tensile strength of joints bonded at 1173K was equal to that of a raw material, SCM440, but elongation of all joints was lower than those of raw materials. There was little the effect of holding time on the tensile properties. In comparison with bonding atmosphere, the difference of tensile strength was not observed, but elongation of joint bonded at vacuum(6.7mPa and 67mPa) was higher than that of Ar gas. Higher the degee of vacuum, elongation increased. Tensile properties of diffusion bonds depended on microstructures of cast iron at the interface and void ratio. Microstructures of cast iron at interface changed with temperature, because decarburizing and interdiffusion at the interface occurs and transformation of austenite-1 ferrite + graphite occurs on the cooling process. The void ratio decreased with increasing temperature, especially, effected on the elongation.

Evaluation of Nitritation of High Strength Ammonia with Variation of SRT and Temperature using Piggery Wastewater (SRT와 온도 변화를 통한 돈사폐수 내 고농도 암모니아의 아질산화 평가)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.5
    • /
    • pp.563-571
    • /
    • 2011
  • The purpose of this study is to investigate the high strength ammonia oxidation of piggery wastewater. Laboratory scale reactors was operated using influent of piggery wastewater and effluent of anaerobic digester from piggery wastewater at $35^{\circ}C$ and $20^{\circ}C$. Results of various operating conditions were compared and analyzed. After analyzing the results, effluent of anaerobic digester from piggery wastewater required shorter Solid retention time (SRT) than influent of piggery wastewater. In terms of the temperature, stable ammonia removal and denitrification was achieved on the both of the condition. At the temperature of $35^{\circ}C$, nitrite conversion rate was better than $20^{\circ}C$. It can be concluded that treating the piggery wastewater using anaerobic digester on the condition of the temperature at $35^{\circ}C$ is more efficient on the nitritation of the piggery wastewater.