• Title/Summary/Keyword: Varied Section

Search Result 284, Processing Time 0.022 seconds

Construction of Speed Predictive Models on Freeway Ramp Junctions with 70mph Speed Limit. (70mph 제한속도를 갖는 고속도로 연결로 접속부상에서의 속도추정모형에 관한 연구)

  • 김승길;김태곤
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1999.10a
    • /
    • pp.111-121
    • /
    • 1999
  • From the traffic analyses, and model constructions and verifications for speed prediction on the freeway ramp junctions with 70mph speed limit, the following results obtained: ⅰ) The traffic flow distribution showed a big difference depending on the time periods. Especially, more traffic flows were concentrated on the freeway junctions in the morning peak period when compared with the afternoon peak period. ⅱ) The occupancy distribution was also shown to be varied by a big difference depending on the time periods. Especially, the occupancy in the morning peak period showed over 100% increase when compared with the 24hours average occupancy, and the occupancy in the afternoon peak period over 25% increase when compared with the same occupancy.ⅲ) The speed distribution was not shown to have a big difference depending on the time periods. Especially, the speed in the morning peak period shown 10mph decrease when compared with the 24hours' average speed, but the speed did not show a big difference in the afternoon peak period.ⅳ) The analyses of variance showed a high explanatory power between the speed predictive models(SPM) constructed and the variables used, especially the upstream speed. ⅴ) The analysis of correlation for verifying the speed predictive models(SPM) constructed on the ramp junctions were shown to have a high correlation between observed data and predicted data. Especially, the correlation coefficients showed over 0.95 excluding the unstable condition on the diverge sectionⅵ) Speed predictive models constructed were shown to have the better results than the HCM models, even if the speed limits on the freeway were different between the HCM models and speed predictive models constructed.

Long-term assessment of periodontal disease progression after surgical or non-surgical treatment: a systematic review

  • Sanz-Martin, Ignacio;Cha, Jae-Kook;Yoon, Sung-Wook;Sanz-Sanchez, Ignacio;Jung, Ui-Won
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.2
    • /
    • pp.60-75
    • /
    • 2019
  • The primary aim of this systematic review was to assess the evidence on periodontal disease progression after treatment in patients receiving supportive periodontal therapy (SPT) and to identify predictors of clinical attachment level (CAL) loss. A protocol was developed to answer the following focused question: In adult patients treated for periodontitis, what is the disease progression in terms of CAL loss after surgical or non-surgical treatment? Randomized controlled clinical trials, prospective cohort studies, and longitudinal observational human studies with a minimum of 5 years of follow-up after surgical or non-surgical treatment that reported CAL and probing depth changes were selected. Seventeen publications reporting data from 14 investigations were included. Data from 964 patients with a follow-up range of 5-15 years was evaluated. When the CAL at the latest follow-up was compared to the CAL after active periodontal therapy, 10 of the included studies reported an overall mean CAL loss of ${\leq}0.5mm$, 3 studies reported a mean CAL loss of 0.5-1 mm, and 4 studies reported a mean CAL loss of >1 mm. Based on 7 publications, the percentage of sites showing a CAL loss of ${\geq}2mm$ varied from 3% to 20%, and a high percentage of sites with CAL loss was associated with poor oral hygiene, smoking, and poor compliance with SPT. The outcomes after periodontal therapy remained stable over time. Disease progression occurred in a reduced number of sites and patients, mostly associated with poor oral hygiene, poor compliance with SPT, and smoking.

Designing of Safe Duct for Leisure Boat with Wing Section (익형 형상을 적용한 레저 선박용 안전 덕트 개발)

  • Sang-Jun Park;Jin-Wook Kim;Moon-Chan Kim;Woo-Seok Jin;Sa-Kyo Jung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.6
    • /
    • pp.424-432
    • /
    • 2023
  • This study deals with the design of a safety device around a leisure boat propeller. The safety device is to be designed to minimize performance degradation attached to propulsors in coastal waters. These devices, important for preventing propeller accidents, negatively gives influence boat performance, especially at higher speeds. In order to minimize the negative effect, the accelerating ducts, normally used in ESDs (Energy Saving Devices) have been chosen as a safety device. The present study aims to design an optimal duct (minimizing negative effect) through the parametric study. Based on the Marine 19A nozzle, the nozzle's thickness and angle were varied to obtain the optimum parameter in the preliminary design by the computational fluid dynamics program Star-CCM+ Ver. 15.02. In the detailed design, a NACA 4-digit Airfoil shape resembling the Marine 19A by modification at the trailing edge was chosen and the optimum shape was chosen according to variation of camber, thickness, and incidence angle for optimization. The optimally designed duct shows a speed decrease of about 10% in the sea trial result, which is much smaller than the normal speed decrease of at least 30%. The present designing method can give wide applications to the leisure boat because the wake is almost the same due to using the outboard propulsor.

Buckling Sensitivity of Laminated Composite Pipes Under External Uniform Pressure Considering Ply Angle (등분포하중을 받는 복합재료 관로의 적층각 변화에 따른 좌굴 민감도 분석)

  • Han, Taek Hee;Na, Tae Soo;Han, Sang Yun;Kang, Young Jong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.3
    • /
    • pp.123-131
    • /
    • 2007
  • The buckling behavior of a fiber reinforced plastic pipe was researched. When a cylindrical structure is made of isotropic material, it shows two dimensional buckled shape which has same deformed section along the longitudinal direction. But an anisotropic cylindrical structure shows three dimensional buckled shape which has different deformed section along the longitudinal direction. Because the modulus of elasticity is varied in a certain direction when ply angles are changed, the strength of a pipe are changed as ply angles are changed. In this study, the limitation of two dimensional and three dimensional buckling mode was investigated and the buckling strength of a laminated composite pipe was evaluated.

Investigation on Combustion Characteristics of Pressurized Oxy-fuel Combustion System using Low Calorific Value Syngas (저열량 합성가스를 이용한 가압 순산소 연소 시스템의 연소 특성 분석 연구)

  • Kim, Dong-hee;Lee, Young-jae;Yang, Won
    • Journal of the Korean Society of Combustion
    • /
    • v.21 no.4
    • /
    • pp.39-47
    • /
    • 2016
  • The aims of this research were to investigate combustion characteristics of lab-scale pressurized oxy-fuel combustion(POFC) system. In this study, the reactor, 800 mm long, was equipped with co-axial burner. Low calorific value syngas that is composed of mainly CO and $H_2$ was used as fuel whereas pure oxygen was used as an oxidant. Thermal heat input to the reactor varied from 2.6 kW to 6.1 kW. The reactor pressure also increases from atmospheric up to 15 bar. The results show that as the pressure increase, the temperature of reactor decreases on the whole in all cases. A significant temperature drop was observed especially at the bottom section of the reactor that exist flame. In addition, the flame instability increases as the pressure increases. Furthermore $NO_x$ emissions increases from atmospheric up to 2 bar. However beyond 2 bar, $NO_x$ emission reduces as pressure increases. Lastly $NO_2$ ratio in $NO_x$ also increases as pressure increases.

Heat Transfer Correlation during Gas-Cooling Process of Carbon Dioxide in a Horizontal Tube

  • Kang Byung-Ha;Choi Yi-Cheol;Kim Suk-Hyun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.1
    • /
    • pp.19-27
    • /
    • 2006
  • The characteristics of heat transfer and pressure drop have been investigated experimentally during gas-cooling process of carbon dioxide. The results of this study are useful information in the design of a heat exchanger of $CO_2$ refrigerator. The test section consists of 6 series of copper tube, 4.15 and 2.18mm ID, respectively. The inlet temperature, the operating pressure, and the mass flux are varied in the range of $80{\sim}120^{\circ}C,\;{7\sim}10MPa,\;and\;400{\sim}1,900kg/m^2s$, respectively. The heat transfer coefficient of $CO_2$ is affected by temperature, inlet pressure, and mass flux of $CO_2$. At the maximum HTC, the temperature of $CO_2$ nearly accords with the psuedocritical temperature. It is found that the pressure drop is substantially affected by mass flux and inlet pressure of $CO_2$ . The results have been compared with those of previous work. The heat transfer correlation at the gas-cooling process has been also suggested which predicts within the error of 20%.

The Study on the Drag Reduction for Gas/Liquid Two Phase Flow (기-액(氣-液) 2상유동(二相流動)시 항력(抗力)에 관(關)한 연구(硏究))

  • Cha, K.O.;Oh, Y.K.;Kim, J.G.
    • Journal of ILASS-Korea
    • /
    • v.1 no.3
    • /
    • pp.20-28
    • /
    • 1996
  • It is well known that drag reduction in single phase liquid flow is affected by polymer material, molecular weight, polymer concentration, pipe diameter, and flow velocity. Drag reduction in two phase flow can be applied to the transport of crude oil, phase change system such as chemical reactor, pool and boiling flow, and to present cavitation which occurs in pump impellers. But the research of drag reduction in two phase flow is not sufficient. The purpose of the present work is to evaluate the drag reduction by measuring pressure drop, void fraction whether polymer is added in the horizontal two phase system or not. Experiment has been conducted in a test section with 24 m of the inner diameter and 1,500 mm of the length. The used polymer materials are two kinds of polyacrylamide[PAAM] and co-polymer[A611P]. The polymer concentration was varied with 50, 100 and 200 ppm under the same experimental conditions. Experimental results were shown that the drag is higher reduced by co-polymer rather than polyanylamide.

  • PDF

An Experimental Study on Heat Transfer and Pressure Drop Characteristics during Supercritical Process of Carbon Dioxide in a Horizontal Tube (수평관 내에서 이산화탄소 초임계 가스냉각 과정의 열전달 및 압력강하 특성에 관한 실험적 연구)

  • 최이철;강병하;김석현
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.414-420
    • /
    • 2004
  • The heat transfer and pressure drop characteristics associated with the gas cooling of the supercritical carbon dioxide in a horizontal tube have been investigated experimentally. This problem is of particular interest in the design of a gas cooler of cooling systems using $CO_2$refrigerant. The test section is consisted of 6 series of 455 mm in length, 4.15 mm ID copper tube, respectively. The effects of the inlet temperature, pressure and mass flow rate on the heat transfer and pressure drop of $CO_2$in a horizontal tube is studied in detail. The heat transfer coefficient of $CO_2$is varied by temperature, inlet pressure, and mass flow rate of $CO_2$. This has maximum value at near the pseudocritical temperature. The pressure drop is changed by inlet pressure and mass flow rate of $CO_2$. The results have been compared with those of previous work. The heat transfer correlation at the supercritical gas cooling process is also suggested.

Penetrating behavior of target prawns (Sicyonia penicillata) contacting netting panels in an experimental water tunnel

  • KIM, Yonghae;GORDON, Malcolm S.
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.54 no.3
    • /
    • pp.193-203
    • /
    • 2018
  • Capture efficiencies of commercial shrimp trawls may improve if their designs took into better account behavioral responses of wild shrimp to approaching cod-end of the trawls. Here we report results of water tunnel-based experimental studies of responses of wild California target prawns to several different near-realistic netting configurations over a range of water velocities (0.3-0.7 m/s). Netting panels were oriented at parallel to water flows (FP) on the bottom of test section, vertical (VT) or diagonal sloping backward (DG), bottom to top. Behavioral responses were recorded by video camera and analyzed frame by frame. Measured responses included rates of penetrating through netting by behavioral features and tail-flip frequencies. Frequencies of prawn passing through the nets increased with flow speed for both orientations and were higher at given speeds for sloped nets. Other behavioral features (e.g., passage head-or tail-first) also varied significantly with water velocities and netting orientation. Interactions of penetrating rates between netting orientations and flow speeds also were significantly dependent, except for prawn size. Additional studies are needed of other shrimp species and at higher water velocities more similar to actual field operations using trawls to improve size selectivity.

Condensing Heat Transfer of Natural Refrigerants with Nanoparticles in Enhanced Tube (나노입자를 포함한 자연냉매의 마이크로 휜관 응축 열전달 특성)

  • Lee, H.S.
    • Journal of Power System Engineering
    • /
    • v.12 no.3
    • /
    • pp.19-25
    • /
    • 2008
  • This paper deals with the heat transfer and pressure drop characteristics of R-290 (Propane), R-600a (Iso-butane) and R-1270 (Propylene) as an environment friendly refrigerant and R-22 as a HCFC's refrigerant for condensing. The test section is a horizontal double pipe heat exchanger. Condensing heat transfer and pressure drop measurements were Peformed for 12.70 mm micro-fin tube and compared with the results in smooth tube. The local condensing heat transfer coefficients of hydrocarbon refrigerants were superior to those of R-22 and the maximum increasing rate of heat transfer coefficient was found in R-600a. The average condensing heat transfer coefficients in hydrocarbon refrigerants showed 20 to 28% higher values than those of R-22. Hydrocarbon refrigerants have a higher pressure drop than that of R-22 with respect to refrigerant qualify and mass flux. Also, the condensing heat transfer coefficient and pressure drop of working fluids in smooth and micro-fin tube were compared. The heat transfer enhancement factor (EF) between smooth and micro-fin tube varied from 2.2 to 2.6 in all experimental conditions.

  • PDF