• Title/Summary/Keyword: Variation operator

Search Result 113, Processing Time 0.026 seconds

A MULTI-DIMENSIONAL MAGNETOHYDRODYNAMIC CODE IN CYLINDRICAL GEOMETRY

  • Ryu, Dong-Su;Yun, Hong-Sik;Choe, Seung-Urn
    • Journal of The Korean Astronomical Society
    • /
    • v.28 no.2
    • /
    • pp.223-243
    • /
    • 1995
  • We describe the implementation of a multi-dimensional numerical code to solve the equations for idea! magnetohydrodynamics (MHD) in cylindrical geometry. It is based on an explicit finite difference scheme on an Eulerian grid, called the Total Variation Diminishing (TVD) scheme, which is a second-order-accurate extension of the Roe-type upwind scheme. Multiple spatial dimensions are treated through a Strang-type operator splitting. Curvature and source terms are included in a way to insure the formal accuracy of the code to be second order. The constraint of a divergence-free magnetic field is enforced exactly by adding a correction, which involves solving a Poisson equation. The Fourier Analysis and Cyclic Reduction (FACR) method is employed to solve it. Results from a set of tests show that the code handles flows in cylindrical geometry successfully and resolves strong shocks within two to four computational cells. The advantages and limitations of the code are discussed.

  • PDF

A 9-Rule Fuzzy Logic Controller of the Nuclear Steam Generator (핵증기 발생기의 9룰 퍼지논리 제어기)

  • Lee, Jae-Young;No, Hee-Cheon
    • Nuclear Engineering and Technology
    • /
    • v.25 no.3
    • /
    • pp.371-380
    • /
    • 1993
  • A model free controller utilizing a set of linguistic fuzzy logic of the human operator's experience is developed to control the steam generator water level in a pressurized water reactor. Only 9 rules for control action are generated from the inputs of water level error and mass flow error implicitly representing the time variation of the collapsed water level. The bell type membership functions of the premise side and the result side are tuned by the sensitivity study. This compact fuzzy logic controller shows a robust control during transient and no offset error and oscillation during steady state operation. For a multi-ramp power increase from start-up to full power, the proposed controller shows good performance for the entire range.

  • PDF

ON WIELANDT-MIRSKY'S CONJECTURE FOR MATRIX POLYNOMIALS

  • Le, Cong-Trinh
    • Bulletin of the Korean Mathematical Society
    • /
    • v.56 no.5
    • /
    • pp.1273-1283
    • /
    • 2019
  • In matrix analysis, the Wielandt-Mirsky conjecture states that $$dist({\sigma}(A),{\sigma}(B)){\leq}{\parallel}A-B{\parallel}$$ for any normal matrices $A,B{\in}{\mathbb{C}}^{n{\times}n}$ and any operator norm ${\parallel}{\cdot}{\parallel}$ on $C^{n{\times}n}$. Here dist(${\sigma}(A),{\sigma}(B)$) denotes the optimal matching distance between the spectra of the matrices A and B. It was proved by A. J. Holbrook (1992) that this conjecture is false in general. However it is true for the Frobenius distance and the Frobenius norm (the Hoffman-Wielandt inequality). The main aim of this paper is to study the Hoffman-Wielandt inequality and some weaker versions of the Wielandt-Mirsky conjecture for matrix polynomials.

Exposure and Risk Assessment of Operators to Insecticide Acetamiprid during Treatment on Apple Orchard

  • Kim, Eunhye;Moon, Joon-Kwan;Lee, Hyeri;Kim, Suhee;Hwang, Yon-Jin;Kim, Byung-Joon;Lee, Jinbeum;Lee, Dong-Hyuk;Kim, Jeong-Han
    • Horticultural Science & Technology
    • /
    • v.31 no.2
    • /
    • pp.239-245
    • /
    • 2013
  • Occupational exposure and risk assessment were conducted to evaluate the safety of operators when insecticide acetamiprid was applied to apple orchard using a speed sprayer. Dermal patches, cotton gloves, socks, and masks were used to monitor the dermal exposure, and personal air pump with solid sorbent was used to measure the potential inhalation exposure. In validation to analytical methods, the limit of detection and limit of quantitation were 0.25 ng and 1 ng, respectively. Good reproducibility (coefficient variation < 4%), linearity (coefficient determination > 0.999), and recovery (85.3-118.2%) were obtained. Trapping efficiency of solid sorbent was 96.4% while breakthrough did not occur. Only hand exposure was measured on the gloves during mixing/loading to give $33-1,132{\mu}g$. Exposure amount of operator 3 among 4 workers was noticeably high. The total volumes of spray liquid for operators were $535-1,235mL{\cdot}h^{-1}$, corresponding to 0.03-0.08% of the applied spray solution. Highest contaminated parts of body were thighs, chest, and lower legs. The inhalation exposure ratio to the total application amount was significantly low. However, wind seemed to affect the inhalation exposure of operator. For risk assessment, margin of safety was calculated by the application of cloth and dermal penetration rate to obtain values of much larger than 1 in all cases. Therefore, health risk of operators during treatment of acetamiprid in apple orchard could be of least possibility.

Component-Z: A Formal Specification Language Extended Object-Z for Designing Components (Component-Z: Object-Z를 확장한 컴포넌트 정형 명세 언어)

  • 이종국;신숙경;김수동
    • Journal of KIISE:Software and Applications
    • /
    • v.31 no.5
    • /
    • pp.677-696
    • /
    • 2004
  • Component-based software engineering (CBSE) composes reusable components and develops applications with the components. CBSE is admitted to be a new paradigm that reduces the costs and times to develop software systems. The high quality of component designs can be assured if the consistency and correctness among the elements of a component are verified with formal specifications. Current formal languages for components include only some parts of contracts between interfaces, structural aspects and behavioral aspects of component, component-based system, component composition and variability. Therefore, it is not adequate to use current formal languages in all steps of a component design process. In this paper, we suggest a formal language to specify component designs Component-Z. Component-Z extends Object-Z, adds new notations to specify components. It can be possible to specify interfaces, the inner structure of a component, inner workflows, and workflows among interfaces with Component-Z. In addition, Component-Z provides the notations and semantics to specify variability with variation points, variants and required interfaces. The relation between interfaces and components is defined with mapping schemas. Parallel operator is used to specify component composition. It can be possible to describe deployed components with the specifications of component-based systems. Therefore, the formal specification language proposed in this paper can represent all elements to design components. In the case study, we specify an account management system in a bank so that we show that Component-Z can be used in all steps of component design.

Development of Automated Region of Interest for the Evaluation of Renal Scintigraphy : Study on the Inter-operator Variability (신장 핵의학 영상의 정량적 분석을 위한 관심영역 자동설정 기능 개발 및 사용자별 분석결과의 변화도 감소효과 분석)

  • 이형구;송주영;서태석;최보영;신경섭
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.41-50
    • /
    • 2001
  • The quantification analysis of renal scintigraphy is strongly affected by the location, shape and size of region of interest(ROI). When ROIs are drawn manually, these ROIs are not reproducible due to the operators' subjective point of view, and may lead to inconsistent results even if the same data were analyzed. In this study, the effect of the ROI variation on the analysis of renal scintigraphy when the ROIs are drawn manually was investigated, and in order to obtain more consistent results, methods for automated ROI definition were developed and the results from the application of the developed methods were analyzed. Relative renal function, glomerular filtration rate and mean transit time were selected as clinical parameters for the analysis of the effect of ROI and the analysis tools were designed with the programming language of IDL5.2. To obtain renal scintigraphy, $^{99m}$Tc-DTPA was injected to the 11 adults of normal condition and to study the inter-operator variability, 9 researchers executed the analyses. The calculation of threshold using the gradient value of pixels and border tracing technique were used to define renal ROI and then the background ROI and aorta ROI were defined automatically considering anatomical information and pixel value. The automatic methods to define renal ROI were classified to 4 groups according to the exclusion of operator's subjectiveness. These automatic methods reduced the inter-operator variability remarkably in comparison with manual method and proved the effective tool to obtain reasonable and consistent results in analyzing the renal scintigraphy quantitatively.

  • PDF

Colormap Construction and Combination Method between Colormaps (컬러맵의 생성과 컬러맵간의 결합 방법)

  • Kim, Jin-Hong;Jo, Cheol-Hyo;Kim, Du-Yeong
    • The Transactions of the Korea Information Processing Society
    • /
    • v.1 no.4
    • /
    • pp.541-550
    • /
    • 1994
  • A true color image is needed many data on the occasion of the transmission and storage. Therefore, we want to describe color image by a minority data without unreasonableness at eyesight. In this paper, it is presented 256 colormap construction method in RGB, YIQ/YUV space and common colormap expression method at merge between colormaps by reason of dissimilar original color image to display at a monitor for each other colormap at the same time. In comparison with processed result in RGB, YIQ/YUV space, it was measured by PSNR, standard variation, and edge preservation rate using sobel operator. Process time is 3second in colormap construction and 2second in merge between colormaps. In the PSNR value, RGB space has higher 0.15, 0.34 on an average than YIQ and YUV spae. Standard variation has lower in 0.15, 0.41 on an average than Yiq and YUV space. But in the data compression, YIQ/YUV space have about 1/3 compression efficiency than RGB space by reason of use to only 4bit of 8bit in color component.

  • PDF

Factor Analysis of Decreased Score on Coronary Artery Calcium Score (관상동맥 석회화점수 감소 요인 분석)

  • Shim, Jae-Goo;Kim, Yon-Min;Kim, Jin-Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.285-290
    • /
    • 2016
  • The purpose of our study was to retrospectively evaluate the cause of a decreased calcium score of follow-up studies on coronary artery calcium scores (CACs) computed tomography (CT). The subjects were healthy 100 people(85 males $60.6{\pm}6.9$ years, 15 females $67.2{\pm}7.3$ years). The subjects decreased CACs were divided into 4 subgroups depending on Agatston classification, minimal (1-10), mild (11-100), moderate (101-400), severe (400<). As a result of decreased CACs were scan location disagreement 51%, motion artifact 26%, equipment changes 14%, operator mistakes 5%, input miss 2%, image loss 1%, arrhythmia 1%. In the mild group, the most common decreased CACs were 49 people. In the minimal group, the most significant variation reduction has occurred to 6 people. Scan location disagreement was considered a partial volume effects due to the scan starting position. It showed less than 100 CACs a high variation (19.7%) in more than 100 CACs, a lower variation (2.2%), these could be seen that the variation range is different that can be tolerated according to the calcification score. Motion artifact factor was found in 26%, which is so closely related to the preceding tests that affect the higher heart rate like this pulmonary function test, exercise stress test.

Hydroelastic analysis of a truss pontoon Mobile Offshore Base

  • Somansundar, S.;Selvam, R. Panneer;Karmakar, D.
    • Ocean Systems Engineering
    • /
    • v.9 no.4
    • /
    • pp.423-448
    • /
    • 2019
  • Very Large Floating Structures (VLFS) are one among the solution to pursue an environmentally friendly and sustainable technology in birthing land from the sea. VLFS are extra-large in size and mostly extra-long in span. VLFS may be classified into two broad categories, namely the pontoon type and semi-submersible type. The pontoon-type VLFS is a flat box structure floating on the sea surface and suitable in regions with lower sea state. The semi-submersible VLFS has a deck raised above the sea level and supported by columns which are connected to submerged pontoons and are subjected to less wave forces. These structures are very flexible compared to other kinds of offshore structures, and its elastic deformations are more important than their rigid body motions. This paper presents hydroelastic analysis carried out on an innovative VLFS called truss pontoon Mobile Offshore Base (MOB) platform concept proposed by Srinivasan and Sundaravadivelu (2013). The truss pontoon MOB is modelled and hydroelastic analysis is carried out using HYDRAN-XR* for regular 0° waves heading angle. Results are presented for variation of added mass and damping coefficients, diffraction and wave excitation forces, RAOs for translational, rotation and deformational modes and vertical displacement at salient sections with respect to wave periods.

Fast 2-D Moving Target Tracking Algorithm (Fast 2차원 동 표적 추적 알고리즘)

  • Kim, Gyeong-Su;Lee, Sang-Uk;Song, Yu-Seop
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.1
    • /
    • pp.75-85
    • /
    • 1985
  • We have studied on the 2-D moving target tracking algorithm satisfying a real-time hardware implementation requirement. In this paper, a fast algorithm is developed based on the operator formulation and the variational algorithm f 10] . Here, we use the directed search for the maximum of the cross-correlation in order to obtain an initial estimate for the variational algorithm and decompose the scene into 16 smaller subblocks and apply the variational algorithm to each subblock sequentially with a new moving area detection method. We call the algorithm subblock based recursive algorithm. Compared with (10) , the ratio of the computational savings obtained from the proposed algorithm is 7 on the average.

  • PDF