• 제목/요약/키워드: Variation Source

검색결과 1,345건 처리시간 0.035초

근거리 무선 전력 전송을 위한 평형 증폭기 구조의 10MHz 10W급 전력원 설계 (Design of the 10MHz and 10W Power Source for Short Distance Wireless Power Transmission)

  • 박동훈;김귀성;임은천;박혜미;이문규
    • 전기학회논문지
    • /
    • 제61권3호
    • /
    • pp.437-441
    • /
    • 2012
  • In this paper, we have designed and manufactured 10MHz power source for the application of short distance wireless power transmission. The designed power source consists of a DDS(direct digital synthesizer) signal generator, a buffer driver and a balanced power amplifier. Short range wireless power transmission is usually carried out by near-field inductive coupling between source and load. The distance variation between source and load gives rise to the change of load impedance of power amplifier, which has effect on the operation of power amplifier. To overcome this problem due to load variation of power amplifier, we have adopted the balanced power amplifier using the quadrature hybrid implemented by lumped capacitors and a mutually coupled coil. The experiment results show the above 40dBm output power, frequency range of 9 to 11MHz, and total DC power consumption of 36W.

탄소발열체의 외부유속 및 직경변화에 대한 비정상상태에서의 수치해석적 연구 (Numerical Analysis in Unsteady State on variation of Diameter and Environmental Velocity of Carbon Heating Source)

  • 배강열;이윤환;이상용;이칠순;김봉곤;이상철
    • 동력기계공학회지
    • /
    • 제10권4호
    • /
    • pp.25-30
    • /
    • 2006
  • This paper represents the numerical analysis in unsteady state on the variation of diameter and environmental velocity of carbon heating source. In general heating system, the oil and sheath heater is widely used, but these systems have many problems. So, the heating source with carbon ingredient has been researched in many country about manufacture, thermal and electrical properties. In this research, the carbon heating source was studied through numerical analysis on several conditions of unsteady state, heat generation, diameter and environmental velocity. The temperature distributions at steady state are appeared as a non-proportional linear pattern with variations of environmental velocity due to the Nesselt number with convective heat flux is proportioned to 0.805 of Reynolds number. As the radius is increasing, the temperature distributions is appeared the minus tilt because of the environmental condition is cooling by constant temperature. So, the correlation equation between temperature at steady state and environmental velocity was obtained.

  • PDF

분산전원의 계통연계를 위한 디젤발전기의 부하변동에 따른 제어기 개발연구 (A study on the Controller Development Depending Load Variation of a Diesel Generator for Power System Connection of Distributed-source)

  • 한상석;한후석;이창구
    • 조명전기설비학회논문지
    • /
    • 제22권5호
    • /
    • pp.53-57
    • /
    • 2008
  • 일반적으로 비상시 전원으로 디젤발전기를 가장 많이 사용하고 있으며, 하이브리드 전원소스(상용전원, 축전지, 연료전지, 태양전지 등)를 사용하여 부하에 안정적인 전력을 공급하기 위한 방법들이 연구되어지고 있다. 최근 비상시 전원으로 가장 많이 사용하고 있는 디젤발전기의 역할이 아주 중요하게 여겨지며, 운영부하에 따라서도 유연하게 동작되어야 하고, 신뢰성도 확보되어야 한다. 따라서 본 연구에서 부하 변동에 따른 최대전력 추종제어 기능이 가능하고, 고조파 억제 기능 및 안정주파수 유지기능이 가능하도록 부하 변동에 따른 디젤발전기의 제어기에 대하여 논하고자 한다.

Accuracy of Current Delivery System in Current Source Data-Driver IC for AM-OLED

  • Hattori, Reiji
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제4권4호
    • /
    • pp.269-274
    • /
    • 2004
  • Current delivery system, in which the analog current produced by a unique DAC circuit is stored into a current-memory circuit and delivered in a time-divided sequence, shows variation of output current as low as 4% in a current source data-driver IC for AM-OLED driven by a current-programmed method without any fuse repairing after fabrication. This driver IC has 54 outputs and can sink constant current as low as 3 ${\mu}A$ with 6-bit analog levels. Such a low current level without variation can hardly be obtained by an ordinary MOS transistor because the current level is in the sub-threshold region and changes exponentially with threshold voltage variation. Thus we adopted a current mirror circuit composed of bipolar transistors to supply well-controlled current within a nano-ampere range.

Reasons for Variation in Sensitivity and Specificity of Visual Inspection with Acetic Acid (VIA) for the Detection of Pre-Cancer and Cancer Lesions of Uterine Cervix

  • Parashari, Aditya;Singh, Veena
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권12호
    • /
    • pp.7761-7762
    • /
    • 2013
  • Alternative strategies such as visual inspection of cervix with acetic acid, are real time, economical and easily implemented methods for cervical cancer screening. However, variable sensitivity and specificity have been observed in various community based studies. The possible reasons could include variation in man power training, light source used for visualization, and preparation of diluted (4-5%) acetic acid and its storage. A standardized protocol for training, teaching material (easy to understand in the local language) for trainees, supervision and reinforcement by intermittent and supplementary training to check the quality of their observation, a standard protocol for preparation dilute acetic acid and its storage and a standard good light source (equivalent to day light) are needed to minimize the variation in sensitivity and specificity of VIA in community settings.

복합진동계의 진동 인텐시티 능동 제어 (Active Control of Vibrational Intensity in a Compound Vibratory System)

  • 김기만
    • 한국정밀공학회지
    • /
    • 제19권6호
    • /
    • pp.109-118
    • /
    • 2002
  • The vibrational intensity and the dynamic response of a compound vibratory system had been controlled actively by means of a feedforward control method. A compound vibratory system consists of a flexible beam and two discrete systems - a vibrating source and a dynamic absorber. By considering the interactive motions between discrete systems and a flexible beam, the equations of motion for a compound vibratory system were derived using a method of variation of parameters. To define the optimal conditions of a controller the cost function, which denotes a time averaged power flow, was evaluated numerically. The possibility of reductions of both of vibrational intensity and dynamic response at a control point located at a distance from a source were fecund to depend on the positions of a source, a control point and a controller. Especially the presence of a dynamic absorber gives the more reduction on the dynamic response but the less on the vibrational intensity than those without a dynamic absorber.

밭경사에 따른 강우유출수 내의 비점오염물질 특성 비교 분석 (A study on Compare Characteristics of Nonpoint Source in Storm-water versus Steepness of Field Slope)

  • 김기철;최용훈;원철희;최중대
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2009년도 학술발표회 초록집
    • /
    • pp.1093-1102
    • /
    • 2009
  • This study was focused on analyse Nonpoint source characteristics from Flat slope field and Steep slope field. We performed Storm-water monitering for obtain flow data and concentration data. Totally, eleven times Event was occurred. We calculated EMC(Event Mean Concentration) and Pollutants Loads using data we obtained. As a result, steep slope field has more discharge than flat field. SS value, one of the water quality contents, has largest variation and T-N has least variation. There is runoff differences even though events has same rainfall. We assume that not only amount of Rainfall, but also Rainfall Duration Times, Intensity, Number of Previous Non-precipitation days can affect to Run-off.

  • PDF

Temperature Stable Current Source Using Simple Self-Bias Circuit

  • Choi, Jin-Ho
    • Journal of information and communication convergence engineering
    • /
    • 제7권2호
    • /
    • pp.215-218
    • /
    • 2009
  • In this paper, temperature stable current and voltage references using simple CMOS bias circuit are proposed. To obtain temperature stable characteristics of bias circuit a bandgap reference concept is used in a conventional circuit. The parasitic bipolar transistors or MOS transistors having different threshold voltage are required in a bandgap reference. Thereby the chip area increase or the extra CMOS process is required compared to a standard CMOS process. The proposed reference circuit can be integrated on a single chip by a standard CMOS process without the extra CMOS process. From the simulation results, the reference current variation is less than ${\pm}$0.44% over a temperature range from - $20^{\circ}C$ to $80^{\circ}C$. And the voltage variation is from - 0.02% to 0.1%.

Er-doped Superfluorescent Fiber Source with Thermally Stable Mean Wavelength

  • Park, Hee-Gap;Yun, Seung-Chul;Jin, Young-Jun
    • Journal of the Optical Society of Korea
    • /
    • 제13권2호
    • /
    • pp.240-244
    • /
    • 2009
  • An Er-doped superfluorescent fiber source is designed and constructed with the double-pass forward configuration, which aims at high stability of its mean wavelength against temperature variation. As a result, thermal stability of mean wavelength better than 1 ppm is obtained against the temperature variation of ${\pm}5^{\circ}C$ around the optimum operating temperature. The optimum operating temperature can be tuned with the Er-doped fiber length and the pump power.

지열히트펌프의 작동시간 경과에 따른 COP 변화에 대한 연구 (Study on COP Variations with the duration of Ground Source Heat Pump Systems Operation)

  • 이용규;백남춘;윤응상
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.198.2-198.2
    • /
    • 2010
  • In this study, the COP variation with the duration of Ground Source Heat Pump (GSHP) systems operation was analyzed by experiment. This experimental facility was installed in residential house as a back-up device of solar thermal heating system. The capacity of heat pump is 2.5 kW with a vertical bore hole of 150m depth. The COP of GSHP is varied, depending on the ground temperature which is used as a heat source. The ground heat source temperature influencing heating COP is the soil or rock temperature which adjoin with geo-source heat exchanger. This temperature is decreased rapidly according to the operation duration of heat pump. As a result, COP of GSHP is decreased to 3 in one hour of continuous operation time.

  • PDF