• Title/Summary/Keyword: Variation Part

Search Result 1,544, Processing Time 0.027 seconds

A Study on Composition of Municipal Solid Wastes and Characteristics of Leachate in In-Cheon Sanitary Landifil Site (인천시 위생매립지 쓰레기 조성 및 침출수 특성에 관한 연구)

  • 박석환;정문식
    • Journal of Environmental Health Sciences
    • /
    • v.18 no.1
    • /
    • pp.63-68
    • /
    • 1992
  • This study was performed to investigate the seasonal variation of the composition of domestic solid wastes and the characteristics of the leachate sampled in In-Cheon sanitary landfill site. The results were as follows 1. Combustible part was larger than incombustible part of the domestic solid wastes in spring and sumer. 2. The food waste was major source of solid wastes in In-Cheon city as 36.5%, and its variation by seasons was negligible. 3. BOD of the leachate was in the range of 853~7, 350mg/l, and fluctuated by seasons. 4. The mean of COD$_{cr}$ Was 5, 044mg/l, the mean of COD$_{Mn}$ was 2, 212mg/l. Namely, the method by $K_{2}Cr_{2}O_{7}$ was more sensitive than the method by KMnO$_{4}$. 5. TOC was in the range of 773~3, 958mg/l, it was lower than BOD.

  • PDF

An Study on Efficiency and Application of Thermal Siphon in the Permafrost (영구동토 지대에서 Thermal Siphon의 효율성 연구)

  • Kang, Jae-Mo;Kim, Hak-Seung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.963-966
    • /
    • 2009
  • A Construction of pipe line foundation and railroad, buildings in a permafrost area requires engineering technology of ground stabilization. In the permafrost area, thermal siphons have been used to stabilize foundation by eliminating the heat of ground to the air. the thermal siphon is a passive heat transfer device that operates by convection through vaporization and condensation. The heat transfer from ground to the air is driven by a temperature difference across the unit. A buried part in ground working as vaporizing function and upper part work as condensing. In this study, buried thermal siphon around the pipe lines laid in the Vladivostok site and measuring temperature variation. It is found that the thermal siphons freezing ground faster and decrease temperature variation in winter season.

  • PDF

Extraction Rate and Temperature Dependency of Distribution Ratio of 4f and 5f Series Element in the Various Phosphorus Compounds (各種 燐化合物溶媒 抽出系에 있어서 4f 및 5f 系列 元素의 抽出速度 및 分配率의 溫度依存性)

  • Rhee, Chin-Taik
    • Journal of the Korean Chemical Society
    • /
    • v.13 no.3
    • /
    • pp.199-204
    • /
    • 1969
  • The distribution rate of 4f and 5f series elements in chelate and ion association extraction system was studied. Clear difference between lighter and heavier part of 4f series are observed. Trivalent Am and Cm were appeared to be grouped into the lighter part of 4f series. And also the variation of distribution ratio according to the varied temperature was studied. The variation modes of distribution ratio are different according to the extraction system. Atomic number dependence in the chelate extraction system was observed.

  • PDF

Temperature-time analysis for steel structures under fire conditions

  • Wong, M.B.;Ghojel, J.I.;Crozier, D.A.
    • Structural Engineering and Mechanics
    • /
    • v.6 no.3
    • /
    • pp.275-289
    • /
    • 1998
  • The objective of the paper is to present a method whereby the time required for a steel structure to sustain the effects of a prescribed temperature rise according to real fire curves can be calculated. The method is divided into two parts. The first part deals with the post-yield behaviour of steel structures at elevated temperatures. It takes into account the variation of the properties of steel material with temperature in an incremental elastoplastic analysis so that the safety factor of the structure under certain fire conditions can be assessed. The second part deals with the heat transfer problem of bare steel members in real fire. Factors affecting the heat transfer process are examined and a model for predicting the temperature variation with time under real fire conditions is proposed. This model results in more accurate temperature predictions for steel members than those obtained from previously adopted model.

Hydraulic Model Experiment for Field Application of Iceharbor-type Precast Fishway (조립식 아이스하버식 어도의 현장 적용을 위한 수리모형실험)

  • Kim, Jae-Ok;Park, Sang-Hyun;Cho, Jae-Won;Hwang , Jong-Seo;Jo , Guk-Hyun;Joh , Seong-Ju
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.2
    • /
    • pp.3-14
    • /
    • 2004
  • This study was conducted to assess the possibility of the field application of the iceharbor-type precast fishway. When overflow depth of weir is 4.0 cm in model fishway, upper part velocities appear appropriate for upstream migration of fish and the lowest overflow wall (right line) in lower part has shown velocity distribution more or less inadequate for upstream migration. Except that right line, left and middle line revealed that velocities are appropriate for upstream migration of fish. Therefore, we concluded that this fishway owing to be not broad growth width of overflow velocities according to increasing discharges can correspond to variation of water level. Also We consider that various velocities in fishway were effective, because slow velocity line can guide flow for upstream migration. For low flow, the arrangement of different crest level or each overflow part (higher left, middle and lower right, or lower left, middle and higher right) was more effactive than unform crert level. Hole plays an important role as migration pass during drought and flood flow. Therefore, We concluded that this fishway can cope with water depth variation by various overflow wall height change and raise the field applicability with better performance hydraulically and structurally.

NUMERICAL STUDY OF TURBULENT FLOW IN A INTAKE PART OF VACUUM CLEANER WITH ROLLING BRUSH (회전브러시가 장착된 진공청소기 흡입장치의 난류유동에 대한 수치해석)

  • Park, Tae-Seon
    • Journal of computational fluids engineering
    • /
    • v.17 no.2
    • /
    • pp.58-64
    • /
    • 2012
  • Turbulent flows in a intake part of vacuum cleaner are studied by RANS simulations. The governing equations are solved by the SIMPLE algorithm based on the finite volume method of the unstructured grid system. The predicted results show that the suction performance is closely related to the variation of flow structure in the intake part. In order to investigate for the cleaning of bedclothes and carpet without sticking, several design changes are applied. The introduction of a solid cylinder in the intake part changes vortical structures significantly. Based on this result, a new design with spiral brushes is proposed. The design shows a good behavior for the suction performance and the flow control.

Composition and Evaluation of the Thermal Desorption-Gas Chromatographic System for the Measurement of Volatile Organic Compounds in Air (공기 중 휘발성 유기화합물의 측정을 위한 열탈착-분석시스템의 구성 및 평가)

  • 이수형;송희남;김희갑
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.1
    • /
    • pp.63-71
    • /
    • 2002
  • The thermal desorption-gas chromatographic (TD-GC) system has been constructed for the measurement of volatile organic compounds. The thermal desortion unit is composed of four major parts: 1) the control part; 2) the thermal desorption part; 3) the focusing part; and 4) the injection part. The peltier element was introduced to the focusing part for the temperature of the focusing tube to reach-35$^{\circ}C$. The system was tested for the linearity of the calibration curves and reproducibility of instrumental analyses using some disinfection by-products (DBPs) and BTXs (benzene, toluene and p-xylene). The coefficients of determination (r$^2$) for all the calibration curves made were higher than 0.998, and the coefficients of variation (CV) for triplicate measurements were all within 10%. The system also has been tested for field applicability. The analysis of field samples showed that there was no breakthrough problem in the sampling system and that the system could be applied to field measurements.

Isolated Words Recognition using Correlation VQ-HMM (상관성있는 VQ-HMM을 이용한 고립 단어 인식)

  • 이진수
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1993.06a
    • /
    • pp.109-112
    • /
    • 1993
  • In this paper, we propose the modified VQ, applied correlation between codewords in order to reduce the error rate due to personal and speakers' temporal variation. Such a modified VQ is used in the stage of preprocessing of HMM and the temporal variation is absorbed by nonlinear Decimation and Interpolation of vowel part that we obtain higher recognition rate than not so case. The objects of experiment are Korea 142 DDD regional names and we show that the proposed method increase the recognition rate.

  • PDF