• 제목/요약/키워드: Variance/Mean Ratio

검색결과 165건 처리시간 0.03초

한국중년층에서 체질량지수, 허리-엉덩이둘레비, 및 허리둘레의 심장혈관계질환 위험인자 타당도 비교 (Comparing validity of using Body Mass Index, Waist to Hip Ratio, and Waist Circumference to Cardiovascular Risk Factors of Middle Aged Koreans)

  • 문현경;김유진
    • 대한영양사협회학술지
    • /
    • 제11권3호
    • /
    • pp.365-374
    • /
    • 2005
  • This study was conducted to compare the validity of obese index among body mass index(BMI), waist to hip ratio(WHR), and waist circumference(WC) and to determine which is the best in relation to cardiovascular risk factors of middle aged Korean(40-64yr).Data from the 1998 Korean Health and Nutrition Survey were used(N=3380). Anthropometric indices and cardiovascular risk factors were measured. Chi-square test, analysis of variance following duncan's multiple range test, partial correlation analysis, and Receiver Operator characteristic(ROC) curves were used in the analysis. There was a significant increasing trend in WHR, systolic blood pressure(SBP), high density lipoprotein cholesterol(HDL), and fasting blood sugar(FBS) with age categories of male and in BMI, WC, WHR, diastolic blood pressure(DBP), SBP, total cholesterol(TC), low density lipoprotein cholesterol(LDL), triglycerol(TG), and FBS with those of female. Specially female had the characteristics of upper body fat and systolic blood pressure risk(p<0.05). Proportions of subjects with lifestyle factors related to cardiovascular risk in overweight or upper body fat group were higher than that of normal group. Higher proportions of subjects were practiced exercise in upper body fat group of male than in other groups. Among 7 cardiovascular risk factors in partial correlation analysis, BMI had the highest correlation coefficient in 6 risk factors in male, whereas WC in 4 risk factors in female. Mean of each obese index according to cardiovascular risk groups except smoker was higher than that of normal(p<0.05). These trends were shown in upper body fat group and female. In ROC analysis of 12 risk factors and health conditions, the largest area under curve among obese indices for risk factors were BMI in male and WHR in female. The optimal cutoff values of each index(BMI: WHR: WC) for one or more cardiovascular risk factors were 23.13: 0.89: 85.35 in male and 23.57: 0.84: 78.35 in female. The results showed that cardiovascular risk factors were prevalent in middle aged Koreans within normal limits of obese indices like another Asians. For the identification of cardiovascular risk factors of middle aged Koreans, BMI for men and WHR for women are appropriate indices. But it is recommended that BMI, WHR, and WC, all three indices should be considered, when using these indices.

  • PDF

심근조영심초음파에서 심장의 움직임을 보정한 비침습적 심근관류모델의 정량적 평가

  • 이재훈;김희중;정남식;임세중;김기황
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.49-49
    • /
    • 2003
  • 목적 : 심초음파는 비침습적이므로 반복적으로 정확히 심질환의 경과를 관찰하여 치료효과 및 수술시기를 정할 수 있는 검사로서 임상적으로 매우 유용하다. 실시간 심근조영심초음파에 의한 time intensity 평가는 부위별로 수행됨으로 연속적으로 위치하는 관심영역이 intensity에 있어 심장의 움직임 변화에 영향을 받는다. Time intensity 곡선의 최적의 곡선맞춤을 위해 주기적인 심장 운동 매개변수를 조합해 기존의 모델을 보정한 안정적인 측정방법을 제시한다. 방법 : 심장의 운동에 의한 특징적인 정보를 설명하기 위해 기존의 문헌에 제시된 지수 함수에 주어진 심박수로 만들어진 시간에 관한 일반적인 정형파 함수를 추가한다. C(t) = A[1 - exp($\beta$t)] + Dsine(2$\pi$ft + $\theta$) C(t): videointensity A: plateau videointensity (blood volume) $\beta$: capillary blood velocity (rate constant of rise in videointensity) t: pulsing interval (ms) D: displacement from the periodic variance of the curve (estimated motion field from the ejection point for the ratio between systole and diastole) f: heart rate $\theta$: transit time issue A $\times$ $\beta$ : myocardial blood flow 관상동맥의 관류 데이터에 대한 실험이 펄스간격에 대한 비디오 세기로 수행되었다. 그리고 이러한 결과들이 the sum of squares due to error, R square, root mean squared error로 평가되었다. 결과 : 실험결과, 주기적인 심장의 움직임과 심박출 시점으로부터의 변위를 잘 기술하고 곡선에서의 측정 점들이 예측된 심장 움직임에 따라 성공적으로 표시되었다. 뿐만 아니라 보정된 모델이 현저한 적합도의 향상을 보여주었다. 결론 : 제시된 접근방법은 각각의 측정에서 심장 운동 영역의 변화에 독립적이며 측정 시점에 의해 영향받지 않고 심근 관류의 안정적인 측정이 가능하다. 심장의 움직임에 관한 매개변수를 조합한 모델로 곡선접합을 수행함으로써 관류의 정량적 정보를 좀더 정확하게 얻을 수 있으며 임상적 이용을 가능하게 할 것으로 기대된다.

  • PDF

무지외반이 족관절 저굴근과 배굴근의 우력에 미치는 영향 (The effects of hallux valgus on ankle plantarflexor and dorsiflexor torque)

  • 이윤섭;권영실;송주영;남기원;송주민;구상훈;최현임;최진호;김진상
    • The Journal of Korean Physical Therapy
    • /
    • 제13권2호
    • /
    • pp.325-333
    • /
    • 2001
  • The purpose of this study was to find out the effects of hallux valgus on the ankle plantarflexor and dorsiflexor peak torque, on the total work, on the average power, and on the Peak torque of plantarflexor to dorsiflexor ratio values. Isokinetic ankle plantarflexor and dorsiflexor strength was evaluated in 30 women(control: 15, hallux valgus: 15) by Cybex NORM System. Test data was gathered in the right ankle at a speed of 60/sec, 90/sec, 120/sec in the control group and the hallux valgus group. Statistical analysis was performed using SPSS 10.0 for windows software. Mean and standard deviations were measured and calculated for the General characterristic of subjects. A paired t-test was used to examine the differnces in the means for the ankle plantarflexor and dorsiflexor between two groups. Pearson coefficient correlation was used to examine the correlation of the hallux valgus and the peak torque. Analysis of variance indicated that isokinetic values of the control group were greater than the hallux valgus group(p<.05, p<.01).

  • PDF

Quantitative Evaluation of Median Nerve Motor Function in Carpal Tunnel Syndrome Using Load Cell : Correlation with Clinical, Electrodiagnostic, and Ultrasonographic Findings

  • Kim, Dong Hwan;Park, Sung Bae;Lee, Sang Hyung;Son, Young-Je;Chung, Gih Sung;Yang, Hee-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • 제54권3호
    • /
    • pp.232-235
    • /
    • 2013
  • Objective : Major complaints of carpal tunnel syndrome (CTS) are sensory components. However, motor deficit also impedes functional status of hand. Contrary to evaluation of sensory function, the objective, quantitative evaluation of median nerve motor function is not easy. The motor function of median was evaluated quantitatively using load cell and its correlation with findings of electrodiagnostic study (EDS) was evaluated. Methods : Objective motor function of median nerve was evaluated by load cell and personal computer-based measurement system. All of the measurement was done in patients diagnosed as having idiopathic CTS by clinical features and EDS findings. The strength of thumb abduction and index finger flexion was measured in each hand three times, and the average value was used to calculate thumb index ratio (TIR). The correlation of TIR with clinical, EDS, and ultrasonographic findings were evaluated. Results : The TIR was evaluated in 67 patients (119 hands). There were 14 males and 53 females, mean age were 57.6 years (range 28 to 81). The higher preoperative nerve conductive studies grade of the patients, the lower TIR was observed [p<0.001, analysis of variance (ANOVA)]. TIR of cases with thenar atrophy were significantly lower than those without (p<0.001, t-test). TIR were significantly lower in patients with severe median nerve swelling in ultrasonography (p=0.042, ANOVA). Conclusion : Measurements of median nerve motor function using load cell is a valuable evaluation tool in CTS. It might be helpful in detecting subclinical motor dysfunction before muscle atrophy develops.

갑상선 종양에서 아포프토시스(Apoptosis)와 세포증식 표지자(Ki-67)의 상관관계 분석 (Correlation Analysis of Apoptosis and Cell Proliferating Marker (Ki-67) in Thyroid Tumors)

  • 한경희;양우익;김선정;김태전
    • 대한임상검사과학회지
    • /
    • 제39권3호
    • /
    • pp.241-248
    • /
    • 2007
  • To clarify the growth mechanisms of thyroid tumors, we investigated apoptotic cells in 88 thyroid tumors, consisting of 24 adenomas, 58 papillary thyroid carcinomas, and 6 undifferentiated carcinoma, using terminal deoxynucleotidyl transferase mediated deoxyuridine triphosphate digoxigenin-nick end labeling (TUNEL). The cell proliferating marker was also evaluated immunohistochemically using the monoclonal antibody to Ki-67 antigen (MIB-1) in the same tumors. The apoptosis was expressed as a percentage of the TUNEL-positive cells in the tumor cells, and a proliferating marker, being the percentage of Ki-67 positive cells, was counted up each tumor. The statistical analysis were used analysis of variance (ANOVA) and student's t-test that were analyze the differences in the rate of each histological types of the thyroid tumors. The overall level of apoptosis was extremely low in all histological types of the thyroid tumors analyzed, the mean apoptosis being $0.31{\pm}0.40$ in adenoma, $0.55{\pm}0.48 $in papillary thyroid carcinoma, and $4.60{\pm}3.27$ in undifferentiated carcinoma. The Ki-67 protein in the thyroid tumor subtypes was significantly lower in adenoma and papillary carcinoma, at $2.45{\pm}2.99$ and $6.27{\pm}4.42$, respectively, than that in undifferentiated carcinoma at $26.47{\pm}23.88$ (p<0.0001). There was no correlation between clinicopathological factors and apoptosis or Ki-67 in papillary thyroid carcinoma. In conclusion, our findings suggest that apoptosis occurs infrequently in thyroid tumor, and that cell proliferating maker Ki-67 markedly differs according to the thyroid tumor subtypes. Moreover, the ratio between proliferating cells and apoptotic cells may reflect thyroid tumor progression.

  • PDF

Accelerated Resting-State Functional Magnetic Resonance Imaging Using Multiband Echo-Planar Imaging with Controlled Aliasing

  • Seo, Hyung Suk;Jang, Kyung Eun;Wang, Dingxin;Kim, In Seong;Chang, Yongmin
    • Investigative Magnetic Resonance Imaging
    • /
    • 제21권4호
    • /
    • pp.223-232
    • /
    • 2017
  • Purpose: To report the use of multiband accelerated echo-planar imaging (EPI) for resting-state functional MRI (rs-fMRI) to achieve rapid high temporal resolution at 3T compared to conventional EPI. Materials and Methods: rs-fMRI data were acquired from 20 healthy right-handed volunteers by using three methods: conventional single-band gradient-echo EPI acquisition (Data 1), multiband gradient-echo EPI acquisition with 240 volumes (Data 2) and 480 volumes (Data 3). Temporal signal-to-noise ratio (tSNR) maps were obtained by dividing the mean of the time course of each voxel by its temporal standard deviation. The resting-state sensorimotor network (SMN) and default mode network (DMN) were estimated using independent component analysis (ICA) and a seed-based method. One-way analysis of variance (ANOVA) was performed between the tSNR map, SMN, and DMN from the three data sets for between-group analysis. P < 0.05 with a family-wise error (FWE) correction for multiple comparisons was considered statistically significant. Results: One-way ANOVA and post-hoc two-sample t-tests showed that the tSNR was higher in Data 1 than Data 2 and 3 in white matter structures such as the striatum and medial and superior longitudinal fasciculus. One-way ANOVA revealed no differences in SMN or DMN across the three data sets. Conclusion: Within the adapted metrics estimated under specific imaging conditions employed in this study, multiband accelerated EPI, which substantially reduced scan times, provides the same quality image of functional connectivity as rs-fMRI by using conventional EPI at 3T. Under employed imaging conditions, this technique shows strong potential for clinical acceptance and translation of rs-fMRI protocols with potential advantages in spatial and/or temporal resolution. However, further study is warranted to evaluate whether the current findings can be generalized in diverse settings.

국부 공간 제약 정보 및 예측 노이즈 특성을 이용한 적응 Gradient-Projection 영상 복원 방식 (An Adaptive Gradient-Projection Image Restoration using Spatial Local Constraints and Estimated Noise)

  • 홍민철
    • 한국통신학회논문지
    • /
    • 제32권10C호
    • /
    • pp.975-981
    • /
    • 2007
  • 본 논문에서는 공간 영역의 국부 정보 및 반복 영상으로부터 예측된 노이즈를 이용한 적응 영상 복원 방식을 제안한다. 공간 영역의 국부 제약 정보 설정을 위해 서로 다른 윈도우를 갖는 국부 영역의 평균, 분산 및 최대 값의 비를 이용하였으며, 반복 기법을 이용하여 매 반복 해에서 얻어진 복원 영상으로부터 상기 제약 정보를 설정하게 된다. 더불어 반복 영상으로부터 예측된 노이즈와 국부 제약 정보를 이용하여 국부 완화도 정도를 결정하는 매개 변수를 적응적으로 산출한다. 제안된 방식을 이용하여 복원 영상을 얻기 위해 비 적응 복원 방식보다 빠른 수렴속도를 갖게 됨을 알 수 있으며, 노이즈 특성에 대한 사전 정보 없이 국부적으로 제어된 완화 정도를 지닌 복원 영상을 얻을 수 있었다. 기존 방식과 비교하여 제안방식은 수렴하기 유사한 반복 횟수를 필요로 하며 0.2 dB 이상의 SNR 향상이 있음을 확인할 수 있었다.

직사각형 검사영역의 상관도 분석을 통한 수면위치 탐색 방법 (A Novel Water Surface Detection Method Based on Correlation Analysis for Rectangular Control Area)

  • 이찬주;서명배;김동구;권성일
    • 한국수자원학회논문집
    • /
    • 제45권12호
    • /
    • pp.1227-1241
    • /
    • 2012
  • 본 연구에서는 목자판과 수면이 포함되어 있는 시차를 가진 두 영상에 대해 직사각형 검사영역을 설정하고 그 상관계수를 분석하여 수면을 판단하는 새로운 수면인식 기법을 제안하였다. 상관계수의 수직적인 값들로부터 임계치, 첨두값, 기울기, 분산비 등 4가지 방법을 이용하여 수면의 위치를 판정하였다. 흔들림 등으로 인해 두 영상의 위치가 불일치하여 생기는 문제를 제거하기 위해 추가로 영상의 흔들림을 보정하는 알고리즘과 통계적 필터링 기법을 적용하였다. 저수시에 촬영한 28개 지점의 영상에 개발한 수면 인식 방법을 적용하였다. 이 방법으로 계산한 수면은 목측 수면과의 평균상대오차가 3.4~5.7 cm 정도로 나타났다. 수면의 요동이 있을 경우, 이 방법은 기존 방법을 보완하여 영상수위계의 수위 측정성능을 높이는데 활용될 수 있을 것이다.

Tensile bond strength between auto-polymerized acrylic resin and acrylic denture teeth treated with MF-MA solution

  • Thongrakard, Ticha;Wiwatwarrapan, Chairat
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권4호
    • /
    • pp.285-289
    • /
    • 2016
  • PURPOSE. This study evaluated the effect of chemical surface treatment using methyl formate-methyl acetate (MF-MA) solution on the tensile bond strength between acrylic denture teeth and auto-polymerized acrylic resin. MATERIALS AND METHODS. Seventy maxillary central incisor acrylic denture teeth for each of three different brands (Yamahachi New Ace; Major Dent; Cosmo HXL) were embedded with incisal edge downwards in auto-polymerized resin in polyethylene pipes and ground with silicone carbide paper on their ridge lap surfaces. The teeth of each brand were divided into seven groups (n=10): no surface treatment (control group), MF-MA solution at a ratio of 25:75 (v/v) for 15 seconds, 30 seconds, 60 seconds, 120 seconds, 180 seconds, and MMA for 180 seconds. Auto-polymerized acrylic resin (Unifast Trad) was applied to the ground surface and polymerized in a pressure cooker. A tensile strength test was performed with a universal testing machine. Statistical analysis of the results was performed using two-way analysis of variance (ANOVA) and post-hoc Dunnett T3 test (${\alpha}$=.05). RESULTS. The surface treatment groups had significantly higher mean tensile bond strengths compared with the control group (P<.05) when compared within the same brand. Among the surface treatment groups of each brand, there were no significantly different tensile bond strengths between the MF-MA groups and the MMA 180 second group (P>.05), except for the Yamahachi New Ace MF-MA 180-second group (P<.05). CONCLUSION. 15-second MF-MA solution can be an alternative chemical surface treatment for repairing a denture base and rebonding acrylic denture teeth with auto-polymerized acrylic resin, for both conventional and cross-linked teeth.

Pharmacokinetics of Two Cyclosporine Formulations Using FPIA and HPLC Assay in Volunterrs

  • Kwon, Kwang-Il;Kim, Moo-Heon;Park, Jong-Woo;Lee, Chang-Hyun
    • Archives of Pharmacal Research
    • /
    • 제18권6호
    • /
    • pp.385-390
    • /
    • 1995
  • The analytical methods for the analysis of cyclosporine (CsA), a fluorescence polarization immunoassay (FPIA) and HPLC method, were compared in a pharmacokinetic study of two CsA soft capsule formultaions ($Sandimmun^{\circledR}$; Sandoz, $Implanta^{\circledR}$; Hanmi). Sixteen healthy volunteers completed the study and each subjected single doses ($4{\tiems}100$ mg) of the test and the reference formulations in a two-way crossover design with a one-week drug-free interval between doses. Following each administration, whole blood concentrations of CsA were monitored over a period of 24 hour by both FPIA and HPLC methods. Blood concentrations nad pharmacokinetic parameters determined by either analytical method showed large intersubject variation, with the FPIA data showing relatively higher magnitude of intersubjecte variation than the HPLC data. The blood concentrations determined by FPIA were 1.1-1.3 times higher than those determined by HPLC. There were strong and significant correlations between the two methods (r>0.83 : p<0.0001). Intersubuject variation for the $AUC_{inf}{\;}and{\;}AUC_{24hr}$ of the test formulation was slightly reduced without statistical significance (paried -t test : p>0.05 $t_{max}$ was earlier nad $C_{max}$ was slightly lower for the test formulation, $AUC_{24h}, {\;}C_{max}, {\;}T_{max}$ and MRT determined separately from the data obtained by the two methods for the two formulations were examined by analyses of variance (ANOVA) for the bioequivalency evaluation. Results of ANOVA and confidence limits of terst/reference ratios of $AUC_{24th}$, $C_{max}$, $t_{max}$ and MRT, and statistical tests indicated the bioequivalence of the two formulations (i.e., test/reference ratio was within $100{\times}20%$) except for $C_{max}$ and $t_{max}$. The mean of tmax also showed 11.1% and 9.3% differences but the detection limit were 29.2% and 29.6% as determined by FPIA and HPLC resepctively. This experiments suggest that the data yielded for the two formulations demonstrated that they were bioequivalent.

  • PDF