• 제목/요약/키워드: Variable-Pressure

검색결과 1,153건 처리시간 0.025초

Numerical prediction of the proximity effects on wind loads of low-rise buildings with cylindrical roofs

  • Deepak Sharma;Shilpa Pal;Ritu Raj
    • Wind and Structures
    • /
    • 제36권4호
    • /
    • pp.277-292
    • /
    • 2023
  • Low-rise structures are generally immersed within the roughness layer of the atmospheric boundary layer flows and represent the largest class of the structures for which wind loads for design are being obtained from the wind standards codes of distinct nations. For low-rise buildings, wind loads are one of the decisive loads when designing a roof. For the case of cylindrical roof structures, the information related to wind pressure coefficient is limited to a single span only. In contrast, for multi-span roofs, the information is not available. In this research, the numerical simulation has been done using ANSYS CFX to determine wind pressure distribution on the roof of low-rise cylindrical structures arranged in rectangular plan with variable spacing in accordance with building width (B=0.2 m) i.e., zero, 0.5B, B, 1.5B and 2B subjected to different wind incidence angles varying from 0° to 90° having the interval of 15°. The wind pressure (P) and pressure coefficients (Cpe) are varying with respect to wind incidence angle and variable spacing. The results of present numerical investigation or wind induced pressure are presented in the form of pressure contours generated by Ansys CFD Post for isolated as well as variable spacing model of cylindrical roofs. It was noted that the effect of wind shielding was reducing on the roofs by increasing spacing between the buildings. The variation pf Coefficient of wind pressure (Cpe) for all the roofs have been presented individually in the form of graphs with respect to angle of attacks of wind (AoA) and variable spacing. The critical outcomes of the present study will be so much beneficial to structural design engineers during the analysis and designing of low-rise buildings with cylindrical roofs in an isolated as well as group formation.

증기터빈의 가변패킹 형태에 따른 터빈성능 평가에 관한 연구 (A Study on the Turbine Performance in the steam seal variable clearance packing type of Steam turbine)

  • 권영수;서정세
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1676-1681
    • /
    • 2004
  • The main reason for applying positive pressure variable clearance packing in fossil power plant is high efficiency and energy saving movement in the government. This study intends to analyze the turbine efficiency through the shaft packing improvement in thermal power plant and makes its comparison to that of the each packing type

  • PDF

Ambient Variable Pressure Field Emission Scanning Electron Microscopy for Trichome Profiling of Plectranthus tomentosa by Secondary Electron Imaging

  • Kim, Ki Woo
    • Applied Microscopy
    • /
    • 제43권1호
    • /
    • pp.34-39
    • /
    • 2013
  • Glandular and nonglandular trichomes on the leaf surface of Plectranthus tomentosa were investigated by variable pressure field emission scanning electron microscopy (VP-FESEM). The segments of the plant's leaves were directly mounted without any specimen preparation, and examined at ambient temperature using a variable pressure secondary electron (SE) detector under ca. 15 Pa. Foliar trichomes maintained their shapes and structures without severe surface collapse or charging. The adaxial leaf surface was abundantly covered with different types of trichome. Nonglandular trichomes consisted of a basal cell and a long (up to ca. $300{\mu}m$) stalk. Meanwhile, capitate glandular trichomes had a secretory head and a short or long stalk. Peltate glandular trichomes with globose secretory heads were observed in close contact with the leaf epidermis. Spherical projections on the secretory head showed the secretion process of glandular trichomes. In addition to the trichomes, oval stomata were distributed on the abaxial leaf surface. These results suggest that ambient VP-FESEM can be used to classify the dehydration-sensitive foliar trichomes of succulent plants by SE imaging. At the FESEM resolution, this approach facilitates the rapid and detailed morphological analysis of a variety of trichomes in diverse plant taxa with reduced labor and preparation.

가솔린 예혼합 압축 착화 엔진의 농후 한계에서 연소와 노킹 특성 (Knocking and Combustion Characteristics at Rich Limit of Gasoline HCCI Engine)

  • 염기태;장진영;배충식
    • 한국자동차공학회논문집
    • /
    • 제14권6호
    • /
    • pp.9-16
    • /
    • 2006
  • Variable valve timing is one of the attractive ways to control homogeneous charge compression ignition (HCCI) engine. Hot internal residual gas which can be controlled by variable valve timing(VVT) device, makes fuel evaporated easily, and ignition timing advanced. Regular gasoline was used as main fuel and di-methyl ether(DME) was used as ignition promoter in this research. HCCI engine operating range is limited by high combustion peak pressure and engine noise. High combustion pressure can damage the engine during operation. To avoid engine damage, the rich limits have to define using various methods. Peak combustion pressure, rate of cylinder pressure rise was considered to determine rich limit of engine operating range. Knock probability was correlated with the rate of cylinder pressure rise as well as the peak combustion pressure.

가변형 음속 이젝터 유동에 관한 수치해석적 연구 (A Computational Study of a Variable Sonic Ejector Flow)

  • 이준희;최보규;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.526-531
    • /
    • 2003
  • A cone cylinder is used to obtain variable operation conditions of a sonic ejector-diffuser system. The cone cylinder is movable to change the ejector area ratio, thus obtaining variable mass flow rates. The present study investigates the effects of ejector throat area ratio and operating pressure ratio on the entrainment of secondary stream. The numerical simulations are based on a fully implicit finite volume scheme of the compressible, Reynolds-Averaged, Navier-Stokes equations. The ejector throat area is varied between 3.94 and 8.05, and the operating pressure ratio is changed from 3.0 to 9.0. The results show that the entrainment ratio and mass flux ratio become more dependent on the ejector throat area ratio, when the pressure operating ratio is low. The total pressure losses produced in the present ejector system increase with the operating pressure ratio and the ejector area ratio, but for a given operating pressure ratio, the losses are not significantly dependent on the ejector area ratio when it is larger than about 5.0.

  • PDF

Magnetohydrodynamic peristalsis of variable viscosity Jeffrey liquid with heat and mass transfer

  • Farooq, S.;Awais, M.;Naseem, Moniza;Hayat, T.;Ahmad, B.
    • Nuclear Engineering and Technology
    • /
    • 제49권7호
    • /
    • pp.1396-1404
    • /
    • 2017
  • The mathematical aspects of Dufour and Soret phenomena on the peristalsis of magnetohydrodynamic (MHD) Jeffrey liquid in a symmetric channel are presented. Fluid viscosity is taken variably. Lubrication approach has been followed. Results for the velocity, temperature, and concentration are constructed and explored for the emerging parameters entering into the present problem. The plotted quantities lead to comparative study between the constant and variable viscosities fluids. Graphical results indicate that for non-Newtonian materials, pressure gradient is maximum, whereas pressure gradient is slowed down for variable viscosity. Also both velocity and temperature in the case of variable viscosity are at maximum when compared with results for constant viscosity.

자동차용 촉매변환기의 활성화 성능 향상을 위한 횡방향 가변 셀 밀도법의 수치적 평가: 활성화 촉매변환기를 중심으로 (Numerical Evaluation of a Radially Variable Cell Density Strategy for Improving Light-off Performance: Focusing on Light-off Catalyst)

  • 정수진;김우승
    • 한국자동차공학회논문집
    • /
    • 제10권1호
    • /
    • pp.115-124
    • /
    • 2002
  • The optimum design of auto-catalyst needs a good compromise between the pressure drop and flow distribution in the monolith. One of the effective methods to achieve this goal is to use the concept of radially variable cell density. However, there has been no study of evaluating the usefulness of this method on light-off catalyst. We have computationally investigated the effectiveness of variable cell density technique applied to the light-off catalyst using a three-dimensional integrated CFD model. in which transient chemical reacting calculations are involved. Computed results show that variable cell density technique can reduce the accumulated emissions of CO and HC during the early 100sec of FTP cycle by 86.78 and 80.87%, respectively, The effect of air-gap between the monoliths has been also examined. It is found that air-gap has a beneficial effect on reducing pressure drop and cold-start emissions.

VVVF기를 기초한 가변식기압급수설비의 자동제어 문제 (Automatic control problems of VVVF converter-based variable-frequency type air)

  • 박용규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.468-468
    • /
    • 1991
  • The variable-frequency type water supply equipment, which adopts the variable-voltage and variable-frequency converter(VVVF converter) to govern automatically the rotating speed of a pump, can save 15-20% of power, as compared with a throttle-controlled pump device or an airpressurized water supply equipment, and is finding a wide application. However, it still has some disadvantages : greater pressure fluctuations during switching over the pump and prolonged low-effeciency running of the pump in the case of small consumption of water. Therefore, it is difficult to apply the equipment to the fire water supply system where the water should not be put into use unless a fire takes place, and the water pressure in pipelines should permanently remain constant. This paper introduces the automatic regulation principle of the variable-frequency type air-pressurized water supply equipment (hereafter referred to as simply BFQS equipment) for dual purposes of daily life and fire control, which combined both technologies of speed governing by a converter and air-pressurized water supplying, then discusses some problems related to automatic control, and finally gives the experimental results of an embodiment-BPQS-100-50 water supply equipment.

  • PDF

극저온 정압 저널베어링의 성능해석에 관한 연구 : 난류유동, 압력강하, 가변 밀도 및 점도의 영향 (A Study on Performance Analysis of Cryogenic Hydrostatic Journal Bearings : the Effects of Turbulent Flow, Pressure Drop and Variable Liquid Properties)

  • 김성기;강지훈;김경웅
    • Tribology and Lubricants
    • /
    • 제19권3호
    • /
    • pp.139-145
    • /
    • 2003
  • In this paper, static characteristics of a cryogenic hydrostatic journal bearing which has 2-rows staggered recesses are numerically analyzed. The regime of operation of this bearing is fully turbulent with large fluid inertia effects. The turbulent lubrication equation is solved under the assumption that turbulence parameters are decided by the Reynolds numbers. Pressure drop caused by inertia effect at the recess edge is considered in this analysis. Also density and viscosity of working fluid are considered as function of only pressure. Numerical results for a cryogenic Hydrostatic journal bearing show pressure distribution, load capacity, flow rate, and recess pressure. The effects of turbulent flow, pressure drop and variable liquid properties are discussed.

상온기체 모사장치를 이용한 가변추력 고체추진기관의 압력제어 연구 (A Study on Pressure Control for Variable Thrust Solid Propulsion System Using Cold Gas Test Equipment)

  • 이호성;이도윤;박종승;김중근
    • 한국항공우주학회지
    • /
    • 제37권1호
    • /
    • pp.76-81
    • /
    • 2009
  • 본 논문에서는 가변 추력 고체추진기관을 모사할 수 있는 상온기체 시험장치를 이용하여 고체추진기관의 연소실 압력을 능동적으로 제어할 수 있는 비선형 압력 제어알고리듬을 제안하였다. 제안된 제어기법은 고체추진기관의 비선형성과 시변성을 고려하여 설계되었으며, 압력 및 온도조건 등에 따른 물리적 변수들의 변화를 적응제어 알고리듬을 통하여 보상하였다. 비선형 압력제어 알고리듬의 효과를 상온기체 모사장치를 이용한 압력제어 실험을 통하여 검증하였으며, 실험결과 일반적인 비례 제어기 및 비례-적분 제어기에 비하여 제안된 제어기법이 더 좋은 압력제어 성능을 보임을 확인하였다.