• 제목/요약/키워드: Variable wavelength

검색결과 107건 처리시간 0.027초

An Efficient Design Technique for the Flattened Transfer Function of Arrayed Waveguide Grating

  • Jung Jae-Hoon;Moon Hyung-Myung;Kwak Seung-Chan
    • Journal of the Optical Society of Korea
    • /
    • 제10권1호
    • /
    • pp.33-36
    • /
    • 2006
  • This paper describes an efficient optimal design method for an arrayed waveguide grating (AWG) with flattened transfer function. The objective function is the norm of the difference between calculated and target spectra. To analyze the AWG transfer function, the Fresnel-Kirchhof diffraction formula was employed and the design variable was optical path difference of each array waveguide. The (1+1) Evolution Strategy was applied to an eight-channel coarse wavelength division multiplexing (CWDM) AWG as the optimization tool. The optimized transfer function will considerably improve the system performance.

Closed-Loop Transmit Diversity Techniques for Small Wireless Terminals and Their Performance Assessment in a Flat Fading Channel

  • Mostafa, Raqibul;Pallat, Ramesh C.;Ringel, Uwe;Tikku, Ashok A.;Reed, Jeffrey H.
    • ETRI Journal
    • /
    • 제34권3호
    • /
    • pp.319-329
    • /
    • 2012
  • Closed-loop transmit diversity is considered an important technique for improving the link budget in the third generation and future wireless communication standards. This paper proposes several transmit diversity algorithms suitable for small wireless terminals and presents performance assessment in terms of average signal-to-noise ratio (SNR) and outage improvement, convergence, and complexity of operations. The algorithms presented herein are verified using data from measured indoor channels with variable antenna spacing and the results explained using measured radiation patterns for a two-element array. It is shown that for a two-element array, the best among the proposed techniques provides SNR improvement of about 3 dB in a tightly spaced array (inter-element spacing of 0.1 wavelength at 2 GHz) typical of small wireless devices. Additionally, these techniques are shown to perform significantly better than a single antenna device in an indoor channel considering realistic values of latency and propagation errors.

Efficient Message Scheduling for WDM Optical Networks with Minimizing Flow Time

  • Huang, Xiaohong;Ma, Maode
    • Journal of Communications and Networks
    • /
    • 제6권2호
    • /
    • pp.147-155
    • /
    • 2004
  • In this paper, we propose an efficient sequencing technique, namely minimum Row time scheduling (MFTS), to manage variable-Iength message transmissions for single-hop passive starcoupled WDM optical networks. By considering not only the message length but also the state of the receivers and the tuning latency, the proposed protocol can reduce the average delay of the network greatly. This paper also introduces a new channel assignment technique latency minimizing scheduling (LMS), which aims to reduce the scheduling latency. We evaluate the proposed algorithm, using extensive discrete-event simulations, by comparing its performance with shortest job first (SJF) algorithm. We find that significant improvement in average delay could be achieved by MFTS algorithm. By combining the proposed message sequencing technique with the channel selection technique, the performance of the optical network could be further improved.

망점면적비율에 대한 색인쇄물의 측색학적 해석과 Munsell 표색계와 관계 (Colorimetric Analysis and Matching the Notation of the Munsell System for Reproduced Colors with Variable Dot Area Rates)

  • 이상남
    • 한국인쇄학회지
    • /
    • 제1권1호
    • /
    • pp.7-41
    • /
    • 1983
  • Reproduced colors which are half-tone printed at the rate of 10,20,30, ...100% half-tone dot area by each process ink- cyan, magenta, yellow and at the rates of 0,30,60, 100% half-tone dot areas by the mean color mixing of black, cyan, magenta and yellow, are colorimetric analyzed by make use of the 1931 CIE XYZ system of color specification and matching the Munsell color system. Espacially, magenta and secondary colors which are contained magenta, do not have good uniformity and proportionalization in the dominant wavelength and the excitation purity. Half-tone colors without reflection of blue light, are reproduced ideal color with the excitation purity 100% in wavelengths from 555nm to 600nm.

  • PDF

DWDM 채널 레벨 컨트롤러 설계 및 구현 (DWDM Channel Level Controller Design and Implementation)

  • 염진수;이규정;허창우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2004년도 춘계종합학술대회
    • /
    • pp.655-657
    • /
    • 2004
  • 채널 레벨 컨트롤러는 DWDM(Dense Wavelength Division Multiplexing) 방식의 OXC(Optical Cross Connect), OADM(Optical Add/Drop Multiplexer), 광 증폭기(EDFA : Erbium Doped Fiber Amplifier) 둥의 시스템에서 채널별 광신호의 세기를 조절하여 시스템의 신뢰성을 높이는 중요한 제어기다. 본 논문에서는 12채널 VOA(Variable Optical Attenuator) 4개를 사용하여 40채널의 광 신호 레벨을 제어할 수 있는 컨트롤러를 구현하였다. 각 채널의 광 신호 레벨을 제어하는데 하나의 마이크로 프로세서가 5개의 채널을 제어하고 총 8개의 마이크로프로세서로 40채널을 분산 제어하도록 구성하였다. 또한 외부와 통신을 하고 사용자로부터의 명령을 각각의 마이크로프로세서에 전달하기 위한 마이크로프로세서를 추가하였으며, 출력되는 광 신호의 세기를 측정하여 VOA를 제어하는데 있어서 VOA 출력에서 바로 PD(Photo Detector)로 입력하여 AWC(Arrayed Waveguide Grating) 출력에서 광 신호를 다시 분파하여 PD에 입력하는 번거로움을 개선하였다.

  • PDF

혈액중 non-invasive hematocrit 분석 (Non-invasive hematocrit measurement)

  • Yoon, Gil-Won;Jeon, Kye-Jin;Park, Kun-Kook;Lee, Jong-Youn;Hwang, Hyun-Tae;Yeo, Hyung-Seok;Kim, Hong-Sig
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2002년도 강연요지집
    • /
    • pp.59-62
    • /
    • 2002
  • Wavelength selection and prediction algorithm for determining hematocrit are investigated. A model based on the difference in optical density induced by the pulsation of heart beat is developed by taking approximation of Twersky's theory on the assumption that the variation of blood vessel size is small during arterial pulsing[1]. A device is constructed with a five-wavelength LED array as light source. The selected wavelengths are two isobestic points and three in compensation for tissue scattering. Data are collected from 549 out-patients who are randomly grouped as calibration and prediction sets. The range of percent hematocrit was 19.3∼51.8. The ratio of the variations of optical density between systole and diastole at two different wavelengths is used as a variable. We selected several such variables that show high reproducibility among all variables. Multiple linear regression analysis is made. The relative percent error is 8% and the standard deviation is 3.67 for the calibration set. The relative % error and standard deviation of the prediction set are 8.2% and 3.69 respectively. We successfully demonstrate the possibility of non-invasive hematocrit measurement, particularly, using the wavelengths below 1000nm.

  • PDF

회절격자 주기의 랜덤 변이가 DFB 레이저 특성에 미치는 영향 (Effects of the Random Fluctuation in Grating Period on the Characteristics of DFB Lasers)

  • 한재웅;김상배
    • 대한전자공학회논문지SD
    • /
    • 제37권8호
    • /
    • pp.76-85
    • /
    • 2000
  • 회절격자 주기의 랜덤 변이가 DFB 레이저의 특성에 미치는 영향을 유효 굴절률 전달 매트릭스 방법을 이용하여 해석하였다. 레이저의 양 거울면은 완전 무반사 처리되었다고 가정하였으며, 회절격자 주기의 변이는 Gaussian 랜덤 변수로 표현하였다. 회절격자 주기의 랜덤 변이는 균일 회절격자 DFB 레이저와 QWS-DFB 레이저 스펙트럼의 대칭성을 깨뜨리고 유효 결합계수를 감소시킨다. 이에 따라 균일 회절격자 DFB 레이저에서는 ${\pm}$1모드 거울면 손실의 평균값이 증가하고 금지 대역폭이 감소하며, QWS-DFB 레이저에서는 단일모드 안정성과 파장 정확도가 저하된다. QWS-DFB 레이저의 거울면 손실 차이는 결합계수에 관계없이 회절격자 주기의 랜덤 변이가 카짐에 따라 감소하고, spatial hole-burning 효과는 정규화된 결합계수가 1.5보다 클 때에는 주는 데 반하여 작을 때에는 커진다.

  • PDF

기계학습모형을 이용한 다분광 위성 영상 기반 낙동강 부유 물질 농도 계측 기법 개발 (Development of suspended solid concentration measurement technique based on multi-spectral satellite imagery in Nakdong River using machine learning model)

  • 권시윤;서일원;백동해
    • 한국수자원학회논문집
    • /
    • 제54권2호
    • /
    • pp.121-133
    • /
    • 2021
  • 하천에서 발생하는 부유 물질은 주로 유역으로부터 유입되거나 하천 내에서 자생으로 발생하기도 하며, 퇴적되어 중장기적인 수질 오염을 초래할 수도 있는 중요한 수질 인자이다. 하지만, 부유물질의 재래식 계측방식은 점 단위 계측이기 때문에 노동 집약적이며 방대한 양의 자료를 취득하기는 어렵다. 따라서, 본 연구에서는 고해상도 다분광 위성영상을 제공하는 Sentinel-2 위성 자료를 이용하여 낙동강 전역에 대한 원격탐사 기반 부유 물질 농도 계측 기법을 개발하였다. 개발된 기법은 기존 원격탐사 기반 회귀식들의 한계점을 개선하고 낙동강 전체 영역의 지역적 특성을 반영하기 위해 기계학습 모형인 서포트 벡터 회귀(Support Vector Regression, SVR) 모형을 이용하여 다양한 파장대의 분광 밴드들과 밴드비(band ratios)를 고려하였으며, 이를 입력 변수들의 최적 조합으로 재귀적 특징 제거법(Recursive Feature Elimination, RFE)과 SVR의 각 변수별 가중계수를 활용하여 도출하였다. 가장 중요도가 높은 분광 밴드로는 Red-edge 파장대 영역에 속하는 705 nm 밴드가 산출되었으며, 최종적으로 구축된 SVR 모형을 선행 연구들에서 제시한 회귀식들과 비교한 결과, 가장 정확한 계측 결과를 제공하는 것으로 밝혀졌다. 본 연구에서 개발된 SVR 모형은 RFE를 통해 산출된 최적 분광 밴드 조합을 바탕으로 하기 때문에 기존 단일 분광 밴드 혹은 밴드비를 기반으로 구축된 회귀식들이 가지는 변수 의존도를 낮추는 동시에 더욱 정확한 부유물질 농도 공간분포를 제공할 수 있을 것으로 판단된다.

근거리 작업 시 종색수차에 따른 양안시의 변화 (Change of Binocular Vision Induced by Longitudinal Chromatic Aberration during Near Work)

  • 김세일;박미정;김소라
    • 한국안광학회지
    • /
    • 제20권2호
    • /
    • pp.219-228
    • /
    • 2015
  • 목적: 본 연구에서는 근업 시 바탕색의 차이에 따른 시기능의 차이를 비교하고자 하였다. 방법: 본 연구에 동의하며 안질환 및 안과적 수술경험이 없고 사시, 약시가 없는 양안시가 가능한 성인 54명(남18, 여34)을 대상으로 흰색, 적색, 녹색 및 청색의 바탕에 검은색 글씨로 구성된 소설을 각각 15분 동안 읽게 한 후 사위도, AC/A비, 폭주근점, 조절용이성, 상대조절 및 융합력을 측정한 후 근거리 작업 전후 차이를 비교하였다. 결과: 사위도는 바탕색에 관계없이 독서 전과 비교하여 전체적으로 감소하는 경향을 나타내었으며, AC/A비는 백색 바탕색을 제외한 다른 바탕색의 책을 읽은 후에는 증가하는 경향을 나타내었다. 폭주근점은 바탕색별로 모두 독서 전과 비교하여 유의한 증가를 보였다. 우위안 및 비우위안의 조절용이성은 독서 후 모두 유의한 증가를 나타내었지만 양안조절용이성의 경우는 감소하는 경향을 나타내었다. 음성상대조절은 모든 바탕색에서 유의한 감소를 보였으나 양성상대조절의 변화는 유의하지 않았다. 융합력의 경우 바탕색의 각 파장별 원거리 BO 분리점과 원거리 BO 회복점에서 유의한 변화를 나타내었다. 결론: 본 연구를 통하여 일정시간의 근업 시 동일한 조절과 폭주량이 요구됨에도 불구하고 빛의 파장에 따라 폭주의 변화가 나타남을 알 수 있었으므로 다양한 색채인지를 요구하는 근거리 작업 시에는 주가 되는 파장에 따라 작업환경의 조정이 이루어져야 함을 제안할 수 있다.

광역학적 암치료를 위한 635nm 다이오드 레이저 시스템 개발 (The Development of 63nm Diode Laser System for Photodynamic Therapy of Cancer)

  • 임현수
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권4호
    • /
    • pp.319-328
    • /
    • 2003
  • 본 논문은 광역학적 암치료를 위한 광원장치의 개발로서 반도체 다이오드 레이저를 이용한 의료용 레이저 시스템의 개발이 목적이다. 광역학적 암 치료에서 이상적인 광원장치는 초점크기를 조절할 수 있으면서 발산하지 않는 균일한 빛과 특정 파장대의 안정성을 갖는 것이다. 본 연구에서는 이러한 점을 고려하여 635nm 파장대의 다이오드 공진기를 이용하였으며, 개발된 레이저 시스템은 제어장치를 사용하여 정교하고 안정적인 출력을 가지도록 하였으며, 시스템은 사용자의 편리성을 고려하여 소형화하였다. 다이오드 레이저시스템의 펄스 형태의 발진모드에서는 초기의 돌입전류에 의해 공진기를 파손시킬 수 있으므로 본 연구에서는 이러한 현상을 회로적으로 보완하여 msec 단위로 on/off 할 경우에도 공진기에 전혀 손상을 입히지 않도록 설계를 하였다. 임상의가 편리하게 방사시간을 설정하고, 연속출력. 펄스. 버스트 펄스, 슈퍼펄스를 방사할 수 있도록 고안하여. 다양한 암조직의 상태에 따라 치료할 수 있도록 구현하였다. 실험결과 레이저의 출력은 입력전류와 시간에 따라 10mW에서 300mW 까지 선형적으로 증가함을 보였다. 개발된 광역학적 레이저 시스템은 고속제어가 가능하고 정 전류 제어와 효과적인 냉각 제어를 통해 안정적으로 정확하게 출력할 수 있었다.