• 제목/요약/키워드: Variable speed generator

검색결과 184건 처리시간 0.03초

저속 기어형 2MW급 풍력발전기 개념설계 (Conceptual Design of 2MW Wind Turbine Generator with Low-speed Gearbox)

  • 손영욱;김영찬;김용환;이응채;박인수;정진화;한경섭;전중환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.319-322
    • /
    • 2006
  • Under the national project for the development of 2MW wind energy convert system, we are under development of the prototype of 2MW wind turbine with low speed gearbox. This system adopts low speed gear box with planetary and spur gear and is pitch regulated variable speed type with the synchronous permanent magnet generator. The compromised size of generator in diameter and width are adopted to meet the structural design requirements. In this paper, the concept study for the type, the aerodynamic design for the blade and the details of load calculation will be presented. The detailed characteristics of the system will also be introduced.

  • PDF

Static VAR Compensator-Based Voltage Regulation for Variable-Speed Prime Mover Coupled Single- Phase Self-Excited Induction Generator

  • Ahmed, Tarek;Noro, Osamu;Sato, Shinji;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제3권3호
    • /
    • pp.185-196
    • /
    • 2003
  • In this paper, the single-phase static VAR compensator (SVC) is applied to regulate and stabilize the generated terminal voltage of the single-phase self-excited induction generator (single-phase SEIG) driven by a variable-speed prime mover (VSPM) under the conditions of the independent inductive load variations and the prime mover speed changes The conventional fixed gain PI controller-based feedback control scheme is employed to adjust the equivalent capacitance of the single-phase SVC composed of the fixed excitation capacitor FC in parallel with the thyristor switched capacitor TSC and the thyristor controlled reactor TCR The feedback closed-loop terminal voltage responses in the single-phase SEIG coupled by a VSPM with different inductive passive load disturbances using the single-phase SVC with the PI controller are considered and discussed herem. A VSPM coupled the single-phase SEIG prototype setup is established. Its experimental results are illustrated as compared with its simulation ones and give good agreements with the digital simulation results for the single-phase SEIG driven by a VSPM, which is based on the SVC voltage regulation feedback control scheme.

연간 최대 에너지 생산량을 위한 직접구동 영구자석 풍력 발전기의 최적설계 (Optimal Design of Direct-driven PM Wind Generator for Maximum Annual Energy Production)

  • 조명수;이철균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.3-5
    • /
    • 2006
  • In this paper, annual energy production(AEP) of the wind generator system is analogized considering the regions of a variable wind speed and it is applied to optimal design of the PM wind generator for capturing maximum energy in the operating regions. In addition, internet parallel computing is used to loose excessive calculation times through optimization of the finite element analysis(FEA).

  • PDF

Mechatronic Control Model of the Wind Turbine with Transmission to Split Power

  • Zhang Tong;Li Wenyong;Du Yu
    • International Journal of Control, Automation, and Systems
    • /
    • 제3권4호
    • /
    • pp.533-541
    • /
    • 2005
  • In this paper, a wind turbine with power splitting transmission, which is realized through a novel three-shaft planetary, is presented. The input shaft of the transmission is driven by the rotor of the wind turbine, the output shaft is connected to the grid via the main generator (asynchronous generator), and the third shaft is driven by a control motor with variable speed. The dynamic models of the sub systems of this wind turbine, e.g. the rotor aerodynamics, the drive train dynamics and the power generation unit dynamics, were given and linearized at an operating point. These sub models were integrated in a multidisciplinary dynamic model, which is suitable for control syntheses to optimize the utilization of wind energy and to reduce the excessive dynamic loads. The important dynamic behaviours were investigated and a wind turbine with a soft main shaft was recommend.

풍력발전 제어에 적용되는 계측신호처리 필터에 대한 특성 고찰 (Characteristics of Filters for Signal Processing Applied to Wind Turbine Controllers)

  • 문석준;신윤호;정태영;임채환;류지윤
    • 신재생에너지
    • /
    • 제7권4호
    • /
    • pp.58-65
    • /
    • 2011
  • In variable-speed variable-pitch wind turbines, the conventional approach for controlling power-production operation relies on a generator-torque controller and a rotor-collective blade-pitch controller. Both controllers use the generator speed measurement as the sole feedback input. In order to mitigate unwanted excitation of the control system, many filters are adopted. In this study, the characteristics of some filters for signal processing are investigated based on frequency response function. They include low-pass filters, band-pass filters, and notch filters. Especially, this study focuses on design parameters of their filters.

Flicker Suppression Scheme for Variable-Speed Wind Turbine Systems

  • Van, Tan Luong;Nguyen, Thanh Hai;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제12권2호
    • /
    • pp.333-343
    • /
    • 2012
  • This paper proposes a strategy of flicker mitigation for doubly-fed induction generator (DFIG) wind turbine systems. In the weak grid system where the grid impedance ratio is low, the reactive power compensation only cannot suppress the flicker sufficiently due to the limited power capacity of the converters or the DFIG. For the full suppression of flickers, the active power smoothening using the energy storage system (ESS) needs to be utilized together with the reactive power compensation. The effectiveness of the proposed method is verified by PSCAD/EMTDC simulation results for a 2[MW] DFIG wind turbine system and by experimental results for a 3[kW] wind turbine simulator.

가변관성 모의 기능을 가진 풍력발전기 시뮬레이터의 제어 알고리즘 (Control Algorithm for Wind Turbine Simulator with Variable Inertia Emulation)

  • 정병창;정세종;송승호;노도환;김동용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.170-173
    • /
    • 2002
  • A variable speed wind turbine simulator is designed and implemented for the simulation of wind power generation system. The control algorithm decides the shaft torque delivered to generator taking into consideration the wind speed, the generator rpm, and the rotor blade inertia. It is shown that the proposed control algorithm can emulate the dynamic behavior of actual wind turbine through simulations and experimental.

  • PDF

풍력발전 제어에 적용되는 계측신호처리 필터에 대한 특성 고찰 (Characteristics of Filters for Signal Processing Applied to Wind Turbine Controllers)

  • 문석준;신윤호;정태영;임채환;류지윤
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.36.2-36.2
    • /
    • 2011
  • In variable-speed variable-pitch wind turbines, the conventional approach for controlling power-production operation relies on a generator-torque controller and a rotor-collective blade-pitch controller. Both controllers use the generator speed measurement as the sole feedback input. In order to mitigate unwanted excitation of the control system, many filters are adopted. In this study, the characteristics of some filters for signal processing are investigated based on frequency response function. They include low-pass filters, band-pass filters, and notch filters. Especially, this study focuses on design parameters of their filters.

  • PDF

Augmentation of Wind Farms Ride Through by DFIG-based Variable Speed Wind Generators

  • Okedu, K.E.;Muyeen, S.M.;Takahashi, R.;Tamura, J.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권1호
    • /
    • pp.104-113
    • /
    • 2012
  • Wind farm grid codes require wind generators to ride through voltage sags, which means that normal power production should be re-initiated once the nominal grid voltage has been recovered. Doubly Fed Induction Generator (DFIG) based wind farm is gaining popularity these days because of its inherent advantages like variable speed operation and independent controllability of active and reactive power over conventional Induction Generator (IG). This paper proposes a new control strategy using DFIGs for stabilizing a wind farm composed of DFIGs and IGs. Simulation analysis by using PSCAD/EMTDC shows that the DFIGs can effectively stabilize the IGs and hence the entire wind farm through the proposed control scheme by providing sufficient reactive power to the system.

실 계통 연계 1.5MW급 DFIG 풍력발전 시뮬레이터의 응동특성 분석 (Analysis of Dynamic Response of 1.5MW DFIG Wind Power Simulator with Real-grid Connection)

  • 최영도;전영수;전동훈;신정훈;김태균;정병창
    • 신재생에너지
    • /
    • 제5권3호
    • /
    • pp.4-12
    • /
    • 2009
  • The effect of change in DFIG (doubly-fed wind power generator) rotating speed and active power on the grid was analyzed to understand the characteristics of wind power using the wind power simulator connected to the grid at Gochang Power Quality Test Center. Electric power quality improvement devices (DVR, STATCOM, SSTS) and electric power quality disturbance application devices for 22.9 kV grid are equipped at Gochang Power Quality Test Center. Induction motor and VVVF inverter were used to emulate the blade of a wind power generator, and a simulator for Cage wound induction generator and DFIG was developed. The trial line were assumed to be 20 km and 40 km in length, and variable wind speed pattern was set using wind speed data from Ducjeokdo to verify the power characteristics of the wind power generator according to rotating speed.

  • PDF