• Title/Summary/Keyword: Variable speed control

Search Result 901, Processing Time 0.029 seconds

3MW Class Offshore Wind Turbine Development (3MW급 해상풍력 발전시스템 개발)

  • Joo, Wan-Don;Lee, Jeong-Hoon;Kim, Jeong-Il;Jeong, Seok-Yong;Shin, Young-Ho;Park, Jong-Po
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.491-494
    • /
    • 2009
  • This paper introduces the design concepts and characteristics of WinDS3000$^{TM}$ which is a trade mark of Doosan's 3MW offshore/onshore wind turbine. WinDS3000$^{TM}$ has been designed in consideration of high RAMS (Reliability, Availability, Maintainability and Serviceability) and cost effectiveness for the TC Ia condition in GL guideline. An integrated drive train design with an innovative three-stage gearbox has been introduced to minimize nacelle weight of the wind turbine and to enhance a high reliability for transmission. A permanent magnet generator with full converter system has been introduced to get higher efficiency in part load operation, and grid friendliness use of 50 Hz and 60 Hz grid. A pitch regulated variable speed power control with individual pitch system has been introduced to regulate rotor torque while generator reaction torque can be adjusted almost instantaneously by the associated power electronics. An individual pitch control system has been introduced to reduce fatigue loads of blade and system. The wind turbine has been also equipped with condition monitoring and diagnostic systems in order to meet maintainability requirements. And internal maintenance crane in nacelle has been developed. As a result, the maintenance cost was dramatically reduced and maintenance convenience also enhanced in offshore condition.

  • PDF

Optimal Aerodynamic Design and Performance Analysis for Pitch-Controlled HAWT (가변 피치형 수평축 풍력 터빈의 공력 최적설계 및 피치제어 성능 연구)

  • Ryu, Ki-Wahn
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.10
    • /
    • pp.891-898
    • /
    • 2007
  • Optimal aerodynamic design for the pitch-controlled horizontal axis wind turbine and its aerodynamic performance for various pitch angles are performed numerically by using the blade element momentum theory. The numerical calculation includes effects such as Prandtl‘s tip loss, airfoil distribution, and wake rotation. Six different airfoils are distributed along the blade span, and the special airfoil i.e. airfoil of 40% thickness ratio is adopted at the hub side to have structural integrity. The nonlinear chord obtained from the optimal design procedure is linearized to decrease the weight and to increase the productivity with very little change of the aerodynamic performance. From the comparisons of the power, thrust, and torque coefficients with corresponding values of different pitch angles, the aerodynamic performance shows delicate changes for just $3^{\circ}$ increase or decrease of the pitch angle. For precisive pitch control, it requires the pitch control algorithm and its drive mechanism below $3^{\circ}$ increment of pitch angle. The maximum torque is generated when the speed ratio is smaller than the designed one.

Single-Phase Self-Excited Induction Generator with Static VAR Compensator Voltage Regulation for Simple and Low Cost Stand-Alone Renewable Energy Utilizations Part II : Simulation and Experimental Results

  • Ahmed, Tarek;Noro, Osamu;Soshin, Koji;Sato, Shinji;Hiraki, Eiji;Nakaoka, Mutsuo
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.1
    • /
    • pp.27-34
    • /
    • 2003
  • In this paper, the power conditioner composed of the stand-alone single-phase squirrel cage rotor type self-excited induction generator (SEIG) driven by prime movers such as a wind turbine and a micro gas turbine (MGT) is presented by using the steady-state circuit analysis based on the two nodal admittance approaches using the per-unit frequency in addition to a new state variable defined by the per-unit slip frequency along with its performance evaluations for the stand-alone energy utilizations. The stande-alone single-phase SEIG operating performances in unregulated voltage control loop are then evaluated on line under the conditions of the speed change transients of the prime mover and the stand-alone electrical passive load power variations with the simple theoretical analysis and the efficient computation processing procedures described in the part I of this paper. In addition, a feasuible PI controlled feedback closed-loop voltage regulation scheme of the stande-alone single-phase SEIG is designed on the basis of the static VAR compensate. (SVC) and discussed in experiment for the promising stand-alone power conditioner. The experimental operating performance results are illustrated and give good agreements with the simulation ones. The simulation and experimental results of the stand-alone single-phase SEIG with the simple SVC controller for its stabilized voltage regulation prove the practical effectiveness of the additional SVC control loop scheme including the PI controller with fast response characteristics and steady-sate performance improvements.

Design of DC Level Shifter for Daisy Chain Interface (Daisy Chain Interface를 위한 DC Level Shifter 설계)

  • Yeo, Sung-Dae;Cho, Tae-Il;Cho, Seung-Il;Kim, Seong-Kweon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.5
    • /
    • pp.479-484
    • /
    • 2016
  • In this paper, a design of DC level shifter transmitting and receiving control and data signal which have various DC level through daisy chain interface between master IC and slave is introduced in the cell voltage monitoring (CVM). Circuit designed with a latch structure have a function to operate in high speed and for output of variable DC level through transmission gate. As a result of the simulation and the measurement, it was confirmed that control and data signal could be transferred according to the change of DC level from 0V to 30V. Delay time was measured about 170ns. but, it was considered as a negligible tolerance due to a parasitic capacitance of measuring probe and test board.

A Study on Land Warrior System Design Based on IEEE 802.15.4 (IEEE 802.15.4 기반의 미래병사체계 시스템 설계에 관한 연구)

  • Heo, Jun;Lee, Sang-Jin;Choi, Yong-Hoon;Choi, Hyo-Hyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.5
    • /
    • pp.71-80
    • /
    • 2012
  • In this paper, applications that require low-speed data rate on personal area network to operate the Land Warrior system is proposed. These applications can refer to WSN(wireless sensor network) technology. However, this technology is not suitable to support various data transmission rate. A suitable CSMA/CA algorithm for Land Warrior System in order to solve these existing system problems is proposed. The proposed algorithm is designed to be variable CSMA/CA algorithm parameter, depending on data rate. For the evaluation of Land Warrior system model and CSMA/CA algorithm, we used Castalia. As a result of the simulation, it is found that the proposed system model can not only relieve loads of data processing, but also probability of collision was decreased.

A Study of Relative Feeder-Cable Length and Vehicle Detection Length of Loop Detector (루프검지기의 휘더선길이와 차량검지길이의 관계 연구)

  • Oh, Young-Tae;Kim, Nam-Sun;Kim, Soo-Hee;Song, Ki-Hyuk
    • Journal of Korean Society of Transportation
    • /
    • v.22 no.3 s.74
    • /
    • pp.85-94
    • /
    • 2004
  • Loop detection systems have been used in real-time signal control system to collect traffic information for estimating queue lengths. The queue length algorithm uses speed as a key variable estimated from occupancy time and average vehicle length. The measurement of average vehicle length is affected from the lengths of feeder cable, but their effects have not yet been evaluated. In this study, the variability of average vehicle length due to the lengths of feeder cable is assessed through a field study, and a practical guidelines is proposed. By applying this result, the operational performance of real-time signal control system could be improved.

Design of a Transformable Spherical Robot Based on Multi-Linkage Structure (복합 링크 구조 기반의 가변형 구형로봇 설계)

  • Kang, Hyeongseok;Joe, Seonggun;Lee, Dongkyu;Kim, Byungkyu
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.6
    • /
    • pp.26-33
    • /
    • 2017
  • We propose a variable frame structure connected with telescopic mast-shaped shaft for a robot displaying outstanding ability to cross obstacles, and for effective traction control. The wireless control system was built to extend and contract a deployable mechanism, which is shaped into a hoberman sphere assembled with frame structures. In order to develop important parameters for efficient locomotion, we derived an Euler-Lagrange equation for the spherical robot. According to the equation, the DC motor was selected. A prototype mechanism was tested and a Finite-Element Analysis (FEA) was conducted in parallel. Using these data, we constructed a deployable spherical robot with structural stability. The deployable robot moved at a speed of 0.85 m/s from 520 mm to 650 mm.

A Study on the Ship Channel Design Method using Variable Bumper Area Model (I) (가변범퍼영역모델을 이용한 항로설계기법(I))

  • Jeong Dae-Deug;Lee Joong-Woo
    • Journal of Navigation and Port Research
    • /
    • v.29 no.1 s.97
    • /
    • pp.9-15
    • /
    • 2005
  • To design ship channel is one of important factors for planning and developing a port. In most case, the core factors for designing ship channel are the layout and width of channel provided the net underkeel clearance is secured to be safe enough to pass. In this study, Variable Bumper Area(VBA) model is applied to design and assess ship channel. This model reflects ship's particular, ship domain theory, ship speed and mariner's ship handling skill and experience, especially external forces which cause leeway, set and drift and the change of ship maneuvering characteristics. A real time, full mission shiphandling simulator is used to analyze ship dynamic data according to mariner's ship control, external forces, ete. This model defines Domain degree and Domain-index for assessing the efficiency and safety of the channel. The proposed model is applied to Ulsan new port plan which has a channel width of 1.5 times the length of the largest vessel, a radius of 5 times the length of the largest vessel in a curve of 57 degree centerline angle and SBM facility adjacent to the lateral edge of channel. The result of this study shows that the width of the channel and radius of channel curve are suitable for the target ship but the difficulty of ship handling is caused by the large course change and SBM located in the vicinity of channel.

Mode Control Design of Dual Buck Converter Using Variable Frequency to Voltage Converter (주파수 전압 변환을 이용한 듀얼 모드 벅 변환기 모드 제어 설계)

  • Lee, Tae-Heon;Kim, Jong-Gu;So, Jin-Woo;Yoon, Kwang-Sub
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.4
    • /
    • pp.864-870
    • /
    • 2017
  • This paper describes a Dual Buck Converter with mode control using variable Frequency to Voltage for portable devices requiring wide load current. The inherent problems of PLL compensation and efficiency degradation in light load current that the conventional hysteretic buck converter has faced have been resolved by using the proposed Dual buck converter which include improved PFM Mode not to require compensation. The proposed mode controller can also improve the difficulty of detecting the load change of the mode controller, which is the main circuit of the conventional dual mode buck converter, and the slow mode switching speed. the proposed mode controller has mode switching time of at least 1.5us. The proposed DC-DC buck converter was implemented by using $0.18{\mu}m$ CMOS process and die size was $1.38mm{\times}1.37mm$. The post simulation results with inductor and capacitor including parasitic elements showed that the proposed circuit received the input of 2.7~3.3V and generated output of 1.2V with the output ripple voltage had the PFM mode of 65mV and 16mV at the fixed switching frequency of 2MHz in hysteretic mode under load currents of 1~500mA. The maximum efficiency of the proposed dual-mode buck converter is 95% at 80mA and is more than 85% efficient under load currents of 1~500mA.

Countermeasures to the Introduction of Low Caloric Gas Fuel for Natural Gas Engine (저열량 가스 적용에 따른 천연가스엔진의 대응 방안 연구)

  • Park, Cheol-Woong;Kim, Chang-gi;Oh, Se-Chul;Lee, Jang-Hee
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.2
    • /
    • pp.34-41
    • /
    • 2021
  • In order to cope with the problems that may occur when the natural gas used in Korea becomes low in calories, the problems that may have to the domestic industrial gas equipment must be identified in advance, and based on this, countermeasures for efficient use of energy must be preceded. In this study, in order to solve the problem of deterioration of engine output performance and efficiency due to the introduction of low calorific gas when using a lean-burning natural gas engine that complies with the EURO-6 regulation, specific control plans and results based on the experiment are intended to be presented. In order to identify the improvement effect by the control variable represented by the ignition timing under the full load condition at the engine speed of 1,400 rpm and 550 Nm, 2,100 rpm, which is the engine speed at the rated operation condition, the thermal efficiency and exhaust gas characteristics were identified and optimized by changing the ignition timing for each gas fuel. In the case of pure methane, which shows the lowest value based on the torque under the full load condition, if the ignition timing is advanced by about 2 CAD from the reference ignition timing, the torque can be compensated without a large increase in NOx emission.