• Title/Summary/Keyword: Variable controls

Search Result 222, Processing Time 0.033 seconds

Design of Variable Speed SRM Drive for Hydraulic Pump Application (유압펌프용 가변속 SRM 구동시스템 설계)

  • Lee, Dong-Hee;Kim, Bong-Chul;An, Young-Joo;Ahn, Jin-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • This paper proposes an SRM drive system to improve the drive efficiency of the hydraulic system. From the maximum hydraulic pressure and flow rate required by the hydraulic system, a proper SRM is designed and tested. The proposed SRM drive system controls oil pressure of the hydraulic system as well as motor speed. A 2.2[kW], 12/8-pole SR motor and digital controller based DSP are designed and tested for hydraulic pump system. The test results show that the system has some good features such as high efficiency and rapid response characteristics.

Linearizing and Control of a Three-phase Photovoltaic System with Feedback Method and Intelligent Control in State-Space

  • Louzazni, Mohamed;Aroudam, Elhassan
    • Transactions on Electrical and Electronic Materials
    • /
    • v.15 no.6
    • /
    • pp.297-304
    • /
    • 2014
  • Due to the nonlinearity and complexity of the three-phase photovoltaic inverter, we propose an intelligent control based on fuzzy logic and the classical proportional-integral-derivative. The feedback linearization method is applied to cancel the nonlinearities, and transform the dynamic system into a simple and linear subsystem. The system is transformed from abc frame to dq0 synchronous frame, to simplify the state feedback linearization law, and make the close-loop dynamics in the equivalent linear model. The controls improve the dynamic response, efficiency and stability of the three-phase photovoltaic grid system, under variable temperature, solar intensity, and load. The intelligent control of the nonlinear characteristic of the photovoltaic automatically varies the coefficients $K_p$, $K_i$, and $K_d$ under variable temperature and irradiation, and eliminates the oscillation. The simulation results show the advantages of the proposed intelligent control in terms of the correctness, stability, and maintenance of its response, which from many aspects is better than that of the PID controller.

VAV Air Conditioning Research for Ship HVAC Efficiency (선박 HVAC 효율 증가를 위한 변풍량 방식 공기조화 연구)

  • Kang, Young-Min;Kim, Min-Wook;Jang, Jae-Hee;Kim, Hui-Mang;Oh, Jeon-Seok
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2016.05a
    • /
    • pp.93-95
    • /
    • 2016
  • In recent years, attention of ship owners for the energy saving of the vessel is being collected due to the volume decline. Ship accommodation consists of watertight type windows and is closed, Ship HVAC is used to promote a comfortable environment for the crew. In addition requirements for comfort of the crew is getting stronger with the improvement of living standards, there is a need for HVAC improvements. In this paper, propose method to save energy and improve HVAC controls by using the HVAC structure of the variable air volume.

  • PDF

Event Based Tele-Operation with Variable Holding Time (가변 지속시간을 갖는 이벤트 기반 원격제어)

  • 박준영;박장현
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.12
    • /
    • pp.70-77
    • /
    • 2002
  • Necessity of the tole-operation has been increased in many fields. Since the Internet is inexpensive and available all over the world, it is a strong candidate for the transmission media of the tole-operation. However, the Internet has random time delays that may cause instability in the system especially if the tole -operation is bilateral. In the past few years many attempts have been made to overcome the random time delay, So far, they are still insufficient in terms of performance. The ‘Variable holding time’ is introduced to improve the performance of the ‘Event based tole-operation’ which controls a system with a non-time action reference. By holding each event for proper time, the system can quickly respond and be stabilized. The proper holding time should be selected based on the characteristics of the task that the system performs. The factors that reflect those characteristics are investigated. The fuzzy logic is employed to obtain the proper holding time for each event while the tole-operation system is in operation. The experimental results presented in this paper verify effectiveness of the proposed method.

Optimal Switching Pattern of Voltage Source Inverter (전압원인버어터의 최적스위칭패턴)

  • 정필선;정동화;이윤종
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.12 no.4
    • /
    • pp.386-398
    • /
    • 1987
  • This paper is proposed the Suboptimal PAWM(Pulse Amplitude Width Modulation) for minimize harmonic effects generated by switching operation of PWM Inverter. This strategy determine one switching pattern at a fixed point(fundamental) voltage u1=1.2) which THD(Total Harmonic Distortion) are minimized in the suboptimal PWM strategy, and controls only frequency in the inverter while voltage control is carried out by DC Chopper in the DC Link. This strategy is applied at VSD(Variable Speed Drive) of Three phase induction moter, and acoustic noise of motor, line to line voltage and current of inverter, current harmonic spectrum was estimated and also compared with other switching strategy. From the results, the validity of this strategy can be verified.

  • PDF

Level Controller On Optical Signal of 40 Channel (40 채널 광 신호 레벨 제어기)

  • Yeom Jin-su;Hur Chang-Wu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.2
    • /
    • pp.220-223
    • /
    • 2006
  • In this paper, we studied about the level controller of optical signal with 40 channels by 4 VOA(Variable Optical Attenuator) with 12 channels. Total 8 microprocessors control 40 chamois for control of optical signal level so that a microprocessor controls 5 channels each. Moreover a microprocessor was added to communicate with outside and transfer instruction to each microprocessor. The output optical signal is measured and VOA is controlled as a result of it. The VOA outputs is inputted into PD(Photo Detector) at once. We could control multi-channel optical signals simply like this.

A Study on Manually and Continuously Variable Impact Force Control Device Development for Hydraulic Breakers (유압브레이커의 수동 무단 타격력 제어기구 개발에 대한 연구)

  • Kang, Young Ky;Jang, Ju Seop
    • Journal of Drive and Control
    • /
    • v.17 no.4
    • /
    • pp.46-53
    • /
    • 2020
  • In this paper, the development of a manually and continuously variable impact force control mechanism for hydraulic breakers was studied. Generally, a hydraulic breaker has one or two piston strokes. Hydraulic breakers, which have two strokes, have two valve-switching ports and make short and long piston strokes. The piston stroke valve controls the piston stroke by opening and closing a short stroke-switching port. The short piston stroke mode is used to break soft rock, concrete, or asphalt. This stroke control valve system is not popular for small hydraulic breakers mounted on 1 to 14-ton excavators. To preserve the carrier-like excavator, proper breaking force is needed, and it can be easily controlled by multiple piston stroke control valves. The easiest way to control these breakers is to use several switching ports and valves but they are not easy to install in small hydraulic breakers and are expensive. To use only one switching port and valve, a method can be used to change the open area of the switching port to delay valve switching. This method provides multiple piston strokes.

Core design study of the Wielenga Innovation Static Salt Reactor (WISSR)

  • T. Wielenga;W.S. Yang;I. Khaleb
    • Nuclear Engineering and Technology
    • /
    • v.56 no.3
    • /
    • pp.922-932
    • /
    • 2024
  • This paper presents the design features and preliminary design analysis results of the Wielenga Innovation Static Salt Reactor (WISSR). The WISSR incorporates features that make it both flexible and inherently safe. It is based on innovative technology that controls a nuclear reactor by moving molten salt fuel into or out of the core. The reactor is a low-pressure, fast spectrum transuranic (TRU) burner reactor. Inherent shutdown is achieved by a large negative reactivity feedback of the liquid fuel and by the expansion of fuel out of the core. The core is made of concentric, thin annular fuel chambers containing molten fuel salt. A molten salt coolant passes between the concentric fuel chambers to cool the core. The core has both fixed and variable volume fuel chambers. Pressure, applied by helium gas to fuel reservoirs below the core, pushes fuel out of a reservoir and up into a set of variable volume chambers. A control system monitors the density and temperature of the fuel throughout the core. Using NaCl-(TRU,U)Cl3 fuel and NaCl-KCl-MgCl2 coolant, a road-transportable compact WISSR core design was developed at a power level of 1250 MWt. Preliminary neutronics and thermal-hydraulics analyses demonstrate the technical feasibility of WISSR.

Blood Lead and ZPP Concentrations of Underground Parking Lot Workers (지하주차장 근무자의 혈중 연 및 Zinc Protoporphyrin 농도)

  • Jung, Tae-Heum;Jeon, Man-Joong;Hwang, Tae-Yoon;Kim, Chang-Yoon;Chung, Jong-Hak
    • Journal of Yeungnam Medical Science
    • /
    • v.15 no.2
    • /
    • pp.224-236
    • /
    • 1998
  • A study was conducted to investigate the blood lead and zinc protoporphyrin(ZPP) concentrations of the underground parking lot workers who exposed to vehicular exhaust aerosols which contained lead. The blood samples were collected from 25 study subjects of underground parking lot and from 33 controls in Taegu, from July to October, 1997. And also the related factors to the blood lead and ZPP concentrations were investigated. Blood lead concentration and ZPP concentration were measured by flameless furnace atomic absorption spectrophotometer (1L.551) and hemetofluorometer, respectively. The mean blood lead concentrations of study subjects and controls were $23.10{\pm}20.77{\mu}g/dl$ and $12.99{\pm}12.71{\mu}g/dl$, respectively(p<0.05), and the mean blood ZPP concentrations of study subjects and controls were $40.72{\pm}9.46{\mu}g/dl$ and $38.21{\pm}10.97{\mu}g/dl$, respectively. No significant correlations were observed between the blood lead concentration of the study subjects and their job duration and between blood ZPP concentration of the study subjects and their job duration. There were no statistically significant differences in the blood lead concentration and the blood ZPP concentration of smokers and nonsmokers. In multiple regression analysis on blood lead concentration of the study subjects and controls, occupation was a only significant dependent variable. In case of bood ZPP concentration, age was a only significant dependent variable in the study subjects and controls.

  • PDF

Process Control Analysis for Efficient Production Management of Customized Baseball Uniforms (맞춤형 야구복의 효율적 생산관리를 위한 공정관리 분석)

  • Choi, Kueng-Mi;Hwang, Hyun-Jung;Jun, Jung-Il;Park, Yong-Soo
    • Fashion & Textile Research Journal
    • /
    • v.14 no.4
    • /
    • pp.597-606
    • /
    • 2012
  • To increase the productivity and product quality of customized baseball jerseys, this study developed a multi-variable system for a production process that efficiently controls diverse production management factors. The working time was measured through the establishment of a standard process where skilled workers and Chinese factory workers manufactured 5 sets of the same basic design jerseys. Based on the measured working time (1,136 seconds/per unit), the multi-variable process control system was developed, where hourly production management is possible according to the involved workers and equipment types. Each process was assigned accoding to the production management factors for a total of 28 standard processes. The processes were developed based on consideration of work characteristics according to the order of needlework of open-type set baseball jerseys with sleeves(the basic design of baseball jerseys)to result in a customized production system structure that could be set up with multi-variables. As a result, a total 12 types of systems were developed in consideration of the personnel involved and the number of equipments. The optimal production management system (with the highest efficiency compared to the number of workers)was A-2, B-1, C-1. D-2, E-2, F-1, and G-1. This system had extremely high efficiency and showed 99% assignment efficiency for the 7-person team. Though not optimal, possible process assignment for each working personnel is proposed as a reserve process in case work modification is inevitable due to malfunctions and the absence of equipments.