• Title/Summary/Keyword: Variable Wind Speed

Search Result 272, Processing Time 0.025 seconds

The Relationship between Climatic and Oceanographic Factors and Laver Aquaculture Production (기후 및 해양 요인과 김 생산량과의 관계에 관한 연구)

  • Kim, Do-Hoon
    • The Journal of Fisheries Business Administration
    • /
    • v.44 no.3
    • /
    • pp.77-84
    • /
    • 2013
  • While some steps in laver aquaculture production can be controlled artificially to a certain extent, the culturing process is largely affected by natural factors, such as the characteristics of seawater, climatic and oceanographic conditions, etc. This study aims to find a direct relationship between climatic and oceanographic factors (water temperature, air temperature, salinity, rainfall, sunshine duration and wind speed) and laver aquaculture production in Wando region, the biggest aquaculture production area of laver, located in the southwest coast of Korea using a multiple regression analysis. Despite the small sample size of a dependent variable, the goodness of model fit appeared acceptable. In addition, the R-squared value was 0.951, which means that the variables were very explanatory. Model results indicated that duration of sunshine, temperature, and rainfall during the farming period from the end of September to the end of April would be important factors affecting significantly to the laver aquaculture production.

Simulation Model of Variable Speed Wind Turbine System Using Matrix Converter (매트릭스 컨버터를 이용한 가변속풍력발전시스템 시뮬레이션 모델 연구)

  • Cha, Han-Ju;Kim, Woo-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.224-226
    • /
    • 2008
  • 본 논문에서는 매트릭스 컨버터를 이용하여 풍력을 에너지원으로한 영구자석형 동기 발전기의 계통연계방법을 제안하고 시뮬레이션으로 타당성을 검증한다. 풍속의 변화에 따라 영구자석형 동기발전기 속도가 변하며, 발전기 속도의 변화로 인해 발전전압의 크기와 주파수가 변한다. 이렇게 가변하는 발전 전압과 주파수를 계통전압의 고정된 전압 크기와 주파수로 변환하는 전력변환장치로써 기존의 PWM AC/DC/AC 컨버터 대신에 매트릭스 컨버터를 사용하여 직접적으로 AC-AC 변환을 한다. 매트릭스 컨버터가 가지고 있는, DC 링크단의 대용량 캐패시터가 필요없고; 양방향전력흐름을 제어할 수 있고, 사용자가 원하는 출력전압의 크기, 주파수, 역률을 임의로 제어 할 수 있는 이점을 사용하여 매트릭스 컨버터를 이용한 영구자석형 동기발전기의 계통연계에 대한 시뮬레이션 결과를 소개한다.

  • PDF

A Study on Natural Ventilation Performance for a Double-Skin Facade System in Apartment Buildings (이중외피시스템을 적용한 고층 주거용건물의 자연환기 성능평가)

  • 석호태;김동화;최정민
    • Journal of the Korean housing association
    • /
    • v.14 no.3
    • /
    • pp.119-126
    • /
    • 2003
  • The purpose of this study is to evaluate the natural ventilation performance for variable external wind speed as a preliminary step to determining the seasonal operating modes of the Double-skin Facade System applied to apartment buildings. For this purpose, two simulation programs are used to compare the Double-Skin Facade System with the Double Sash Window. First, TAS is used to plan a schedule for natural ventilation during the intermediate season and to analyze the cooling loads. Second, CFD is used for a more detailed airflow analysis on a typical floor plan of the model building. The results of the simulations on natural ventilation performance show that the Double-Skin Facade System can reduce the cooling load by 10.5% compared to the Double Sash Window.

ESTIMATES OF NET AIR-SEA FLUXES FOR THE TROPICAL AND SUBTROPICAL ATLANTIC BASED ON SATELLITE DATA

  • Katsaros, Kristina B.;Pinker, Rachel T.;Bentamy, Abderrahim;Carton, James A.;Drennan, William M.;Mestas-Nunez, Alberto M.
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.997-1000
    • /
    • 2006
  • We estimate the net heat flux in the tropical and subtropical Atlantic Ocean using satellite data. These fluxes are related to changes in sea surface temperature (SST). This variable influences atmospheric circulations and is indicative of surface and subsurface oceanic circulations. We employ data from the geostationary METEOSAT-7 and 8 satellites and from the Special Sensor Microwave/Imager (SSM/I) for the shortwave and long-wave radiative fluxes, and for estimates of SST. For turbulent flux calculations, we use the bulk aerodynamic method with satellite estimates for wind speed and atmospheric humidity and temperature.

  • PDF

Modeling and Control of Three-Phase Self-Excited Induction Generator Connected to Grid

  • Chandrasekaran, Natarajan;Karthikeyan, A
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.5
    • /
    • pp.265-272
    • /
    • 2017
  • This paper presents the dynamic modeling, analysis, and control of an AC/DC/AC-assisted, self-excited induction generator connected to the grid. The dynamic model includes wind turbine models with pitch control, gear boxes, self-excited induction generators, excitation capacitance, inductive load models, controlled six-pulse rectifiers, and novel state-space models of a grid-connected inverter. The system has been simulated to verify its capabilities of buildup voltage, stator flux response, stator phase current, electromagnetic torque, and magnetizing inductance variation during both the dynamic and steady states with a variable-speed prime mover. The complete setup of the above dynamic models was simulated using MATLAB/SIMULINK.

MVRS해수담수화 및 제염기술

  • 김상현;김동국;전원표
    • Proceedings of the Korea Technology Innovation Society Conference
    • /
    • 2001.05a
    • /
    • pp.285-302
    • /
    • 2001
  • At the present time the desalination technology of sea water for portable water in islands employs the RO method. The technology which needs complicated pretreatment processes with various chemicals can generate secondary water pollution and the high maintenance costs such as replacements of filters and membranes make islanders nearly impossible to operate. The MVRS technology for desalination of sea water however has several advantages such as constant production of quality portable water and capability of managing broad operating load. The variable-speed turbo-type vapor compressors employed in the system can utilize wind energy which is abundant in most Korean islands. Salt as a by-product can be produced by applying solar energy to the salt-concentrated waste water from the system. This paper discusses the relating topics such as technical and economical viabilities of the new MVRS desalination system for the production of portable water and salt as a by-product using new & renewable sources of energy.

  • PDF

Development of Bin Weather Data for Simplified Energy Calculations (간역열부하계산용(簡易熱負荷計算用) Bin기상(氣象)데이터)

  • Kim, Doo Chun;Choi, Jin Hee
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.1
    • /
    • pp.28-43
    • /
    • 1988
  • The purpose of this research is to produce bin weather data for Seoul from Standard Weather Data. The intended use of these data is for input to recently developed models for simplified energy calculations and for generating variable-base degree-day information. The data produced under this study include $3^{\circ}C$ bin data covering the full range of dry-bulb temperatures with mean coincident wet-bulb and daytime coincident solar radiation, wet-bulb bins down to freezing temperature, wind speed bins with prevailing directions, and heating and cooling degree hours to nine different temperature bases. All of these data are tabulated in six separate time periods and total daily categories for monthly and annual periods.

  • PDF

Protection relaying algorithm for DFIG using a DQ equivalent circuit (DQ 등가회로를 이용한 DFIG 보호계전방식)

  • Kang, Yong-Cheol;Lee, Ji-Hoon;Jang, Sung-Il;Kim, Yong-Gyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.23-24
    • /
    • 2007
  • Most of modern wind turbines employs a doubly-fed induction generator (DFIG) system because it has many advantages due to variable-speed operation, relatively high efficiency and it small converter size. The DFIG system uses a wound rotor induction machine so that the magnetizing current of the generator can be fed from both the stator and the rotor. This paper presents a protection relaying algorism for DFIG using the DQ equivalent circuits. The induced voltages calculated from the stator and rotor sides are nearly the same in the steady state. They become different in the DQ equivalent circuits during an internal fault. The proposed algorithm compares the inducted voltages estimated from the stator and the rotor circuit converted into the stationary reference frame. If the difference between the induced voltages exceeds the threshold, the proposed algorithm detects an turn-to-turn fault.

  • PDF

Modeling and Filtering of dv/dt Voltage Stress at Generator Terminal Due to Long Cable Between Inverter and Generator in Variable Speed Wind Energy Conversion System (가변속 풍력발전시스템의 인버터-발전기간 케이블 길이에 따른 풍력발전기 dv/dt 전압 모델링 및 저감대책)

  • Park, Chan-sol;Ham, Do-Hyun;Song, Seung-Ho;Kwon, Oh jung;Kang, Shin il
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.455-456
    • /
    • 2014
  • 본 논문에서는 인버터 스위치의 PWM 펄스 전압에 의해 발생하는 발전기 단자의 과전압 현상을 해석하기 위해, 전력 케이블과 발전기의 고주파 모델링을 제시하고, 이에 의한 과전압 현상을 해석한다. 또한, 이 과전압 현상을 억제하기 위한 적절한 형태의 인버터 출력단 dv/dt 필터를 설계하고, 선정된 dv/dt 필터 토폴로지의 필터 파라미터의 범위를 제시한다.

  • PDF

TRANSPORT AND DIFFUSION OF POLLUTANTS IN THE COASTAL WATERS OF ONSAN INDUSTRIAL COMPLEX (온산공단 부근의 해양오염물질 이동)

  • CHANG Sun-duck;LEE Jong-Sub;HAN Kyeong-Hwa
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.13 no.4
    • /
    • pp.151-162
    • /
    • 1980
  • To clarify the dispersion of pollutants introduced in the coastal region, a series of current measurements, the drogue and drift bottle experiments as well as the dye diffusion experiments were carried out in Onsan Bay and in the coastal waters of Ubong-ri near Ulsan. In the southeastern coastal region of Korean peninsula, that is, in the outside of Onsan Bay, the flood tidal current flows south-south-westward, and the ebb current flows north-north-eastward at a maximum speed of 1.0-1.1 knots at spring tide. In an inlet south of Cape Ubong, an anticyclonic eddy of 1 km in diameter is usually formed during both flood and ebb flows. The tidal current predominates in Onsan Bay at around spring tide. The maximum speed around spring tide was observed to be approximately 0.14 knot, while it was slower than 0.1 knot and variable at neap tide when the wind drift current played an important role. The flood tidal current flows westward while the ebb flow flows eastward in the northern region of the bay. The flood tidal current in the southern region of the bay flows west-north-westward, while the ebb current east-north-eastward. Wind drift currents in the coastal region of southern Korea are generally deduced to be southward in winter, the monthly mean speed being approximately 0.1 knot. Dye solution released at the northwestern corner in Onsan Bay was transported by eastward ebb tidal current toward the mouth of the bay dispersing by the wind. The apparent diffusion coefficient at 150 minutes after release in the bay was calculated to be $4.4\times10^4\;cm^2.sec^{-1}$, whereas that in the anticyclonic eddy was more or less smaller.

  • PDF