• Title/Summary/Keyword: Variable Range

Search Result 1,533, Processing Time 0.03 seconds

THE STUDY OF FLOOD FREQUENCY ESTIMATES USING CAUCHY VARIABLE KERNEL

  • Moon, Young-Il;Cha, Young-Il;Ashish Sharma
    • Water Engineering Research
    • /
    • v.2 no.1
    • /
    • pp.1-10
    • /
    • 2001
  • The frequency analyses for the precipitation data in Korea were performed. We used daily maximum series, monthly maximum series, and annual series. For nonparametric frequency analyses, variable kernel estimators were used. Nonparametric methods do not require assumptions about the underlying populations from which the data are obtained. Therefore, they are better suited for multimodal distributions with the advantage of not requiring a distributional assumption. In order to compare their performance with parametric distributions, we considered several probability density functions. They are Gamma, Gumbel, Log-normal, Log-Pearson type III, Exponential, Generalized logistic, Generalized Pareto, and Wakeby distributions. The variable kernel estimates are comparable and are in the middle of the range of the parametric estimates. The variable kernel estimates show a very small probability in extrapolation beyond the largest observed data in the sample. However, the log-variable kernel estimates remedied these defects with the log-transformed data.

  • PDF

Nonlinear, seismic response spectra of smart sliding isolated structures with independently variable MR dampers and variable stiffness SAIVS system

  • Nagarajaiah, Satish;Mao, Yuqing;Saharabudhe, Sanjay
    • Structural Engineering and Mechanics
    • /
    • v.24 no.3
    • /
    • pp.375-393
    • /
    • 2006
  • Under high velocity, pulse type near source earthquakes semi-active control systems are very effective in reducing seismic response base isolated structures. Semi-active control systems can be classified as: 1) independently variable stiffness, 2) independently variable damping, and 3) combined variable stiffness and damping systems. Several researchers have studied the effectiveness of independently varying damping systems for seismic response reduction of base isolated structures. In this study effectiveness of a combined system consisting of a semi-active independently variable stiffness (SAIVS) device and a magnetorheological (MR) damper in reducing seismic response of base isolated structures is analytically investigated. The SAIVS device can vary the stiffness, and hence the period, of the isolation system; whereas, the MR damper enhances the energy dissipation characteristics of the isolation system. Two separate control algorithms, i.e., a nonlinear tangential stiffness moving average control algorithm for smooth switching of the SAIVS device and a Lyapunov based control algorithm for damping variation of MR damper, are developed. Single and multi degree of freedom systems consisting of sliding base isolation system and both the SAIVS device and MR damper are considered. Results are presented in the form of nonlinear response spectra, and effectiveness of combined variable stiffness and variable damping system in reducing seismic response of sliding base isolated structures is evaluated. It is shown that the combined variable stiffness and variable damping system leads to significant response reduction over cases with variable stiffness or variable damping systems acting independently, over a broad period range.

Basic Theory on a Multi-Mode CVT (다중모드 무단 변속기의 구조이론에 관한 연구)

  • Lee, Jin-Won;Jang, Uk-Jin;Park, Jin-Ho;Park, Yeong-Il;Lee, Jang-Mu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.10 s.181
    • /
    • pp.2477-2486
    • /
    • 2000
  • A planetary gear assembly is a key component to combine and/or split a power from the source. With a planetary gear assembly, a continuously variable unit extends its capacity by means of power bra nching mechanism. Power branching with one planetary gear assembly and one continuously variable unit is categorized into 12 basic types. Each type represents peculiar power transmitting characteristics. Additionally, a multi-mode (range) continuously variable transmission can be designed with accompanying clutches. A multi-mode continuously variable transmission changes the path through which the source power is transmitted. Each path has its own features, such as high efficiency. In this paper, some design principles are examined such as, criteria to guarantee the minimum power efficiency, and constraints to guarantee the smooth mode shift after discussing well-known features of multi-mode M mathematically.

A Fundamental Study of a Variable Critical Nozzle Flow (가변형 임계 노즐유동에 관한 기초적 연구)

  • Kim, Jae-Hyung;Kim, Heuy-Dong;Park, Kyung-Am
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.484-489
    • /
    • 2003
  • The mass flow rate of gas flow through critical nozzle depends on the nozzle supply conditions and the cross-sectional area at the nozzle throat. In order that the critical nozzle can be operated at a wide range of supply conditions, the nozzle throat diameter should be controlled to change the flow passage area. This can be achieved by means of a variable critical nozzle. In the present study, both experimental and computational works are performed to develop variable critical nozzle. A cone-cylinder with a diameter of d is inserted into conventional critical nozzle. It can move both upstream and downstream, thereby changing the cross-sectional area of the nozzle throat. Computational work using the axisymmetric, compressible Navier-Stokes equations is carried out to simulate the variable critical nozzle flow. An experiment is performed to measure the mass flow rate through variable critical nozzle. The present computational results are in close agreement with measured ones. The boundary layer displacement and momentum thickness are given as a function of Reynolds number. An empirical equation is obtained to predict the discharge coefficient of variable critical nozzle.

  • PDF

Measurement and Prediction of the Visibility Range by the Variations of the Character Sizes and Illuminance (글자 크기와 조도의 변화에 의한 가시거리 측정과 예상)

  • Kim, Tae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8222-8227
    • /
    • 2015
  • The visibility range is defined from where one can see, which can be changed by the character sizes and illuminances and so on, which of one-hundred and twelve students are measured for three illuminances and three character sizes in this paper. In determining the character sizes and illuminances, the visibility range can be an important data. Functions are proposed whose independent variable is illuminance and whose dependent variable is visibility range in order to predict the visibility range of unmeasured illuminances. The fractional functions are used for three character sizes because the visibility range is invariant according to illuminance. There are three parameters to be determined - k, m, n, which are selected based on the measured visibility ranges. Because the visibility ranges of three character sizes are measured, three k's can be calculated. In this paper the case of minimum variance of three k's is selected, and three parameters - k,m,n- of that case is selected. The three functions according to three character sizes are proposed. The small differences between the measured data and the postulated functions verifies the accuracy of the functions.

Estimation on Clamping Force of High Strength Bolts Considering Temperature Variable of Both Site conditions and Indoor Environments (실내환경과 건설현장 온도변수를 고려한 고력볼트 체결력 예측)

  • Nah, Hwan-Seon;Lee, Hyeon-Ju
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.3
    • /
    • pp.32-40
    • /
    • 2015
  • The torque shear high strength bolt is clamped normally at the break of pin-tail specified. However, the clamping forces on slip critical connections do not often meet the required tension, as it considerably fluctuates due to torque coefficient dependent on lubricant affected temperature. In this study, the clamping tests of torque shear bolts were conducted independently at indoor conditions and at construction site conditions. During last six years, temperature of candidated site conditions was recorded from $-11^{\circ}C$ to $34^{\circ}C$. The indoor temperature condition was ranged from $-10^{\circ}C$ to $50^{\circ}C$ at each $10^{\circ}C$ interval. As for site conditions, the clamping force was reached in the range from 159 to 210 kN and the torque value was from 405 to $556 N{\cdot}m$. The range of torque coefficient at indoor conditions was analyzed from 0.126 to 0.158 while tensions were indicated from 179 to 192 kN. The torque coefficient at site conditions was ranged from 0.118 to 0.152. Based on this test, the variable trends of torque coefficient, tension subjected temperature can be taken by statistic regressive analysis. The variable of torque coefficient under the indoor conditions is $0.13%/^{\circ}C$ while it reaches $2.73%/^{\circ}C$ at actual site conditions. When the indoor trends and site conditions is combined, the modified variable of torque coefficient can be expected as $0.2%/^{\circ}C$. and the modified variable of tension can be determined as $0.18%/^{\circ}C$.

The Resourcefulness and the Health-Promoting Behaviors of Cancer Patients (암환자의 자원동원성과 건강증진행위)

  • Suh, Soon Rim;Kim, Hee Ju
    • Korean Journal of Adult Nursing
    • /
    • v.12 no.1
    • /
    • pp.112-121
    • /
    • 2000
  • The purpose of this study was to define the degree of the resourcefulness and the health-promoting behavior of cancer patients, to identify the relationship between the resourcefulness and the health promoting behaviors and to provide the basis for strategic nursing intervention. This study was conducted by an exploratory survey. Data were collected by self-reported questionnaires from 97 cancer patients in a university hospital in Tae-Gu from September to December of 1998. The sample data were collected by using a convenient sampling method. The following instruments were used in the study after some adaptation : Park Chai Soon's Health Promoting Lifestyle Profile, Oh Pok Ja's instrument for health promotion behavior and the Rosenbaum self-control schedule(SCS). The reliability of instruments was tested with Chronbach'alph(.79-.89). Data was analyzed by using the SAS program. T-test, ANOVA, and Pearson's coefficients of correlation. The results of this study were as follows: First, the average score of the resourcefulness variable was 22.20; the range of the score was from -30 to +81 The average score of the performance in the health promoting behavior variable was 96.13; the range of the score was from 39 to 137 Second, the resourcefulness variable was significantly different from such demographic factors as gender and perceived health status, but there was no statistically significant difference between the demographic factors and the health promoting behavior variable, except that of perceived health status. Third, the performance in health promoting behavior of cancer patients was significantly correlated with the resourcefulness of cancer patients(r= .50) In conclusion, resourcefulness was identified to be an important variable that could contribute to promote health-promoting behavior.

  • PDF

Optimal Weapon-Target Assignment Algorithm for Closed-In Weapon Systems Considering Variable Burst Time (가변 연속사격 시간을 고려한 근접 방어 시스템의 최적 무장 할당 알고리듬)

  • Kim, Bosoek;Lee, Chang-Hun;Tahk, Min-Jea;Kim, Da-Sol;Kim, Sang-Hyun;Lee, Hyun-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.5
    • /
    • pp.365-372
    • /
    • 2021
  • This paper deals with an optimal Weapon-Target Assignment (WTA) algorithm for Closed-In Weapon Systems (CIWS), considering variable burst time. In this study, the WTA problem for CIWS is formulated based on Mixed Integer Linear Programming (MILP). Unlike the previous study assuming that the burst time is fixed regardless of the engagement range, the proposed method utilizes the variable burst time based on the kill probability according to the engagement range. Thus, the proposed method can reflect a more realistic engagement situation and reduce the reaction time of CIWS against targets, compared to the existing method. In this paper, we first reformulate the existing MILP-based WTA problem to accommodate the variable burst Time. The proposed method is then validated through numerical simulations with the help of a commercial optimization tool.

A STUDY ON THE CHANGES OF THE ELASTIC PROPERTIES TN LOOPED WIRES BY VARIABLE FACTORS (변환요소에 따른 LOOPED WIRE의 탄성 변화에 관한 연구)

  • Na, Yong-In;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.25 no.3 s.50
    • /
    • pp.263-271
    • /
    • 1995
  • The purpose of this study nab to evlauate and compare the effect of the variable factors of wire on the elastic properties of looped rectangular wire. Five variable factors were presented-material(Hi-T, blue Elgiloy), wire size(.016'$\;\times\;$.022', .018'$\;\times\;$.025'), loop length(15mm, 20mm), loop configuration(open loop, closed loop), gabling (non-gable, gable). So, the total 256 specimens were divided into 32 groups, and each of those nab pulled on Instron testing machine. The load-deflection curve of each wire obtained, from which force, range in elastic limit, and stiffness were computed and analyzed statistically. The results were obtained as follows : 1. All of the variable factors - wire material, size, loop length loop configuration, and gabling - took a significant effect on load-deflection rate of looped wire. 2. The force at elastic limit was the smallest in the group of Hi-T, .016'$\;\times\;$.022', 20mm loop length, open loop, non-gable, and the largest in the group of blue Elgiloy, .018'$\;\times\;$.025', 15mm loop length, closed loop, non-gable. 3. The range at elastic limit was the smallest in the group of Hi-T, .018'$\;\times\;$.025', 15mm loop length, open loop, non-gable, and the largest in the group of HI-T, .016'$\;\times\;$.022', 20mm loop length, closed loop, gable. 4. Loop configuration and loop length were the most effective factors on the elastic properties of looped wires, and gabling was the least effective.

  • PDF

A Single-Stage 37 dB-Linear Digitally-Controlled Variable Gain Amplifier for Ultrasound Medical Imaging

  • Cho, Seong-Eun;Um, Ji-Yong;Kim, Byungsub;Sim, Jae-Yoon;Park, Hong-June
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.5
    • /
    • pp.579-587
    • /
    • 2014
  • This paper presents a variable gain amplifier (VGA) for an analog front-end (AFE) of ultrasound medical imaging. This VGA has a closed-loop topology and shows a 37-dB-linear characteristic with a single-stage amplifier. It consists of an op-amp, a non-binary-weighted capacitor array, and a gain-control block. This non-binary-weighted capacitor array reduces the required number of capacitors and the complexity of the gain-control block. The VGA has been fabricated in a 0.35-mm CMOS process. This work gives the largest gain range of 37 dB per stage, the largest P1 dB of 9.5 dBm at the 3.3-V among the recent VGA circuits available in the literature. The voltage gain is controlled in the range of [-10, 27] dB in a linear-in-dB scale with 16 steps by a 4-bit digital code. The VGA has a bandpass characteristic with a passband of [20 kHz, 8 MHz].