• Title/Summary/Keyword: Variable Frequency

Search Result 2,110, Processing Time 0.029 seconds

Expansion of Variable Range of Oscillation Frequency of Active Phased Array Antenna by a Varactor Diode (바랙터다이오드에 의한 능동 위상차 배열 안테나의 발진 주파수 가변 범위의 확장)

  • 최영규
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.11
    • /
    • pp.521-528
    • /
    • 2003
  • A varactor diode was utilized in order to expand variable range of the natural oscillation frequency of an active phased-array antenna. We have conformed experimentally that the variable range of the natural oscillation frequency was expanded about three times in the oscillator controlled by the varactor diode. When frequency difference was given to the oscillators in the two elements antenna system, phase difference was appeared between the oscillators. The 2-, 3-, 5-elements patch antenna array was composed for the beam scanning experiments. All the above patch antennas showed good phased array characteristics. The experimental results are as follows that the scanning angle of the 2-elements array antenna is 28.6$^{\circ}$, the 3-elements array antenna is 29.4$^{\circ}$, and the 5-elements array antenna is 26.2$^{\circ}$.

Study on Optimum Design Condition for Variable Speed Control of Rated Speed Fans used in a Power Plant (발전소 통풍계통의 가변속 운전을 위한 최적 설계조건에 관한 연구)

  • Cho, C.W.;Yang, K.H.;Jung, N.K.;Kim, B.J.
    • Journal of Power System Engineering
    • /
    • v.14 no.5
    • /
    • pp.30-35
    • /
    • 2010
  • Recently, the large capacity draft fans in power plants had been changed to variable speed type to educe the power consumption. But the fan experienced the unexpected vibration at specific speed regions. In this study, the high vibration frequency of the fan was confirmed and the natural frequency of the rotor were measured and analyzed by FEM programs. It was analyzed that the vibration was caused by the resonance at the frequency, 30.7Hz. So, the rotor vibration characteristic was changed by adjusting the distance between the shaft bearings. It was conformed the high vibration was disappeared over the all operation speeds.

Design of Voltage Controlled Oscillator using Miller Effect

  • Choi Moon-Ho;Kim Yeong-Seuk
    • Proceedings of the IEEK Conference
    • /
    • summer
    • /
    • pp.218-220
    • /
    • 2004
  • A new wide-band VCO topology using Miller capacitance is proposed. Contrary to conventional VCO using the Miller capacitance where the variable amplifier gain is negative, the proposed VCO uses both the negative and positive variable amplifier gain to enhance the frequency tuning range significantly. The proposed VCO is simulated using HSPICE. The simulations show that 410MHz and 220MHz frequency tuning range are obtained using the negative .and positive variable amplifier gain, respectively. The tuning range of the proposed VCO is $23\%$ of the center frequency(2.8GHz). The phase noise is -104dBc/Hz at 1MHz offset by simple model. The operating current is only 3.84mA at 2.5V power supply.

  • PDF

Development of Ground Impedance Measuring Instrument for Lightning Protection System (뇌보호 설비를 위한 접지임피던스 측정기 개발)

  • Lee, Tae-Hyung;Cha, Sung-Chul;Earn, Ju-Hang
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.194-195
    • /
    • 2006
  • This study evaluated the impedance characteristics of earth termination system and developed a variable frequency-typed inverter (measuring tool) for the utilization in ground design for lightning protection. The variable-frequency-typed inverter were composed of rectification part, voltage adjuster, IGBT controller and measuring part. Meanwhile, the square wave signal of variable frequency converted its frequency up to lightning surge band by using an IGBT after rectifying an alternating current (AC). It conducted performance evaluation of ground impedance of actual earth termination system by using the developed measuring tool for ground impedance and confirmed that such impedance-oriented performance evaluation was effective in the design of lightning protection.

  • PDF

Realization of Variable Bandwidth Filter for Decomposition of Speech Signals into AM-FM Components (음성신호의 AM-FM 성분 분리를 위한 가변대역폭 필터 구현)

  • 이희영;김용태
    • Proceedings of the IEEK Conference
    • /
    • 2003.07e
    • /
    • pp.2208-2211
    • /
    • 2003
  • In this paper, a variable bandwidth filter(VBF) is realized with the purpose of the decomposition of speech signals with time-varying instantaneous of frequencies. The proposed VBF can extract AM-FM components of a speech signal whose time-frequency representations(TFRs) are not overlapped in time-frequency domain

  • PDF

An Effect of Sampling Rate to the Time and Frequency Domain Analysis of Pulse Rate Variability (샘플링율이 맥박변이도 시간 및 주파수 영역 분석에 미치는 영향)

  • Yang, Yoon La;Shin, Hangsik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1247-1251
    • /
    • 2016
  • This study aims to investigate the effect of sampling frequency to the time domain and frequency domain analysis of pulse rate variability (PRV). Typical time domain variables - AVNN, SDNN, SDSD, RMSSD, NN50 count and pNN50 - and frequency domain variables - VLF, LF, HF, LF/HF, Total Power, nLF and nHF - were derived from 7 down-sampled (250 Hz, 100 Hz, 50 Hz, 25 Hz, 20 Hz, 15 Hz, 10 Hz) PRVs and compared with the result of heart rate variability of 10 kHz-sampled electrocardiogram. Result showed that every variable of time domain analysis of PRV was significant at 25 Hz or higher sampling frequency. Also, in frequency domain analysis, every variable of PRV was significant at 15 Hz or higher sampling frequency.

Planar Frequency-Reconfigurable Monopole Antenna Design (가변 주파수 특성을 갖는 평면형 모노폴 안테나 설계)

  • Kim, Youngkyu;Lim, Joingsik;Han, Sang-Min
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.11
    • /
    • pp.1121-1127
    • /
    • 2014
  • In this paper, a planar frequency reconfigurable antenna is proposed with variable capacitors. The proposed one is designed with a planar monopole, and varies resonant frequencies by variable capacitive loading of a varactor diode. The equivalent circuit and electromagnetic(EM) simulation are utilized for the analysis at the variable characteristic design of the antenna, and the same radiation performance. The implemented frequency variable monopole antenna has been verified by comparing prototypes with designed capacitors and ones with biased varactor diodes. The proposed antenna has presented the resonant frequency variations from 2.25 GHz to 2.42 GHz.

A Novel Method for Measuring the Ground Impedance using Variable Frequency Inverter (가변주파수 인버터를 이용한 접지임피던스의 새로운 측정기법)

  • 이복희;엄주홍
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.5
    • /
    • pp.253-257
    • /
    • 2004
  • In order to analyze the frequency dependance of ground impedance in grounding grids for lightning and surge protection, a novel method for measuring the ground impedance as a function of frequency were experimentally investigated. The experiments were carried out in rectangular grounding grids with $6{\times}8$ conductors of 22 $mm^2$ buried at a depth of 0.5 m. The test current was injected by the variable frequency inverter whose frequency is linearly controlled for the established period in the range of 5∼500 KHz. The amplitude and phase of ground impedance were calculated from the waveforms of the test current and ground potential rise measured by the band-pass filter tuned in a specific frequency. The frequency dependence of ground impedance was mainly caused by the inductive current flowing through grounding conductors over the frequency of 100 KHz. The proposed measurement method of ground impedance would be applicable to evaluate the transient response characteristics in lightning protection grounding systems.

Dynamic Characteristics Analysis for the Online Monitoring System Designing KTX MRU and Improvement of the Stability Related Variable High Speed (고속열차 감속기의 상시감시시스템 설계 및 가변속주행시 안정성 향상을 위한 동특성해석)

  • Park, Byung Su;Kim, Jin Woo;Choi, Sang Rak;Song, Young Chun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.4
    • /
    • pp.301-307
    • /
    • 2013
  • MRU(motor reduction unit) for KTX is a assembled complex structure that is equipped with a lot of parts at the express train KTX and that is the core power source operating variable speeds. This study is recorded the dynamic characteristics analysis results tested by EMA which is done through the parts and assembly test, transient analysis and stoped train test in order to design the online monitoring system for KTX MRU. And the mode shapes result from critical vibration frequency explain the relation with variable speeds of express train over 250 km/hr. Also these variable speeds make variable operational frequencies at pinion, axle gear mesh frequency and normal bearing fault frequencies. As the specified speed can make resonance with natural frequencies of the MRU, for the train operating stability, this study also presents the MRU's critical speeds calculated by the each train speed.

Analysis and Application of Repetitive Control Scheme for Three-Phase Active Power Filter with Frequency Adaptive Capability

  • Sun, Biaoguang;Xie, Yunxiang;Ma, Hui;Cheng, Li
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.618-628
    • /
    • 2016
  • Active power filter (APF) has been proved as a flexible solution for compensating the harmonic distortion caused by nonlinear loads in power distribution power systems. Digital repetitive control can achieve zero steady-state error tracking of any periodic signal while the sampling points within one repetitive cycle must be a known integer. However, the compensation performance of the APF would be degradation when the grid frequency varies. In this paper, an improved repetitive control scheme with frequency adaptive capability is presented to track any periodic signal with variable grid frequency, where the variable delay items caused by time-varying grid frequency are approximated with Pade approximants. Additionally, the stability criterion of proposed repetitive control scheme is given. A three-phase shunt APF experimental platform with proposed repetitive control scheme is built in our laboratory. Simulation and experimental results demonstrate the effectiveness of the proposed repetitive control scheme.