• 제목/요약/키워드: Variable Constant Current

검색결과 133건 처리시간 0.028초

Parameter Identification of Induction Motors using Variable-weighted Cost Function of Genetic Algorithms

  • Megherbi, A.C.;Megherbi, H.;Benmahamed, K.;Aissaoui, A.G.;Tahour, A.
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권4호
    • /
    • pp.597-605
    • /
    • 2010
  • This paper presents a contribution to parameter identification of a non-linear system using a new strategy to improve the genetic algorithm (GA) method. Since cost function plays an important role in GA-based parameter identification, we propose to improve the simple version of GA, where weights of the cost function are not taken as constant values, but varying along the procedure of parameter identification. This modified version of GA is applied to the induction motor (IM) as an example of nonlinear system. The GA cost function is the weighted sum of stator current and rotor speed errors between the plant and the model of induction motor. Simulation results show that the identification method based on improved GA is feasible and gives high precision.

ER 스퀴즈 필름 댐퍼로 지지된 고속 회전 로터의 동적 계수에 관한 연구 (Dynamic Coefficients of a High-Speed Rotor Supported by a Slotted ER Squeeze Film Damper)

  • 이용복;김창호;정시영;이남수;최동훈
    • 소음진동
    • /
    • 제10권6호
    • /
    • pp.1029-1034
    • /
    • 2000
  • A new electro-rheological squeeze film damper (ER-SFD) has been sealed with slotted piston rings which have electrodes at the inside of the constant gap. The slotted ER-SFD can prevent the problem of electric discharge which might be occurred in the previous configuration of an ER-SFD. The current paper presents the extraction of linearized dynamic coefficients within small orbit where these coefficients are controlled by the application of electric strength. Test rig has been modified to isolate the damper section for dynamic coefficient extraction. The results show that rotordynamic coefficients, damping and inertia terms, increase with increasing supply voltages, while stiffness coefficients decrease with increasing supply voltages. notating speed of rigid shaft does not affect these coefficients.

  • PDF

직류서보전동기의 속도제어를 위한 퍼지-관측기 설계 (Design of a Fuzzy-Observer for Speed Control applied to DC Servo Motor)

  • 김명준;윤광호;김상훈;남문현;김낙교
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2255-2257
    • /
    • 2002
  • In this paper, Fuzzy-Observer is designed to control the speed of DC Servo Motor. Fuzzy-Observer estimates the speed of DC Servo Motor with the measurement of the amature current. The constant speed and variable speed experiments are excuted to evaluate the performance of Fuzzy-Observer.

  • PDF

SRM의 위치-속도 추정을 위한 관측자 설계 (Observer Design of SRM for Position-Velocity Estimation)

  • 이태규;김정태;허욱열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.219-222
    • /
    • 1994
  • This thesis describes an observer of Switched Reluctance Motor for position. velocity and torque estimation using current sening. Inductance of SRM varies trapezoidally with respect to the rotor position. This means that the inductance of each phase is a periodic function with the same period. Under this condition. the observer with a constant gain can be developed though SRM has nonlinear characteristics. Because SRM has equivalent physical meaning with each period. The stability of error system which is the difference between actual system and observer system. is analyzed using Lyapunov and variable structure theory. The effectiveness of the proposed estimation is shown by various simulation.

  • PDF

The development of a high efficient transcranial magnetic stimulation adopted real time-charging-discharging circuit

  • Kim, Whi-Young;Park, Sung-Joon
    • 전기전자학회논문지
    • /
    • 제14권2호
    • /
    • pp.9-15
    • /
    • 2010
  • In this study, we have been proposed the new type of a transcranial magnetic stimulation adopted a variable voltage capacitor with Cockcroft-Walton circuit and constant-frequency current resonant half-bridge inverter. This a transcranial magnetic stimulation has some merits compared with the conventional one. First, it doesn't require the high voltage transformer. And second, it has less switching losses, compact size and capability in adjusting the transcranial magnetic stimulation output energy precisely. In this paper, we have performed the output characteristics of a transcranial magnetic stimulation system which is well known as magnetic stimulation. The tested results are described as a function of pulse repetition rate and switching numbers of the half-bridge inverter.

Full ZVS Load Range Diode Clamped Three-level DC-DC Converter with Secondary Modulation

  • Shi, Yong
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.93-101
    • /
    • 2016
  • A new four-primary-switch diode clamped soft switching three-level DC-DC converter (TLDC) with full zero-voltage switching (ZVS) load range and TL secondary voltage waveform is proposed. The operation principle and characteristics of the presented converter are discussed, and experimental results are consistent with theoretical predictions. The improvements of the proposed converter include a simple and compact primary structure, TL secondary rectified voltage waveform, wide load range ZVS for all primary switches, and full output-regulated range with soft switching operation. The proposed converter also has some disadvantages. The VA rating of the transformer is slightly larger than that of conventional TLDCs in variable input and constant output mode. The conduction loss of the primary coil is slightly higher because an air gap is inserted into the magnetic cores of the transformer. Finally, the secondary circuit is slightly complex.

Plutonium mass estimation utilizing the (𝛼,n) signature in mixed electrochemical samples

  • Gilliam, Stephen N.;Coble, Jamie B.;Goddard, Braden
    • Nuclear Engineering and Technology
    • /
    • 제54권6호
    • /
    • pp.2004-2010
    • /
    • 2022
  • Quantification of sensitive material is of vital importance when it comes to the movement of nuclear fuel throughout its life cycle. Within the electrorefiner vessel of electrochemical separation facilities, the task of quantifying plutonium by neutron analysis is especially challenging due to it being in a constant mixture with curium. It is for this reason that current neutron multiplicity methods would prove ineffective as a safeguards measure. An alternative means of plutonium verification is investigated that utilizes the (𝛼,n) signature that comes as a result of the eutectic salt within the electrorefiner. This is done by utilizing the multiplicity variable a and breaking it down into its constituent components: spontaneous fission neutrons and (𝛼,n) yield. From there, the (𝛼,n) signature is related to the plutonium content of the fuel.

HIGH SPEED VARIABLE SQUARE WAVE AC SUBMERGED ARC WELDING -FREQUENCY/BALANCE STUDY .250″ PLAIN CARBON STEEL

  • Reynolds, Jon-O;Sean P. Moran
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.361-365
    • /
    • 2002
  • Advancements in silicon phase control (SCR) technologies provide an arc welding power supply that has the capability to allow the alteration of the Alternating Current (AC) welding output. These technologies provide a square wave output involving sixteen frequency selections and multiple balance selections. While an AC out put is known to minimize magnetic disturbances associate with Direct Current (DC), the potentials of a non-sinusoidal waveform have not been explored. The focus of the paper is to determine the effects that the frequency and balance of an AC wave form output will have upon a high speed Submerge Arc (SAW) application. The test matrix of the project includes welding .250" steel plate. Joint type is square groove with a travel speed of 65 IPM. Each of the weld parameters was held constant, only the frequency and/or balance were altered between welds. Each frequency/balance combination involved three-gap spacing. Upon completion of the welds the bead profiles were measured and recorded. A relationships/trends were observed with various frequency and balance values. Optimum frequency and balance values were found for the .250" square groove application which permit consistent weld sizing, ease of slag removal, and minimal plate distortion.

  • PDF

저속영역에서 센서리스 벡터제어 유도전동기의 성능을 향상시키기 위한 MRAC 기반의 강인한 속도 추정 기법 (A Robust MRAC-based Speed Estimation Method to Improve the Performance of Sensorless Induction Motor Drive System in Low Speed)

  • 박철우;권우현
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권1호
    • /
    • pp.37-46
    • /
    • 2004
  • A novel rotor speed estimation method using model reference adaptive control(MRAC) is proposed to improve the performance of a sensorless vector controller. In the proposed method, the stator current is used as the model variable for estimating the speed. In conventional MRAC methods, the relation between the two model errors and the speed estimation error is unclear. In the proposed method, the stator current error is represented as a function of the first degree for the error value in the speed estimation. Therefore, the proposed method can produce a fast speed estimation. The robustness of the rotor flux-based MRAC, back EMF-based MRAC, and proposed MRAC is compared based on a sensitivity function about each error of stator resistance, rotor time constant, mutual inductance. Consequently, the proposed method is much more robust than the conventional methods as regards errors in the mutual inductance, stator resistance. Therefore, the proposed method offers a considerable improvement in the performance of a sensorless vector controller at a low speed. In addition, the superiority of the proposed method and the validity of sensitivity functions were verified by simulation and experiment.

약물치료의 부작용개선을 위한 이온도입 시스템(WIT-I)에 관한 연구 (A Study on the Ion Transfer System(WIT-I) for Improve on Side effect of Pharmacotherapy)

  • 어윤기;양경모;채진욱;이인섭;이재형;정동명
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.226-231
    • /
    • 1996
  • Recently Iontophoresis is tried to physical therapy field.. It is method for direct penetrate to skin with ionization pharmacon because it is decreased side effect of pharmacon treatment such as gastrophathy and aphylaris of disease-causing germs. We designed WIT-I that is trial manufacture for clinical experiment This system is has been elrectrical paramete with 0-140V out range, 1-7mA current 1-15mim time set. Invite experiment, WIT-I kept designed performance which is a constant current in variable load resistance such as skin and electrode contact. It is estimated to have a practical use for physical therapy by iontophcresis.

  • PDF