• 제목/요약/키워드: Vaporization Rate

검색결과 100건 처리시간 0.027초

열증착법으로 합성된 ZnO 나노 구조체의 구조적 특성 (Structural characteristics of ZnO nanostructures synthesized by the thermal evaporation method)

  • 방신영;김우식;정준호;최봉근;심광보
    • 한국결정성장학회지
    • /
    • 제18권2호
    • /
    • pp.81-86
    • /
    • 2008
  • 열증착법(thermal evaporation method)에 의해 ZnO 나노선을 합성하였다. 나노선 합성조건에 따른 구조적 특성을 분석하여 그 합성 메카니즘을 확인하였다. ZnO 나노선 합성 시 기화 온도가 고온일수록 성장속도가 빠르고 $CO/CO_2$ 분압이 역전되는 1000$^{\circ}C$ 이상에서는 그 형태가 크게 변화하고, 성장온도 700$^{\circ}C$ 이상에서 Au 촉매가 그 기능을 하고 있음을 확인하였다. 성장된 ZnO 나노선은 380 nm에서의 blue emission을 나타냄을 확인하였다.

Botulinum Toxin Type A (BOTOX$^{\circledR}$)를 이용한 성대 육아종의 치료효과 (The Effect of Botulinum Toxin Type A for the Vocal Fold Granuloma)

  • 김정홍;김한수;남지인;장정현;김지훈;최홍식
    • 대한후두음성언어의학회지
    • /
    • 제14권1호
    • /
    • pp.40-46
    • /
    • 2003
  • Background and Objectives : The vocal fold granuloma has been associated with vocal abuse, gastroesophageal reflux, endotracheal intubation and habitual throat clearing etc.. Granuloma is benign growth of hypertrophic granulation tissue. It is usually located on the posterior third of vocal fold, in one or both vocal process of the arytenoid cartilage In spite of the voice therapy, steroid therapy, anti-reflex therapy and surgical procedure. The distinct advantage and uniform success rate of each methods have not been generally shown. Authors report that localized injection of botulinum toxin type A (BOTOX$^{\circledR}$) is the promising method both as an initial treatment and as an alternative treatment in patients who do not respond to standard therapy or who are poor surgical candidates. Materials and Method : We carried out a retrospective study of 9 patients with the diagnosis of vocal fold granuloma on the videostroboscopic examination from Jan 2000 to Mar 2003. The botulinum toxin type A was injected into one or both thyroarytenoid muscle or lateral cricoarytenoid muscle under the electromyography. The average dosage ranges from 6U to 8U per injection. Results : Unilateral vocal fold granuloma in 7 patients had been resolved completely within 2-3 months after first injection : 5 patients received th\ulcorner GER medical therapy in addition to the Botulinum toxin injections, 2 patients was resolved completely who had shown recurrence after $CO_2$ laser vaporization. 2 patients who had shown recurrence after $1^st$ injection were also completely resolved within 6 months after further injections. Conclusion : We expect that localized injection of Botulinum toxin type A can provide an alternative treatment for the refractory cases to the traditional forms of therapy and avoid the recurrence in conjunction with proper medical and voice therapy against GER and vocal abuse.

  • PDF

입구 와류발생과 질량분사가 있는 연소실 내부유동의 LES 해석 (LES for Turbulent Duct Flow with Surface Mass Injection and Vortex Shedding)

  • 몬킨우;구희석;이창진
    • 한국항공우주학회지
    • /
    • 제40권9호
    • /
    • pp.745-751
    • /
    • 2012
  • 하이브리드 로켓은 축 방향의 산화제 유동과 고체 연료의 기화로 인한 벽면 분출 유동사이의 상호 간섭에 의해 복잡한 형태의 혼합 전단층이 존재한다. 연소실 입구에 링이 설치되어 있고 질량분사가 있는 실린더 유동에 대하여 압축성 효과를 고려한 LES(Large Eddy Simulation) 기법을 적용하여 수치계산을 수행하였다. 최근의 실험에 의하면 연료 중간에 링과 같은 다이아프램이 설치된 경우, 연소율의 증가가 관찰되었다. 계산 결과에 따르면, 축방향 유동과 벽면 분출 유동이 상호 간섭하여 발생하는 벽면 와류가 국부적인 연료 표면으로의 열전달을 증가시켜 실험에서 관찰되는 딤플이 생성되는 것을 확인하였다. 또한 연소실 입구에 설치된 링에 의하여 발생되는 와류는 벽면 와류가 보다 활발하게 생성되고 열전달과 혼합을 향상시키는 역할을 하며 이 때문에 연소율이 증가되는 것으로 보인다.

충전(充塡)된 아말감 제거시(除去時) 발생(發生)되는 수은증기량(水銀蒸氣量) 측정(測定)에 관(關)한 연구(硏究) (A STUDY OF THE MERCURY VAPOR MEASUREMENT DURING AMALGAM REMOVAL)

  • 나긍균;민병순;최호영;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제10권1호
    • /
    • pp.85-92
    • /
    • 1984
  • The aim of this study was to examine the influence of the speed of grinding and coolants on mercury vaporization during amalgam removal. Forty amalgam filled stone dies were stored at $37^{\circ}C$ and 100% relative humidity for 7 days prior to the beginning of the mercury vapor experiment and were divided into 4 different groups; In Group I; Used by high speed without coolant & evacuator during amalgam removal. In Group II; Used by high speed with coolant & evacuator during amalgam removal. In Group III; Used by low speed without coolant & evacuator during amalgam removal. In Group IV; Used by low speed with coolant & evacuator during amalgam removal. The amalgam specimens were removed in a 30-second time period and mercury vapor was collected with membrane filter at 27mm from the site of removal and 45 degree above there. Samples in Group II, IV were removed with coolant spray at a flow rate of 30 ml/min with high-velocity evacuator. Mercury vapor collected membrane filter was analysed by Atomic Absorption Spectrophotometer using cold vapor method. The results were as follows; 1. The mercury vapor levels were obtained all of the Groups. 2. The mercury vapor levels of the Group II, IV (with coolant & evacuator) were less than that of the Group I, III (without coolant & evacuator). 3. The highest mercury vapor level recorded during amalgam removal procedure was Group I (used by high speed without coolant & evacuator) and its record was $0.78{\pm}0.09\;mg/m^3$, which exceed the T.L.V. by 15 times. 4. The mercury vapor level of the Group IV (used by low speed with coolant & evacuator) was more than that of the Group II (used by high speed with coolant & evacuator), but its difference was not significant, statistically. (p > 0.05)

  • PDF

Hydrogen and Ethanol Gas Sensing Properties of Mesoporous P-Type CuO

  • Choi, Yun-Hyuk;Han, Hyun-Soo;Shin, Sun;Shin, Seong-Sik;Hong, Kug-Sun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.222-222
    • /
    • 2012
  • Metal oxide gas sensors based on semiconductor type have attracted a great deal of attention due to their low cost, flexible production and simple usability. However, most works have been focused on n-type oxides, while the characteristics of p-type oxide gas sensors have been barely studied. An investigation on p-type oxides is very important in that the use of them makes possible the novel sensors such as p-n diode and tandem devices. Monoclinic cupric oxide (CuO) is p-type semiconductor with narrow band gap (~1.2 eV). This is composed of abundant, nontoxic elements on earth, and thus low-cost, environment-friendly devices can be realized. However, gas sensing properties of neat CuO were rarely explored and the mechanism still remains unclear. In this work, the neat CuO layers with highly ordered mesoporous structures were prepared by a template-free, one-pot solution-based method using novel ink solutions, formulated with copper formate tetrahydrate, hexylamine and ethyl cellulose. The shear viscosity of the formulated solutions was 5.79 Pa s at a shear rate of 1 s-1. The solutions were coated on SiO2/Si substrates by spin-coating (ink) and calcined for 1 h at the temperature of $200{\sim}600^{\circ}C$ in air. The surface and cross-sectional morphologies of the formed CuO layers were observed by a focused ion beam scanning electron microscopy (FIB-SEM) and porosity was determined by image analysis using simple computer-programming. XRD analysis showed phase evolutions of the layers, depending on the calcination temperature, and thermal decompositions of the neat precursor and the formulated ink were investigated by TGA and DSC. As a result, the formation of the porous structures was attributed to the vaporization of ethyl cellulose contained in the solutions. Mesoporous CuO, formed with the ink solution, consisted of grains and pores with nano-meter size. All of them were strongly dependent on calcination temperature. Sensing properties toward H2 and C2H5OH gases were examined as a function of operating temperature. High and fast responses toward H2 and C2H5OH gases were discussed in terms of crystallinity, nonstoichiometry and morphological factors such as porosity, grain size and surface-to-volume ratio. To our knowledge, the responses toward H2 and C2H5OH gases of these CuO gas sensors are comparable to previously reported values.

  • PDF

고온 연료가스 정제를 위한 ZnO-CuO 혼성탈황제의 반응 특성연구 (A Study on Reactivity of ZnO-CuO Sorbent for Hot Gas Desulfurization)

  • 정용길;박노국;전진혁;이종대;류시옥;이태진
    • 청정기술
    • /
    • 제9권4호
    • /
    • pp.189-196
    • /
    • 2003
  • 고온 연료가스 정제를 위하여 ZnO-CuO 혼합탈황제를 제조하였으며, 탈황제들의 반응특성을 조사하였다. ZnO와 CuO의 혼합비율에 따른 황화반응 속도는 CuO의 함량이 증가할수록 빨라졌다. ZnO와 CuO 비율을 달리한 각 탈황제의 재생특성을 조사하기 위하여 TPO실험을 수행한 결과, $400^{\circ}C$ 이상에서 $CuSO_4$가 생성되고 $700^{\circ}C$ 이상에서 $CuSO_4$가 열분해 됨을 알았다. $600^{\circ}C$에서 재생된 탈황제는 $CuSO_4$에 의한$SO_2$ slippage 현상이 관찰되었으나, $700^{\circ}C$에서 재생할 경우에는 $SO_2$ slippage가 관찰되지 않았다. 이로써 ZnO와 CuO의 혼합으로 CuO는 ZnO의 휘발을 억제하고, ZnO는 CuO에 대한 $SO_2$ slippage를 최소화 시켰다.

  • PDF

축분 고형연료의 열분해 동역학 연구 (Kinetic Analysis for the Pyrolysis of Solid Refues Fuel Using Livestock Manure)

  • 장은석;송은혜;윤종혁;김영민
    • 공업화학
    • /
    • 제31권4호
    • /
    • pp.443-451
    • /
    • 2020
  • 본 연구에서는, 축분 고형연료의 연료적 가치를 판단하기 위해 물리화학적 특성과 열분해 동역학 분석을 수행하였다. 원소분석과 공업분석결과는 축분 고형연료는 휘발성 물질(64.94%), 탄소(44.35%) 및 수소(5.54%)의 함량이 높았다. 축분 고형연료의 저위발열량(3,880 kcal/kg) 또한 가축분뇨 고형 연료 기준(3,000 kcal/kg)보다 높았다. 열중량분석결과 축분연료는 3개의 분해온도구간을 가졌다. 첫 번째 온도구간(130~330 ℃)은 추출물의 기화, 헤미셀룰로우스 및 셀룰로우스의 분해로 구성되었다. 두 번째(330~480 ℃)와 세 번째(550~800 ℃) 온도 구간들은 리그닌의 분해와 carbonaceous materials 분해에 의한 것이었다. Friedman, FWO, KAS 같은 model free 분석방법에 의해 구해진 축분 고형연료의 열분해에 대한 활성화 에너지 값은 전환율 0.1에서 0.9 범위에서 173.98에서 525.79 kJ/mol로 나타났다. 특히, 전환율이 0.6보다 높은 구간에서 활성화에너지가 크게 증가하였다. Curve fitting 방법을 사용한 동역한 분석은 축분 고형연료가 5단계의 분해 단계로 구분될 수 있는 다단계 반응에 의해 분해됨을 제안하였다.

인공토양으로부터 토양증기추출법에 의한 유기화합물의 탈착 현상에 관한 실험 연구 (Desorption of organic Compounds from the Simulated Soils by Soil Vapor Extraction)

  • 이병환;이종협
    • 한국토양환경학회지
    • /
    • 제3권2호
    • /
    • pp.101-114
    • /
    • 1998
  • 토양오염 정화방법의 하나인 토양증기추출법 (soil vapor extraction, SVE) 은 오염된 토양에 진공 또는 가압의 공기를 공급하여 연속적인 공기 흐름을 유도함으로써 토양의 기공에 잔류하는 유해화합물의 증발을 촉진하여 오염물질을 제거하는 공정이다. 본 연구에서는 토양증기추출법의 효율에 영향을 주는 인자들 가운데에서 토양의 수분함량과 오염물질의 종류가 오염물질의 제거효율에 미치는 영향에 대하여 실험연구를 수행하였다. 인공토양으로 미세기공이 없는 glass bead, sand, 그리고 미세기공이 많고 흡착능이 강한 molecular sieve가 사용되었으며, 오염물질로는 톨루엔, 메틸에틸케톤, 트리클로로에틸렌이 사용되었다. 본 연구에서는 오염물질의 탈착실험을 180분 이내로 수행하였으며, 이 범위 내에서는 인공토양으로부터의 유기화합물 탈착 현상에서 제거효율과 기공부피수, 각각에 로그를 취하였을 때 선형적 특성이 나타났다. 여기에서 기공부피수란 반응기를 통과한 공기의 부피를 기공부피로 나눈 것이다. 세 가지 유기화합물 모두 수분함량이 0%일 때 가장 낮은 제거속도를 보였으며 일정량의 수분이 포함됨으로써 유기화합물 제거에 필요한 기공부피수가 현저히 줄어듦을 관찰할 수 있었다. 또한, 트리클로로에틸렌과 같이 밀도가 큰 유기화합물의 제거를 위해서는 많은 양의 기공부피수가 소요되며 따라서 작업시간이 매우 길어지게 되므로, 토양증기추출법 외에 다른 정화방법을 함께 사용하여야 한다. 또한 인공토양의 특성에 따른 유기화합물의 탈착현상에 대하여 조사하였으며, 미세기공의 유무가 오염물질의 탈착속도에 미치는 영향이 톨루엔과 메틸에틸케톤에서 상이하게 나타났음을 알 수 있었다. 이러한 연구결과는 정화대상지역의 토양특성, 오염물질 등에 대한 조사를 시행한 후 SVE를 이용한 적절한 정화방법을 설계하는데 기초자료로 이용할 수 있을 것이다.

  • PDF

입체 장애 알카놀아민 혼합 수용액에서 중탄산칼륨 결정의 냉각 반용매 결정화 (Cooling and Antisolvent Crystallization of Potassium Bicarbonate in the Presence of Sterically Hindered Alkanolamines)

  • 조창신;정태성;윤형철;김종남;이영우
    • 청정기술
    • /
    • 제20권4호
    • /
    • pp.383-389
    • /
    • 2014
  • 이산화탄소 흡수공정은 대규모의 이산화탄소를 처리하는데 유리하지만, 다량의 흡수액을 재생하는데 필요한 현열과 증발열로 인한 에너지 비용 상승이 단점으로 지적되고 있다. 이를 극복하기 위해 이산화탄소를 흡수한 탄산칼륨 흡수액을 냉각 결정화시켜, 다량의 물로부터 이산화탄소가 많이 포함된 중탄산칼륨 결정을 선택적으로 분리할 수 있다. 본 연구에서는 이산화탄소 분리효율을 높이기 위해 입체 장애 알카놀아민 첨가제를 도입하여, 이들이 중탄산칼륨 연속식 결정화에 미치는 영향에 대해 살펴보았다. 결정의 석출량은 2-아미노-2-메틸-1-프로판올(2-amino-2-methyl-1-propanol, AMP), 2-아미노-2-메틸-1,3-프로판디올(2-amino-2-methyl-1,3-propanediol, AMPD), 2-아미노-2-히드록시메틸-1,3-프로판디올(2-amino-2-hydroxymethyl-1,3-propanediol, AHPD)의 순서로 증가하였으며, 반용매로 작용하는 첨가제들의 히드록실기 개수와 관계가 있는 것으로 나타났다. 탄소 핵자기공명분광 분석 결과, 첨가제들은 입체 장애 효과에 의해 중탄산 이온의 생성을 유도하고 과포화도를 상승시킨 것으로 나타났다. 또한, 첨가제들은 과포화도 상승을 통해 평균 입도와 결정 성장 속도를 증가시키는 것으로 나타났다. 입체 장애 알카놀아민 첨가제는 중탄산칼륨 결정화를 촉진함으로써, 물로부터 이산화탄소의 분리효율을 향상시키고 재생에너지를 저감시킬 수 있을 것으로 기대된다.

라이시미터를 이용한 시설하우스 내에 살포한 농약의 휘산 양상 (Volatilization of Sprayed Pesticides in Greenhouse using a Lysimeter)

  • 김단비;김택겸;권혜영;홍수명;박병준;임성진;이효섭;문병철
    • 농약과학회지
    • /
    • 제20권4호
    • /
    • pp.305-311
    • /
    • 2016
  • 본 연구는 시설하우스에 살포된 농약의 공기 중 시간에 따른 분포 양상을 파악하여 농작업자의 안전성을 확보하기 위한 기초자료로 제공하기위해 수행하였다. 농작물에 많이 사용하는 물리화학적 성질이 다른 농약 10가지 성분을 선정하였으며 라이시미터 밭토양에 살포 후 공기 중으로 휘산된 양상을 720시간 동안 조사하였다. PUF 흡착제와 low volume air sampler를 이용하여 공기 중 농약을 포집한 후 LC-MS/MS를 이용하여 공기 중의 농약을 분석하였다. 720시간 동안 대부분의 농약이 24-48시간 사이에 최대 잔류를 보였다. 증기압이 1 mPa 이상의 농약은 살포 후 120-192시간까지도 공기 중 높은 농도가 지속되는 양상을 보인 반면 증기압이 1 mPa 이하인 경우에는 살포 후 첫 포집 시에 가장 높은 농도를 보이고 그 후로 계속해서 낮아지는 농도를 보였다. 공기 중의 최대 농도는 ethoprophos, diazinon, pendimethalin, chlorpyrifos, alachlor, metolachlor, carbaryl, napropamide, tebuconazole, imidacloprid 순으로 증기압의 높낮음 순서와 거의 일치하여 증기압과 휘산량의 상관관계가 높음을 알 수 있었다.