• 제목/요약/키워드: Vapor recompression refrigeration cycle

검색결과 6건 처리시간 0.018초

액화석유가스 저장탱크로부터 발생하는 증발가스 재액화 공정의 최적화에 대한 연구 (An Optimization Study on the Reliquefaction of Boil-Off Gas from Liquefied Petroleum Gas Storage Tank)

  • 노상균
    • 한국수소및신에너지학회논문집
    • /
    • 제30권5호
    • /
    • pp.395-400
    • /
    • 2019
  • Comparative studies between single- and two-stage refrigeration cycle using propane as a refrigerant have been performed for a vapor recompression refrigeration cycle. PRO/II with PROVISION release 10.2 from AVEVA company was used, and the Soave-Redlich-Kwong equation of state model with Twu's alpha function was selected for the modeling and optimization of the refrigeration cycle for the reliquefaction of BOG coming out from the LPG storage tank. In two-stage refrigeraton cycle, 24.8% of compressor power was reduced compared to that of single-stage refrigeration cycle through the optimization works.

몇 가지 냉매를 사용한 이산화탄소 액화에 대한 비교 연구 (Comparative Research on the Carbon Dioxide Liquefaction Using Several Refrigerants)

  • 박일수;황필성;정기철;안준수;조정호
    • 한국수소및신에너지학회논문집
    • /
    • 제34권2호
    • /
    • pp.226-233
    • /
    • 2023
  • In this study, we compared the performance of several refrigeration cycles using different refrigerants and utilizing the cold heat of liquefied natural gas (LNG) for the liquefaction of carbon dioxide. The final conditions for the liquefied CO2 were set to -20℃ and 20 bar. The refrigerants used included R404a, ammonia, propane, and propylene using a vapor recompression refrigeration cycle. For the refrigeration cycle, the CO2 at room temperature and pressure was compressed in a two-stage compression process with an intermediate cooling stage using a refrigeration unit. To compare with the liquefaction process using refrigeration, we compressed the CO2 to 8 bar in a single compression stage and cooled it to around -50℃ using the cold heat of the LNG before liquefying it. Results showed that using ammonia as the refrigerant required the least amount of compressor power for the liquefaction process, and the heat transfer area of the evaporator was the smallest when using propylene as the refrigerant. Using the cold heat of LNG instead of refrigeration using R404a resulted in approximately 69% less energy consumption.

LNG 냉열을 활용한 이산화탄소 액화공정에서 절감되는 전력량의 산출 (Estimation of the Amount of Electric Power Saved in the Carbon Dioxide Liquefaction Process using LNG Cold Heat)

  • 이지환;조정호
    • 한국수소및신에너지학회논문집
    • /
    • 제31권2호
    • /
    • pp.259-264
    • /
    • 2020
  • In this study, comparison study has been performed between two-stage compression and a vapor-recompression refrigeration cycle and a liquefaction using LNG cold heat. When using a first method using two-stage compression and a refrigeration cycle, at least three compressors are required, however when using LNG cold heat, no compressor is required since carbon dioxide can be pumped after condensing with the heat exchange with -160℃ of LNG. Through this study, we can save more than one hundred million KRW annually by using LNG cold heat instead of using gas compression and refrigeration cycle.

전기식 냉동기에서 냉매의 공급온도에 따른 액화천연가스의 톤당 냉열 가격 산출에 대한 연구 (A Study on the Price Evaluation Per 1 Ton of Liquefied Natural Gas According to the Refrigerants Supply Temperature in the Electric Refrigerator)

  • 김영우;박일수;조정호
    • 한국수소및신에너지학회논문집
    • /
    • 제30권5호
    • /
    • pp.473-477
    • /
    • 2019
  • In this paper, cold heat price contained in the 1 ton/h of LNG has been evaluated using PRO/II with PROVISION release 10.2 from Aveva company when LNG is used to liquefy several refrigerants instead of using vapor recompression refrigeration cycle. Normal butane, R134a, NH3, R22, propane and propylene refrigerants were selected for the modeling of refrigeration cycle. It was concluded that LNG cold heat price was inversely proportional to the refrigerant supply temperature, even though LNG supply flow rate is not varied according to the refrigerant supply temperature.

이산화탄소 액화를 위한 증기 재압축 냉동 공정과 액체질소 냉열을 이용한 냉동 공정의 비교 연구 (Comparative Study on the Refrigeration Processes between Refrigeration Using Vapor Recompression and Refrigeration Using LN2 Cold Heat for the Carbon Dioxide Liquefaction)

  • 노상균
    • 한국수소및신에너지학회논문집
    • /
    • 제34권5호
    • /
    • pp.549-554
    • /
    • 2023
  • In this paper, three kinds of studies have been completed to obtain highly purified carbon dioxide having more than 7N purity as an electronic grade quality. PRO/II with PROVISION release January 2023 from AVEVA company was used, and Peng-Robinson equation of the state model with Twu's alpha function was selected for the modeling of the cryogenic distillation process. When using LN2 cold heat, we can obtain highest recovery of carbon dioxide as a bottom product for a cryogenic distillation column.

심냉 증류를 통한 전자급 고순도 이산화탄소의 분리 공정에 대한 전산 모사 연구 (A Computer Simulation Study on the Separation Process for Electronic Grade, Highly Pure Carbon Dioxide through a Cryogenic Distillation)

  • 박일수;문흥만;조정호
    • 한국수소및신에너지학회논문집
    • /
    • 제34권1호
    • /
    • pp.83-89
    • /
    • 2023
  • In this study, a computer simulation work has been performed for the separation of electronic grade highly pure carbon dioxide more than 7 N purity through a cryogenic distillation process. For the cold utility as a cooling medium for a condenser of the cryogenic distillation column, propylene was utilized as a refrigerant in the vapor-recompression refrigeration cycle. Through this work, it was concluded that the cryogenic distillation column with two stage compression and refrigeration cycle were essential to obtain a highly-pure liquefied CO2.