• 제목/요약/키워드: Vapor compressor

검색결과 92건 처리시간 0.02초

가스인젝션을 적용한 이산화탄소 열펌프의 난방성능 향상에 관한 해석적 연구 (Analytical Study on the Heating Performance Improvement of a CO2 Heat Pump Using Vapor Injection)

  • 정종호;백창현;허재혁;김용찬
    • 설비공학논문집
    • /
    • 제24권11호
    • /
    • pp.767-776
    • /
    • 2012
  • In this study, a simulation model for a $CO_2$ heat pump using vapor injection was developed and validated. It was used to predict the improvement of the heating performance of the $CO_2$ heat pump at various operating conditions. The simulation results showed consistent results with the measured data. The heating performances of the vapor injection and non-injection heat pumps were compared by varying the outdoor temperature and compressor frequency. The heating capacity of the vapor injection heat pump was 40% higher than that of the non-injection heat pump at the outdoor temperature of $-8^{\circ}C$. The performance of the vapor injection heat pump was consistently higher than that of the non-injection heat pump even when the compressor frequency was reduced to 35 Hz at the outdoor temperature of $-3^{\circ}C$.

고속다기통 및 회전식 압축기의 체적효율 (A STUDY ON THE VOLUMETRIC EFFICIENCY OF HIGH SPEED MULTI-CYLINDER AND ROTARY COMPRESSOR)

  • 오후규;조권옥
    • 한국수산과학회지
    • /
    • 제12권1호
    • /
    • pp.13-18
    • /
    • 1979
  • Volumetric efficiency is a determining factor for tile measurement of compessor capacity, but it is practically hard to take an accurate measurement of capacity characteritics so that most of users trust the data of makers catalogue. We often realized the discrepancy in their data with actual capacity. This study was attemped to establish the basic data of capacity characteristics of compressor by measuring volumetric efficiency of high speed multi-cylinder compressor and rotary compressor. The volumetric efficiency was calculated based on the quantity of the flow of ammonia vapor and pressure difference in suction state of orifice plate and compressor. The volumetric efficiency of high speed multi-cylinder compressor was $37-61\%$ and that of rotary compressor was $57-82\%$ when compression ratio was in the range of 4-12. The discrepancy in volumetric efficiency at an equal evaporating temperature between the makers catalogue and the measured data was $5.5\%$.

  • PDF

전동 스크롤압축기의 운전rpm에 따른 냉동사이클의 성능에 대한 실험적 연구 (Experimental Study on the Performance of Refrigeration Cycle for various RPM of Inverter Scroll Compressor)

  • 이규선;이근안;이형욱;이영선;김정배
    • 한국태양에너지학회 논문집
    • /
    • 제34권3호
    • /
    • pp.42-48
    • /
    • 2014
  • An experimental study was performed estimating COP(Coefficient of Performance) of air-conditioning cycle with inverter scroll compressor. All experiments were done for various compressor speeds from 1000~4000 rpm and used the inverter controller called CANDy to change the compressor rpm. The air-conditioning cycle components in the apparatus were used as same with components of YF hybrid car. To estimate the COP, this study measured the temperature and pressure at inlets and outlets of compressor, condenser, and evaporator. And also measured the compressor input power using Powermeter. Through the experiments, the maximum error to estimate COP was shown about ${\pm}6.09%$ at 3500rpm. This study revealed that the condenser temperature and pressure were increased and the evaporator temperature and pressure were decreased with the increased compressor speed. And also, the COP was decreased with increased compressor speed. Those results can be used the basic and fundamental data to design the air-conditioning cycle with inverter scroll compressor.

Subcooling Bypass Technology를 적용한 압축기 토출 냉매 온도 감소에 관한 연구 (A Study on the Decrease of Compressor Discharge Temperature Using Subcooling Bypass Technology)

  • 곽경민;배철호
    • 설비공학논문집
    • /
    • 제21권6호
    • /
    • pp.326-332
    • /
    • 2009
  • The purpose of the study is to decrease the refrigerant temperature at the outlet of the compressor under high thermal load conditions for air cooled vapor compression refrigeration system. The subcooling bypass line called subcooling bypass technology(SBT) is installed to the window type A/C system to investigate the performance test. The standard air calorimeter test method is applied to measure the refrigerant temperature at the outlet of the compressor, cooling capacity, power consumption, and system EER. The refrigerant temperature at the outlet of the compressor decreases as the bypass rate increases. When the bypass rate is 8.2%, the refrigerant temperature at the outlet of the compressor decreases $2.8^{\circ}C$ while the cooling capacity and EER are the same as the conventional A/C unit.

에어컨의 고효율화를 위한 용량가변 방식 비교에 관한 연구 (Benchmark Performance Analysis of Vapor Compression System with Capacity Modulation Compressor)

  • 유윤호;황윤제;김철민;조관식
    • 설비공학논문집
    • /
    • 제14권2호
    • /
    • pp.98-107
    • /
    • 2002
  • The performance of a capacity controlled system, which are tandem, pole change, bypass and inverter driven compressor, has been compared with that of a con- ventional constant speed system. It has been found that capacity modulated system can offer more than 14 percent improvement in SEER over the conventional system. Comparative test results show that two compressor system can attain an improvement in SEER up to 42% over the conventional on/off system, and is feasible without additional investment.

열펌프 압축기의 내부 액분사 효과에 대한 수치해석적 연구 (A Numerical Study of Liquid Injection into the Compressor Cylinder of a Heat Pump)

  • 허재경;방광현
    • 설비공학논문집
    • /
    • 제15권5호
    • /
    • pp.397-405
    • /
    • 2003
  • Heat and fluid flow in a compressor into which liquid refrigerant is injected for the purpose of reducing discharge gas temperature in a heat pump system has been numerically studied. A mechanistic approach encompassing liquid jet breakup and droplet evaporation has been performed to investigate the effects of liquid injection on the spacial and temporal variation of the gas temperature and pressure inside the compressor cylinder. Various parameters, such as liquid injection mass, time, duration and droplet size, are considered in the present study to elucidate the flow field inside the compressor. As the injection mass is increased, discharge gas temperature is decreased, while the pressure is increased due to the added mass of the injection. For the injected liquid mass corresponding to 15% of the total vapor mass in the cylinder, the discharge gas temperature drops by 22.4 K. It is observed that the droplet size plays a major role in the evaporation rate of the droplets that determines the degree of the discharge temperature drop.

R-22 대체용 혼합냉매의 열역학적 성능에 대한 실험연구 (An experimental investigation of thermodynamic performance of R-22 alternative blends)

  • 황의필;김창년;박영무
    • 설비공학논문집
    • /
    • 제9권1호
    • /
    • pp.82-91
    • /
    • 1997
  • R-410a and R-407c witch have the best potential among the substances being considered as R-22 alternatives were tested as "drop in" refrigerants against a set R-22 baseline tests for comparison. The performance evaluations were carried out in a psychrometric calorimeter test facility using the residential split-type air conditioner under the ARI rating conditions. Other than the use of different lubricant and a hand-operated expansion valve, one of the commercial systems was selected for the experiment. Performance characteristics were measured; compressor power, capacity, VCR, mass flow rate and COP. The tests showed that R-407c can be directly applied to the existing refrigeration system because of its similar vapor pressure and other thermopysical properties with those of R-22. However, it required change to the volume flow rate of compressor in order to achieve the similar performance with R-22 because of its relatively small VCR and capacity. Meanwhile, R-410a has too high a vapor pressure to be applied to the existing system and this feature results in relatively low COP of the system compared to that of R-22. But this could be improved by changing compressor design considering R-410a's relatively high VCR and capacity compared to those of R-22.

  • PDF

Al2O3 나노 입자를 적용한 증기 압축 냉동 사이클의 성능 (An Experimental Study on Performance of Vapor Compression Refrigeration Cycle with Al2O3 nano-particle)

  • 김정배;이규선;이근안
    • 에너지공학
    • /
    • 제24권4호
    • /
    • pp.124-129
    • /
    • 2015
  • $Al_2O_3$ 나노입자의 농도별로 전동식 압축기의 회전속도(rpm)의 변화에 따른 자동차용 증기압축 냉동사이클의 COP를 실험적으로 평가하고 나노입자를 적용하지 않은 기준 사이클의 COP와 비교하였다. 이를 위해 실제 하이브리드 자동차에서 쓰는 사이클 부품들을 이용하고 항온항습 챔버를 이용하지 않는 방식으로 장치를 설계 및 제작하였다. 별도의 전동식 인버터 압축기의 제어장치를 활용하여 1000rpm부터 500rpm 간격으로 4000rpm까지와 $Al_2O_3$ 나노입자를 질량비 기준으로 농도 0.05%, 0.1%, 0.2%와 0.5%의 범위에 대하여 실험을 수행하였다. 이를 통해 기준 사이클과 비교하면 기준 사이클의 일반적인 운전조건인 약 3000rpm에서 $Al_2O_3$ 나노유체를 적용하는 사이클의 COP는 질량 농도비 0.05%에서는 15.4% 정도, 농도비 0.1%, 0.2% 및 0.5%에서는 각각 9.4%, 13% 및 9.6%가 증가함을 알 수 있었다.

열 증기 압축기 내의 유동해석을 통한 설계 인자들의 영향 분석 (Appraisement of Design Parameters through Fluid Dynamic Analysis in Thermal Vapor Compressor)

  • 박일석;김홍원;김양규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.155-158
    • /
    • 2002
  • In general, TVC(Thermal Vapor Compressor) is used to boost/compress a low pressure vapor to a higher pressure for further utilization. The one-dimensional method is simple and reasonably accurate, but cannot realize the detail as like the back flow and recirculation in the mixing chamber, viscous shear effect, and etc. In this study, the axisymmetric How simulations have been performed to reveal the detailed flow characteristics for the various ejector shapes. The Navier-Stokes and energy equations are solved together with the continuity equation In the compressible flow fields. The standard $k-{\epsilon}$ model is selected for the turbulence modeling. The commercial computational fluid dynamic code FLUENT software is used for the simulation. The results contain the entrainment ratio under the various motive, suction and discharge pressure conditions. The numerical results are compared with the experimental data, and the comparison shows the good agreement. The three different flow regimes (double chocking, single chocking and back flow) have been clearly distinguished according to each boundary pressure values. Also the effects of the various shape variables (nozzle position, nozzle outlet diameter, mixing tube diameter, mixing tube converging angle, and etc.) are quantitatively discussed.

  • PDF

대체냉매 R-32(Difluoromethane)의 열역학적 물성과 R-22 대체냉매로서 열역학적 성능의 초기 평가 (Thermodynamic Properties of R-32(Difluoromethane) and Initial Evaluation of Thermodynamic Perfomance as A R-22 Alternative Refrigerant)

  • 박영무
    • 설비공학논문집
    • /
    • 제5권2호
    • /
    • pp.141-155
    • /
    • 1993
  • Thermodynamic properties of R-32 are calculated and its refrigeration performance is evaluated for the purpose the feasibility study of replacing R-22 with R-32. (1) Refrigeration effect of R-32 is superior to that of R-22 because heat of evaporation of R 32 is about 50% higher than that of R-22. However, COP of R-32 system is 10-30% lower than that of R-22 system. It is mainly attributed to the vapor pressore of R-32 being about 62% higher than R-22. (2) Since the pressure ratio and the specific heat ratio of R-32 system is higher than those of R -22, compressor discharging temperature rises as high as to $130-150^{\circ}C$. It may cause mechanical failure of compressor due to the breakdown of lubricant. Compressor should be improved to lower the temperature if R-32 is to replace R-22. (3) Averaged two-phase heat transfer coefficient of R-32 is about 10-20% higher than that of R-22. It may assume better heat exchanger effectiveness but not guarantee the better COP of R-32 system than R-22. (4) The high vapor pressure is the first reason to drop R-32 out of the line of R-22 alternative refrigerant. So, refrigerant mixtures based on R-32 are recommended to adjust the vapor pressure first and keep superior volumetric capacity of R-32.

  • PDF