• 제목/요약/키워드: Vane Method

검색결과 186건 처리시간 0.025초

Study on the mixing performance of mixing vane grids and mixing coefficient by CFD and subchannel analysis code in a 5×5 rod bundle

  • Bin Han ;Xiaoliang Zhu;Bao-Wen Yang;Aiguo Liu;Yanyan Xi ;Lei Liu ;Shenghui Liu;Junlin Huang
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3775-3786
    • /
    • 2023
  • Mixing Vane Grid (MVG) is one of the most important structures in fuel assembly due to its high performance in mixing the coolant and ultimately increasing Critical Heat Flux (CHF), which avoids the temperature rising suddenly of fuel rods. To evaluate the mixing performance of the MVG, a Total Diffusion Coefficient (TDC) mixing coefficient is defined in the subchannel analysis code. Conventionally, the TDC of the spacer grid is obtained from the combination of experiments and subchannel analysis. However, the processing of obtaining and determine a reasonable TDC is much challenging, it is affected by boundary conditions and MVG geometries. In is difficult to perform all the large and costing rod bundle tests. In this paper, the CFD method was applied in TDC analysis. A typical 5 × 5 MVG was simulated and validated to estimate the mixing performance of the MVG. The subchannel code was used to calculate the TDC. Firstly, the CFD method was validated from the aspect of pressure drop and lateral temperature distribution in the subchannels. Then the effect of boundary conditions including the inlet temperature, inlet velocities, heat flux ratio between hot and cold rods and the arrangement of hot and cold rods on MVG mixing and TDC were studied. The geometric effects on mixing are also carried out in this paper. The effect of vane pattern on mixing was investigated to determine which one is the best to represent the grid's mixing performance.

양산지역 점토의 비배수 전단강도 특성 (Characteristics of Undrained Shear Strength of Yangsan Clay)

  • 김길수;임형덕;이우진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 연약지반처리위원회 학술세미나
    • /
    • pp.71-78
    • /
    • 2000
  • SHANSEP method involves the consolidation to stresses in excess of the preconsolidation pressure in order to overcome sample disturbance effect. The concept of SHANSEP is based on an approach to laboratory test which attempts to reproduce the in-situ conditions more closely than is possible in routine tests and evaluates normalized strength parameters for the soil as a function of OCR. But SHANSEP method can be applied only to fairly uniform clay deposits, and is unsuitable for a random deposit. In this study, CK/sub o/U triaxial compression test and incremental loading consolidation test were performed for the application of SHANSEP method on Yangsan clay. During the K/sub o/-consolidation, triaxial specimens were consolidated to stress equal to two times the in-situ vertical effective stress. And for overconsolidated condition, the specimens were swelled to a known vertical effective stress in order to have the desired OCR. With the results of CK/sub o/U triaxial compression test using the block samples, the relationship between c/sub u//σ/sub vc/' and OCR on Yangsan clay was established. For evaluating the undrained shear strength of Yangsan clay with depth, CK/sub o/U triaxial compression test was performed using the piston samples taken from Yangsan site. And also undrained shear strength was analyzed from the in-situ test such as Cone Penetration Test(CPT), Dilatometer Test(DMT), and Field Vane Test(FVT) and was compared with that of CK/sub o/U triaxial compression test.

  • PDF

EFFECTS OF GRID SPACER WITH MIXING VANE ON ENTRAINMENTS AND DEPOSITIONS IN TWO-PHASE ANNULAR FLOWS

  • KAWAHARA, AKIMARO;SADATOMI, MICHIO;IMAMURA, SHOGO;SHIMOHARAI, YUTA;HIRAKATA, YUDAI;ENDO, MASATO
    • Nuclear Engineering and Technology
    • /
    • 제47권4호
    • /
    • pp.389-397
    • /
    • 2015
  • The effects of mixing vanes (MVs) attached to a grid spacer on the characteristics of air-water annular flows were experimentally investigated. To know the effects, a grid spacer with or without MV was inserted in a vertical circular pipe of 16-mm internal diameter. For three cases (i.e., no spacer, spacer without MV, and spacer with MV), the liquid film thickness, liquid entrainment fraction, and deposition rate were measured by the constant current method, single liquid film extraction method, and double liquid film extraction method, respectively. The MVs significantly promote the re-deposition of liquid droplets in the gas core flow into the liquid film on the channel walls. The deposition mass transfer coefficient is three times higher for the spacer with MV than for the spacer without MV, even for cases 0.3-m downstream from the spacer. The liquid film thickness becomes thicker upstream and downstream for the spacer with MV, compared with the thickness for the spacer without MV and for the case with no spacer.

Diagnostics of nuclear reactor coolant pump in transition process on performance and vortex dynamics under station blackout accident

  • Ye, Daoxing;Lai, Xide;Luo, Yimin;Liu, Anlin
    • Nuclear Engineering and Technology
    • /
    • 제52권10호
    • /
    • pp.2183-2195
    • /
    • 2020
  • A mathematical model for the flowrate and rotation speed of RCP during idling was established. The numerical calculation method and dimensionless method were used to analyze the flow, head, torque and pressure and speed changes under idle conditions. Regularity, using the Q criterion vortex identification judgment method combined with surface flow spectrum morphology analysis to diagnose the vortex dynamic characteristics on RCP blade. On impeller blade, there is two oscillations in the pressure ratio on pressure surface in blade outlet region. The velocity on the suction surface is two times more oscillating than the inlet of blade, and there is an intersection with the velocity ratio curve on pressure surface. On blade of guide vane, the pressure ratio increases along the inlet to outlet direction, and the speed ratio decreases with the increase of idle time. There is a vortex that rotates counterclockwise on the suction surface, and the streamline on the suction surface of blade is subjected to the entrainment and blocking action of the vortex creates a large reverse flow in the main flow region. There are two vortices at the outlet of guide vane suction side and the vortices are in opposite directions.

Aerodynamic Damping Analysis of a Vane-type Multi-Function Air Data Probe

  • Lee, Yung-Gyo;Park, Young-Min
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제14권1호
    • /
    • pp.99-104
    • /
    • 2013
  • Configuration design, analysis, and wind tunnel test of a vane-type multi-function air data probe (MFP) was described. First, numerical analysis was conducted for the initial configuration of the MFP in order to investigate aerodynamic characteristics. Then, the design was modified to improve static and dynamic stability for better response characteristics. The modified configuration design was verified through wind tunnel tests. The test results are also used to verify the accuracy of the analytical method. The analytically estimated aerodynamic damping provided by the Navier-Stokes equation solver correlated well with the wind tunnel test results. According to the calculation, the damping coefficient estimated from ramp motion analysis yielded a better correlation with the wind tunnel test than pitch oscillation analysis.

CFD을 이용한 프란시스 수차의 내부유동 해석 (Performance Analysis of Francis Turbines by CFD)

  • 최현준;황영철;김유택;남청도;이영호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.191.2-191.2
    • /
    • 2010
  • The conventional method to assess turbine performance is its model testing which becomes costly and time consuming for several design alternatives in design optimization. Computational fluid dynamics (CFD) has become a cost effective tool for predicting detailed flow information in turbine space to enable the selection of best design. In the present paper, Francis turbine of commercial small hydropower plants which is under 70kw is investigated. Solutions are investigated with respect to the hydraulic characteristics against an outward angle of guide vane, the number of guide vane and head (inlet velocity). By suitable modification of the runner shape, low pressure zone on the leading edge can be reduced. If the entire runner is to be optimized in this manner, flow simulation tests have to be carried out on a series of different geometrical shape.

  • PDF

전부하시 희박영역에서의 천연가스엔진 성능향상에 관한 연구 (A Study on the Performance Improvement for a Natural Gas Engine under Lean Burn & WOT Condition)

  • 김창업;김창기;김승수;방효선;한정옥;조양수
    • 한국자동차공학회논문집
    • /
    • 제4권6호
    • /
    • pp.11-17
    • /
    • 1996
  • Many researches on natural gas engines, with lean mixtures are being conducted for the purpose of preservation of global environment. Lean combustion is one of the most promising method for increasing engine efficiency and reducing the emission from SI engines. Due to the possibility of partial burn and misfire, however, under lean burn operation, stable flame kernel formation and fast burn rate, by use of swirl or tumble flow, are needed to guarantee a successful subsequent combustion. Experimental data were obtained on a 4-stroke, natural gas fueled SI engine to investigate the effect of compression ratio, swirl and spark plug electrode rotation on efficiency and emission under lean burn condition. Experimental results have displayed that higher compression ratio, presence of swirl vane and favorable direction of electrode gap brougth about the improvements in engine efficiency and its operational stability.

  • PDF

터보팬엔진의 터보팬과 파일론 유동장 간섭에 관한 수치적 연구 (Turbofan and Pylon Flowfields Interaction in Turbofan Engines)

  • 주원구
    • 대한기계학회논문집B
    • /
    • 제22권8호
    • /
    • pp.1164-1172
    • /
    • 1998
  • The three dimensional numerical method using actuator disk blade row model is applied for calculating the flowfield interaction between an outlet guide vane (OGV) and a pylon in a typical civil turbofan engine. The static pressure distortion produced by the pylon is decaying upstream but is still felt at the turbofan exit, and hence can significantly affect the fan performance. The OGV amplifies the static pressure perturbation decaying upstream. The calculation results show that cyclic OGV which consists of three types of blades with different exit angles can reduce more than half of the asymmetries of total pressure and static pressure propagated through the OGV with uniform exit blade angle.

제트팬 노즐내부 유동에 대한 고정익 출구 원주속도의 영향 (Effect of Circumferential Velocity from Guide Vane on the Nozzle Flow of a Jet Fan)

  • 최충현;이재헌
    • 설비공학논문집
    • /
    • 제13권3호
    • /
    • pp.209-216
    • /
    • 2001
  • A numerical study is peformed to investigate the effect of circumferential velocity generated by the guide vane on the nozzle flow of a jet fan, s a way of increasing the penetration force of jet fan with nozzle of 175mm diameter. For the validation of numerical results. the velocity is measured by a 5-hole pitot tube and flow visualization is conducted by the tuft method. Under the inlet condition that the maximum circumferential velocity in the stator outlet of the present jet fan is 1.8m/s, the axial velocity in the nozzle outlet has the feature that the velocity at the axis is low and the velocity near the wall high. Therefore, to increase the throw length of the jet fan, the configuration of the fairing and nozzle needs to be developed and the precise revise of the stator angle is required, In addition, the bigger the circumferential velocity, the smaller the axial velocity at the axis and the bigger non-uniformity of the flow distribution.

  • PDF

치과 치료기기용 에어모터 핸드피스의 출구 다공망에 대한 수치 해석적 연구 (A NUMERICAL STUDY OF VANE TYPE DENTAL AIR-MOTOR WITH 7MINI HOLE OF AIR-OUTLETS)

  • 김재욱;김성래;류경진;송동주
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.529-534
    • /
    • 2011
  • The air-motor unit of the hand-piece had not been developed inside of the country yet. Therefore it needs some research works. The objective of this study is to investigate the effect of the many mini holes at the outle of the air-motort. The flow fields analysis has been conducted by the immersed solid method using ANSYS 12.0 CFX.

  • PDF