• 제목/요약/키워드: Vane Control

검색결과 108건 처리시간 0.029초

천장형 실내기의 기류 가시화를 통한 최적 제어 설계 (Design of Optimal Vane Control for Ceiling Type Indoor Unit by PIV measurements)

  • 성재용;안광엽;이기섭;최호선;박승철;이인섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.533-536
    • /
    • 2002
  • A heating flow discharged from a 4-way ceiling type indoor unit has been investigated using a PIV(particle image velocimetry) system For the PIV measurements, an experimental model of 1/10 scale with a transparent room was devised by satisfying the Archimedes number, which is generally used in case that the forced convection has the similar magnitude as the natural convection. To optimize the heating flow, several vane angles and vane control algorithms of cross and right angle controls were considered. Regarding the vane angle, the experimental results show that it should be less than $30^{\circ}$ to avoid re-suction flows which decrease the performance of the air-conditioner. At the vane angle of $30^{\circ}$, applying open/close control gives nae to more uniform distribution of the heating flow than without control. Especially, the cross-control seems to be satisfactory for the thermal comfort.

  • PDF

베인펌프 설계를 위한 베인 선단부의 작용력에 관한 연구 (A Study on the Acting Load in the Vane Tip of Vane Pump for Design)

  • 정석훈
    • Tribology and Lubricants
    • /
    • 제19권6호
    • /
    • pp.370-375
    • /
    • 2003
  • The radial acting load of vane on the camring in oil hydraulic vane pumps with and without intra­vanes have been investigated. The influences of the discharge pressure and rotating speed of the vane to the load were discussed. The variations of the radial acting load of a vane were calculated on the basis of the results measured for the dynamic internal pressure in the four chambers surrounding a vane. It provides essential information for the study of pump dynamics and control, the pump design and the analysis of tribological problems in the sliding components.

추력방향조종용 제트베인의 3차원 온도분포 해석 (An Analysis on 3-Dimensional Temperature Distribution of Jet Vanes for a Thrust Vector Control)

  • 황기영
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.283-291
    • /
    • 2011
  • 수직발사 추진기관의 추력방향조종(TVC)용으로 사용되는 제트베인 조립체의 열전달 특성을 고찰하기 위해 수치해석을 수행하였다. 본 연구에서 제트베인 주위의 대류열전달계수는 열경계층 방정식의 해와 반실험식을 사용하여 구하였다. 제트베인 조립체의 3차원 온도분포에 대한 해석은 PATRAN과 ABAQUS 소프트웨어를 사용하여 수행되었다. 본 수치해석 기법의 타당성은 제트베인 축 내부에서 측정한 온도와 열해석 결과의 비교를 통해 검증하였다. 제트베인의 3개 편향각(0o, 12.5o, 25o)에 대해 연소시간별 제트베인의 온도변화를 고찰하였다.

  • PDF

Shroud를 포함한 제트베인의 공기역학적 특성 연구 (A study on aerodynamic characteristics of jet-vane thrust vector control system enclosed by a shroud)

  • 박순종;김경련;박종호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3203-3208
    • /
    • 2007
  • The performance study shows the result using two different methods which are used to control missile or aircraft. One is the Thrust Vector Control(TVC) method for the aviation of next generation and the other is the present effective Shroud Jet-vane System(SJVS) method for the satellite effector development. The research was done through the performance estimation using the numerical simulation analysis, the modelling, the performance measuring using the model, the investigation of the flow visualization and aerodynamic performance with the enforced power to the vane and the result comparison.

  • PDF

FD FAN에서 기어식 베인 댐퍼의 성능개선에 관한 연구 - 생산 및 구조 융합형 기술 - (A Study on Performance Improvement of Gear Type Vane Damper in FD Fan - Productivity Increases & Construction Improvement -)

  • 장성철;한상호;김진우
    • 한국생산제조학회지
    • /
    • 제19권1호
    • /
    • pp.134-139
    • /
    • 2010
  • In this study, we developed the gear type vane damper replacing the link type through gear design using Finite Element Analysis(FEA). FEA about the pinion and the vane shaft in the boss of gear type damper for quality improvement was accomplished. We analyzed fluid flow according to angular displacement. Catched the problem of the torque and backlash bring to the pinion as structure improvement of the forced draft fan(FD FAN). Finally, we compared the gear driving result with simulation. It is the objective of the present study to identify a nonlinear flow rate control of gear type vane damper and to suggest a damper shape with a linear flow rate control. This study is related to the development of gear type vane damper change link type in forced draft fan.

Helical Vane 을 이용한 펄스파의 피동제어 (Passive Control of the Impulse Wave Using a Helical Vane)

  • 양수영;이동훈;김희동;뢰호구준명
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.792-797
    • /
    • 2003
  • A helical vane is applied to reduce the magnitude of the impulse wave discharged from the exit of a duct. A shock tube with an open end is used to investigate the effect of the helical vanes on the impulse wave magnitude. Four different types of helical vanes are installed into the low-pressure tube of shock tube. The magnitude of the incident shock wave is varied below 1.25, and the magnitude of impulse wave is measured using a pressure transducer mounted on a wedge probe. Instant images of the impulse wave are obtained by means of the Schlieren optical method. The present experimental results show that the helical vane considerably reduces the magnitude of the impulse wave and the vane effects are more remarkable for stronger incident shock wave.

  • PDF

더블 베인 회전형 유압 구동시스템의 임피던스 제어를 위한 토크 서보 설계 (Design of Torque Servo for Impedance Control of Double Vane Rotary Hydraulic Actuator System)

  • 김선민;최영진;정완균
    • 로봇학회논문지
    • /
    • 제5권2호
    • /
    • pp.160-168
    • /
    • 2010
  • In order to achieve a force controller with high performance, an accurate torque servo is required. However, the precise torque servo for a double vane rotary actuator system has not been developed till now, due to many nonlinear characteristics and system parameter variations. In this paper, the torque servo structure for the double vane rotary actuator system is proposed based on the torque model. Nonlinear equations are set up using dynamics of the double vane rotary hydraulic actuator system. Then, to derive the torque model, the nonlinear equations are linearized using a taylor series expansion. Both effectiveness and performance of the design of torque servo are verified by torque servo experiments and applying the suggested torque model to an impedance controller.

산업용 유량제어 송풍기 베인댐퍼 개발에 관한 연구 (A Study on Development of Vane Damper for Industry Flow Control Fan)

  • 이중섭;정인국;윤지훈;서정세;장성철
    • 한국생산제조학회지
    • /
    • 제21권1호
    • /
    • pp.137-143
    • /
    • 2012
  • In this study, it was conducted to design each components of vane damper for industrial flow control fan and the flow rates were analysed by experimental and numerical method. Through environmental test, it could be confirmed that the designed vane damper was appropriate. Also, almost identical results with test could be drawn from numerical method. Finally, flow rates of electric and pneumatic actuator were measured by test. As the results, difference of flow rate according to opening ratio was smaller in pneumatic actuator than that in electric actuator.

유압 베인 펌프에서의 탄성유체윤활 해석 (Elastohydrodynamic Lubrication Analysis in Hydraulic Vane Pump)

  • 박태조
    • 드라이브 ㆍ 컨트롤
    • /
    • 제10권3호
    • /
    • pp.7-13
    • /
    • 2013
  • Hydraulic vane pumps are widely used in various hydraulic systems because of its compactness and light weight. It is well known that the vanes and cam ring are separated by very thin liquid films which result in the EHL state. Contrary to the case of cylindrical roller bearings, the inlet and side boundary pressures are much higher than the atmospheric pressure. In this paper, a numerical solution of the EHL of finite line contacts between the cam ring and vane tip with profiled ends is presented. Using a finite difference method with non-uniform grids and the Newton-Raphson method, converged solutions are obtained for moderate load and material parameters. The EHL pressure distribution and film shape are considerably affected by pump delivery pressure and the side boundary condition applied. Both the maximum pressure and the minimum film thickness always occurred near the edge regions. The present results can be used in the design of optimum vane profile in hydraulic vane pump.

PIV 유동 계측을 통한 천장형 실내기의 최적 제어 설계 (Optimal Flow Control of Ceiling Type Indoor Unit by PIV Measurements)

  • 성재용;안광협;이기섭;최호선;이인섭
    • 대한기계학회논문집B
    • /
    • 제27권8호
    • /
    • pp.1042-1050
    • /
    • 2003
  • A heating flow discharged from a 4-way ceiling type indoor unit has been investigated to determine the design parameters for the optimal flow control. The flow was measured by a PIV(particle image velocimetry) system and an experimental model of 1/10 scale with a transparent room was devised by satisfying the Archimedes number. This similarity is generally used in cases where the forced convection has similar magnitude of the natural convection. To optimize the heating flow, several vane angles and vane control algorithms of cross and right angle controls were considered. Regarding the vane angle, experimental results show that 30$^{\circ}$is an optimal angle to avoid re-suction flows without significant increase in flow noise. Temperature distribution measured in the environmental chamber ensures the increased thermal comfort when compared to the case, 60$^{\circ}$angle. At the optimal angle, applying open/close control gives rise to more uniform distribution of the heating flow than without control. Especially, the cross-control seems to be satisfactory for thermal comfort.