• Title/Summary/Keyword: Van Test

Search Result 301, Processing Time 0.034 seconds

Design of a Winch Lift for a Scooter to Get On and Off a Coach Van (스쿠터 승하차를 위한 밴승합차용 윈치 리프트 설계)

  • Lee Dug-Young;Youn Jae-Woong;Lee Soo Cheol;Lim Goo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.5 s.170
    • /
    • pp.189-196
    • /
    • 2005
  • The numbers of the elder are rapidly growing who wants to enhance social activities, because Korea is already an aging society since 2000. The mobility and accessibility are the key issues to enhance them. The electric motor scooter and the power wheel chair are efficient movable means at a short range. It would be needed to get on and off them if the elder wants use them after arriving a long distant destination. But the electric scooter is too heavy for a man to get on and off a coach van. The motor winch lift is developed for the elder and the handicapped to get on and off a van easily. The lift consists of 3-linkage which can be installed in a trunk of a van with a small space. The clearance and stress of each component are checked by a computer simulation. The prototype was made. and the performances of safety and comfortableness were verified by operational ability test and durability test.

The Relationship between Pre-service Teachers' Geometric Reasoning and their van Hiele Levels in a Geometer's Sketchpad Environment

  • LEE, Mi Yeon
    • Research in Mathematical Education
    • /
    • v.19 no.4
    • /
    • pp.229-245
    • /
    • 2015
  • In this study, I investigated how pre-service teachers (PSTs) proved three geometric problems by using Geometer's SketchPad (GSP) software. Based on observations in class and results from a test of geometric reasoning, eight PSTs were sorted into four of the five van Hiele levels of geometric reasoning, which were then used to predict the PSTs' levels of reasoning on three tasks involving proofs using GSP. Findings suggested that the ways the PSTs justified their geometric reasoning across the three questions demonstrated their different uses of GSP depending on their van Hiele levels. These findings also led to the insight that the notion of "proof" had somewhat different meanings for students at different van Hiele levels of thought. Implications for the effective integration of technology into pre-service teacher education programs are discussed.

DC and AC Characterization of Metals Conductivity using the van der Pauw Measurement Method (Van der Pauw 측정법을 이용한 금속 도전율의 직류와 교류특성)

  • Kang, Jeon-Hong;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.4
    • /
    • pp.157-160
    • /
    • 2007
  • The van der Pauw technique is one of the popular methods for determining the conductivity of flat metal samples. Traceability of the national standard for the conductivity has been achieved by direct current measurement techniques in national measurement institutes of many countries. But recently, alternative current measurement techniques for determining the conductivity of flat metal samples is also interested. In this study, we measured the conductivity of non-ferrous and ferrous flat metals at alternative current using van der Pauw technique. As measurement results, the conductivities of the samples were decreased according to increasing the test frequency even though the decreasing ratio was different.

4S-Van Design for Application Environment

  • Lee, Seung-Yong;Kim, Seong-Baek;Lee, Jong-Hun
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.106-110
    • /
    • 2002
  • 4S-Van is being developed in order to provide the spatial data rapidly and accurately. 4S-Van technique is a system for spatial data construction that is heart of 4S technique. Architecture of 4S-Van system consists of hardware integration part and post-processing part. Hardware part has GPS, INS, color CCD, camera, B/W CCD camera, infrared rays camera, and laser. Software part has GPS/INS integration algorithm, coordinate conversion, lens correction, camera orientation correction, and three dimension position production. In this paper, we suggest that adequate 4S-Van design is needed according to application environment from various test results.

  • PDF

Analysis of Soil Moisture Changes in Reclaimed Tideland Using Van Genuchten Model (Van Genuchten 모델을 활용한 간척지의 토양수분변화 분석)

  • Ko, Dae-Hee;Son, Jae-Gwon;Lee, Gi-Sung;Kim, Jeong-Kyun;Song, Jae-Do;Park, Young-Jun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.4
    • /
    • pp.53-61
    • /
    • 2020
  • The laboratory model test was conducted by dividing domestic reclaimed tideland into Sandy Loam (SL) and Silt Clay Loam (SiCL) to estimate soil moisture change and water supply according to soil characteristic when establishing irrigation plan for reclaimed tideland upland crop. In addition, the applicability of each scenario was verified using Van Genuchten model, which is the most widely used mathematical model for analyzing soil moisture characteristics of reclaimed tideland uplands crops. The required water supply according to the target soil moisture tension by reclaimed tideland is as follow. In the case of SL, soil depths of 0~10 cm, 10~20 cm were analyzed as 19 mm, 35 mm to reach the field capacity, and SiCL, 33 mm, 63 mm. The required water supply of SiCL was higher than that of SL. The study compared the simulation results from the scenarios of Van Genuchen model and the measured results from the laboratory model test based on according to the reclaimed tidelands. In the case of parameter, θs, θr, α, η were analyzed 0.55, 0.18, 0.064, 1.74 in SL and 0.46, 0.22, 0.105, 1.92 in SiCL. In terms of soil characteristics, SL with better water permeability was found to have higher applicability than SiCL. By Soil depth, applicability was found in 0~10 cm directly affected by water supply.

Unsaturated Hydraulic Conductivity Functions of van Genuchten's and Campbell's models Tested by One-step Outflow Method through Tempe Pressure Cell (empe 압력셀에서 1-단계 유출법을 이용한 van Genchten모형과 Campbell모형의 불포화수리전도도 추정 검증)

  • Han, Kyung-Hwa;Ro, Hee-Myong;Cho, Hyun-Jun;Kim, Lee-Yul;Hwang, Seon-Woong;Cho, Hee-Rae;Song, Kwan-Cheol
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.41 no.4
    • /
    • pp.273-278
    • /
    • 2008
  • This study was carried out in order to test unsaturated hydraulic conductivity estimation of van Genuchten's and Campbell's models using one-step outflow method through Tempe pressure cell. The undisturbed soil cores (columns) were taken from Ap1, B1 and C horizons of Songjeong series (the fine loamy, mesic family of Typic Hapludults). After the saturated hydraulic conductivity Ks of the cores was determined by constant head method, water outflow rate and retentivity of cores were measured in Tempe pressure cell. Fitted curves by models accorded to measured data except for both end of pressure range. In near-saturated condition, measured water retention characteristics showed a relatively better fitness with Campbell's model than van Genuchten's. The soil unsaturated conductivity estimated by Campbell's model was higher than by van Genuchten's. In Ap1 and B1 horizon, the soil unsaturated conductivities obtained by one-step outflow method went between van Genuchten's and Campbell's hydraulic functions, slightly closer to van Genuchten's. In C horizon, van Genuchten's model had better fitness with the one-step outflow data. Consequently, van Genuchten's model generally had better fitness with measured hydraulic conductivity than Campbell's model at the soil water potential range of -10~-75 kPa, especially in C1 horizon. In near-saturated condition, Campbell's model could be thought as relatively accurate hydraulic model, because of the better fitness of Campbell's model with soil water retention data than van Genuchten's model.

Distribution of Vancomycin-resistant Enterococci Isolates Using a ChromID VRE Agar

  • Lee, Hyun;Yoon, In-Seon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.45 no.1
    • /
    • pp.1-4
    • /
    • 2013
  • Vancomycin-resistant enterococci (VRE) have emerged as important healthcare-associated infection since last two decades. ChromID VRE agar (cIDVA) is useful for VRE rectal swab screening. We investigated all VRE were isolated on the cIDVA. A total of 363 rectal swabs of 85 patients to test VRE screening were inoculated into bile-esculin (B-E) broth with $6{\mu}g/mL$ vancomycin. After 24 hours incubation, we subcultured B-E broths were changed to black onto cIDVA. All isolates were identified by the MICROSCAN and VITEK2. The vanA gene and vancomycin minimal inhibition concentration (MIC) were detected by PCR and E-test respectively. 277 E. faecium (84.7%), 16 E. faecalis (4.9%), 25 E. avium (7.6%), 8 E. gallinarum (2.4%) and 1 E. raffinosus (0.3%) were isolated. 10.3% of VRE detected on cIDVA were other than E. faecium and E. faecalis that presented various color from colorless to pale violet. All isolates contained vanA and vancomycin MIC were > $256{\mu}g/mL$. VRE isolates other than E. faecium and E. faecalis should be objective to the contact precautions for healthcare-associated infection control if they possess vanA gene. Due to emerging enterococci carrying vanA such as E. avium, E. gallinarum, and E. raffinosus, VRE surveillance should be expanded to all isolates on chromogenic agar.

  • PDF

Liquid Level System Realizing Van de Vusse Reactor Dynamics and its Control Experiments (Van de Vusse 반응기 동특성을 구현하는 액위시스템 및 제어 실험)

  • Lee, Jietae
    • Korean Chemical Engineering Research
    • /
    • v.58 no.2
    • /
    • pp.184-189
    • /
    • 2020
  • Van de Vusse reactors show the maximum points in input-output steady state maps and dramatic changes in their dynamic characteristics around those maximum points. According to their operating regions, there appear sign changes in steady state gains and nonlinear characteristics such as non-minimum phase dynamics which cause difficulties in applying controllers. Many nonlinear controllers that are available and newly designed are applied to these Van de Vusse reactor processes and their performances are tested. Reactor examples with real reactions have been reported. However, due to difficulties in constructing and operating chemical reactor systems, they are not adequate to be used for real applications of control experiments and hence most of results are based on simulations studies. Here, we propose a liquid level system that realizes most of the steady state and dynamic characteristics of Van de Vusse reactor, and two nonlinear control methods that can be used as base methods to compare nonlinear controllers newly designed. Liquid level experimental system and two nonlinear control methods are very simple and can be used to test performances of nonlinear controllers in practice.

Van Test for GAK NM (GPS Adapter Kit Navigation Module) Using High Performance INS (고정밀 INS를 이용한 GAK(GPS Adapter Kit) 항법 모듈의 차량 시험)

  • Oh, Sang-Heon;Son, Seok-Bo;Kwon, Seung-Bok;Shin, Don-Ho;Lee, Sang-Jeong;Park, Chan-Sik;Hwang, Dong-Hwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.3
    • /
    • pp.260-267
    • /
    • 2007
  • GPS adapter kit (GAK) is a GPS/INS guided range extension system to improve the accuracy and availability of existing dumb bombs. In this paper, a van test result of GPS/INS navigation module (NM) for guided bomb with GAK has been presented. The NM consists of a commercial MEMS IMU, embedded GPS receiver and navigation computer unit (NCU). The GPS receiver of NM was designed to use multiple antennas for satellite visibility and GPS attitude determination. The real-time navigation software was designed by modularized structure to guarantee the maintainability and extensibility. In order to evaluate the performance of the NM, a van test was preformed by using a high performance INS - Honeywell H-726 MAPS(Modular Azimuth Position System).The van test results show that the GAK NM with GPS attitude measurement gives better navigation performance than a conventional GPS/INS integration and good coasting capabilities under jamming environment.

Detection of Vancomycin-Resistant Enterococci and Related Genes Using VITEK 2 System and Multiplex Real-time PCR Assay (VITEK 2 시스템과 Multiplex Real-time PCR을 이용한 반코마이신 내성 장알균(VRE)과 내성관련 유전자 검출)

  • Jeong, Min-Kyung;Yu, Young-Bin;Kim, Sang-Ha;Kim, Sunghyun;Kim, Young-Kwon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.401-406
    • /
    • 2017
  • In this study, using the VITEK 2 system, 74 samples (22.6%) out of 327 specimens were identified by the growth of Enterococcosel media (EV6 agar) supplemented with $6{\mu}g/mL$ of vancomycin. Enterococcus faecium was identified as 55 strains (74.3%), Enterococcus casseliflavus as 2 strains (2.7%), Enterococcus avium as 1 strain (1.4%), and Enterococcus gallinarum as 16 strains (21.6%). Among the 55 phenotypes of Enterococcus faecium, 42 (76.4%), 9 (16.4%), and 4 strains (7.3%) showed the vanA, vanB, and vanC phenotype, respectively. The 16 strains of Enterococcus gallinarum and 2 strains of Enterococcus casseliflavus showed the vanC phenotype and the 1 strain of Enterococcus avium had the vanB phenotype. The one strain of Enterococcus faecium propagated only in EV4 and was susceptible to both vancomycin and teicoplanin according to the antimicrobial susceptibility test using the VITEK 2 system. The vancomycin resistance phenotype gene was not detected by PCR. A total of 327 specimens were cultured in Enterococcosel broth supplemented with $6{\mu}g/mL$ of vancomycin (EV6 broth), and 120 strains (36.7%) were isolated. These 120 strains were subjected to vancomycin resistant genotyping by a multiplex real-time polymerase chain reaction and 51 strains (42.5%) showed vanA; 5 strains (4.2%) showed vanA and vanC; and 18 strains (15%) showed vanC. Vancomycin resistance genotypes were not detected in the remaining 46 strains (38.3%).