• 제목/요약/키워드: Valve-point

검색결과 225건 처리시간 0.023초

데드밴드 제어밸브를 가진 제어루프의 제어 개선 (Control Improvement of Control Loop with Deadband Control Valve)

  • 이광대;오응세;양승옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.318-320
    • /
    • 2006
  • A control valve with deadband characteristics influences on the control dynamics. A control loop with deadband component shows cyclic control results and causes the wears of mechanical parts. A valve on the important process that require nonstop operation cannot be improved during operation. In case of control loops with deadband dynamics, the optimal control parameters based on the performance only are not sure of the good operation in point of protecting the control component. To improve the control performance and control oscillation, the control parameters should be changed to meet both control qualify and protection of control components.

  • PDF

특발성 낭포성 중층 괴사 -1례 보고- (Idiopathic Cystic Medial Necrosis -A Case Report-)

  • 장병철
    • Journal of Chest Surgery
    • /
    • 제12권3호
    • /
    • pp.183-190
    • /
    • 1979
  • A 23-year-old male patient complained dyspnea on exertion and orthopnea since December 1977. On examination, he was tall and slender. There was grade IV/VI to-and-fro murmur on the left sternal border especially on Erb`s point. The liver was descended 2 fingers breadth below right costal margin. There were no signs of Marfan`s syndrome. Echocardiography demonstrated partial closure of aortic valve and dilated aortic root with enlargement of ascending aorta. Left heart cardiac catheterization revealed moderately elevated pulmonary wedge pressure and right ventricular pressure. The left ventricular end diastolic pressure was markedly elevated to 26 mmHg. On aortography, the aortic regurgitation was severe and it was belonged to angiographically Grade IV. The aortic valve was replaced with Carpentier-Edwards valve without excision and replacement of ascending aorta, under the impression of rheumatic valvular heart disease. After closure of aortotomy, blood pressure was transiently elevated and bleeding from the site of inserting air vent needle of ascending aorta was developed. The bleeding was not controlled by any means. On postmortem microscopic study, the histologic changes were strikingly limited to the ascending aorta from the region of the aortic valve ring.

  • PDF

디젤엔진 흡입과정에서 실린더내의 시뮬레이션 (Intake Flow Simulation in a D.I. Engine Cylinder)

  • 강신형;김응서;송명호
    • 오토저널
    • /
    • 제8권2호
    • /
    • pp.65-74
    • /
    • 1986
  • A computer program was developed to predict swirling steady axisymmetric turbulent flows by extending TEACH Code. It was applied to a reciprocating engine cylinder with a intake valve on the flat head. Flows were assumed to be steady and swirling. Effects of Reynolds number, the valve lift, and the swirl ratio on flow patterns and turbulence were investigated numerically. Flow patterns were reasonably predicted in comparison with experimental results. Length of the recirculation zone was shortened with increasing valve lifts and swirl ratios. Static pressure distributions show maximum value near the reattachment point of the incoming circular jet and minimum value near the maximum width of the valve attached recirculation zone.

  • PDF

공정제어루프 최종 조작부의 동작특성에 관한 연구 (Control Valve Positioner and Its effect on a Gas Turbine MW Control)

  • 김종안;신윤오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.728-730
    • /
    • 1998
  • The control valve positioner is a high gain plain proportional controller which measures the valve stem position and compares it to its setpoint which is the primary controller output. The positioner in effect is the cascade slave of the primary controller. In order for a cascade slave to be effecttive, it must be fast enough compared to the speed of its set point change. This paper describes the positioner transfer function and its effect on the entire control loop characteristic based on the simulation results. The result showed that the control valve and positioner determined the gain and phase angle in the high frequency range, while the primary controller and process determined those of the low frequency range. We can also anticipate the combined characteristics in the whole frequency range when each element's frequency response is known.

  • PDF

A Study on the Prevention of Spill of Fuel Oils and Lubricating Oils for Sunken Ships

  • Han, Won-Heui;Ju, Hae-Ji
    • 해양환경안전학회지
    • /
    • 제21권3호
    • /
    • pp.309-314
    • /
    • 2015
  • A sunken ship often involves an oil spill. This paper was carried out to minimize environmental and cost damages stemming from oil spil of sunken shipl. Through the analysis of both the standards of the oil tank system and installation, we have identified potential oil spill sites and proposed a remedy of prevention. The result of study, the air pipes of the oil tank are a vulnerable point for oil spill. Also, the remote control devices of emergency shut-off valve have poor accessibility at abandon ship, making it difficult to shut off the emergency shut-off valve. Thus, we propose the addition of a remote quick closing valve in the air pipe and the building of a central control system.

레이저 비전을 이용한 2단 가변밸브 리프트 모듈의 3D 조립검사에 대한 연구 (Study on the 3D Assembly Inspection of Two-Step Variable Valve Lift Modules Using Laser-Vision Technology)

  • 웬후쿠옹;김도중;이병룡
    • 대한기계학회논문집A
    • /
    • 제41권10호
    • /
    • pp.949-957
    • /
    • 2017
  • 본 논문에서는 2단 가변 밸브 리프트 모듈의 조립불량 검사를 수행하기 위하여, 레이저 비전 기반의 높이 측정 시스템을 개발하였다. 측정방식은 레이저 비전 센서 모듈을 이용하여 삼각 측량법의 원리에 기초하여 3차원 점군집(point cloud) 데이터를 수집하고, 이를 바탕으로 밸브 위치의 높이 차이를 계산하였다. 본 논문에서는 먼저, 측정 시스템의 구성과 제안된 높이 측정 알고리즘을 설명하였다. 그리고, 레이저 비전 기반의 3차원 측정을 위한 실험장치를 구성하였다. 마지막으로, 실험장치의 정확성과 반복성을 검증하기 위해서, 2단 가변 밸브 리프트 모듈에서의 래쉬조정기 및 밸브간의 고저 차이를 측정하는 실험들을 여러 번 수행하였다. 실험 수행결과, 제안된 레이저 비전 기반의 높이 측정 시스템은 2단 가변밸브 리프트 모듈 조립 검사에 대한 높은 정확성, 반복성 및 안정성을 확보하고 있음을 확인할 수 있었다.

DI 디젤기관 실린더 헤드표면의 순간온도 및 열유속 측정에 관한 실험적 연구 (An Experimental Study on the Measurement of Instantaneous Surface Temperature and Heat Flux on the Cylinder Head Surface of DI Diesel Engine)

  • 이재순;김기태;이현구;강태경;우종헌;김수성
    • 한국자동차공학회논문집
    • /
    • 제5권5호
    • /
    • pp.178-187
    • /
    • 1997
  • For the experimental measurement of heat flux of DI diesel engine combustion chamber, the instantaneous temperature probes and data acquisition system were developed. By the analysis of measured temperatures at the cylinder head, the temperature at the point 3 which is located between intake and exhaust valve was higher than that of the other points. Temperatures at the point located mear the exhaust valve were higher than those of intake valve. The instantaneous and mean temperature at the cylinder head increases proportionally to the increase of the engine speed, while the temperature swing varies inversely. Temperature swings have influence on the maximum heat flux values from gas into head surface. It has been verified that these probes and data acquisition system perform well by the comparison of the trend of instantaneous temperature variation with that of measured combustion chamber pressure variation with respect to crank angle. It is presumed that these probes could be used in the measurement of other parts of combustion chamber as piston, cylinder wall etc. for the future study.

  • PDF

흡기포트압력을 이용한 SI엔진의 체적효율 및 토크 성능 분석 (Analysis on Volumetric Efficiency and Torque Characteristics Using Inlet Port Pressure in SI Engines)

  • 이영주;홍성준
    • 대한기계학회논문집
    • /
    • 제16권7호
    • /
    • pp.1408-1418
    • /
    • 1992
  • 본 연구에서는 여러가지 흡기관 조건 및 밸브타이밍 변화에 대하여, 현재까지 연구에서 확인된 IVC에서 흡기포트압력 값의 체적효율에 대한 영향을 검토하고, 흡기 밸브가 열리는 동안 흡기 포트압력의 어느 부분 또는 지점이 엔진의 체적효율 변화를 설명해 줄 수가 있는지를 실험적으로 규명하고자 하였다.이 목적을 위해 각 흡입조 건에 대한 흡기포트압력 및 엔진 성능값을 측정.분석하여 서로의 연관성을 비교, 검토 하였다.

Force control of an asymmetric hydraulic cylinder for active suspensions

  • Kim, Wanil;Lee, Byung-Youn;Won, Sang-Chul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1124-1127
    • /
    • 1996
  • Asymmetric cylinders are usually used as an actuator of active suspensions. Since the force is influenced not only by the control but by the road roughness, force control is needed to track the desired force. But the conventional error feedback control treats the valve-cylinder dynamics at its operating point and many use the symmetric model which differ in all respects. We adopt an asymmetric cylinder model and apply a feedback linearization method for the force control to compensate both the valve nonlinearities and the effects of the road roughness.

  • PDF

통계적 파괴확률에 의한 Sin/Hip 질화규소의 신뢰도 분석(III) (Reliability Analysis of Statistical Failure Probability in Sin/Hip $Si_3N_4$ (III))

  • 송진수;이재석;김해일;이준근
    • 한국세라믹학회지
    • /
    • 제28권4호
    • /
    • pp.279-288
    • /
    • 1991
  • KIST/CARES reliability analysis program was used to calculate failure probabilities of piston pin and poppet valve. The 4-point bending test was performed on Sin/Hip Si3N4 for obtaining material parameters such as m, $\sigma$o, and KB, and the finite element analysis was performed using MSC/NASTRAN for obtaining stress distribution. The calculated failure probability of piston pin was lower than 10-6 and the failure probaility of poppet valve was greater than 0.95.

  • PDF