• Title/Summary/Keyword: Valve-opening pressure

Search Result 191, Processing Time 0.023 seconds

Suggestion of Logic to Control Power Plant Equipped ESS in case of Full Open Turbine Control Valve (ESS를 이용한 발전소 터빈제어밸브 전개 운전 제어로직 제안)

  • In Young Chung;Jae-Heon Lee
    • Plant Journal
    • /
    • v.18 no.4
    • /
    • pp.66-72
    • /
    • 2023
  • In order to respond to the demand for flexible operation of thermal power generation, development of natural sliding pressure operation that minimizes throttle loss by opening the turbine control valve 100% and maximize power generation efficiency in conjunction with ESS in order to quickly respond to fluctuations in the system frequency is required. The logic development of natural sliding pressure operation with ESS was developed to modify the existing logic at the power plant's top-level control logic such as the unit master, the boiler master and the turbine master. Cooperative control algorithms that complement the advantages and disadvantages of ESS operation (quick response, limited capacity) and power plant operation (slow response, continuous operation) not only improve efficiency when applied to actual power plants, but also respond quickly and flexibly to load demands to ensure system stability.

  • PDF

An Analysis of Mechanism of Auto-Sensing Breaker's Automatic Impact (지능형 브레이커의 자동타격 메카니즘 분석)

  • Park, Sung-Su;Noh, Dae-Kyung;Lee, Dae-Hee;Lee, Geun-Ho;Kang, Young-Ky;Cho, Jae-Sang;Jang, Joo-sup
    • Journal of the Korea Society for Simulation
    • /
    • v.25 no.4
    • /
    • pp.31-42
    • /
    • 2016
  • This study aims to identify the core technology for the automatic impact of the auto-sensing breaker that is one of the construction machinery which do not have a notable development success case yet in Korea. The study has been carried out as follows. Firstly, an analysis model was developed after determining the interconnection of pressure receiving area, opening area and port. And then, a simulation of situation that hard rock and soft rock are mixed was carried out to verify if it is possible to switch between long impact mode and short impact mode continuously. Lastly, the dynamic behavior of automatic control valve induced by the change of impact mode was analyzed based on the analysis result to decipher the core principle of automatic impact control.

A Study on the Control Method of Ventilating System for High Speed Train in a Tunnel (터널주행 고속전철의 환기시스템 제어 방법에 관한 연구)

  • 최영석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.3
    • /
    • pp.184-193
    • /
    • 2001
  • The present study develops programs simulating the internal pressure change of cars due to the change of external pressure when trains run into or passing each other in a tunnel. A new continuous ventilating system control method has been developed in order to alleviate the aural discomfort of passengers riding a high speed train. This method is based on the change of the charged and discharged flow rate by detecting the air pressures generated outside and inside of the train. When the outside and inside pressure are detected, the speed of the charge or exhaust fans and also the valve opening ratios are changed. The elementary performance of the system is checked using dta of the TGV-K high speed train at a speed of 300km/h. Moreover, applicability of the system to the Koran high speed train at a speed of 350 km/h is ascertained by simulation and its effectiveness as a means to alleviate the ear pains is confirmed. This application of the system to the Korean high speed vehicles running in the speed range of 350km/h is considered to have good prospect.

  • PDF

Real operation of 2 kW class reverse-Brayton refrigeration system with using scroll compressor package

  • Kim, Hyobong;Yeom, Hankil;Choo, Sangyoon;Kim, Jongwoo;Park, Jiho;In, Sehwan;Hong, Yong-Ju;Park, Seong-Je;Ko, Junseok
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.4
    • /
    • pp.40-44
    • /
    • 2020
  • This paper describes the real operation of 2 kW class reverse-Brayton refrigeration system with neon as a working fluid. The refrigeration cycle is designed with operating pressure of 0.5 and 1.0 MPa at low and high pressure side, respectively. Compressor package consists of several helium scroll compressors witch are originally used for driving GM cryocooler. Three segments of plate heat exchanger are adopted to cover the wide temperature range and the refrigeration power is produced by turbo expander. The developed refrigeration system is successfully operated at its target temperature of 77 K. In experiments, all parameters such as pressure, temperature, mass flow rate and valve opening are measured to investigate characteristics during cool-down process and normal state. The difference between design and real operation is discussed with measured experimental data. At normal state of 77 K operation, the developed reverse-Brayton refrigeration system shows 1.83 kW at 68.2 K of cold-end temperature.

Extent of Subprosthetic Pannus after Aortic Valve Replacement: Changes Over Time and Relationship with Echocardiographic Findings (대동맥판막치환술 후 발생한 판막하 판누스(Pannus): 시간에 따른 변화 및 심초음파 소견)

  • Mi Yeon Park;Hyun Jung Koo;Hojin Ha;Joon-Won Kang;Dong Hyun Yang
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.5
    • /
    • pp.1151-1163
    • /
    • 2020
  • Purpose This study aimed to evaluate changes of subprosthetic pannus on cardiac CT and determine its relationship to echocardiographic findings in patients with mechanical aortic valve replacement (AVR). Materials and Methods Between April 2011 and November 2017, 17 AVR patients (56.8 ± 8.9 years, 12% male) who showed pannus formation on CT and had undergone both follow-up CT and echocardiography were included. The mean interval from AVR to the date of pannus detection was 10.5 ± 7.1 years. In the initial and follow-up CT and echocardiography, the pannus extent and echocardiographic parameters were compared using paired t-tests. The relationship between the opening angle of the prosthetic valve and the pannus extent was evaluated using Pearson correlation analysis. Results The pannus extent was significantly increased on CT (p < 0.05). The peak velocity (3.9 ± 0.8 m/s vs. 4.2 ± 0.8 m/s, p = 0.03) and mean pressure gradient (36.4 ± 15.5 mm Hg vs. 42.1 ± 15.8 mm Hg, p = 0.03) were significantly increased. The mean opening angles of the mechanical aortic leaflets were slightly decreased, but there was no statistical significance (73.1 ± 8.3° vs. 69.4 ± 12.1°, p = 0.12). The opening angle of the prosthetic leaflets was inversely correlated with the pannus extent (r = -0.57, p < 0.001). Conclusion The pannus extent increases over time, increasing transvalvular peak velocity and the pressure gradient. CT can be used to evaluate the pannus extent associated with hemodynamic changes that need to be managed by surgical intervention.

A Study on the High Temperature Filtration Performance Test of Low Density Ceramic Filters (저밀도 세라믹 필터의 고온 여과 성능시험에 관한 연구)

  • 이동섭;홍민선;최종인
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.1
    • /
    • pp.75-84
    • /
    • 2001
  • Hot gas filtration method via using ceramic filters is an evolving technology applicable to numerous industrial and air pollution control processes. Alumino silicate, organic and inorganic binders were the major raw materials in manufacturing ceramic filters. In this work, disc type ceramic filters(50$\phi$$\times$10t) were manufactured by vacuum forming processes using ceramic raw materials. The porosity and bulk density of disc type ceramic filers ranged from 86 to 89% and from 0.27 to 0.36 g/㎤, respectively. In this work disc type ceramic medium were tested utilizing coupon experimental apparatus. Disc type filters showed high collection efficiencies over 99.96% with Darchs law coefficients of 4.1$\times$10(sup)10~9.63$\times$10(sup)10/$m^2$ depending on mean pore sizes. In addition, filtration and detachment of ceramic filters turned out to be performed effectively using 10 cm/sec face velocity, 5 minutes filtration cycle, 100msec pulse jet valve opening time and 3 bar pulsing pressure.

  • PDF

Effect on Transient Performance of Driver's Acceleration Type in MPI Gasoline Engine (운전자의 가속타입이 MPI 가솔린엔진의 과도성능에 미치는 영향)

  • 곽지현;전충환;장영준
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.75-81
    • /
    • 2000
  • To provide the appropriate direction for development of transient control in a gasoline engine, transient performance analysis and evalution under four accelerating types based on typical driver's acceleration type were implemented by experimental study. In order to evaluate the characteristics of transient performance quanititatively, the concept and method by transient response specifications were introduced. Several performance parameters in terms of engine speed(RPM), manifold absolute pressure(MAP), fuel injection duration($\DeltatI_{nj}$) and air excess ratio($\lambda$) were emasured simultaneously during the four types of the throttle valve opening with the step motor controlled by PC. The result showed that transient response specifications in terms of delay time, rising time and settling time characterized the transient performance for four acceleration types quantitatively. Intensified acceleration type was most economical and linear acceleration type revealed the best emission performance.

  • PDF

Congenital Aortic Stenosis: Report of 2 Cases (선천성 대동맥 판막 협착증 치험 2예)

  • 송명근
    • Journal of Chest Surgery
    • /
    • v.11 no.2
    • /
    • pp.194-198
    • /
    • 1978
  • Congenital aortic stenosis, a relatively uncommon congenital heart disease, may cause heart failure and may be fatal. In recent years, increased clinical awareness and improved diagnostic and operative technique has made accurate diagnosis and successful treatment possible. Recently we experienced 2 cases of congenital aortic stenosis, and which was corrected surgically. The first case was 9 years old boy, and second case was 16 years male. Preoperative diagnosis was entertained by angiography and cardiac catheterization in both cases. In each case, aortic valve opening was widened by incision along the fused commissure between the combined left and right coronary cusp on one side, and the noncoronary cusp on the other side. Post-op. pressure gradient between the aorta and left ventricle markedly reduced, in the first case, 50mmHg, and in the 2nd case, 55mmHg.Both patients discharged with good results 2 weeks after open heart surgery.

  • PDF

An Investigation into the Effect of Each Parameter of S/A on the Damping Force Using Dynamic Behaviour Analysis P/G (충격 흡수기의 동적거동 해석 프로그램을 이용한 각 파라미터가 댐핑력에 미치는 영향 조사)

  • 박재우;신상윤;주동우;이시복
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.371-376
    • /
    • 1996
  • The damping force of shock absorber in an automobile is determined by the components which construct the S/A. In this study we investigate the individual effect of these components on damping force. In addition, opening of important valve doling compression and tension cycle due to up-down reciprocation movement is also researched. Thus we are to strictly control the properties and tolerance of components having important effects on tile damping force and to produce S/A of better quality.

  • PDF

DEVELOPMENT OF A REVERSE CONTINUOUS VARIABLE DAMPER FOR SEMI-ACTIVE SUSPENSION

  • Yoon, Young-Hwan;Choi, Myung-Jin;Kim, Kyung-Hoon
    • International Journal of Automotive Technology
    • /
    • v.3 no.1
    • /
    • pp.27-32
    • /
    • 2002
  • Semi-active suspension systems are greatly expected to be in the mainstream of future controlled suspensions fur passenger cars. In this study, a continuous variable damper for a passenger car suspension is developed. It is controlled actively and exhibits high performance with light weight, low cost, and low energy consumption. To get fast response of the damper, reverse damping mechanism is adapted, and to get small pressure change rate after blow-off, a pilot controlled proportional valve is designed and analyzed. The reverse continuous variable damper is designed as a HS-SH damper which offers good body control with reduced transferred input force from tire, compared with any other type of suspension system. The damper structure is designed, so that rebound and compression damping force can be tuned independently, of which variable valve is placed externally. The rate of pressure change with respect to the flow rate after blow-offbecomes smooth when the fixed orifice size increases. Damping forces are measured with the change of the solenoid current at the different piston velocities to confirm the maximum hysteresis of 20N, linearity, and variance of damping farce. The damping farce variance is wide and continuous, and is controlled by the spoof opening, of which scheme is usually adapted in proportional valves. The reverse continuous variable damper developed in this study is expected to be utilized in the semi-active suspension systems in passenger cars after its performance and simplicity of the design is confirmed through real car test.