• Title/Summary/Keyword: Valve throat

Search Result 12, Processing Time 0.026 seconds

Analysis of Pressure Relief Valve Considering Interaction between Valve Stem Motion and Flow (압력 릴리프 밸브 스템부 운동 및 유동 연계해석 기법)

  • Cho, Nam-Kyung;Shin, Dong-Soon;Han, Sang-Yeop;Kim, Young-Mog
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.121-127
    • /
    • 2007
  • Direct acting pressure relief valve applicable to propellant tank of launch vehicle is modeled in this study The flow resistance of the partially opened valve is modeled as a function of the distance of the valve stem from the resting position. The position of the valve varies transiently as a function of its mass, the spring force, sliding friction, and the pressure differential. Choking at valve throat and compressibility are considered for the analysis. This study presents systematic analysis method for pressure relief valve applicable to propellant tank of liquid rocket. The results shows transient flow resistance caused by stem motion and the importance of choking at valve throat for pressure relief valve design.

  • PDF

An Experimental Study on Water-Hammer Effect for Spacecraft Propulsion System (인공위성 추진계통 관로내의 수격효과에 관한 실험적 연구)

  • Kwon, Ki-Chul;Lee, Eun-Sang;Park, Sang-Min;Kang, Shin-Jae;Rho, Byung-Joon
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.288-293
    • /
    • 2001
  • This paper presents the water-hammer effect due to the rapid opening and closing of isolation valve and thruster valve in the spacecraft propulsion system. The single propellant feed system was modeled to investigate the maximum peak pressure due to the water-hammer effect. The test parameters are tank supply pressure, shape and throat length of orifice and line length. Kerosene was used as the inert simulant propellant liquid instead of hydrazine. As downstream line length after isolation valve increased from 1.5 to 2.5m, the maximum line-filling water-hammer peak pressure decreased, but the average time interval between peak pressures increased. The maximum line-filling water-hammer peak pressure with orifice was lower than without orifice, and the maximum line-filling water-hammer peak pressure with orifice at the back of isolation valve was lower than with orifice in front of isolation valve. Without orifice, the maximum water-hammer peak pressure due to the rapid opening and closing of the thruster valve was about 126% of tank supply pressure. With orifice, it decreased. As orifice throat length increased, it decreased. The maximum water-hammer peak pressure due to the rapid closing of the thruster valve with converging-diverging orifice was lower than normal orifice. It was found that the orifice as a means of pressure drop was very effective to reduce the water hammer peak pressure at the thruster valve. The results of this study can be used for the design of spacecraft liquid propulsion feed system.

  • PDF

Numerical Analysis of Incompressible and Compressible Flow Around a Butterfly Valve (버터플라이 벨브 주위의 비압축성 및 압축성유동 특성에 대한 수치해석)

  • 이종욱;이두환;최윤호
    • Journal of Energy Engineering
    • /
    • v.11 no.1
    • /
    • pp.26-33
    • /
    • 2002
  • In this paper, incompressible and compressible flow characteristics around the butterfly valve have been investigated. In order to simplify the problem, a flat disk valve with various valve disk angles and pressure ratios is considered in the present calculations. It was found that as the disk angle increases, the stagnation point on the front surface of the disk moves to the center of the surface and the inflow velocity decreases. The maximum flow velocity occurs at the downstream of throat because of the formation of vents contracta. As the pressure ratio decreases, compressibility effects increase and the jet formed between the throttle body wall and the disk edge becomes supersonic. This flow also builds up as a shock cell structure. The increase of disk angle and pressure ratio makes the mass flow at the inlet decrease, while the increase of disk angle and the decrease of pressure ratio make the pressure loss coefficient increase.

A numerical study on the aerodynamic characteristics of a variable geometry throttle valve(VGTV) system controlling air-flow rate (유량 제어장치인 가변스로틀밸브의 기하학적 형상변화에 따른 공기역학 특성분석 연구)

  • Cho, Hyun-Sung;Kim, Chul-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.378-383
    • /
    • 2013
  • A butterfly throttle valve has been used to control the brake power of an SI engine by controlling the mass flow-rate of intake air in the induction system. However, the valve has a serious effect on the volumetric efficiency of the engine due to the pressure resistance in the induction system. In this study, a new intake air controlling valve named "Variable Geometry Throttle Valve(VGTV)" is proposed to minimize the pressure resistance in the intake system of an SI engine. The design concept of VGTV is on the application of a venturi nozzle in the air flow path. Instead of change of the butterfly valve angle in the airflow field, the throat width of the VGTV valve is varied with the operating condition of an SI engine. In this numerical study, CFD(computational fluid dynamics) simulation technique was incorporated to have an aerodynamics performance analysis of the two air flow controlling systems; butterfly valve and VGTV and compared the results to know which system has lower pressure resistance in the air intake system. From the result, it was found that VGTV has lower pressure resistance than the butterfly valve. Especially VGTV is effective on the low and medium load operating condition of an SI engine. The averaged pressure resistance of VGTV is about 49.0% lower than the value of the conventional butterfly throttle valve.

A Numerical Analysis of Pressure Distribution and Pressure Drop in Receptacle for Hydrogen Charging System (수소 충전 시스템용 리셉터클의 내부 압력 분포와 압력 강하에 관한 수치적 연구)

  • YUANGANG WANG;SEUNGHYEOK LEE;CHAE HOON SOHN;SEDONG LEE;HYUNBOK LEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.5
    • /
    • pp.497-504
    • /
    • 2023
  • This study analyzes pressure distribution and pressure drop in the receptacle used in charging system of hydrogen fuel cell vehicles. The objective is to minimize receptacle-induced pressure drop by redesigning internal flow channels. Through numerical simulations, three receptacle variants are compared with a baseline case. Results show reduced pressure drop in the filter section. However, the check valve section exhibits higher pressure drop, requiring further improvement. By increasing throat diameter, pressure drop is decreased by 28% between inlet and outlet of the receptacle. This study shows the relationship between dynamic pressure and pressure drop, providing a guideline for receptacle performance optimization. The redesigned receptacle offers potential for enhancing hydrogen charging efficiency.

Evaluation of characteristics for microbubble generation according to venturi nozzle specification (벤튜리 노즐 제원에 따른 마이크로버블 발생 특성 평가)

  • Lim, Ji-Young;Kim, Hyun-Sik;Park, Soo-Young;Kim, Jin-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.6397-6402
    • /
    • 2015
  • This research was performed to review operating parameters, optimum condition and check characteristic of microbubble generation for using bubble size distribution according to venturi specification. Optimum operating condition have airflow rate 0.3 LPM, 3 bar(pressure tank) and connecting nozzle directly(without valve), it is advantageous to generate microbubble. In case of characteristic of microbubble generation according to venturi specification, effect that nozzle specification affects bubble size distribution is low impact. But considering performance aspects, when using nozzle that throat diameter 3-4 mm, $D_{50}$ are $54.98-61.19{\mu}m$(D3L15, D4L15), fraction of bubble less than $50{\mu}m$ are 0.326, 0.345. And it is superior to others. Besides, $D_{50}$ and fraction of bubble less than $50{\mu}m$ of throat length 20 mm are $49.40-54.98{\mu}m$, 0.447, respectively And nozzle that throat length 20 mm is relatively tendency to generate microbubble stably.

A Case of Septic Pulmonary Embolism Associated with MRSA Infective Endocarditis (메치실린 내성 황색포도상구균 세균성 심내막염에 의한 패혈성 폐색전증 1예)

  • Lee, Ki-Jong;Kim, Nha-Young;Kim, Ja-Seon;Yun, Han-Kyeol;Oh, Mi-Jung;Kim, Do-Hoon;Cho, Sang-Kyun;Ryu, Han-Young;Bae, Young-A;Kim, Dae-Bong;Shin, Mi-Kyung;Chin, Jae-Yong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.69 no.2
    • /
    • pp.124-128
    • /
    • 2010
  • Septic pulmonary embolism is the process in which an infected thrombus becomes detached from its site of origin and lodges in a pulmonary artery, and is usually associated with infective endocarditis, especially right-sided, or infection-associated with indwelling catheters, peripheral septic thrombophlebitis, and periodontal diseases, etc. Here, we report a case of septic pulmonary embolism associated with tricuspid valve infective endocarditis. A 23-year-old female was admitted to our hospital, due to fever, sore throat, and myalgia. In her past medical history, she had undergone a surgical operation for closure of a ventricular septal defect, but was informed that the operation resulted in an incomplete closure. The initial chest radiograph demonstrated multiple rounded, parenchymal nodules in various sizes; several nodules had central lucency suggesting cavitations. Echocardiography demonstrated a large vegetation attached to the septal tricuspid valve leaflet, extending from right ventricular inflow tract to outflow tract. Computed tomography of thorax revealed bilateral peripheral nodules and wedge-shaped consolidation at various sizes, mostly accompanied by cavitations.

Numerical study for fluid-structure interaction of blood flow in TPLS (박동형 인공심폐기에서의 혈류의 고체-유체 상호작용에 대한 수치적 연구)

  • Jung G. S.;Seong H. C.;Shim E. B.;Ko H. J.;Min B. G.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.705-706
    • /
    • 2002
  • Hemodynamics of the TPLS(Twin Pulse Life Support System) is numerically investigated to delineate the possibility of hemolysis in blood. Computational method employing finite element algorithm is utilized to solve the blood flow of the sac squeezed by moving actuator. We assume that the blood flow interacts with the sac material which is activated by the rigid body motion of the actuator. Valve dynamics at the ends of the sac is simplified as on/off type motion. We compute the transient viscous flow in the two-dimensional geometry of the blood sac. Incompressible laminar flow is simulated on the assumption of Newtonian fluid. Blood velocity has a step gradient near the throat of the sac formed by the moving actuator. According to the decrease of the gap size of blood passage, the magnitude of shear stress in the blood is dramatically increased. Numerical solutions show that the maximum value of shear stress in the blood flow in TPLS is relatively smaller than that of the roller type ECLS.

  • PDF

Unexpected Death by Sepsis of Staphylococcus aureus with Infective Endocarditis and Paravertebral Abscess in a Fisherman during Sailing out for Fish: An Autopsy Case (심내막염과 척추 주위 농양을 동반한 황색포도알균에 의한 출어 중의 선상 패혈증 사망: 증례 보고)

  • Kim, Youn Shin;Hwang, In Kwan;Moon, Seohyun;Park, Ji Hye;Lee, Young Seok
    • The Korean Journal of Legal Medicine
    • /
    • v.42 no.4
    • /
    • pp.153-158
    • /
    • 2018
  • Staphylococcus aureus is an important cause of human infections, and it is also a commensal that colonizes the nose, axillae, vagina, throat, or skin surfaces. S. aureus has increasingly been recognized as a cause of severe invasive illness, and individuals colonized with this pathogen are subsequently at increased risk of its infections. S. aureus infection is a major cause of skin, soft tissue, respiratory, bone, joint, and endovascular disorders, and staphylococcal bacteremia may cause abscess, endocarditis, pneumonia, metastatic infection, foreign body infection, or sepsis. The authors describe a case of a fisherman who died of sepsis on a fishing boat during sailing out for fish. The autopsy shows paravertebral abscess, pus in the pericardial sac, infective endocarditis with vegetation on the aortic valve cusp, myocarditis, pneumonia and nephritis with bacterial colonization, and also liver cirrhosis and multiple gastric ulcerations.

Experimental Characteristic of Drain Control to Cherepnov Water Lifter (Cherepnov 송수기에 대한 배수제어방식의 실험적 특성)

  • 박성천;이강일
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.6
    • /
    • pp.67-79
    • /
    • 1997
  • The perpose of this study was to suggest the experimental characteristic of the Cherepnov Water Lifter following the drain mode. The Cherepnov Water Lifter(CWL), which is powered by the potential energy of water, can be set to operate automatically when the water m a tank is drained. In this study, a CWL is constructed in the valve drain controlling mode(VCM) and the siphon drain controlling mode(SCM), and a pressure transducer is installed. It was found that, in the VCM, intake flow volume is proportional to both delivery flow volume and drain flow volume. In the SCM, intake flow volume is proportional to drain flow volume, and the average delivery rate is proportional to both efficiency and the water utilization ratio. Also, in the VCM, the water utilization ratio is 35~49%, efficiency is 62~9O%, average delivery rate is 12.8~81.2$cm^3$/s, and the average drain rate is 14.O~91.5c$cm^3$/s. On the contrary in the SCM, the water utilization ratio is 1.7~38%, efficiency is 3~58%, average delivery rate is 3.1 ~69.2$cm^3$/s, and the average drain rate is shown as 114.5~ 183$cm^3$/s. As a result of the water utilization ratio, efficiency, average delivery rate, and average drain rate are compared, the VCM is found to be superior and the more economical mode. However, the VCM requires manpower and electricity to operate the electronic machinery involved, while the SCM requires no manpower or electricity at all. An economic evaluation of these differences will be necessary in the future. Also, in the SCM, studies to improve water utilization ratio and efficiency, to find the optimum height of the siphon for decreasing the average drain rate, and to determine the radius of curvature of throat have to be conducted in advance, since a large flow rate is drained during the priming action of the siphon.

  • PDF