• 제목/요약/키워드: Valve replacement

검색결과 684건 처리시간 0.021초

Ionescue-Shiley 인조판막을 이용한 판막대치술의 혈류역학적 성적 (Hemodynamic evaluation of the Ionescu-Shiley pericardial xenograft heart valve)

  • 정원상;김근호
    • Journal of Chest Surgery
    • /
    • 제17권2호
    • /
    • pp.223-230
    • /
    • 1984
  • Since January 1977 to the end of September 1982, total 60 Ionescu-Shiley pericardial xenograft heart valves were implanted for valve replacement in 50 patients at the Han Yang University Hospital. The operative procedures were as follow: Mitral valve replacement [MVR] in 25 patients, Mitral valve replacement [MVR] and Tricuspid valve [TV] annuloplasty in 7 patients, Aortic valve replacement [AVR] in 8 patients, Aortic valve replacement [AVR] and Mitral valve replacement [MVR] in 8 patients. Aortic valve replacement [AVR] and Mitral valve replacement [MVR] and Tricuspid valve [TV] annuloplasty in 2 patients. To evaluate the immediate hemodynamic changes after valve replacements, the pressures of each cardiac chamber and ulmonary artery were checked before and after valve replacement on the operation table. Right ventricle [RV] pressure was decreased from 52.09\ulcorner6.71 to 45.57\ulcorner5.03 mmHg, Pulmonary artery [PA] pressure was decreased from 45.97\ulcorner2.69 to 41.00\ulcorner3.99 mmHg, and Left atrium [LA] pressure was decreased from 30.33\ulcorner13.02 to 22.76\ulcorner.97 mmHg before and after valve replacement. In MVR group, RV pressure was decreased from 49.17\ulcorner7.89 to 43.14\ulcorner4.14 mmHg, PA pressure was decreased from 44.67\ulcorner3.18 to 38.67\ulcorner2.85 mmHg, and LA pressure was decreased from 31.46\ulcorner13.47 to 21.91\ulcorner.17 mmHg. In AVR group, RV pressure was decreased from 53.0\ulcorner7.44 to 44.71 \ulcorner3.24 mmHg, PA pressure was decreased from 34.83\ulcorner0.73 to 31.86\ulcorner.36 mmHg, and LA pressure was not changed. In double valve replacement [MVR and AVR] group, RV pressure was decreased from 57.50\ulcorner3.82 to 42.50\ulcorner.80 mmHg, PA pressure was decreased from 51.17\ulcorner1.42 to 43.33\ulcorner4.53mmHig, and LA pressure was decreased from 34.33\ulcorner2.09 to 25.50\ulcorner0.21 mmHg. But in the group where MVR and TV annuloplasty were performed, preoperative RV and PA pressure were markedly increased and no pressure decrease in RV and PA noticed after valve replacement. This study shows good immediate postoperative hemodynamic results after valve replacement using Ionescu-Shiley xenograft valve except in the cases of MVR and TV annuloplasty and advanced disease with pulmonary hypertension.

  • PDF

심장판막 치환술후 직업복귀에 대한 임상적 고찰 (A Clinical Study for Return to Work after Heart Valve Replacement - A Case Report -)

  • 김현경
    • Journal of Chest Surgery
    • /
    • 제24권10호
    • /
    • pp.967-972
    • /
    • 1991
  • Between Feb. 1982 and July 1990, 173 patients [male: 89, female: 84] Who underwent heart valve replacement for acquired valvular heart disease on the Department of Thoracic and Cardiovascular Surgery, School of Medicine, Pusan National University, were reviewed for return to work after heart valve replacement. The replaced valve were mitral [128, 74.0%], aortic[10, 5.8%], mitral & aortic[35, 20.2%]. Two tricuspid valve replacement were excluded. Several important factors influencing the return to work were age, the employment status before surgery, the number of replaced valve, the pre - op NYHA functional class and cardiac function [ejection fraction]. These factors were closely related to the optimal time of heart valve replacement. It can be concluded that the rate of return to work and the quality of life would be improved if valve replacement were performed at an earlier stage of valvular heart disease.

  • PDF

인공심장판막의 재치환술 (Replacement of the Prosthetic Heart Valves -Clinical analysis of 12 cases-)

  • 김덕실;전상훈
    • Journal of Chest Surgery
    • /
    • 제29권2호
    • /
    • pp.164-170
    • /
    • 1996
  • From January 1986 to June 1993, 12 patients Aad required reoperation: 9 had undergone mitral and 3 aortic valve replacement. Five were male and 7 female, and ages ranged from 29 to 61 years. Replacement of the prosthetic heart valve was performed at a mean interval of 98 $\pm$ 1 months after the Hrst operation. In aortic valve replacement patients the mean interval was 115 $\pm$ 2 months and in mitral valve replacement patients 98 $\pm$ 4 months. Primary tissue failure was the most frequent reason of replacement (10 patients) followed by valve thrombosis (1 patient) and prophylactic replacement (1 patient) in order. The most pronounced pathology of the failed prosthetic heart valves seen in the primary tissue failure group was calcification, perforation, shrinkage and tearing of the cusps. There was one early operative death (8.3%) due to intractable low cardiac output and acute renal failure. Eleven early survivors had successful operative results and there was no late death.

  • PDF

Bjork-Shiley 기계판막의 임상적 연구 (Clinical Analysis of Bjork-Shiley Mechanical Valve Replacement)

  • 김병열
    • Journal of Chest Surgery
    • /
    • 제22권3호
    • /
    • pp.393-401
    • /
    • 1989
  • Between Dec. 1984, and May, 1988,96 prostheses were implanted in 80 patients at Dept. of Thoracic k Cardiovascular Surgery of National Medical Center. 43 patients had mitral valve replacement, 21 underwent aortic valve replacement, and 15 had double valve replacement [Mitral k Aortic], and 1 had tricuspid valve replacement. Seventy-one cases [88.8 %] were in NYHA Class III or IV. The mean duration of follow up was 22.1 months and follow-up information was available for 74 [92.5 %] of the patients. The overall actuarial survival rate at 45 months was 93.05 % and overall hospital mortality was 10 %, late Mortality was 5 %. The linearlized incidence of thromboembolism [2.4%/pt-yr], thrombotic valve obstruction [1.6 %/pt-yr], anticoagulant related bleeding [0.8 %/pt-yr]. There were no fatal valve related complications. The blood was studied in 40 patients 1 year after valve operation. Hgb and reticulocyte count were within normal values and Serum LDH value was slightly elevated but it was not of clinical significance. In conclusion, Monostrut Bjork-Shiley valve prosthesis to be a reliable valve substitute with an acceptable incidence of complications.

  • PDF

심장판막치환술 후 재치환술에 관한 임상연구 (Clinical Analysis of Repeated Heart Valve Replacement)

  • 김혁;남승혁;강정호;김영학;이철범;전순호;신성호;정원상
    • Journal of Chest Surgery
    • /
    • 제40권12호
    • /
    • pp.817-824
    • /
    • 2007
  • 목적: 심장판막치환술 시에 선택하는 판막에는 크게 기계판막과 조직판막이 있다. 두 가지는 각기 피할 수 없는 단점이 있는데 조직판막의 경우 판막의 퇴행성 변화에 따른 재수술이 가장 문제가 되며 판막재치환술의 위험도가 적다면 조직판막의 사용이 증가되리라 생각된다. 이에 저자들은 심장판막치환술 후 재치환술의 위험도 및 사망률을 심장판막 일차치환술과 비교 평가하였다. 대상 및 방법: 1995년 1월부터 2004년 12월까지 최근 10년간 본 병원에서 연속적으로 시행한 심장판막수술 환자 239명 중 심장판막치환술 후 재치환술을 받은 25명과 심장판막일차치환술을 받은 158명의 한자를 후향적으로 비교, 분석하였다. 결과: 심장판막 재치환술군과 심장판막 일차치환술군 간의 나이, 성별, 술전심박출률 등은 통계적으로 큰 차이가 없었다. 재치환군에서 첫 수술의 판막은 기계판막 3예, 조직판막 22예로 이중 대동맥판막과 승모판막을 동시에 조직판막으로 치환한 경우가 1명 있었으며, 재수술까지의 기간은 기계판막의 경우 92개월, 조직판막인 경우 평균 160개월이었다. 체외순환 및 대동맥차단의 평균시간은 재치환술의 경우 152분, 108분, 일차치환술의 경우 130분, 89분으로 통계적인 유의함을 보였다. IABP의 사용은 재치환술의 경우 2예(8%), 일차치환술은 6예(3.8%)로 차이를 보였으며, 수술사망은 재치환술의 경우 1예(4%), 일차치환술의 경우 9예(5.1%)였다. 술 후 합병증 중에서 술 후 48시간 이상의 인공호흡이 재수술에서는 13.6%, 1차 수술에서 5.7%로 차이를 보였고 다른 인자에서는 큰 차이를 보이지 않았다. 수술 후 평균 추적기간은 $6.5{\pm}3.2$년이고 재치환술 환자의 5년 생존율은 74%였으며 일차치환술의 경우 5년 생존율은 95%를 보여 유의한 차이를 보였다. 결론: 심장판막재치환술은 일차치환술과 비교하여 볼 때 수술 위험도는 약간 증가되나 사망률에서는 큰 차이를 보이지 않았다. 따라서 재수술 위험을 고려하여 조직판막을 너무 기피하는 것은 재고되어야 하며 다른 장점이 많은 조직판막의 선택적인 사용이 권장된다. 그러나 재치한술의 경우 술전 상태가 나빴던 환자에서 만기사망률이 높으므로 일차치환술 후 적절한 심장기능 및 환자상태의 평가가 필요하며 너무 늦지 않은 적정한 시기에 재치환술을 고려해야 겠다.

후천성 심질환의 인공판막치환술에 대한 임상적 고찰 (Clinical Analysis of Prosthetic Valve Replacement on Acquired Heart Disease)

  • 이준영;지행옥
    • Journal of Chest Surgery
    • /
    • 제22권6호
    • /
    • pp.951-959
    • /
    • 1989
  • Between September, 1972 and September, 1989, total 359 patients were operated for acquired heart disease at Department of Thoracic and Cardiovascular Surgery, Hanyang University Hospital. A consecutive series of 293 prosthetic valve replacement was also performed during this period. The results were summarized as follows; 1. There were 141 men and 218 women, whose ages ranged from 6 to 64 years, [mean 35.5 years] 2. Out of 293 cases, mitral valve replacement was 182 cases, aortic valve replacement was 39 cases and double valve replacement was70 cases. 3. Early post-operative death was 30 cases [Mortality; 8.4 %] and late death was 9 cases in the survivors. 4. Re-operation was 30 cases and operative mortality was 10%. 5. Mean post-operative interval was 76 months. [Ranged from 216 months to 2 months] 6. Among re-operation cases, primary prosthetic valve failure was 16 cases and paravalvular leakage was 2 cases. 7. Since January 1988, 79 cases of prosthetic valve replacement were performed and then 1 case was expired. [Mortality; 1.2 %]

  • PDF

심장다판치환술의 임상적 고찰 (Clinical Evaluation of Multiple Valve Replacement)

  • 오상기
    • Journal of Chest Surgery
    • /
    • 제33권2호
    • /
    • pp.160-166
    • /
    • 2000
  • Background: The purpose of this study is to evaluate and analyze the surgical results in patients undergoing operations for multiple for multiple valvular heart diseases. Material and method: From April 1982 to June 1997 multiple valve replacement was performed in 150 patients mitral and aortic valve replacement were done in 135 patients mitral and tricuspid valve replacements in 10 patients triple replacements in 4 patients and aortic and tricuspid valve replacement in 1 patient. Of the valves implanted 157 were St. Jude 104 Duromedics 20 Carpenter-Edwards 6 Bjork-Shiley 6 Ionescu-Shiley and 2 Medtronics. Result: The hospital mortality rate was 10.7% (16/150) and the late mortality rate was 7.2% (8/134) The mortality rate was high in early operative period but decreased with time. The causes of death were low cardiac output in 9 sudden death in 3 congestive heart failure in 3 bleeding in 2 cerebral thrombosis in 1 leukemia in 1 multiorgan failure in 1 and so on . The actuarial survival rate excluding operative death was 83.1% at 15 years. Conclusion: With a follow-up now extending to 15 years the multiple valve replacement continues to be reliable procedure with relatively low mortality and morbidity.

  • PDF

16세 미만에서의 심장판막치환술 (Cardiac valve replacement in patient less than 16 years of age)

  • 김응중;서경필;이영균
    • Journal of Chest Surgery
    • /
    • 제19권1호
    • /
    • pp.108-115
    • /
    • 1986
  • During 12 years period from 1974 to 1985, 76 valve replacement procedures were performed at Seoul National University Hospital in 67 pediatric patients aging up to 15 years [mean 12.3 years] and it was 7.3% of total valve replacement procedures in same period. Sixty seven patients were composed of 44 males and 23 females. Of the 67 patients, 43 patients had acquired valve lesions and 24 patients congenital valve lesions. Sixty cases received single valve replacement, 7 cases double or triple valve replacement and 9 cases redo-valve replacement. Sixty seven patients received 84 valves [65 bioprosthetic valves and 19 prosthetic valves by] 76 operations, Sixty three of 65 bioprosthetic valves had been replaced before 1983 and 15 of 19 prosthetic valves in recent 2 years. Eleven patients [14.6%] died within one month post-operatively and 8 patients [10.5%] during the follow-up period with the overall mortality rate of 25.1%. There were early post-operative complication of 23 cases [30.3%] and late post-operative complication of 27 cases [35.3%] with the total complication rate of 65.8%. In 58 patients received bioprosthetic valves, there were 14 cases of restenosis of replaced valves. Of the 14 cases of bioprosthetic valve restenosis, 8 cases received redo-valve replacement procedures without mortality in 1 5/12-5 years after initial operation but 4 cases died without reoperation and 2 cases lost during follow-up. The overall mortality and complication rate were still high but they markedly decreased during recent 2 years. So, in spite of its containing many problems, valve replacement in children is becoming safe and useful procedure in whom valve reconstructive procedures are impossible.

  • PDF

인공판막치환술후 재수술 (Reoperations for Prosthetic Valve Replacement)

  • 유영선
    • Journal of Chest Surgery
    • /
    • 제24권11호
    • /
    • pp.1090-1097
    • /
    • 1991
  • Between January 1981 and January 1991, 554 patients underwent prosthetic valve replacement. A bioprosthetic valve was replaced in 238 cases and mechanical valve 316 cases. Thirty-eight patients underwent 40 reoperations for repair or replacement, an average of 53.6 months after initial implantation. There were 21 women and 19 men, aged 12 to 60 years[mean 35.3]. A bioprosthetic valve was implanted in 31 cases and a mechanical valve in 9 cases for initial operation. Indications for reoperation were primary tissue failure in 23 cases[57.5%], endocarditis in 9[22.5%], periprosthetic leak in 4[10%]. and valve thrombosis in 4[10%]. Operations performed included 5 aortic valve replacements, 26 mitral valve replacement, 8 double valve replacements, and 1 thrombectomy. A mechanical valve was replaced in 33 cases[84.6%] and a bioprosthesis in 6[15.4Zo] for reoperation. A second reoperation was required in 2 patients. Surgical mortality was 10% . Among the 34 early survivors followed-up for an average of 19.8 months. there was 1 late death and 3 were lost to follow-up. Among the 30 late survivors being followed up, 28[93.3%] remained in New York Heart Association Class I or II and two in Class III [6.7%].

  • PDF

인공심장판막의 재치환술 5례 보고 (Replacement of prosthetic heart valves Report of 5 cases)

  • 신제균
    • Journal of Chest Surgery
    • /
    • 제18권4호
    • /
    • pp.655-662
    • /
    • 1985
  • From January 1985 to July 1985, prosthetic heart valves were replaced in 5 patients at Keimyung University Dongsan Medical Center. The patients included three women and two men ranging in age from 22 to 41 years. Three mitral valve replacements, one aortic valve replacement and one double valve replacement [mitral and aortic valve replacement] were done at the first valve operations. Reoperation were performed 2 to 76 months after the first operations, Prosthetic valve endocarditis occurred in 3 patients, early in one and late in two and primary valve failure occurred in 2 patients. In operative findings, vegetation in prosthetic valve endocarditis and calcification in primary valve failure were found. All except one had relatively successful operative results. One died of early fungal prosthetic valve endocarditis due to relapsed prosthetic valve endocarditis with heart failure and block.

  • PDF