• Title/Summary/Keyword: Valve regulated lead acid

Search Result 17, Processing Time 0.034 seconds

Influence of Safety Valve Pressure on Gelled Electrolyte Valve-Regulated Lead/Acid Batteries Under Deep Cycling Applications

  • Oh, Sang-Hyub;Kim, Myung-Soo;Lee, Jin-Bok;Lee, Heung-Lark;, Myung-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.1
    • /
    • pp.75-80
    • /
    • 2002
  • Cycle life tests have been carried out to evaluate the influence of safety valve pressure on valve regulated lead/acid batteries under deep cycling applications. Batteries were cycled at 5 hour rates at 100% DOD, and safety valve pressure was set to 1.08 and 2.00 bar, respectively. The batteries lost 248.3 g and 235.3 g of water for each case after about 1,200 cycles, but the cyclic performances of the batteries were comparable. Most of the gas of the battery during discharging was hydrogen, and the oxygen concentration increased to 18% after 3 hours of charging. The micro structure of the positive active materials was completely changed and the corrosion layer of the positive grid was less than $50{\mu}m$, regardless of the pressure of the safety valve after cycle life tests. The cause of discharge capacity decrease was found to be water loss and the shedding of the positive active materials. The pressure of safety valve does not give little effect to the cyclic performances and the failure modes of the gelled electrolyte valve-regulated lead acid batteries.

The Optimization of Gel Electrolytes on Performance of Valve Regulated Lead Acid Batteries

  • An, Sang-Yong;Jeong, Euh-Duck;Won, Mi-Sook;Shim, Yoon-Bo
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.5
    • /
    • pp.998-1002
    • /
    • 2008
  • The gel electrolytes were prepared with sulfuric acid and phosphoric acid, where hydrophilic fumed silica was used as a gelling agent. The influences of gel electrolyte on performance of the valve regulated lead acid (VRLA) batteries were investigated employing capacity tests, electrochemical impedance spectroscopy and scanning electron microscopy. The initial capacities of the sulfuric gel VRLA batteries were higher than that of phosphoric gel VRLA batteries. The sulfuric gel VRLA battery using 1.210 specific gravity of sulfuric acid with hydrophilic fumed silica exhibited the highest capacity of 0.828Ah. In the impedance measurements, the ohmic and charge transfer resistances for the phosphoric gel VRLA batteries were higher thanthat of sulfuric gel batteries. The morphology of electrodes of phosphoric gel VRLA batteries were more deteriorated in the SEM image.

A Study on the Establishment of Impedance/Conductance Guide Line for Diagnosis of Lead-Acid Battery's State of Health(SOH) (납축전지 건전상태 진단을 위한 기준 임피던스/컨덕턴스 설정에 관한 연구)

  • Kim, Chong-Min;Bang, Sun-Bae;Shong, Kil- Mok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.214-220
    • /
    • 2009
  • Battery is one of the emergency power and its reliability is a very important to keep up the minimum of building capabilities in case of interruption of electric power. This paper, a comparison was made between three different types of instrument on 30 valve regulated lead acid(VRLA) TYPE 12[V]/100[AH] batteries, and then their indicated measured values(impedance/conductance) were compared with the measured capacity of the battery. As a result, Measured value of instrument is strongly related to battery's capacity in the same group battery and Impedance/Conductance guide line for diagnosis of lead-acid battery's state of health(SOH) is a different from each battery guoup.

A Study on the Valve Regulated Lead-Acid Battery using Sulfuric Acid Gel Electrolyte for New Generation Substitution Energy (황산 겔 전해질을 사용한 차세대 대체에너지용 밀폐형 납축전지에 관한 연구)

  • Park, Keun-Ho;Ju, Chan-Hong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.164-173
    • /
    • 2004
  • The capacity and long life of gel electrolyte batteries is connected with gas recombination producting $PbO_2$ and Pb electrode. We prepared with sulfuric acid gel electrolyte to know gel characteristics per density to assemble valve regulated lead-acid (VRLA) batteries. We studied on actions of sulphuric acid gel electrolyte by measuring electrolyte dispersion using Brewster-angle microscope (BAM), charge-discharge cycle, and electrode structure using scanning election microscope (SEM). Sulphuric acid density 1.210 showed excellent gel dispersion in sol condition, electrode condition after fifty cycles in this study.

Prediction of Charge/Discharge Behaviors and Aging of the VRLA Battery (VRLA 배터리의 충/방전 거동과 노화 예측 모델링)

  • Lee, Myoungkyou;Cho, Jaesung;Shin, Chee Burm;Ryu, Ki seon
    • Korean Chemical Engineering Research
    • /
    • v.56 no.6
    • /
    • pp.779-783
    • /
    • 2018
  • In this work, Mathematical modeling was carried-out to predict the charging/discharging characteristics of VRLA (Valve regulated lead acid) battery, which is mainly used as a 12 V lead acid battery for automobile. And It also carried-out how it's characteristics would be changed due to aging. A mathematical modeling technique, which has been mainly used to predict behavior of Lithium-ion batteries, is applied to commercial 70 Ah VRLA battery. The modeling result of Voltage was compared with result of constant current charge / discharge test. From this, it can be seen that the NTGK model can be applied to the lead acid battery with high accuracy. It was also found that the aging of lead-acid battery can be predicted by using it.

Implementation of Microgrid using Energy Storage System (에너지 저장장치를 이용한 마이크로그리드의 구현)

  • Lee, Kye-Byung;Son, Kwang-M.;Jang, Gil-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.2
    • /
    • pp.248-254
    • /
    • 2010
  • This paper deals with implementation of the laboratory-scale microgrid using energy storage system. Also, this paper develops a simulation model of the microgrid with same parameters on the laboratory-scale microgrid using PSCAD/EMTDC. The experimental results show good agreement with the simulation results. This shows the validity of the simulation model. A valve regulated lead acid (VRLA) battery is used to store energy. Energy storage system with fast response is able to maintain power quality of sensitive load within the microgrid.

A Study on the Pb-Ca-Sn Grid Alloy of Positive Plate in Lead-Acid Battery (납축전지에서 양극판의 Pb-Ca-Sn 그리드 합금에 관한 연구)

  • Ku, Bon-Keun;Jeong, Soon-Wook
    • Journal of the Korean Applied Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.518-524
    • /
    • 2008
  • In this study, positive plates of lead acid battery of Pb-Ca alloy and Pb-Ca-Sn alloy were fabricated and the mechanical characteristics of positive plates were measured. This study observed how the changes of content of Ca & Sn affect interface corrosion which is located in between grid & active materials and lead acid batteries as well. The mechanical characteristics of grid alloy is better when Ca is 0.05 wt.% then 0.1 wt.%. This study said that the corrosion rate between the active material based on the charge/discharge cycle of lead acid battery and grid interface is much faster than a grid which contains Sn. And furthermore, according to the study the rate 30 of Sn/Ca which is added to grid shows the best performance.

The Study of Control Algorithm for Stand alone PV System (독립헝 태양광 발전 시스템의 제어 알고리즘에 관한 연구)

  • Kim, Tae-Yeop;Jung, Maeng-Hwa;Goh, Gweon-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1382-1384
    • /
    • 2002
  • The flooded type battery is used for solar lighting system. Because the characteristic of flooded type battery is the short life time, the maintenance cost is high. So the using flooded type battery in this system is inappropriate. The valve regulated lead acid batter.(VRLA) is the maintenance free and cycle service purpose. This paper presents the development of control system and monitoring system to applied VRLA battery for maintenance free and long life time in system.

  • PDF

A Study on the Valve Regulated Lead-Acid Battery using Phosphoric Acid Gel Electrolyte (인산 겔 전해질을 사용한 밀폐형 납축전지에 관한 연구)

  • Ju, Chan-Hong;Park, Keun-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.296-308
    • /
    • 2003
  • The capacity and long life of gel electrolyte batteries is connected with gas recombination producting $PbO_2$ and Pb electrode. We were prepared with phosphoric acid gel electrolyte to know gel characteristics per density to assemble VRLA batteries. We studied by measuring electrolyte dispersion using Brewster-angle microscope(BAM), charge-discharge cycle and electrode structure using scanning election microscope(SEM) per electrolyte density. As a results, phosphoric acid density 1.210 was excellent gel dispersion in sol condition, electrode condition after fifty cycles in this study.

Impedance Characteristics of the Gel Type VRLA Battery at the Various State-of-Charge (겔식 납축 전지의 충전상태에 따른 임피던스 특성 연구)

  • An, Sang-Yong;Jeong, Euh-Duck;Won, Mi-Sook;Shim, Yoon-Bo
    • Journal of the Korean Electrochemical Society
    • /
    • v.11 no.1
    • /
    • pp.33-36
    • /
    • 2008
  • In the present study, impedance spectrometry has been used for predicting State-of-Charge (SoC) of gel type, Valve Regulated Lead Acid (VRLA), battery. The impedance measurements of VRLA battery (2V/1.2 Ah) at various SoC were made over the frequency range from 100kHz to 10mHz with an amplitude 10 mV. The impedance parameters have been evaluated by the analysis of the data using an equivalent circuit and a complex non-linear least squares (CNLS) fitting method. The charge transfer resistance values and double layer capacitance values of the positive electrode were higher than those of the negative electrode. The gel resistance values increased with decreasing in SoC. This indicates that the gel resistance is an important parameter for predicting SoC of VRLA battery.