• 제목/요약/키워드: Valve performance

검색결과 1,244건 처리시간 0.028초

인공심장판막의 개발 및 동물실 (Development and Animal Tests of Artificial Heart Valves)

  • 이재영
    • Journal of Chest Surgery
    • /
    • 제20권3호
    • /
    • pp.458-472
    • /
    • 1987
  • A heart supplies bloods of about 15, 000 liters to each human organ in a day. A normal function of heart valves is necessary to this act of heart. The disease of heart valve develops to a narrowness of a closure, resulting in an abnormal circulation of bloods. In an attempt to eliminate the affliction of heart valves, the operation method to repair with artificial heart valves has been developed and saved numerous patients over past 30 years. This replacement operation has been performed since early 1960`s in Korea, but all the artificial heart valves used are imported from abroad with very high costs until recent years. The artificial heart valve using pyrolytic carbon has been developed at KAIST, which was proved to be stable in the mechanical performance and durability. Therefore, the in viva performance of this valve was examined through animal tests. The artificial heart valves used in this study are tilting disc type valves, in which the disc were made of graphite coated with pyrolytic carbon and the cages were made of titanium. In viva testings of these valves were performed in 12 dogs, in which right ventriculo-pulmonary arterial [Croup I] or inter-aortic [Croup IV] valved conduit was implanted using polytetrafluoroethylene conduits containing KAIST valve and aortic valve [Group II] or pulmonary valve [Croup III] was replaced by a KAIST valve with a 21mm or 19mm tissue annulus diameter. In group I and II, pre-and post-operative transvalvular pressure gradient was measured and compared with other prosthetic valves. During post operative period laboratory examination was performed including hemoglobin, hematocrit, red cell count, white cell, lactic acid dehydrogenase and platelet. The eight surviving dogs were sacrificed and autopsy was performed at 2, 6, and 8 weeks. KAIST valve has low transvalvular gradient and relatively high orifice area. Average ventriculo-aortic peak systolic transvalvular gradient was 14 mmHg in 21 mm valve and 19 mmHg in 19 mm valve. The valve has slight intravascular hemolysis effect. Thrombogenic effect of low polishing quality and eddy currents around small orifice is high. The valve has vulnerability of disc movement. These animal tests suggest that the improvement of the heart valve design, surface polishing state and prescription methods.

  • PDF

추진제탱크 가압용 솔레노이드밸브의 작동특성 분석 및 해석 (Analysis of Dynamic Characteristics and Performance of Solenoid Valve for Pressurization Propellant Tank)

  • 장제선;김병훈;한상엽
    • 한국추진공학회지
    • /
    • 제17권2호
    • /
    • pp.128-134
    • /
    • 2013
  • 우주발사체 추진기관 공급계에서 2-way 솔레노이드밸브는 제어시스템의 명령에 의해 추진제 탱크를 가압하여 탱크내의 압력을 조절한다. 가압용 솔레노이드밸브의 제작에 앞서 설계검증 및 기본적인 작동특성을 분석하기 위해 AMESim상용코드를 이용하여 해석모델을 수립하였다. FLUENT 상용코드를 이용하여 내부유동해석을 수행하여해 해석의 정확도를 높이고, 모델을 검증하기 위해 동특성 해석을 통해 입구압력에 따른 작동시간을 시험결과와 비교하였고 잘 일치함을 확인하였다. 또한 해석 모델을 이용하여 컨트롤밸브와 기본밸브의 설계변수에 대한 밸브의 동특성 해석을 수행하였다. 해석을 통해 기본밸브의 시트형상과 직경비에 따른 밸브의 작동시간, 작동성능, 개폐압력을 예상하였다.

이동형 국소 분무장치용 전자 밸브와 노즐 조합 작동특성 (Operating Performance of Solenoid Valve and Nozzle Sets for Target Selectable Sprayers)

  • 서상룡;김항오;김영태;최영수;유수남
    • Journal of Biosystems Engineering
    • /
    • 제31권1호
    • /
    • pp.39-45
    • /
    • 2006
  • Fundamental informations on performance of sets of solenoid valve and nozzle were necessary to develop a target selectable spraying system. The experiments were performed for the sets of solenoid valves and flat spraying nozzles at 3 levels of the operating pressures, and the obtained results are as follows; Rise time of the system pressure to reach up to 90% of the operating pressure after the valve turned was affected by nozzle size and operating pressure. Maximum overshoot of the system pressure was about 170% not affected by the sets of valve and nozzle and operating pressure. The system pressure after its settle down within 5% of the set pressure showed good uniformity in any condition of the experiment as less as 2.3% of its coefficient of variation. Time requirement to lower the system pressure down to 50% after the valve power turned off was affected by valve and nozzle set and operating pressure.

슬림라인형 가스레인지용 쿡탑형 가스 밸브의 개발과 작동 성능 검증 (The development and Performance test of the Cook Top type Gas valve for the slim-line style Gas Range)

  • 김상주;이상철;주광명;이한종;장인배
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.568-572
    • /
    • 2003
  • The height of valve body is limited to 30mm in the cook-top style gas valves for the domestic gas ranges. But the all the safety specifications of KS should be fulfilled and the magnetic power unit(MPU) should be installed in the valve body for the safety reason. The length of MPU body is longer than the 30mm that it should be located in the square direction of the knob shaft and therefore the implementation of the lever mechanism to transmit the press motion of the knob to the MPU valve is very difficult. In this paper, the hinged lever with inclined plate is used to transmit the press motion of the knob to the MPU valve. The analysis of the gas flow with using the commercial software of FLOW-3D shows that the gas flow capacity is fit for the domestic gas range. The performance and responsibility of the valve is tested for the mass production and the test results shows that the valve can be installed in the commercial gas range.

  • PDF

LNG 벙커링용 비상차단 밸브 디스크 변위 제어에 관한 연구 (Disc Displacement Control of the Emergency Shut-Down Valve for LNG Bunkering)

  • 윤진호;박주연;장지성
    • 드라이브 ㆍ 컨트롤
    • /
    • 제18권4호
    • /
    • pp.28-34
    • /
    • 2021
  • Among the currently available types of fuel, LNG emits a relatively small amount of nitrogen oxide and carbon dioxide when it burns in the engine. However, since LNG is a flammable material, leakage during bunkering can lead to accidents, such as fires. Therefore, it is necessary to install a remote operation emergency shut-down (ESD) valve to block the flow and leakage of LNG in an emergency situation that occurs during bunkering. The ESD valve uses a hydraulic driving device consisting of a hydraulic control valve and a hydraulic motor to control globe valve disc displacement, which regulates the flow path for LNG transfer. At this time, there are various nonlinearities in hydraulic driving devices; hence, it is necessary to design a controller with robust control performance against these uncertainties. In this study, modeling of the ESD valve was carried out, and a sliding mode controller to control the displacement of the globe valve disc was designed. As a result, it was confirmed that the designed control performance could be achieved by overcoming nonlinearity characteristics using the designed controller.

프리필 밸브의 거동 예측용 유압 시스템의 압력/유량 맥동 분석 (Pressure/Flow Pulsation Characteristics of the Hydraulic System for Behaviour Prediction of the Prefill Valve)

  • 박정우;하룬 아흐마드 칸;정은아;권성자;윤소남;이후승
    • 드라이브 ㆍ 컨트롤
    • /
    • 제18권2호
    • /
    • pp.1-8
    • /
    • 2021
  • In this work, a circuit with a hydraulic power unit is formulated as a means of predicting the behavior of the prefill valve in the future. The behavior of the prefill valve can be examined by the measurements of the configured power unit, and the performance is determined by using hydraulic pumps, relief valves, and hydraulic hoses that make up the power unit. In particular, pressure/flow pulsation generated by hydraulic pumps can cause instability in the prefill valve and cause noise-induced degradation of the overall performance and reliability of the hydraulic system containing the prefill valve. Therefore, to study the behavior and performance of the prefill valve in a relatively accurate manner, the prediction of the characteristics of the hydraulic power unit driving the prefill valve is very important. In this study, the pulsation characteristics of the hydraulic pump were analyzed to theoretically demonstrate its relationship with different settings of the power unit, such as relief valve pressure settings and the presence/absence of the hose.

단순 해석 모델을 이용한 밸브지지대 내진 성능 평가 (Seismic Performance Evaluation of Valve Support using Simplified FE Model)

  • 김상영;금동엽;김형은;김대진;김준호;홍성경;최원목;석창성
    • 한국안전학회지
    • /
    • 제32권1호
    • /
    • pp.60-65
    • /
    • 2017
  • In this study, a simplified FE model for evaluating seismic performance of valve support was suggested and an apparatus for a real structure testing was developed. The seismic performances of three different types of valve supports were evaluated by the real structure testing. By comparing the results between the real structure testing and FEA using the simplified FE model, it was verified that the suggested simplified FE model can be utilized for comparative evaluation of seismic performance of valve supports.

자동차용 솔레노이드 밸브의 동특성을 위한 연성해석 (Co-simulation for Dynamic Characteristic Analaysis of Solenoid Valve for Vehicle)

  • 김기찬
    • 한국산학기술학회논문지
    • /
    • 제15권6호
    • /
    • pp.3821-3826
    • /
    • 2014
  • 본 논문에서는 자동차용 솔레노이드 밸브의 전자장 해석 기반의 동특성 해석 모델을 통하여 성능을 향상시키는 방법을 제안한다. 종래의 솔레노이드 밸브의 요크와 플런저의 형상 최적설계를 통하여 저전류 고추력의 고성능 솔레노이드 모델을 도출하였다. 동특성 해석을 수행하기 위해 솔레노이드 밸브의 입력 전류 패턴을 분석하고, 이를 통해 밸브의 개폐시 속도, 추력 정보를 해석하였다. 입력 전류 패턴을 출력하는 제어로직의 회로모델과 스프링 및 댐핑 등을 고려할 수 있는 솔레노이드 밸브의 전자장 해석모델의 연동해석기반을 제안하여 입력전류 패턴의 변화가 밸브 동특성에 주는 영향을 분석할 수 있었다. 마지막으로 종래모델과 최적모델의 동특성 해석을 통하여 최적설계 모델의 성능이 개선됨을 확인하였다.

자동변속기 솔레노이드 밸브 세척기의 성능 향상에 관한 연구 (Study on Performance Improvement for Solenoid Valve Cleaner for Automatic Transmission)

  • 양형열
    • 조명전기설비학회논문지
    • /
    • 제23권5호
    • /
    • pp.1-8
    • /
    • 2009
  • 자동차의 자동변속기에는 변속을 하기 위한 솔레노이드 밸브가 장착되어 있으며, 이 솔레노이드 밸브는 자동변속기의 고장 원인 중 상당부분을 차지하므로 이 밸브를 세척하기 위하여 솔레노이드 밸브 세척기를 사용한다. 그러나 현재 사용되고 있는 세척기는 슬러지를 제거하는 효과가 적고 세척 속도가 느린 단점을 가지고 있다. 본 논문에서는 솔레노이드 오프시에 잔류전류를 신속하게 제거하여 플런저의 동작속도를 증가시킴으로써 세척력을 증가시키고 세척 속도를 빠르게 하는 방법을 제안하였으며, 그 성능을 실험을 통해 증명하였다.

스윙형 역지밸브 성능 평가 방법 (Performance Evaluation Method of a Swing Check Valve)

  • 김양석;이도환;김대웅;박성근;홍승열
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.881-886
    • /
    • 2003
  • In spite of its simple design, structure and operating mechanism, swing check valves are one of the critical components which adversely affect the safety of the nuclear power plants if they fail to function properly. Therefore, it is important to evaluate the performance condition of the swing check valves in safety-related systems. The performance characteristics of swing check valves include opening characteristics, the minimum required flow velocity, the pressure drop at design flow, the disc stability, and the effect of the upstream disturbances. Among factors to identify the performance of a swing check valve, a method to evaluate the opening characteristics and the minimum required flow velocity, which guarantees to fully open the disc and hold the disc without motion, are presented to determine the operating region of the swing check valve, such as stable, tapping, or oscillation. Based on the determined operating region and opening characteristics, the simple methods of wear and fatigue analyses of the specific parts of the valve are also described.

  • PDF