• 제목/요약/키워드: Valve control

검색결과 1,805건 처리시간 0.029초

Low-Band Type 능동형 현가제어를 위한 직동식 전자비례 감압밸브의 개발 (Development of a Direct-Operated Proportional Pressure Reducing Valve for Low-Band Type Active Suspension Control)

  • 홍예선;류시복;김영식
    • 한국자동차공학회논문집
    • /
    • 제2권3호
    • /
    • pp.75-84
    • /
    • 1994
  • In general direct-operated pressure reducing valves have been gardly applied to a dynamic control system such as active suspension control because of their poor control stability. But they are more robust than pilot-operated type and do not need pilot control flow. In this paper development of a new direct-operated proportional pressure reducing valve for low-band type active suspension control is reported. By means of a special damper directly linked to the valve spool, the control stability could be effectively improved without drawback in response time. The linearity error was less than $\pm$3.5%. Applied to an experimental active suspension system the new valve showed the $-90^{\circ}$ phase delay at 4Hz with 20% sinusoidal signal input and could control the suspension system with almost same performance as that with a pilot-operated type valve.

  • PDF

터빈 밸브시험 중 충동실 압력제어에 의한 발전기 출력변동 최소화 (The Minimization of Generator Output Variations by Impulse Chamber Pressure Control during Turbine Valve Test)

  • 최인규;김종안;박두용;우주희;신재호
    • 전기학회논문지
    • /
    • 제59권1호
    • /
    • pp.152-159
    • /
    • 2010
  • This paper describes the actual application of a feedback control loop as a means for minimizing turbine impulse chamber pressure variation during the turbine steam valve tests at a 1,000 MW nuclear power plant. The chamber pressure control loop was implemented in the new digital control system which was installed as a replacement for the old analog type control system. There has been about 40MW of the generator output change during the steam valve tests, especially the high pressure governing valve tests, because the old control system had not the impulse chamber pressure control so the operators had to compensate steam flow drop manually. The process of each valve test consists of a closing process and an reopening process and the operators can make sure that the valves are in their sound conditions by checking the valves movement. The control algorithm described in this paper contributed to keep the change in megawatt only to 6MW during the steam valve tests. Thereby, the disturbance to reactor control was reduced, and the overall plant control system's stability was greatly improved as well.

유량제어 로직 밸브에 관한 연구 ( 비례 파핏형 로직 밸브의 정특성 ) (A Study on Flow Control Logic Valve - Static Characteristics of Proportional Poppet Type Logic Valve -)

  • 이일영;정용길;오인호
    • 수산해양기술연구
    • /
    • 제26권2호
    • /
    • pp.213-217
    • /
    • 1990
  • 본 연구에서는 유량제어 조직밸브의 기초특성을 집중정수계 모델을 사용하여, 해석하고, 이것을 실험적으로 확인하였다. 그 결과를 요약하면 아래와 같다. 1. 로직밸브의 주밸브 유량은, 그것보다 매우 소유량인 파일럿 유량에 의하여 제어할 수 있다. 2. 주밸브(파핏밸브)~파일럿실간의 개구면적이 주밸브 변위에 비례하도록 밸브를 설계함으로써 주밸브변위(혹은 면적)와 부하유량사이에 양호한 직선성이 얻어진다. 3. 유량제어 로직밸브에서 주밸브 유량의 제어범위의 상한은 기름홈의 개구면적의 최대치에 의하여 결정한다.

  • PDF

A Study on the Control Characteristics of ER Valve-FHA System and Durability Test

  • Jang Sung-Cheol;Chang Tae-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • 제19권8호
    • /
    • pp.1621-1631
    • /
    • 2005
  • In this paper, making the best use of the features of the electro-rheological (ER) valve, a two-port pressure control valve using ER fluids is proposed and manufactured. The ER-Valve characteristics are evaluated by changing the intensity of the electric field and the number of electrode. As only with electrical signal change to the ER-Valve in which ER fluid flowing, ER fluid flow is controlled, so development of simple ER-Valves have been tried. The ER-Valves and pressure drop check method are considered to be applied to the fluid power industry. Using the manufactured pressure control valve, a one-link manipulator with FHA (Flexible Hydraulic Actuator) is driven. As a result, it is experimentally confirmed that the pressure control valve using ER fluids is applicable to use in driving actuator. If it applies characteristics of the ER fluids, it will be able to apply in the control system for the ER Valve which occurs from industrial controller. After having durability test, shear stress increased regularly because of starch particles crushed by pump and particle size that was almost the same. Moreover, Ra of copper electrode increased about 1.56 times rather than before those of performing durability test, and Rz increased about 2.2 times.

펌프제어밸브를 사용한 취수펌프장에서의 수격현상 (Waterhammer for the Intake Pumping Station with the Pump Control Valve)

  • 김경엽;오상현
    • 한국유체기계학회 논문집
    • /
    • 제4권4호
    • /
    • pp.16-21
    • /
    • 2001
  • The field tests on the waterhammer were carried out for PalDang intake pumping station of the metropolitan water supply 5th stage project. The pumping station was equipped with the pump control valve as the main surge suppression device and the surge relief valve as auxiliary. However, the pump control valve had not been early controlled in the planned closing mode, and the slamming occurred to the valve which abruptly closed during the large reverse flow. Because the pressure wave caused by the pump failure was superposed on the slam surge, the upsurge increased so extremely that the shaft of the valve was damaged. It was desirable that the surge relief valve was installed in the pumping station or near the pump exit for the delay of response. After reforming the oil dashpot of the pump control valve, the sliming disappeared and the measured pressure was in fairly good agreement with the results of simulation. In case of three pumps for ${\phi}2,600$ pipeline being simultaneously tripped, the pressure head in the pumping station increased to 95.6 m, and the upsurge caused by the emergency stop of four pumps for ${\phi}2,800$ pipeline was 89.6m. We concluded that the pumping station acquired the safety and reliability for the pressure surge.

  • PDF

A Study on the Development of Mathematical Model of Three-stage Flow Control Valve

  • Khan, Haroon Ahmad;Kang, Chang Nam;Yun, So Nam
    • 드라이브 ㆍ 컨트롤
    • /
    • 제15권2호
    • /
    • pp.38-45
    • /
    • 2018
  • In this study, the theory of fluid mechanics and dynamics is used to build a mathematical model for a three-stage flow control valve. The significance of the study is that the mathematical model can easily be used to study the effect of different design parameters on the performance of the valve. The geometry of the valve and the properties of the fluid were used in this study to determine the variation in the performance of the valve when varying the magnetic force on the pilot spool. While a linearization technique is not used to solve the developed model, the solution of the mathematical model is found in the time domain by simulation of the equations using a software package. The results indicate that if the developed mathematical model is solved for the different values of magnetic force, the valve behaves linearly; the valve is thus called the proportional flow control valve.

A Two-Dimensional Study of Transonic Flow Characteristics in Steam Control Valve for Power Plant

  • Yonezawa, Koichi;Terachi, Yoshinori;Nakajima, Toru;Tsujimoto, Yoshinobu;Tezuka, Kenichi;Mori, Michitsugu;Morita, Ryo;Inada, Fumio
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권1호
    • /
    • pp.58-66
    • /
    • 2010
  • A steam control valve is used to control the flow from the steam generator to the steam turbine in thermal and nuclear power plants. During startup and shutdown of the plant, the steam control valve is operated under a partial flow conditions. In such conditions, the valve opening is small and the pressure deference across the valve is large. As a result, the flow downstream of the valve is composed of separated unsteady transonic jets. Such flow patterns often cause undesirable large unsteady fluid force on the valve head and downstream pipe system. In the present study, various flow patterns are investigated in order to understand the characteristics of the unsteady flow around the valve. Experiments are carried out with simplified two-dimensional valve models. Two-dimensional unsteady flow simulations are conducted in order to understand the experimental results in detail. Scale effects on the flow characteristics are also examined. Results show three types of oscillating flow pattern and three types of static flow patterns.

파이로트 구동용 압력제어밸브의 특성 해석 (Characteristics Analysis of Pilot Operated Pressure Control Valve)

  • 윤소남;최영호;함영복;김광영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.725-728
    • /
    • 2002
  • In this Paper, a mathematical model describing the dynamics of pilot operated pressure control valve was derived. A attempt to analyze the Parameters(seat diameter, cone angle, spring stiffness, control volume) which relate to the performance of the object valve was carried out. Simulation using AMESim as a simulation tool was operated, and verified the validity of our simulation by means of comparison our simulation results with an experimental results of the pilot operated pressure control valve.

  • PDF

하이브리드 상용차용 경량 비상조향장치 유압방향제어밸브의 성능특성 연구 (Characteristics of Lightweight Hydraulic Directional Control Valve for Emergency Steering in Hybrid Electric Commercial Vehicles)

  • 박경민
    • Tribology and Lubricants
    • /
    • 제29권5호
    • /
    • pp.291-297
    • /
    • 2013
  • Hydraulic directional control valves actuated by solenoid are used to control emergency steering in general or hybrid electric commercial vehicles. In this study, a new lightweight hydraulic directional control valve was designed by flow and structural simulation, and was fabricated; the basic operation, pressure differentials, and inner leakage flow were evaluated experimentally. In the results, the new model showed comparable performance with an existing imported valve. New valve was 80% the weight of the existing valve and had few components. Installing this valve on a truck body is easier because of its compactness and small size.

압력제어용 DDV를 이용한 전기.유압 서보시스템의 식별 및 제어 (Identification and Control of a Electro-Hydraulic Servo System Using a Direct Drive Valve)

  • 이창돈;이상훈;곽동훈;이진걸
    • 제어로봇시스템학회논문지
    • /
    • 제9권2호
    • /
    • pp.124-130
    • /
    • 2003
  • The electro-hydraulic servo system with a servo valve is applied widely in force control. However, the composition of control system using a servo valve is difficult due to nonlinearities in the servo valve, such as square-root terms in flow equation. The electro-hydraulic servo system using a DDV(Direct Drive Valve) instead of a servo valve was proposed and it's characteristics was estimated. The DDV and whole system are modelled by parameter identification using the input-and-output data, then the models are verified by the comparison of simulation with experiment. Also, the state feedback controller has been designed based on this model, then the performance of the electro-hydraulic force servo system using a DDV is evaluated by simulation and experimental results.