• Title/Summary/Keyword: Valve body

Search Result 235, Processing Time 0.245 seconds

Vasopressin in Young Patients with Congenital Heart Defects for Postoperative Vasodilatory Shock (선천성 심장병 수술 후 발생한 혈관확장성 쇼크에 대한 바소프레신의 치료)

  • 황여주;안영찬;전양빈;이재웅;박철현;박국양;한미영;이창하
    • Journal of Chest Surgery
    • /
    • v.37 no.6
    • /
    • pp.504-510
    • /
    • 2004
  • Background: Vasodilatory shock after cardiac surgery may result from the vasopressin deficiency following cardio-pulmonary bypass and sepsis, which did not respond to usual intravenous inotropes. In contrast to the adult patients, the effectiveness of vasopressin for vasodilatory shock in children has not been known well and so we reviewed our experience of vasopressin therapy in the small babies with a cardiac disease. Material and Method: Between February and August 2003, intravenous vasopressin was administrated in 6 patients for vasodilatory shock despite being supported on intravenous inotropes after cardiac surgery. Median age at operation was 25 days old (ranges; 2∼41 days) and median body weight was 2,870 grams (ranges; 900∼3,530 grams). Preoperative diag-noses were complete transposition of the great arteries in 2 patients, hypoplastic left heart syndrome in 1, Fallot type double-outlet right ventricle in 1, aortic coarctation with severe atrioventricular valve regurgitation in 1, and total anomalous pulmonary venous return in 1. Total repair and palliative repair were undertaken in each 3 patient. Result: Most patients showed vasodilatory shock not responding to the inotropes and required the vasopressin therapy within 24 hours after cardiac surgery and its readministration for septic shock. The dosing range for vasopressin was 0.0002∼0.008 unit/kg/minute with a median total time of its administration of 59 hours (ranges; 26∼140 hours). Systolic blood pressure before, 1 hour, and 6 hours after its administration were 42.7$\pm$7.4 mmHg, 53.7$\pm$11.4 mmHg, and 56.3$\pm$13.4 mmHg, respectively, which shows a significant increase in systolic blood pressure (systolic pressure 1hour and 6 hours after the administration compared to before the administration; p=0.042 in all). Inotropic indexes before, 6 hour, and 12 hours after its administration were 32.3$\pm$7.2, 21.0$\pm$8.4, and 21.2$\pm$8.9, respectively, which reveals a significant decrease in inotropic index (inotropic indexes 6 hour and 12 hours after the administration compared to before the administration; p=0.027 in all). Significant metabolic acidosis and decreased urine output related to systemic hypoperfusion were not found after vasopressin admin- istration. Conclusion: In young children suffering from vasodilatory shock not responding to common inotropes despite normal ventricular contractility, intravenous vasopressin reveals to be an effective vasoconstrictor to increase systolic blood pressure and to mitigate the complications related to higher doses of inotropes.

Analysis of the Causes of and Risk Factors for Mortality in the Surgical Repair of Interrupted Aortic Arch (대동맥궁 단절증 수술 사망 원인과 위험인자 분석)

  • Kwak Jae Gun;Ban Ji Eun;Kim Woong-Han;Jin Sung Hoon;Kim Yong Jin;Rho Joon Ryang;Bae Eun Jung;Noh Chung Il;Yun Yong Soo;Lee Jeong Ryul
    • Journal of Chest Surgery
    • /
    • v.39 no.2 s.259
    • /
    • pp.99-105
    • /
    • 2006
  • Background: Interrupted aortic arch is a rare congenital heart anomaly which still shows high surgical mortality. In this study, we investigated the causes of and the risk factors for mortality to improve the surgical outcomes for this difficult disease entity. Material and Method: From 1984 to 2004, 42 patients diagnosed as IAA were reviewed retrospectively. Age, body weight at operation, preoperative diagnosis, preoperative PGE1 requirement, type of interrupted aortic arch, degree of left ventricular outflow stenosis, CPB time, and ACC time were the possible risk factors for mortality. Result: There were .14 hospital deaths. Preoperative use of PGE1, need for circulartory assist and aortic cross clamp time proved to be positive risk factors for mortality on univariate analysis. Preoperative left ventricular outflow stenosis was considered a risk factor for mortality but it did not show statistical significance (p-value=0.61). Causes of death included hypoxia due to pulmonary banding, left ventricular outtract stenosis, infection, mitral valve regurgitation, long cardiopulmonary bypass time and failure of coronary transfer failure in TGA patients. Conclusion: In this study, we demonstrated that surgical mortality is still high due to the risk factors including preoperative status and long operative time. However preoperative subaortic dimension was not related statistically to operative death statistically. Adequate preoperative management and short operation time are mandatory for better survival outcome.

An Optimization Method of Measuring Heart Position in Dynamic Myocardial Perfusion SPECT with a CZT-based camera (동적 심근관류 SPECT에서 심장의 위치 측정방법에 대한 고찰)

  • Seong, Ji Hye;Lee, Dong Hun;Kim, Eun Hye;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.75-79
    • /
    • 2019
  • Purpose Cadmium-zinc-telluride (CZT) camera with semiconductor detector is capable of dynamic myocardial perfusion SPECT for coronary flow reserve (CFR). Image acquisition with the heart positioned within 2 cm in the center of the quality field of view (QFOV) is recommended because the CZT detector based on focused multi-pinhole collimators and is stationary gantry without rotation. The aim of this study was to investigate the optimal method for measuring position of the heart within the center of the QFOV when performing dynamic myocardial perfusion SPECT with the Discovery NM 530c camera. Materials and Methods From June to September 2018, 45 patients were subject to dynamic myocardial perfusion SPECT with D530c. For accurate heart positioning, the patient's heart was scanned with a mobile ultrasound and marked at the top of the probe where the mitral valve (MV) was visible in the parasternal long-axis view (PLAX). And, the marked point on the patient's body matched with the reference point indicated CZT detector in dynamic stress. The heart was positioned to be in the center of the QFOV in rest. The coordinates of dynamic stress and rest were compared statistically. Results The coordinates of the dynamic stress using mobile ultrasound and those taken of the rest were recorded for comparative analysis with regard to the position of the couch and analyzed. There were no statistically significant differences in the coordinates of Table in & out, Table up & down, and Detector in & out (P > 0.05). The difference in distance between the 2 groups was measured at $0.25{\pm}1.00$, $0.24{\pm}0.96$ and $0.25{\pm}0.82cm$ respectively, with no difference greater than 2 cm in all categories. Conclusion The position of the heart taken using mobile ultrasound did not differ significantly from that of the center of the QFOV. Therefore, The use of mobile ultrasound in dynamic stress will help to select the correct position of the heart, which will be effective in clinical diagnosis by minimizing the image quality improvement and the patient's exposure to radiation.

Development of control system for complex microbial incubator (복합 미생물 배양기의 제어시스템 개발)

  • Hong-Jik Kim;Won-Bog Lee;Seung-Ho Lee
    • Journal of IKEEE
    • /
    • v.27 no.1
    • /
    • pp.122-126
    • /
    • 2023
  • In this paper, a control system for a complex microbial incubator was proposed. The proposed control system consists of a control unit, a communication unit, a power supply unit, and a control system of the complex microbial incubator. The controller of the complex microbial incubator is designed and manufactured to convert analog signals and digital signals, and control signals of sensors such as displays using LCD panels, water level sensors, temperature sensors, and pH concentration sensors. The water level sensor used is designed and manufactured to enable accurate water level measurement by using the IR laser method with excellent linearity in order to solve the problem that existing water level sensors are difficult to measure due to foreign substances such as bubbles. The temperature sensor is designed and used so that it has high accuracy and no cumulative resistance error by measuring using the thermal resistance principle. The communication unit consists of two LAN ports and one RS-232 port, and is designed and manufactured to transmit signals such as LCD panel, PCT panel, and load cell controller used in the complex microbial incubator to the control unit. The power supply unit is designed and manufactured to supply power by configuring it with three voltage supply terminals such as 24V, 12V and 5V so that the control unit and communication unit can operate smoothly. The control system of the complex microbial incubator uses PLC to control sensor values such as pH concentration sensor, temperature sensor, and water level sensor, and the operation of circulation pump, circulation valve, rotary pump, and inverter load cell used for cultivation. In order to evaluate the performance of the control system of the proposed complex microbial incubator, the result of the experiment conducted by the accredited certification body showed that the range of water level measurement sensitivity was -0.41mm~1.59mm, and the range of change in water temperature was ±0.41℃, which is currently commercially available. It was confirmed that the product operates with better performance than the performance of the products. Therefore, the effectiveness of the control system of the complex microbial incubator proposed in this paper was demonstrated.

Mid-term results of IntracardiacLateral Tunnel Fontan Procedure in the Treatment of Patients with a Functional Single Ventricle (기능적 단심실 환자에 대한 심장내 외측통로 폰탄술식의 중기 수술성적)

  • 이정렬;김용진;노준량
    • Journal of Chest Surgery
    • /
    • v.31 no.5
    • /
    • pp.472-480
    • /
    • 1998
  • We reviewed the surgical results of intracardiac lateral tunnel Fontan procedure for the repair of functional single ventricles. Between 1990 and 1996, 104 patients underwent total cavopulmonary anastomosis. Patients' age and body weight averaged 35.9(range 10 to 173) months and 12.8(range 6.5 to 37.8) kg. Preoperative diagnoses included 18 tricuspid atresias and 53 double inlet ventricles with univentricular atrioventricular connection and 33 other complex lesions. Previous palliative operations were performed in 50 of these patients, including 37 systemic to pulmonary artery shunts, 13 pulmonary artery bandings, 15 surgical atrial septectomies, 2 arterial switch procedures, 2 resections of subaortic conus, 2 repairs of total anomalous pulmonary venous connection and 1 Damus-Stansel-Kaye procedure. In 19 patients bidirectional cavopulmonary shunt operation was performed before the Fontan procedure and in 1 patient a Kawashima procedure was required. Preoperative hemodynamics revealed a mean pulmonary artery pressure of 14.6(range 5 to 28) mmHg, a mean pulmonary vascular resistance of 2.2(range 0.4 to 6.9) wood-unit, a mean pulmonary to systemic flow ratio of 0.9(range 0.3 to 3.0), a mean ventricular end-diastolic pressure of 9.0 (range 3.0 to 21.0) mmHg, and a mean arterial oxygen saturation of 76.0(range 45.6 to 88.0)%. The operative procedure consisted of a longitudinal right atriotomy 2cm lateral to the terminal crest up to the right atrial auricle, followed by the creation of a lateral tunnel connecting the orifices of either the superior caval vein or the right atrial auricle to the inferior caval vein, using a Gore-Tex vascular graft with or without a fenestration. Concomitant procedures at the time of Fontan procedure included 22 pulmonary artery angioplasties, 21 atrial septectomies, 4 atrioventricular valve replacements or repairs, 4 corrections of anomalous pulmonary venous connection, and 3 permanent pacemaker implantations. In 31, a fenestration was created, and in 1 an adjustable communication was made in the lateral tunnel pathway. One lateral tunnel conversion was performed in a patient with recurrent intractable tachyarrhythmia 4 years after the initial atriopulmonary connection. Post-extubation hemodynamic data revealed a mean pulmonary artery pressure of 12.7(range 8 to 21) mmHg, a mean ventricular end-diastolic pressure of 7.6(range 4 to 12) mmHg, and a mean room-air arterial oxygen saturation of 89.9(range 68 to 100) %. The follow-up duration was, on average, 27(range 1 to 85) months. Post-Fontan complications included 11 prolonged pleural effusions, 8 arrhythmias, 9 chylothoraces, 5 of damage to the central nervous system, 5 infectious complications, and 4 of acute renal failure. Seven early(6.7%) and 5 late(4.8%) deaths occured. These results proved that the lateral tunnel Fontan procedure provided excellent hemodynamic improvements with acceptable mortality and morbidity for hearts with various types of functional single ventricle.

  • PDF