• Title/Summary/Keyword: Valve Opening Characteristics

검색결과 175건 처리시간 0.022초

유압식 동력 조향기어 박스에서 설계변수의 특성검토 (Characteristic Investigation of Design Parameters on the Hydraulic Power Steering Gear Box)

  • 장주섭;윤영환
    • 한국자동차공학회논문집
    • /
    • 제16권4호
    • /
    • pp.135-142
    • /
    • 2008
  • Hydraulic power steering system has been adopted in seniority passenger and commercial vehicle system for an easy maneuverability and a smoother ride. In this study, hydraulic power steering system analysis model which includes hydraulics and mechanical sub-systems was developed using commercial software, AMESim in order to predict characteristics for various steering components. Each component which constructs system was modeled and verified by experimentally obtained characteristics curves of each components. The parameter sensitivity analysis such as valve opening area, torsional stiffness of torsion bar for system design are carried out by the analysis and experimental method. The predicted results by the development model were a good agreement with experimentally obtained results. The sensitivity investigation results rotary torque when changing an input shaft edge width, was most sensitive, to change in angle and slot width and supply flow of input shaft edge is not a lot sensitively.

고속철도 터널에서 발생하는 파동현상에 관한 충격파관의 연구(1) - 압축파의 특성에 대하여 - (Study of Shock Tube for Wave Phenomenon in High Speed Railway Tunnel(1) - On the characteristics of Compression Wave -)

  • 김희동
    • 대한기계학회논문집
    • /
    • 제18권10호
    • /
    • pp.2686-2697
    • /
    • 1994
  • When a railway train enters a tunnel at high speed, a compression wave is formed in front of the train and propagates along the tunnel. The compression wave subsequently emerges from the exit of the tunnel, which causes an impulsive noise. In order to estimate the magnitudes of the noises and to effectively minimize them, the characteristics of the compression wave propagating in a tunnel must be understood. In the present paper, the experimental and analytical investigations on the attenuation and distortion of the propagating compression waves were carried out using a model tunnel. This facility is a kind of open-ended shock tube with a fast-opening gate valve instead of a general diaphragm. One-dimensional flow model employed in the present study could appropriately predict the strength of the compression wave, Mach number and flow velocity induced by the compression wave. The experimental results show that the strength of a compression wave decreases with the distance from the tunnel entrance. The decreasing rate of the wave strength and pressure gradient in the wave is strongly dependent on the strength of the initial compression wave at the tunnel entrance.

250마력 급 차량용 터보차저 서지현상에 대한 실험적 연구 (Experimental Study of Compressor Surge for 250-hp Class Vehicular Turbocharger)

  • 이형창;한재영;이명희;임석연;유상석
    • 대한기계학회논문집B
    • /
    • 제39권1호
    • /
    • pp.89-95
    • /
    • 2015
  • 터보압축기의 서지는 압축기의 불안정 운전영역으로 주로 소음과 맥동을 유발하며 수회 지속될시 압축기 시스템 전반에 걸쳐 막대한 피해를 입힌다. 압축기의 안전한 운전을 위해서는 서지현상에 대한 특성파악과 제어전략 수립이 중요하다. 서지현상의 제어는 주로 압축가스의 통과유동량 증대, 필요한 헤드 저감, 압축기 회전수 감속, 가스의 바이패스를 통하여 이루어진다. 본 연구에서는 차량용 터보차저에 서지를 유발했을 때 각 운전 구간별 발생되는 압력변동 특성을 연구하고자 한다. 서지 특성 확인을 위한 파라미터는 압축기 입구 유량과 출구 유량, 관경, 회전수 등으로 선정하였다. 입구단과 출구단 유량을 조절하여 서지 압력 변동을 조사한 결과, 출구단 보다는 입구단 유량의 급격한 변화가 서지와 압축기 내구에 더 영향이 크다는 것을 확인하였다.

Pulsatile Blood Flows Through a Bileaflet Mechanical Heart Valve with Different Approach Methods of Numerical Analysis : Pulsatile Flows with Fixed Leaflets and Interacted with Moving Leaflets

  • Park, Choeng-Ryul;Kim, Chang-Nyung;Kwon, Young-Joo;Lee, Jae-Won
    • Journal of Mechanical Science and Technology
    • /
    • 제17권7호
    • /
    • pp.1073-1082
    • /
    • 2003
  • Many researchers have investigated the blood flow characteristics through bileaflet mechanical heart valves using computational fluid dynamics (CFD) models. Their numerical approach methods can be classified into three types; steady flow analysis, pulsatile flow analysis with fixed leaflets, and pulsatile flow analysis with moving leaflets. The first and second methods have been generally employed for two-dimensional and three-dimensional calculations. The pulsatile flow analysis interacted with moving leaflets has been recently introduced and tried only in two-dimensional analysis because this approach method has difficulty in considering simultaneously two physics of blood flow and leaflet behavior interacted with blood flow. In this publication, numerical calculation for pulsatile flow with moving leaflets using a fluid-structure interaction method has been performed in a three-dimensional geometry. Also, pulsatile flow with fixed leaflets has been analyzed for comparison with the case with moving leaflets. The calculated results using the fluid-structure interaction model have shown good agreements with results visualized by previous experiments. In peak systole. calculations with the two approach methods have predicted similar flow fields. However, the model with fixed leaflets has not been able to predict the flow fields during opening and closing phases. Therefore, the model with moving leaflets is rigorously required for advanced analysis of flow fields.

상수도관로 누수신호의 특성 분석을 위한 누수 실험시설 개발 (Development of leakage test facility for leak signal characteristic analysis in water pipeline)

  • 박상혁;곽필재;이현동;최창호
    • 상하수도학회지
    • /
    • 제31권5호
    • /
    • pp.459-469
    • /
    • 2017
  • A real scale leakage test facility was developed to study the leak signal characteristics of water supply pipelines, and then leak tests were carried out. The facility was designed to overcome the limited experimental circumstances of domestic water supply pipeline experimental facilities. The length of the pipeline, which was installed as a straight line, is 280m. Six pipes were installed on a 70m interval with different pipe material and diameters that are DCIP(D200, D150, D100, D80), PE(D75) and PVC(D75).The intensity of the leakage is adjusted by changing the size of the leak hole and the opening rate of ball valve. Various pressure conditions were simulated using a pressure reducing valve.To minimize external noise sources which, deteriorate the quality of measured leak signal, the facility was built at a quiet area, where traffic and water consumption by customers is relatively rare. In addition, the usage of electric equipment was minimized to block out noise and the facility was operated using manual mode. From the experimental results of measured leakage signal at the facility, it was found that the signal intensity weakened and the signal of high frequency band attenuated as the distance from the water leakage point increased.

The Characteristics of the Appearance and Health Risks of Volatile Organic Compounds in Industrial (Pohang, Ulsan) and Non-Industrial (Gyeongju) Areas

  • Jung, Jong-Hyeon;Choi, Bong-Wook;Kim, Mi-Hyun;Baek, Sung-Ok;Lee, Gang-Woo;Shon, Byung-Hyun
    • Environmental Analysis Health and Toxicology
    • /
    • 제27권
    • /
    • pp.12.1-12.8
    • /
    • 2012
  • Objectives: The aim of this study was to identify the health and environmental risk factors of air contaminants that influence environmental and respiratory diseases in Gyeongju, Pohang and Ulsan in South Korea, with a focus on volatile organic compounds (VOCs). Methods: Samples were collected by instantaneous negative pressure by opening the injection valve in the canister at a fixed height of 1 to 1.5 m. The sample that was condensed in $-150^{\circ}C$ was heated to $180^{\circ}C$ in sample pre-concentration trap using a 6-port switching valve and it was injected to a gas chromatography column. The injection quantity of samples was precisely controlled using an electronic flow controller equipped in the gas chromatography-mass spectrometer. Results: The quantity of the VOC emissions in the industrial area was 1.5 to 2 times higher than that in the non-industrial area. With regards to the aromatic hydrocarbons, toluene was detected at the highest level of 22.01 ppb in Ulsan, and chloroform was the halogenated hydrocarbons with the highest level of 10.19 ppb in Pohang. The emission of toluene was shown to be very important, as it accounted for more than 30% of the total aromatic hydrocarbon concentration. Conclusions: It was considered that benzene in terms of the cancer-causing grade standard, toluene in terms of the emission quantity, and chloroform and styrene in terms of their grades and emission quantities should be selected for priority measurement substances.

캐스캐이드형 연료전지 모듈 벤트 로직 최적화 (Optimization of Vent Logic for Cascade Type Fuel Cell Module)

  • 임종구;박종철;권기욱;신현길
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.87.2-87.2
    • /
    • 2011
  • Many type of fuel cell stacks have been developed to improve the efficiency of reactants usage. The cascade type fuel cell stack using dead end operation is able to attain above 99% usage of hydrogen and oxygen. It is sectionalized to several parts and the residual reactants which are used previous parts would be supplied again to next parts which have less number of cells in dead end operation stack. The oversupply of reactants which is usually 120%~150% of the theoretical amount to generate current for preventing the flooding effect could be provided to each part except the last one. The final section which is called monitoring cells is supposed to be supplied insufficient the fuel or oxidant that would have some accumulated inert gas from former parts. It makes some voltage drop in the part and the fresh reactants must be supplied to the part for recovering it by venting the residual gas. So the usage of fuel and oxidant is depend on the time and frequency of opening valves for venting of residual gas and it is important to optimize the vent logic for achieving higher usage of hydrogen and oxygen. In this research, many experiments are performed to find optimal condition by evaluating the effect of time and frequency under several power conditions using over 100kW class fuel cell module. And the characteristics of the monitoring cells are studied to know the proper cell voltage which decide the condition of opening the vent valve for stable performance of the cascade type fuel cell module.

  • PDF

SEBIM POSRV 방출배관계통의 수력학적 하중계산을 위한 RELAP5 / MOD3 분석 (RELAP5/MOD3 Analysis for Hydraulic Load Calculation of the SEBIM POSRV Discharge Riping System)

  • Han, Kee-Soo;Song, Jin-Ho
    • Nuclear Engineering and Technology
    • /
    • 제26권2호
    • /
    • pp.225-236
    • /
    • 1994
  • SEBIM 밸브 상부에 위치한 밀봉수의 급격한 방출은 밸브 후단의 방출배관계통에 큰 운동량과 관성력의 작용을 초래한다. 본 연구는 밸브개방시 방출배관계통의 후단에 발생하는 열수력학적 과도현상을 분석하기 위한 해석절차 및 해석결과를 다루고 있으며, 이 분석을 위해 RELAP5 /MOD3 를 사용하였다. RELAP5 /MOD3 분석을 위하여, 방출관 계통과 SEBIM 밸브의 개방특성 및 밀봉수 방출등의 적절한 모델방법이 제시되었다. 또한 접합부(junction)와 체적(volume)의 제어 플래그 (flag)에서 옵션(option)의 적절한 선택을 위하여 민감도분석도 수행되었다. 분석결과, SEBIM 밸브 방출배관계통의 밀봉수 방출에 따른 열수력학적 과도현상을 분석하는데 RELAP5 /MOD3가 적절히 사용될 수 있음을 알 수 있었다. 민감도 분석결과로부터, 밀봉수 방출해석을 위해서는 적절한 기하학적 압력분포를 가지는 완만한(smooth) 면적변화 및 비평형 옵션(option), 적절한 시간간격(time step)의 사용이 필수적인 것을 알 수 있었다.

  • PDF

100kW급 연료전지 열관리 시스템 실도로 운전조건 해석적 연구 (Analytic study on thermal management operating conditions of balance of 100kW fuel cell power plant for a fuel cell electric vehicle)

  • 이호성;이무연;조중원
    • 한국산학기술학회논문지
    • /
    • 제20권2호
    • /
    • pp.1-6
    • /
    • 2019
  • 본 연구의 목적은 100kW급 연료전지 시스템의 열관리 성능을 실도로 운전조건에서 분석하여, 성능 해석 모델링을 개발하는 것이다. 개발된 모델을 적용하여, 열관리 시스템의 운전조건 변화에 따른 성능 변화를 고찰하고자 한다. 해석 모델링은 핵심부품들에 대한 성능 평가 데이터를 바탕으로, 성능에 영향을 주는 변수들로 개발하였다. 개발된 연료전지 열관리 시스템 해석 모델링으로 다양한 실차 운전조건에서의 최적 열관리 시스템에 대한 전력소비량을 분석하였다. 주요하게, 연료전지 열관리시스템 핵심부품(워터펌프, 냉각 팬, 3 Way Valve, 라디에이터)에 대한 성능 특성 분석 후 모델링을 진행하였다. 개발된 모델링으로 운전조건에 따른 유량 예측을 하였고, 실험값과 예측값과의 비교분석을 통하여서, 해석 모델링에 대한 검증을 진행하였다. 과도해석을 통하여서, 냉시동시 냉각수 온도가 특정온도까지의 소요시간을 예측하였다. 스택 운전조건에서 스택 입출구 온도가 적정 수준에서 움직이기 위한 열관리 시스템 운전조건에 대한 예측을 진행하였다. 그 결과를 바탕으로, 소모전력과 열방출량과의 비교분석을 하였다. 개발된 해석 모델링은 핵심부품들의 성능 변화시 연료전지 시스템 운전에 대한 영향도를 분석할 수 있도록 활용할 예정이다.

자동차용 기관의 냉각수 온도조절 최적화에 관한 연구(I) (A Study on the Optimum Cooling Water Temperature Control of an Automotive Engine(I))

  • 박경석;신진식;이경우
    • 오토저널
    • /
    • 제14권2호
    • /
    • pp.34-43
    • /
    • 1992
  • The purpose of this study is to consider the performance and exhaust characteristics in the practical engine according to the cooling water temperature change of engine and to set up the optimum cooling condition and to obtain the optimum operating condition of thermostat in the cooling system. In order to accomplish the purpose of this study, authors have used the following procedure. 1. This study is to investigate the influence of the cooling water temperature on the engine performance and the exhaust gas, authors regulated the cooling water temperature by using the special closing circuit and measured the concentration of exhaust gas by using the exhaust gas measuring system in the exhaust pipe. 2. This study carried out the experiment by regulating the opening degree of throttle valve and engine speed in the dynamometer and by changing the cooling water temperature, at the same time kept air-fuel ratio constant and made the spark ignition time MBT(Minimum spark advance for Best Torque) 3. This study measured the cooling water temperature by using the K-type thermocouple centring around the easy over-heated parts and by installing a special closing circuit. Therefore, in this study, authors intend to examine the influence of the cooling water temperature on the engine performance, exhaust gas and present the basic materials needed in the engine design including the optimum operating time control system for the cooling water temperature.

  • PDF