• Title/Summary/Keyword: Valve Material

Search Result 407, Processing Time 0.022 seconds

A Study on the Forming Analysis of the 2 Cavity Die Casting for Automobile Valve Housing (자동차용 밸브 하우징의 2 캐비티 다이캐스팅 성형해석에 관한 연구)

  • Lee, Jong-Hyung;Yi, Chang-Heon;Lee, Sang-Young;Ha, Hong-Bae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.5 no.2
    • /
    • pp.27-35
    • /
    • 2006
  • Al used in automobiles is mostly material, and according to the innovation of technique is in rapid development. Al die casting is an important field as today's trend of lightweight on automobiles. Valve housing in steering system improves driver's controling. The valve housing which is widely reliable to the most automobiles are developed this moment in our automobile industry. Therefore, they are produced by casting method which cost three times or even more expensive in production. If valve housing which is a part of steering system is produced by gravity casting, the space for manufacturing equipment will be increased, and more time and workers would be brought into service. For such reason, die casting would replace gravity casting in order to minimize cost of time, manpower, and working space. This study is the forming analysis of the 2 cavity die casting for automobile valve housing.

  • PDF

Improving the Reliability of a Reciprocating Compressor for Applications in a Refrigerator

  • Woo, Seong-Woo;Chu, Yong-Ho;Ahn, Haeng-Keun
    • Korean Journal of Materials Research
    • /
    • v.17 no.11
    • /
    • pp.580-586
    • /
    • 2007
  • To enhance the reliability of a newly designed reciprocating compressor applied in a domestic compressor, accelerated life tests were developed using new definitions of the sample size and the $B_1$ life index. In $1^{st}$ accelerated life testing, the compressor was locked due to the fracture of the suction reed valve. The failure modes and mechanisms of the suction reed valve in the accelerated tests were found to be similar to that of the failed product in the field. The root cause of the failure was the overlap between the suction reed valve and the valve plate in the suction port. The missing parameters in the design phase were modified by expanding the trespan size, introducing tumbling process, changing the material and thickness for the valve, introducing a ball peening and brushing process for the valve plate. In $2^{nd}$ accelerated life testing, the compressor was locked due to the interference between the crank shaft and thrust washer. The corrective plan was to heat treat the crank shaft. The $B_1$ life of the compressor improved from 1.5 to 12.9 years.

An Experimental Study of Valve Seat Material Galling Characteristics in Waterworks

  • Park, Sung-Jun;Kim, Young-Tae;Lee, Sang-Jo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.8 no.1
    • /
    • pp.46-51
    • /
    • 2007
  • Environmental contamination creates shortages of potable water. In such situations, the leakage of water due to breakage or aging of rubber valve seats is a serious problem. Rubber is apt to break when it is placed between two materials that contact each other. One way to avoid water leakage due to rubber damage and breakdown is to replace the rubber with metal, which is currently taking place in water distribution systems. In tribology, a severe form of wear is characterized by local macroscopic material transfer or removal, or by problems with sliding protrusions when two solid surfaces experience relative sliding under load. One of the major problems when metal slides is the occurrence of galling. Experimentally, various conditions influence incipient galling, such as hardness, surface roughness, temperature, load, velocity, and the external environment. This study sought to verify the galling tendencies of metal according to its hardness, surface roughness, load, and sliding velocity, and determine the quantitative effect of each factor on the galling tendencies.

Characteristics of High Temperature Fatigue for welding material by Plasma Transferred Arc Weld (플라즈마 분말 용접재의 고온피로특성)

  • Choi, Seong-Dae;Cheong, Seon-Hwan;Kweon, Hyun-Kyu;Kim, Gi-Man;Kim, Jam-Kyu
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.6 no.3
    • /
    • pp.92-97
    • /
    • 2007
  • The overlay welding the automobile where the durability is demanded, it is used in the vessel engine valve, plant valve and pump parts. Cause of damage public opinion one what is thought is the fatigue load due to the opening and shutting operation right time repetition of the engine valve. The damage cause of the engine valve or explanation of destruction mechanism is very difficult. The research which it sees to make clear a overlay welding of Co-alloy by Plasma Transferred Arc Weld Surfacing Process reconsideration fatigue crack initiation and fatigue crack growth mechanism at high temperature.

  • PDF

Development of Micro Press for Forming the Micro Thin Foil Valve (마이크로 박판 밸브 성형을 위한 마이크로 프레스 개발)

  • Lee, Hye-Jin;Lee, Nak-Kyu;Lee, Hyoung-Wook
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.5
    • /
    • pp.166-171
    • /
    • 2007
  • In this paper Research development about a micro metal forming manufacturing system has been developed. A micro forming system has been achieved in Japan and it's developed micro press is limited to single forming process. To coincide with the purpose to be more practical, research and development is necessary about the press which the multi forming process is possible. We set the development of the equipment including micro deep drawing, micro punching and micro restriking process to the goal. To achieve this goal, we set the application product to a micro thin foil valve which is used in the micro pump module. The compound die set has been designed and manufactured to make two step process. The material of thin foil valve is SUS-304 and its thickness is 50$\mu$m. We can get a good forming results from micro punching experiments in this paper.

LBCC of Transient State for High Strength Steel in Hot Strip Mills (열연 고강도강의 비정상부 온도제어를 위한 LBCC 개발)

  • Park, Cheol-Jae;Yoon, Kang-Sup
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.4
    • /
    • pp.382-387
    • /
    • 2011
  • In this paper, a LBCC (Latter Bank Cooling Control) for the high strength steel is proposed to obtain the desirable temperature and the property of the material along the longitudinal direction of the steel on the ROT (Run-Out Table) process. A cooling valve is modeled to analyze the response of the ROT banks. The control concept is derived from a field data, a valve model considering the valve response and a TTT (Time-Temperature Transformation) diagram. The proposed control is verified from the simulation results under the various carbon quantities. It is shown through the field test of the hot strip mill that the deviation of the CT (Coiling Temperature) is considerably decreased by the proposed temperature control.

The Second Animal Tests of Artificial Heart Valves (인공심장판막의 개발과 동물실험 -인공심장판막의 2차 동물실험-)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • v.23 no.4
    • /
    • pp.617-621
    • /
    • 1990
  • A heart supplies blood of about 15, 000 liters to each human organ in a day. A normal function of heart valves is necessary to accomplish these enormous work of heart. The disease of heart valve develops to a narrowness of a closure, resulting in an abnormal circulation of blood. In an attempt to eliminate the affliction of heart valves, the operative method to replace with artificial heart valves has developed and saved numerous patients over past 30 years. This replacement operation has been performed since early 1960`s in Korea, but all the artificial heart valves used are imported from abroad with very high costs until recent years. New artificial heart valves have been developed in Korea Advanced Institute of Science and Technology since early 1980`s. The first developed valve was designed with a free-floating pyrolytic carbon disk that is suspended in a titanium cage. The design of the valve was tested in vitro, and in animals in 1987. The results from this study was that the eccentrically placed struts creates a major and minor orifice when the disc opens and stagnation of flow in the area of the minor orifice has led to valve thrombosis. In this work, the design of the valve was changed from a single - leaflet valve to double - leaflet one in order to resolve the problems observed in the first - year tests. Morphological and hemodynamic studies were made for the newly designed valves through the in vitro and in vivo tests. The design and partial materials of the artificial heart valve was improved comparing with first - year`s model. The disc in the valve was modified from single - leaflet to bi - leaflet, and the material of the cage was changed from titanium metal to silicon - alloyed pyrolytic carbon. A test was made for the valve in order to examine its mechanical performance and stability. Morphological and hemodynamic studies were made for the valve that had been implanted in tricuspid position of mongrel dogs. All the test animals were observed just before the deaths. A new artificial heart valve was designed and fabricated in order to resolve the problems observed in the old model. The new valve was verified to have good stability and high resistance to wear through the performance tests. The hemodynamic properties of the valve after implantation were also estimated to be good in animal tests. Therefore, the results suggest that the newly designed valve in this work has a good quality in view of the biocompatibility. However, valve thrombosis on valve leaflets and annulus were found. This morphological findings were in accordance with results of surface polishing status studies, indicating that a technique of fine polishing of the surface is necessary to develop a valve with higher quality and performance.

  • PDF

Sealing design optimization of nuclear pressure relief valves based on the polynomial chaos expansion surrogate model

  • Chaoyong Zong;Maolin Shi;Qingye Li;Tianhang Xue;Xueguan Song;Xiaofeng Li;Dianjing Chen
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1382-1399
    • /
    • 2023
  • Pressure relief valve (PRV) is one of the important control valves used in nuclear power plants, and its sealing performance is crucial to ensure the safety and function of the entire pressure system. For the sealing performance improving purpose, an explicit function that accounts for all design parameters and can accurately describe the relationship between the multi-design parameters and the seal performance is essential, which is also the challenge of the valve seal design and/or optimization work. On this basis, a surrogate model-based design optimization is carried out in this paper. To obtain the basic data required by the surrogate model, both the Finite Element Model (FEM) and the Computational Fluid Dynamics (CFD) based numerical models were successively established, and thereby both the contact stresses of valve static sealing and dynamic impact (between valve disk and nozzle) could be predicted. With these basic data, the polynomial chaos expansion (PCE) surrogate model which can not only be used for inputs-outputs relationship construction, but also produce the sensitivity of different design parameters were developed. Based on the PCE surrogate model, a new design scheme was obtained after optimization, in which the valve sealing stress is increased by 24.42% while keeping the maximum impact stress lower than 90% of the material allowable stress. The result confirms the ability and feasibility of the method proposed in this paper, and should also be suitable for performance design optimizations of control valves with similar structures.

Mitral Valve Replacement with Chordal Preservation in Mitral Stenotic Disease (승모판막 협착 질환에서 건삭보존 치환술에 대한 연구)

  • 김태호;김공수;구자홍
    • Journal of Chest Surgery
    • /
    • v.32 no.1
    • /
    • pp.10-15
    • /
    • 1999
  • Background: Mitral valve replacement with chordal preservation in patients with mitral regurgitation has been proved to be beneficial for left ventricular function and for reduction of postoperative complication. However, in patients with mitral stenosis, the effectiveness of the technique is controversial. It is not easy to insert prosthetic valve without left ventricular outflow tract obstruction and prosthetic valve leaflet motion hinderance. Material and Method : Five patients with mitral stenosis and seven patients with mitral stenoinsufficiency underwent mitral valve replacement with preservation of mitral subvalvular apparatus. Thickened and calcified leaflets are made thin by peeling off the thickened and calcified part. Commissurotomy was done and anterior leaflet was incised 2 mm apart from the annulus and then divided into two segments. Anterolateral and posteromedial segments including strut chordae, were reattached to mitral commissural area, respectively. Result: There was no evidence of prosthetic valve dysfunction, paravalvular leakage, left ventricular outflow tract obstruction, complications and operative or late deaths. Conclusion: We conclude that mitral vlave replacement with chordal preservation was safe and effective technique for the patients with mitral stenotic disease.

  • PDF

A Study on the Strength Safety of a Gas Valve (가스밸브의 강도안전성에 관한 연구)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.1
    • /
    • pp.60-63
    • /
    • 2018
  • This paper presents the FEM analysis results on the strength safety of a gas valve for a LPG cylinder. Based on the FEM analysis, the maximum von Mises stress on the boundary zone between a safety valve and the upper area of the thread is 99.2 MPa for the supplied gas pressure of 3.5 MPa in which the gas valve is fully opened. The maximum von Mises stress of 99.2 MPa is considered as safety value, because that value is lower than the yield stress of a brass material. In this case, the maximum deformation at the upper right part of the pressure regulator is 0.002mm. The maximum deformation zone is not a meaning part of the sealing part such as an O-ring or a diaphragm of a gas valve and a pressure regulator. The proposed hybrid gas valve model in which is integrated with a conventional cut-off valve and a pressure regulator is recommended as a gas leakage free mechanism and minimized compact size for a LPG cylinder.