• Title/Summary/Keyword: Valve Design

Search Result 1,165, Processing Time 0.027 seconds

Modeling and analysis of selected organization for economic cooperation and development PKL-3 station blackout experiments using TRACE

  • Mukin, Roman;Clifford, Ivor;Zerkak, Omar;Ferroukhi, Hakim
    • Nuclear Engineering and Technology
    • /
    • v.50 no.3
    • /
    • pp.356-367
    • /
    • 2018
  • A series of tests dedicated to station blackout (SBO) accident scenarios have been recently performed at the $Prim{\ddot{a}}rkreislauf-Versuchsanlage$ (primary coolant loop test facility; PKL) facility in the framework of the OECD/NEA PKL-3 project. These investigations address current safety issues related to beyond design basis accident transients with significant core heat up. This work presents a detailed analysis using the best estimate thermal-hydraulic code TRACE (v5.0 Patch4) of different SBO scenarios conducted at the PKL facility; failures of high- and low-pressure safety injection systems together with steam generator (SG) feedwater supply are considered, thus calling for adequate accident management actions and timely implementation of alternative emergency cooling procedures to prevent core meltdown. The presented analysis evaluates the capability of the applied TRACE model of the PKL facility to correctly capture the sequences of events in the different SBO scenarios, namely the SBO tests H2.1, H2.2 run 1 and H2.2 run 2, including symmetric or asymmetric secondary side depressurization, primary side depressurization, accumulator (ACC) injection in the cold legs and secondary side feeding with mobile pump and/or primary side emergency core coolant injection from the fuel pool cooling pump. This study is focused specifically on the prediction of the core exit temperature, which drives the execution of the most relevant accident management actions. This work presents, in particular, the key improvements made to the TRACE model that helped to improve the code predictions, including the modeling of dynamical heat losses, the nodalization of SGs' heat exchanger tubes and the ACCs. Another relevant aspect of this work is to evaluate how well the model simulations of the three different scenarios qualitatively and quantitatively capture the trends and results exhibited by the actual experiments. For instance, how the number of SGs considered for secondary side depressurization affects the heat transfer from primary side; how the discharge capacity of the pressurizer relief valve affects the dynamics of the transient; how ACC initial pressure and nitrogen release affect the grace time between ACC injection and subsequent core heat up; and how well the alternative feeding modes of the secondary and/or primary side with mobile injection pumps affect core quenching and ensure stable long-term core cooling under controlled boiling conditions.

A Study on Measures to Achieve Performance and Safety of Air Respirators for Fire Fighters (소방대원용 공기호흡기의 성능안전확보 대책에 관한 연구)

  • Son, Bong-Sei;Oh, Suk-Hwan;Kim, Yeop-Rae
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.77-81
    • /
    • 2012
  • This study of aims to provide basic data for improve the performance of air respirators that generate by bad influencing elements in fire emergency field. With three types of conditions set up for these tests, the pressures of containers have been extracted; the ambient temperatures have been checked, and the generation of moisture inside and outside container have been checked and identified. Specifically, these tests have been conducted at temperatures ranging between $-20{\sim}40^{\circ}C$. The pressures of containers have been extracted to reach between 0.4~0.8 MPa, using a pressure regulating valve. These tests have resulted in no change in the temperature and moisture outside the containers and no generation of moisture inside the containers as well. Although moisture has been generated inside the pressure gauge, the amount of moisture has not exceeded 25 $mg/m^3$, i.e. the limit suggested by the Korean Government. Therefore, it is judged that the moisture generated inside air respirators, which can be the most critical issue in the equipment, is likely to be caused in the process of managing the equipment or replacing air in the equipment at places of end-users, rather than in the process of manufacturing and production of the equipment.

Analysis of pneumatic braking component effects and characteristics of a diesel electric locomotive (디젤전기기관차의 공압제동 영향인자 및 특성 분석)

  • Choi, Don Bum;Kim, Min-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.541-549
    • /
    • 2018
  • This paper deals with the braking dynamic behavior of diesel electric locomotive pulling domestic cargo and passenger vehicles. Friction coefficient, pneumatic pressure, and running resistance affecting the braking system were tested. For the friction coefficient, the Dynamo test was performed with reference to UIC 541-4. The results are analyzed by multivariate regression and the relationship between braking force and ititial velocity is presented. The pneumatic pressure were classified into service braking and emergency braking. In order to reflect the characteristics of the brake valve and piping, the pressure rising over time was measured in the vehicle. In order to reflect the external force acting on the vehicle, we carried out the test of EN 14067-4 and presented the second order polynomial formula on a running resistance. The running resistance test results were compared with other countries. The dynamic behavior of a diesel electric locomotive running on a straight flat track based on vehicle resources, friction coefficient, braking pressure, and running resistance is simulated using the time integration presented in EN 14531-1. The simulation results were compared and verified with the vehicle braking test results. The results of this study can be used to analyze the dynamic braking behavior of a train. Also, it is expected that various parameters affecting braking in vehicle design can be analyzed and used as basic data for braking performance improvement.

Modeling and Simulation for Predicting the Impact of Hydraulic Breaker (유압 브레이커의 충격량 예측을 위한 모델링과 해석)

  • Kim, Sung-Hyun;Chung, Jaeho;Baek, Dong-Cheon;Park, Jong-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.741-749
    • /
    • 2019
  • A hydraulic breaker attached to an excavator is a kind of constructuion equipment which is used for the disassembling of buildings, crashing road pavement, breaking rocks at quarry and etc. Therefore, the performance of the hydraulic breaker is mainly evaluated by the impact quantity and impact efficiency, which is an important factor for both the manufacturer and the user. In this paper, modeling and simulation for the prediction of the impact of the hydraulic breaker was conducted according to hydraulic pressure area and operating conditions of the hydraulic valve and piston using the commercial tools SimulationX for the 20ton hydraulic breaker which is mainly used in construction site. In order to verify the reliability of modeling and simulation, the results of previous experimental studies were compared and verified. The results of this study are expected to be useful for predicting the impact of the hydraulic breaker at the design stage before manufacturing and for studying parameters for improving the impact quantity. In addition, the manufacturer predicts that the development time and cost will be reduced through trial and error prevention by predicting the impact of the hydraulic breaker through the results of this paper.

A Case Study on the Risk Analysis for the Installation of Measurement Error Verification Facility in Hydrogen Refueling Station (수소 충전소 계량오차 검증 설비 설치를 위한 위험성 분석 사례 연구)

  • Hwayoung, Lee;Hyeonwoo, Jang;Minkyung, Lee;Jeonghwan, Kim;Jaehun, Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.30-36
    • /
    • 2022
  • In commercial transactions of energy sources using hydrogen charging stations, high-accuracy flow meters are needed to prevent accidents such as overcharging due to inaccurate measurements and to ensure transparency in hydrogen commercial transactions through accurate measurements. This research developed a Corioli-type flowmeter prototype and conducted a risk assessment to prevent accidents during a process change comparison experiment for existing charging stations to verify the measurement performance. A process change section was defined for the installation of measurement facilities for empirical experiments and HAZOP was conducted. In addition, JSA was also conducted to secure the safety of experimenters, such as preventing valve mis-opening during empirical experiments. Measures were established to improve the risk factors derived through HAZOP, and work procedures were established to minimize human errors and ensure the safety of workers through JSA. The design change and system manufacturing for the installation of the metering system were completed by reflecting the risk assessment results, and safety could be confirmed through the performance comparison test of the developed meter prototype. The developed prototype flow meter showed a total of 30 flow measurements under the operating conditions of 70 MPa, and the average error was -1.58% to 3.96%. Such a metering error was analyzed to have the same performance as a flow meter installed and operated for commercial use.