• Title/Summary/Keyword: Value-based healthcare

Search Result 180, Processing Time 0.023 seconds

The Applicability of the United States' Chronic Disease Self-Management Program (CDSMP) to Korean Adults (미국 만성질환자가관리프로그램(CDSMP)의 성공 사례와 국내 적용가능성)

  • Ahn, SangNam;Kim, Keon Yeop;Ory, Marcia G.;Na, Yoon Joo;Kim, Ki Su
    • Korean Journal of Health Education and Promotion
    • /
    • v.31 no.4
    • /
    • pp.63-72
    • /
    • 2014
  • Objectives: The current study reviews the implementation and evaluation of the Chronic Disease Self-Management Program (CDSMP) in the United States (U.S.) to illustrate the program's potential contribution to improving health among Korean adults with chronic conditions while saving healthcare costs. Methods: This study examines existing literature on the history, theoretical background, essential elements, and delivery outcomes of CDSMP with special focus on the successes and challenges to be faced in the implementation of CDSMP to Koreans with chronic conditions. Results: CDSMP is designed to empower people with chronic conditions to develop skills necessary for medical, social role, and emotional management of chronic conditions. Recent studies show the utility of CDSMP in achieving the Triple Aim health reform goals (i.e., better care, better health, better value). Lessons learned from the U.S. experience emphasize the importance of establishing evidence-based studies, collaborating with community partners, and diversifying funding sources to make CDSMP more sustainable. Conclusion: The current study demonstrates the replicability of CDSMP and potential for expansion in Korea. More concerted efforts among academia, government, and communities are needed to deliver CDSMP to Korean adults and identify its effectiveness within the Korean context in terms of meeting the Triple Aim goals of better care, better health, and better value.

Knowledge Management of Hospital Clinical Support Department - A Case Study of a Laboratory in S Hospital's Eye Center - (병원 진료지원부서의 역량강화를 위한 지식경영 : S병원 안센터검사실 사례연구)

  • Rhee, Shang-Ro;Kim, Kwang-Jum;Lee, Hyun-Ju
    • Korea Journal of Hospital Management
    • /
    • v.18 no.4
    • /
    • pp.113-130
    • /
    • 2013
  • The aim of this article is to propose a framework for standardization of knowledge based on a case study of clinical operation to guide initial hospital knowledge management projects. Both quantitative and qualitative data for the project from 2009 through 2012 were collected for analysis. In a study of knowledge management project of a lab in S Hospital's Eye Center, this research examines the standardization of operational knowledge for competence enhancement of the lab. The lab defined and standardized the knowledge concern of the lab operation and the in-group from 2008. Organizations are often unaware of the potential value of tacit knowledge in both clinical and administrative area. The main finding from the case study is that analysis of such tacit knowledge of a lab in a hospital can be transformed into explicit knowledge for organizational capabilities such as improved quality, responsiveness and competitive advantage. Concepts from Nonaka's theory are used to investigate processes of knowledge standardization, examining the strategic value of tacit knowledge and the need to rely primarily on internal documentation processes. Since there has been limited research on hospital knowledge management. it may also be useful to researchers in generating propositions for further study.

  • PDF

Development of Real-Time Arrhythmia Detection and BLE-based Data Communication Algorithm for Wearable Devices (웨어러블 디바이스를 위한 실시간 부정맥 검출 및 BLE기반 데이터 통신 알고리즘 개발과 적용)

  • SooHoon, Maeng;Daegwan, Kim;Hyunseok, Lee;Hyojeong, Moon
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.399-408
    • /
    • 2022
  • Because arrhythmia occurs irregularly, it should be examined for at least 24 hours for accurate diagnosis. For this reason, this paper developed firmware software for arrhythmia detection and prevented consumption of temporal and human resources and enabled continuous management and early diagnosis. Prior to the experiment, the interval between the R peaks of the QRS Complex was calculated using the Pan-Tompkins algorithm. The developed firmware software designed and implemented an algorithm to detect arrhythmia such as tachycardia, bradycardia, ventricular tachycardia, persistent tachycardia, and non-persistent tachycardia, and a data transmission format to monitor the collected data based on BLE. As a result of the experiment, arrhythmia was found in real time according to the change in BPM as designed in this paper. And the data quality for BLE communication was verified by comparing the sensor's serial communication value with the Android application reception value. In the future, wearable devices for real-time arrhythmia detection will be lightweight and developed firmware software will be applied.

A Study on the Utilization of Wellness IT Service in Nursing Care Center for the Elderly (노인요양시설의 웰니스 IT서비스 활용에 관한 연구)

  • Park, Youngsuk;Jeen, Sungkwang;Kim, Seog;Choi, Jeongil
    • Journal of Information Technology Services
    • /
    • v.19 no.5
    • /
    • pp.93-106
    • /
    • 2020
  • This study attempts to present specific technical measures and case models to meet the needs of caregivers and maximize the effectiveness of senior care facilities by utilizing Wellness IT Service. IT services for supporting elderly care need to go beyond productivity and efficiency and now require the new choice and standards to satisfy the Wellness concept of well-being and happiness. Therefore, this study explores to develop the existing human-based service into the Wellness IT Service by utilizing IT based Wellness in the elderly care facility and thereby to improve the quality of elderly care service. Therefore, this study analyzes the relevant research background and the various feasibility of technical applications of Wellness IT service, and review the new value creation in the elderly care facilities. Lastly this study provides a new foundation for Wellness architecture and a service model for using Wellness IT infrastructure of the elderly care facilities.

A Hearing Compensation System Based on Hearing Test and Fitting Profiles (청력검사와 적합 프로파일 기반의 청력 보정 시스템)

  • Kim, HyoungWook;Lee, YeongRok;Park, DongGyu;Han, ChangYoung
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.9
    • /
    • pp.1110-1118
    • /
    • 2018
  • Personal sound amplifiers(PSAPs) provide accessible and affordable healthcare to individuals with hearing disability. Many studies are in progress for affordable PSAP development, but still people do not have a best fitting profile for the PSAP depending on their hearing test. As a result, they do not have a personalized and profiled music and sound, which are very helpful for those who has hearing problems. In this paper, we propose a device and mobile system to provide music with an equalizer value according to the hearing condition of an individual to prevent the hearing loss. In order to overcome the limit of frequency band of the equalizer in a smart phone, we developed bluetooth controlled equalizer based on the fitting profiles.

Usefulness of Estimated Height Loss for Detection of Osteoporosis in Women

  • Yeoum, Soon-Gyo;Lee, Jong-Hwa
    • Journal of Korean Academy of Nursing
    • /
    • v.41 no.6
    • /
    • pp.758-767
    • /
    • 2011
  • Purpose: This study was done to examine the threshold value of estimated height loss at which the risk of osteoporosis increases and to verify its discriminative ability in the detection of osteoporosis. Methods: It was conducted based on epidemiological descriptive methods on 732 Korean women at a public healthcare center in Seoul between July and November 2010. ANOVA, Pearson correlation, logistic regression analysis and receiver operating characteristics (ROC) curve were used for data analysis. Results: There was an age-related correlation between bone mineral density (lumbar spine: F=37.88, p<.001; femur: F=54.27, p<.001) and estimated height loss (F=27.68, p<.001). Estimated height loss increased significantly with decreasing bone mineral density (lumbar spine: r=-.23, p<.001; femur: r=-.34, p<.001). The odds ratio for the point at which the estimated height loss affects the occurrence of osteoporosis was found to increase at a cut-off value of 2 cm and the area under ROC curve was .71 and .82 in lumbar spine and femur, respectively. Conclusion: The optimal cut-off value of the estimated height loss for detection of osteoporosis was 2 cm. Height loss is therefore a useful indicator for the self-assessment and prognosis of osteoporosis.

A study on the Healing Effects of UV-Day light for the healthy Leprosy Center through the ANOVA statistical analysis - Focused on 5S (Sort, Straighten, Shine, Standardize, Sustain)

  • Shaikh, Javaria Manzoor;Park, JaeSeung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.19 no.4
    • /
    • pp.7-18
    • /
    • 2013
  • Purpose: The aim of this paper is to reduce the stress and the disturbance occur in selective action of patient. This article will also help us to control spreading and reduce the order and bacteria produced by leprosy disease among the lepers. This will be achieved with the help of several variables and these variables help us on health benefits is 5S (Sort, Straighten, Shine, Standardize, Sustain) i.e. ratio of sectional morphology, lessor 90 degree angles, day light, universal design building and maximum ventilation. The replies from the questionnaire were collected based on varying levels of satisfaction and gloominess on the scale of 1-10. Methods: The multi-layer methodological framework for maximising the healing environment obtained from the observation of schemes and parameters of ANOVA: (Analysis Of Variance between five deciding factors) are. Firstly applied for the calculation of the patient's satisfaction for U.V light from sun on ECOTECT simulation, secondly the number of $90^{\circ}$ angle, along the corridors. Thirdly understanding the ways to represent people's perceptual structures and way finding with Space Syntax software. Fourthly the ratio of depth to height of the building typology and finally interviewing the subjects describing their special experiences based on scale value. The focus of this testing of human subjects was to receive data for the existence of image scheme in way-finding and to identify the mechanisms by which sun light impacts human (lepers) health. Results: AMPVA studies concluded that there is similarity between I and O plan as well as L and H plan whereas U plan was difference among the five selected architectural shapes. Implications: The purpose of this research is to show the effects of the I-type, L-type, C-type, U-type and O-type plan design, and to analyse the morphology for EBD (Evidence-Based Design) healing environment which is a universal design for Munghopir Karachi, in Pakistan.

A Design of Authentication Method for Secure Communication based on Wearable Device (웨어러블 디바이스 기반의 안전한 통신을 위한 인증기법 설계)

  • Park, Jung-Oh
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.4
    • /
    • pp.41-46
    • /
    • 2016
  • Recently, many domestic and foreign corporates are concentrating in investment to wearable devices and users are provided with various service based on wearable devices 26% more than compared to last year. It is widely used in previous healthcare, smart work, smart home environment, and it is now introduced to get connection to fused service environment. However, as products of G company are commercialized, the security issue of personal information is causing dispute in society, and the danger of data management and security regarding telecommunication is increasing. Also, because the password system used in previous wireless environment is still in use, there are possible vulnerability considering the new and mutant security threat. This thesis conducted study about protocols that can exercise safe telecommunication in the basis of wearable devices. In the registration and certification process, the signature value is created based on the code value. The telecommunication method is designed to conduct safe telecommunication based on the signature value. As for the attack method occurring in the wearable device environment, the safety was analyzed and conducted performance evaluation of previous password system and proposal system, and verified about 14% of efficiency.

Performance Evaluation of Reconstruction Algorithms for DMIDR (DMIDR 장치의 재구성 알고리즘 별 성능 평가)

  • Kwak, In-Suk;Lee, Hyuk;Moon, Seung-Cheol
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.29-37
    • /
    • 2019
  • Purpose DMIDR(Discovery Molecular Imaging Digital Ready, General Electric Healthcare, USA) is a PET/CT scanner designed to allow application of PSF(Point Spread Function), TOF(Time of Flight) and Q.Clear algorithm. Especially, Q.Clear is a reconstruction algorithm which can overcome the limitation of OSEM(Ordered Subset Expectation Maximization) and reduce the image noise based on voxel unit. The aim of this paper is to evaluate the performance of reconstruction algorithms and optimize the algorithm combination to improve the accurate SUV(Standardized Uptake Value) measurement and lesion detectability. Materials and Methods PET phantom was filled with $^{18}F-FDG$ radioactivity concentration ratio of hot to background was in a ratio of 2:1, 4:1 and 8:1. Scan was performed using the NEMA protocols. Scan data was reconstructed using combination of (1)VPFX(VUE point FX(TOF)), (2)VPHD-S(VUE Point HD+PSF), (3)VPFX-S (TOF+PSF), (4)QCHD-S-400((VUE Point HD+Q.Clear(${\beta}-strength$ 400)+PSF), (5)QCFX-S-400(TOF +Q.Clear(${\beta}-strength$ 400)+PSF), (6)QCHD-S-50(VUE Point HD+Q.Clear(${\beta}-strength$ 50)+PSF) and (7)QCFX-S-50(TOF+Q.Clear(${\beta}-strength$ 50)+PSF). CR(Contrast Recovery) and BV(Background Variability) were compared. Also, SNR(Signal to Noise Ratio) and RC(Recovery Coefficient) of counts and SUV were compared respectively. Results VPFX-S showed the highest CR value in sphere size of 10 and 13 mm, and QCFX-S-50 showed the highest value in spheres greater than 17 mm. In comparison of BV and SNR, QCFX-S-400 and QCHD-S-400 showed good results. The results of SUV measurement were proportional to the H/B ratio. RC for SUV is in inverse proportion to the H/B ratio and QCFX-S-50 showed highest value. In addition, reconstruction algorithm of Q.Clear using 400 of ${\beta}-strength$ showed lower value. Conclusion When higher ${\beta}-strength$ was applied Q.Clear showed better image quality by reducing the noise. On the contrary, lower ${\beta}-strength$ was applied Q.Clear showed that sharpness increase and PVE(Partial Volume Effect) decrease, so it is possible to measure SUV based on high RC comparing to conventional reconstruction conditions. An appropriate choice of these reconstruction algorithm can improve the accuracy and lesion detectability. In this reason, it is necessary to optimize the algorithm parameter according to the purpose.

The Effectiveness of Blood β-ketone Testing in Patients with Diabetic Ketosis: A Systematic Review & Meta-analysis (당뇨환자에서 자가관리형 베타케톤검사의 유효성: 체계적 문헌 고찰 및 메타분석)

  • Mo, Jin A;Jang, Sunyoung;Bang, Hee Young
    • Korean Journal of Health Education and Promotion
    • /
    • v.31 no.4
    • /
    • pp.1-10
    • /
    • 2014
  • Objectives: The effectiveness of Blood ${\beta}$-ketone testing by using self-monitoring strip on diabetic patients. Methods: Clinical effectiveness of blood ${\beta}$-ketone testing was assessed through correlation with reference test that measured blood ${\beta}$-ketone value through gas chromatography or enzyme method, diagnostic accuracy, time taken for the test and time taken for confirmative diagnosis of diabetic ketosis by selecting literatures on researches that conducted this test on ketosis(suspected) patients or diabetic ketosis(suspected) patients. Each of the stages from literature search to application of selection standards and extraction of data were carried out independently by the Subcommittee along with 2 researchers. Results: 7 reports were selected. ${\beta}$-ketone testing displayed high level of correlation in the range of r=0.92~0.99 with test using enzyme method as the reference standard. Regarding the diagnostic accuracy, sensitivity of 0.82, specificity of 0.74. The time taken for the test was 30seconds for the index test, which is shorter than reference standard test. Conclusion: Blood ${\beta}$-ketone testing was assessed to be a safe and effective test to monitor ketosis and assess the level of risk of ketosis by measuring the blood ${\beta}$-ketone on ketosis patients and diabetic ketosis patients since it has high level of correlation with reference test and short period of testing.