• Title/Summary/Keyword: Value Measurement

Search Result 4,755, Processing Time 0.032 seconds

Luminance Correction Algorithm Based on Measuring Angle for the Portable Luminance Measurement System (휴대용 휘도측정시스템의 측정각도기반 휘도보정알고리즘)

  • Sun, Eun-Hey;Kim, Dongyeon;Kim, Yong-Tae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.4
    • /
    • pp.321-326
    • /
    • 2016
  • In this paper, we propose a luminance correction algorithm based on measuring position for potable luminance measurement system. Measurement position and angle have an affect on the luminance value. We improve the position-based luminance measurement system using luminance correction algorithm based on the measuring angle. We analyze change of luminance value according to the measurement distance and angle from camera and light source. The certified point-luminance meter is used to evaluate a scene luminance measuring method using the image information of camera. Also, we derive an expression equation for evaluating luminance value from determined position. The performances of the proposed system are verified by using comparative experiments with the point-luminance meter using experimental signboard.

A Study on Measurement and Automation Method of Cylinder Head Swirl (실린더 헤드 스월 측정 및 자동화 방법에 관한 연구)

  • Lee Choong-Hoon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.1
    • /
    • pp.92-99
    • /
    • 2006
  • The swirl ratio of a charge in the cylinder was estimated by calculating the ratio of the rotary speed of charge which could be simulated from the rotary speed of paddle in the swirl measurement apparatus, to the engine speed which could be calculated by measuring intake air flow rate. The automation of the swirl ratio measurement for cylinder head was achieved by controling both valve lift in cylinder head and a suction pressure of surge tank using two step-motors. The number of measurement position for calculating mean swirl ratio was varied by adjusting the interval of valve lift. The mean swirl ratio with varying the number of measurement position showed nearly constant value. Two measurement methods for measuring the swirl ratio were compared, one was to control the suction pressure of the surge tank with PID (proportional, integral, differential) mode with by-pass valve controlled by the step motor and the other did not control the surge tank pressure by fixing the by-pass valve. The difference of the mean swirl ratio between the two measurement methods showed nearly constant value with varying the number of measurement position. This means that the w/o PID control method could be preferred to the PID control method which has been used, due to the simpleness of the swirl measurement.

A Study on the Risk Assessment by Comparing Workplace Environment Measurement with Exposure Assessment Program(ECETOC TRA) (작업환경측정과 노출평가 프로그램(ECETOC TRA) 비교에 따른 위해성 평가에 관한 연구)

  • Ko, Won-Kyoung;Yi, Young-Seop
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.3
    • /
    • pp.1-6
    • /
    • 2013
  • This study was conducted to compare the value of the working environment measurement with the expected exposure value drawn by using a program, thereby going to investigate whether it is available to the risk assessment of domestic workplace. We used the ECETOC TRA program which is one of the exposure predictive models. Four kinds of substances were measured in two workplace which was exposed to organic solvents and one kind of substance was measured in three workplace which was exposed to dusts and then an exposure assessment of chemical risk factors was conducted. The result value of the working environment measurement, solid substance exceeded standard in one site, and it was found that the other solid and liquid substances were within the standard. The value of the exposure assessment program showd the same result; it was higher than the value of the working environment measurement, suggesting that due to its nature, the exposure assessment program is run only on the worst situation. Therefore, it was found that when the exposure assesment program is used, variables should be substituted only after accurately assessing the workplace and it is a good idea to assess the risk beforehand with the exposure assessment program in the case of the workplace which employs no more than 5 people and where it is hard to assess the working environment.

An Analysis of Elementary Students' Selection of Representable Value and Confident Method That Appear in Measuring Activities (측정과 관련된 실험 활동에서 보이는 초등학생의 대푯값 선정 및 신뢰 방법 분석)

  • Yang, Il-Ho;Lim, Sung-Man;Lim, Jae-Keun;Song, Jin-Lyoung
    • Journal of Korean Elementary Science Education
    • /
    • v.28 no.3
    • /
    • pp.263-276
    • /
    • 2009
  • The purpose of this study was to analyze the elementary students' selection of representable value and confident method that appear in measuring activities by using a microgenetic method. The participants were seven elementary students in the fourth grade. They performed the same measuring activities six times for the study period. Data were collected by interview and observation with their activity recording papers and video tape transcription. Their activities were recorded and documented for the analysis. Results were as follows. First, in the time measuring activity, elementary students developed desirably as their measuring experience increased, for example they selected a representable value in use of a repeated measurement and used a various method in the domain of a time measurement and they showed an increase of a quantitative observation in the volume domain except in the length domain. Second, in a confident method of a representable value, though they must rely upon a repeated measurement, they only measure repeatedly in the time domain. Also in the time domain, it doesn't get accomplished a exact confidence of a representable value at a shortage of skill about a measurement. Accordingly this study will be implications for teachers to teach a handling abilities of measuring instruments to elementary students and to be promote understanding a nature of measurement.

  • PDF

A Measurement Allocation for Reliable Data Gathering in Spatially Corrected Sensor Networks (공간상관 센서네트워크에서 신뢰성 있는 데이터 수집을 위한 측정의 분배)

  • Byun, Sang-Seon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.434-437
    • /
    • 2016
  • In this paper, we consider a measurement allocation problem for gathering reliable data from a spatially correlated sensor field. We allocate the probability of each sensor's being measured considering its marginal contribution in entire data gathering; higher measurement probability is given to a sensor that gives higher reilable data. First we establish a correlation model considering limit in each sensor's transmission power, noise in the process of measurement and transmission, and attenutations in wireless channel. Then we evaluate the reliability of gathered data by estimating distortion error in sink node. We model the measurement allocation problem in spatially correlated sensor field into a cooperative game, and quantifiy each sensor's marginal contribution using Shapley Value. Then, the probability of each sensor's being measured is given in proportion to the Shapley Value.

  • PDF

Standards for Ground Settlement Management when Reinforcing Ground in the Abandoned Mine (폐광지역 지반공사시 지반침하 관리를 위한 기준)

  • Yang, In Jae;Lee, Seung Ah;Baik, Dong Ho
    • Tunnel and Underground Space
    • /
    • v.27 no.5
    • /
    • pp.295-302
    • /
    • 2017
  • In this study, a new quantitative instrumentation and measurement standards applicable to the field of mining has been proposed to improve the problems of the current measurement practices that apply the measuring standards of the civil engineering field (road, railway, etc.). With the data coordination of the mine reclamation corporation, we collected data on ground subsidence in the abandoned mine area, and studied various techniques for establishing a new management reference value based on the manual measurement data measured in the field. As a result, new instrumentation and measurement standards is set up and proposed by using statistics like the average value, the third quartile, the 95% confidence, and the maximum value.

A study on roundness measurement errors according to measurement conditions (측정조건에 따른 진원도 측정오차에 대한 연구)

  • Jung, Hyun-Suk;Hong, Cheong-Min;Choi, Ji-Sun
    • Design & Manufacturing
    • /
    • v.13 no.4
    • /
    • pp.51-56
    • /
    • 2019
  • Due to industrial development, the importance of GD&T tolerance is growing day by day. Roundness measurement means the size deviated from the ideal circle. Roundness evaluation methods include LSCI, MZCI, MCCI, and MICI. Generally, A is used a lot at industrial evaluation. In this experiment, we studied the variations in table velocity, filter values, and detector angles, which can cause errors in roundness measurements. The measurement conditions were table speeds of 10, 30 and 60 mm/s, probe angles of 10, 20 and 30 degrees and frequency filter settings of 15, 150 and 500 upr and The number of experiments was measured 30 and the average value was chosen as a representative value. The hypothesis test showed that the p-value for the frequency filter was greater than 0.05, and the experiment rejected the null hypothesis and adopted the alternative hypothesis.

The application of a nondestructive method to measure the acidity of Korean papers (한지의 산성도 측정을 위한 비파괴적 방법의 적용)

  • Lee, Hye-Yun;Chung, Yong-Jae;Lee, Kyu-Sik;Han, Sung-Hee
    • 보존과학연구
    • /
    • s.20
    • /
    • pp.21-47
    • /
    • 1999
  • According to damage of papers by the chemical cause, papers become to acidify. Among the 3 kinds of method measuring the acidity of paper, one was nondestructive method measuring the surface of the paper by flat type electrode and the others were destructive methods measuring directly by cold water extract method and hot water extract method. In case of the cellulolytic cultural properties, the latter methods were not applied because those methods must bedissociated papers. To measure the paper acidity nondestructively, we investigated the correlation of the nondestructive method and the destructive methods. The conclusions are as follows. 1) In the relationship of the cold water extract method and the hot water extract method, It was indicated that the pH measured by the hot water extract method was high quality printing paper 0.08, rough printing paper 0.13, and Korean paper 0.29 higher than that by the cold water extract method.2) In the relationship of the cold water extract method and the surface measurement method, It showed that the pH value measured by the cold water extract method was high quality printing paper 1.86, rough printing paper 0.80,and Korean paper 0.58 higher than value that by the surface measurement.3) In the relationship of the hot water extract method and the surface measurement method, It showed that the pH value measured by the hot ABSTRACT water extract method was high quality printing paper 1.78, rough printing paper 0.66, and Korean paper 0.29 higher than that by the surface measurement. From the above-mentioned results, the pH value measured by the surface measurement was need to high about 1.78∼1.86 in high quality printing paper, 0.66-0.80 in rough printing paper, and 0.29∼0.58 in Korean paper and the surface measurement with flat type electrode was very available to measure the acidity of Korean papers actually.

  • PDF

On-site conservation of a gilt bronze crown (발굴현장 수습 유물 보존처리)

  • Yu, Jae-Eun
    • 보존과학연구
    • /
    • s.20
    • /
    • pp.49-64
    • /
    • 1999
  • According to damage of papers by the chemical cause, papers become to acidify. Among the 3 kinds of method measuring the acidity of paper, one was nondestructive method measuring the surface of the paper by flat type electrode and the others were destructive methods measuring directly by cold water extract method and hot water extract method. In case of the cellulolytic cultural properties, the latter methods were not applied because those methods must bedissociated papers. To measure the paper acidity nondestructively, we investigated the correlation of the nondestructive method and the destructive methods. The conclusions are as follows. 1) In the relationship of the cold water extract method and the hot water extract method, It was indicated that the pH measured by the hot water extract method was high quality printing paper 0.08, rough printing paper 0.13, and Korean paper 0.29 higher than that by the cold water extract method.2) In the relationship of the cold water extract method and the surface measurement method, It showed that the pH value measured by the cold water extract method was high quality printing paper 1.86, rough printing paper 0.80,and Korean paper 0.58 higher than value that by the surface measurement.3) In the relationship of the hot water extract method and the surface measurement method, It showed that the pH value measured by the hot ABSTRACT water extract method was high quality printing paper 1.78, rough printing paper 0.66, and Korean paper 0.29 higher than that by the surface measurement. From the above-mentioned results, the pH value measured by the surface measurement was need to high about 1.78∼1.86 in high quality printing paper, 0.66-0.80 in rough printing paper, and 0.29∼0.58 in Korean paper and the surface measurement with flat type electrode was very available to measure the acidity of Korean papers actually.

  • PDF

A Methodology of Radiation Measurement of MOSFET Dosimeter (MOSFET 검출기의 방사선 측정 기법)

  • Lho, Young-Hwan;Lee, Sang-Yong;Kang, Phil-Hyun
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.159-162
    • /
    • 2009
  • The necessity of radiation dosimeter with precise measurement of radiation dose is increased and required in the field of spacecraft, radiotheraphy hospital, atomic plant facility, etc. where radiation exists. Until now, a low power commercial metal-oxide semiconductor(MOS) transistor has been tested as a gamma radiation dosimeter. The measurement error between the actual value and the measurement one can occur since the MOSFET(MOS field-effect transistor) dosimeter, which is now being used, has two gates with same width. The measurement value of dosimeter depends on the variation of threshold voltage, which can be affected by the environment such as temperature. In this paper, a radiation dosimeter having a pair of MOSFET is designed in the same silicon substrate, in which each of the MOSFETs is operable in a bias mode and a test mode. It can measure the radiation dose by the difference between the threshold voltages regardless of the variation of temperature.

  • PDF