• Title/Summary/Keyword: Value Measurement

Search Result 4,755, Processing Time 0.038 seconds

Clinical Availability of Serum Procalcitonin in Children with Bacterical Infection (소아 세균감염증에서 혈청 procalcitonin의 임상적 유용성)

  • Noe, Eun-Jung;Lee, So-Yeon;Lee, Kyu-Man;Kim, Kwang-Nam
    • Pediatric Infection and Vaccine
    • /
    • v.17 no.2
    • /
    • pp.108-113
    • /
    • 2010
  • Purpose : The aim of this study was to identify clinical availability of serum procalcitonin (PCT) compared with C-reactive protein (CRP) in prediction of bacterial infection in children. Methods : A retrospective study was conducted with children who had been admitted to the Department of Pediatrics with bacterial and viral infection between April 2008 and March 2009 and children who were admitted with Juvenile rheumatoid arthritis (JRA) between August 2007 and July 2009. Serum PCT levels were measured using an enzyme-linked fluorescent assay. Results : The study population included 10 patients with bacterial infection (group I), 69 with viral infection (group II), and 35 with JRA (group III). Mean PCT levels were significantly higher in group I than in group II or group III (P<0.05). Mean CRP levels were significantly higher in group I than in group II (P<0.05); however, mean CRP levels were not significantly higher in group I than in group III (P>0.05). Using a cutoff of 0.5 ng/mL for PCT and 8 mg/L for CRP, sensitivity and specificity in distinguishing between group I and the other groups were 60.0% and 92.3% for PCT and 60.0% and 40.1% for CRP, respectively. Positive and negative predictive values were 42.9% and 96.0% for PCT and 10.0% and 92.6% for CRP, respectively. Conclusion : Measurement of PCT concentrations appears to be more useful than CRP for distinguishing between bacterial infection and non-bacterial diseases in children.

Studies on Storage Characteristics of Tofu with Herb (허브첨가 두부의 저장 특성)

  • Jeon, Mi-Kyung;Kim, Mee-Ra
    • Korean journal of food and cookery science
    • /
    • v.22 no.3 s.93
    • /
    • pp.307-313
    • /
    • 2006
  • Tofu was prepared with various herbs (green tea, rosemary, lavender and thyme) and the tofu quality was investigated during storage. In the measurement of tofu color, the L and b values increased during storage period. Especially, the b value was very high at 8 days after storage. The pH value of tofu increased until 6 days of storage, but then decreased. The turbidity gradually increased until 6 days of storage and rapidly increased at 8 days of storage. The microorganism count of herb tofu was lower an that of control tofu during storage. Especially green tea tofu showed the lowest psychrotrophic microorganism count as $1.3{\times}10^8\;CFU/g$. In addition, lavender tofu showed the lowest aerobic mesophilic microorganism count $(2.0{\times}10^7\;CFU/g)$ at 8 days of storage. In texture analysis, hardness and chewiness of herb tofu increased with increasing storage period. Springiness increased to 2 or 4 days of storage but decreased after 6 or 8 days. Therefore, herb tofu is expected to have good quality physiologically as well as microbiologically.

Evaluation of TOF MR Angiography and Imaging for the Half Scan Factor of Cerebral Artery (유속신호증강효과의 자기공명혈관조영술을 이용한 뇌혈관검사에서 Half Scan Factor 적용한 영상 평가)

  • Choi, Young Jae;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.3
    • /
    • pp.92-98
    • /
    • 2016
  • To aim of this study was to assess the full scan and half scan of imaging with half scan factor. Patients without a cerebral vascular disease (n = 30) and were subject to the full scan half scan, and set a region of interest in the cerebral artery from the three regions (C1, C2, C3) in the range of 7 to 8 mm. MIP (maximum intensity projection) to reconstruct the images in signal strength SNR (signal to noise ration), PSNR (peak signal noise to ratio), RMSE (root mean square error), MAE (mean absolute error) and calculated by paired t-test for use by statistics were analyzed. Scan time was half scan (4 minutes 53 seconds), the full scan (6 minutes 04 seconds). The mean measurement range (7.21 mm) of all the ROI in the brain blood vessel, was the SNR of the first C1 is completely scanned (58.66 dB), half-scan (62.10 dB), a positive correlation ($r^2=0.503$), for the second C2 SNR is completely scanned (70.30 dB), half-scan (74.67 dB) the amount of correlation ($r^2=0.575$), third C3 of a complete scan SNR (70.33 dB), half scan SNR (74.64 dB) in the amount of correlation between the It was analyzed with ($r^2=0.523$). Comparative full scan with half of SNR ($4.75{\pm}0.26dB$), PSNR ($21.87{\pm}0.28dB$), RMSE ($48.88{\pm}1.61$), was calculated as MAE ($25.56{\pm}2.2$). SNR is also applied to examine the half-scans are not many differences in the quality of the two scan methods were not statistically significant in the scan (p-value > .05) image takes less time than a full scan was used.

Determination of optimum gamma ray range for radiation mutagenesis and hormesis in quinoa (Chenopodium quinoa Willd.)

  • Park, Chan Young;Song, Seon Hwa;Sin, Jong Mu;Lee, Hyeon Young;Kim, Jin Baek;Shim, Sang In
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.240-240
    • /
    • 2017
  • Quinoa (Chenopodium quinoa Willd.) is one of the ancient crops cultivated in the Andes region at an altitude of 3,500-4000m in Chile and Bolivia from 5000 BC. It contains a large amount of protein, minerals and vitamins in comparison with other crops. The cultivation area has been increasing worldwide because of its excellent resistance to various abiotic stress such as salinity, drought and low temperature. ${\gamma}$-Ray radiation of high dose is often used as a tool to induce mutations in plant breeding, but it has a deleterious effect on organisms. However, the radiation may have a positive stimulatory effect of 'hormesis' in the low dose range. This experiment was carried out to investigate the optimum dose range for creating the quinoa genetic resources and to investigate the hormesis effect at low dose on the quinoa. This experiment was performed for 120 days from November, 2016 to February, 2017 in the greenhouse of Gyeongsang National University. ${\gamma}$-Ray radiation was irradiated to seeds at 0 Gy, 50 Gy, 100 Gy, 200 Gy, 300 Gy, 400 Gy, 600 Gy, 800 Gy and 1000 Gy for 8 hours. (50 Gy) using the low level radiation facility ($Co^{60}$) of Cooperative Research Institute of Radiation Research Institute, KAERI. Fifty seeds were placed on each petri dish lined with wet filter paper and germination rate was measured at a time interval of 2 hours for 40 hrs. The length of the root length was measured one week after germination. Each treatment was carried out in 3 replicates. The growth of seedlings were investigated for 10 days after transplanting of 30 day-old seedlings. The plant height, NDVI, SPAD, Fv/Fm, and panicle weight were measured. The germination rate was highest at 50Gy and 0Gy and the rate of seeds treated with 400Gy or higher rate decreased to 25% of the seeds treated with 50Gy. The emergence rate of seedling in pot experiment was higher at the dose of 200 Gy, 300 Gy and 400 Gy than at 0 and 50Gy. However, the rate was lower at strong radiation higher than 600Gy at which $1^{st}$ leaf was not expanded fully and dead due to extreme overgrowth at 44 days after treatment (DAT). The highest value of panicle weight was observed at 50Gy (6.15g) and 100Gy (5.57g). On the other hand, the weight at high irradiated dose of 300Gy and 400Gy was decreased by about 55% compared to low dose (50 Gy). NDVI measurement also showed the highest value at 50 Gy as the growth progressed. SPAD was the highest at 400 Gy and showed positive correlation with irradiation dose except 0 Gy. Fv/Fm was high at 50 Gy up to 30 DAT and no difference between treatments was observed except for 400 Gy from 44 DAT. The plant height was the highest in 50Gy during the growing period and was higher in the order of 50Dy, 100Gy, 0Gy, 200Gy, 300Gy and 400Gy in 88 DAT. In this experiment, the optimal radiation dose for hormesis was 50Gy and 100Gy, and the optimal radiation dose for mutagenesis seems to be 400 Gy.

  • PDF

Comparison of Passive Diffusional Organic Vapor Samplers with Charcoal Tubes for the Measurement of Mixed Organic Solvents (확산형 포집기와 활성탄관을 이용한 공기중 혼합 유기용제 측정에 관한 연구)

  • Ahn, Kyu-Dong;Yeon, You-Yong;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.127-136
    • /
    • 1994
  • Diffusional sampling devices offer many advantages for measuring concentration levels of industrial contaminants than the conventional pump and charcoal tubes because they are lightweight, require no power, pump or tubing. This study designed to evaluate and compare the sampling performance of passive sampler to charcoal tube from mixed organic solvent workplace with 181 organic solvent using workers working in different concentration of organic solvents. All study workers kept both devices in their breathing zone simultaneuosly in the workplaces, and the sampling analytical results were compared with those of charcoal tube. The results obtained are as follows: 1. The concentrations of toluene and xylene measured by passive sampler were slightly higher than those of charcoal tube, but there were no significant statistical differences between two methods. 2. The concentrations of MEK and cyclo-hexanone measured by passive sampler in low exposure workplace (below 0.20 of MEK TLV levels and 0.1 of cyclo-hexanone TLV levels) were about 2 times higher than that of charcoal tube sampling. While, absorption efficiency of passive sampler was reduced according to increasing concentration measurements of MEK and cyclo-hexanone in air. 3. The ratios of concentrations of toluene, xylene, MEK and cyc1o-hexanone measured by passive sampler over those measured by charcoal tube were 1.11, 1.07, 1.63 and 3.65 respectively. 4. The percentages of concentration of passive samplers within 0.75 and 1.25 of charcoal tube value as a reference value of 1.0 were 57% in toluene, 74% in xylene, 34% in MEK and 32% in cyclo-hexanone respectively. 5. The correlation coefficients of toluene, xylene, MEK and cyclo-hexanone between passive sampler and charcoal tube sampler were 0.963, 0.957, 0.943 and 0.562 with statistical significance.

  • PDF

Soluble Interleukin-2 Receptor(sIL-2R) Levels in Patients Tuberculous Pleurisy VS Nontuberculous Pleurisy (결핵성 늑막삼출과 비결핵성 늑막삼출에서의 가용성 Interleukin-2 수용체의 농도)

  • Lim, Hyun-Oak;Ham, Jong-Yeol;Shim, Dae-Seok;Hwang, Young-Sil
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.2
    • /
    • pp.135-143
    • /
    • 1994
  • Background: The cell mediated immunity has an important role in the pathogenesis of tuberculosis. sIL-2R has been known as a sensitive marker of T lymphocyte activation Elevated serum levels of sIL-2R have been found in patients with lymphoproliferative disorders, organ transplantation, autoimmune diseases, and various granulomatous diseases. Elevated levels of sIL-2R have been also found in the serum and pleural fluid of the patients with tuberculosis. To evaluate the diagnostic value of sIL-2R in the differentiation of tuberculous pleurisy and nontuberculous pleurisy. We measured the level of sIL-2R in the sera and pleural fluids of 12 patients with tuberculous pleurisy and 32 patients with nontuberculous pleurisy. Method: Samples of pleural fluid and serum were centrifuged at 2500 rpm for 10 min to remove cell pellets. Soluble IL-2R was measured with a sandwitch enzyme immunoassay using the Cellfree(r) Interleukin-2 Receptor Test kit(T-cell science,Inc. Cambridge, MA). Results: The results obtained were as follows: 1) The sIL-2R level in pleural fluid of the patients with tuberculous pleurisy was higher than that of patients with nontuberculous pleurisy(P<0.005). 2) When the sIL-2R level above 5,000 u/ml in pleural fluid was used as the cut-off value to diagnose tuberculous pleurisy, it had a sensitivity of 84.6% and a specificity of 90.9%. 3) The sIL-2R level in the sera of the patients with tuberculous pleurisy was higher than that of patients with bacterial pleural effusions and normal control group(P<0.05) and there was no difference of levels compared with malignant pleural effusions and transudative pleural effusions(P>0.05). 4) In patients with tuberculous pleurisy, the mean concentration of sIL-2R in pleural fluid was higher than that in serum(P<0.005). Conclusion: These findings suggest that the measurement of elevated levels of pleural fluid sIL-2R in tuberculous pleurisy may be useful in the differential diagnosis between patients with tuberculous pleurisy and nontuberculous pleurisy.

  • PDF

SURFACE CHANCE OF EXTERNAL HEXAGON OF IMPLANT FIXTURE AND INTERNAL HEXAGON OF ABUTMENT AFTER REPEATED DELIVERY AND REMOVAL OF ABUTMENT (지대주의 반복적인 착탈에 따른 임플랜트 고정체의 external hexagon과 지대주 internal hexagon의 변화에 관한 연구)

  • Jung Seok-Won;Kim Hee-Jung;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.528-543
    • /
    • 2005
  • Statement of problem: Repeated delivery and removal of abutment cause some changes such as wear, scratch or defect of hexagonal structure. It may increase the value of rotational freedom(RF) between hexagonal structures. Purpose: The purpose of this study was to evaluate surface changes and rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment after repeated delivery and removal under SEM and toolmaker's microscope. Materials and methods: Implant systems used for this study were 3i and Avana. Seven pail's of implant fixture, abutment and abutment screws for each system were selected and all fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. Each one was embedded beneath the platform of fixture. Surfaces of hexagonal structure before repeated closing and opening of abutment were observed using SEM and rotational freedom was measured by using toolmaker's microscope. Each abutment was secured to the implant future by each abutment screw with recommended torque value using a digital torque controller and was repeatedly delivered and removed by 20 times respectively. After experiment, evaluation for the change of hexagonal structures and measurement of rotational freedom were performed. Result : The results were as follows; 1. Wear of contact area between implant fixture and abutment was considerable in both 3i and Avana system. Scratches and defects were frequently observed at the line-angle of hexagonal structures of implant fixture and abutment. 2. In the SEM view of the external hexagon of implant fixture, the point-angle areas at the corner edge of hexagon were severely worn out in both systems. It was more notable in the case of 3i systems than in that of Avana systems. 3. In the SEM view of the internal hexagon of abutment, Gingi-Hue abutment of 3i systems showed severe wear in micro-stop contacts that were machined into the corners to prevent rotation and cemented abutment of Avana systems showed wear in both surface area adjacent to the corner mating with external hexagon of implant fixture. 4 The mean values of rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment were 0.48$\pm$0.04$^{\circ}$ in pre-tested 3i systems and 1.18$\pm$0.25$^{\circ}$ after test, and 1.80$\pm$0.04$^{\circ}$ in pre-tested Avana systems and 2.61$\pm$0.16$^{\circ}$ after test. 5. Changes of rotational freedom after test shouted statistical)y a significant increase in both 3i and Avana systems(P<0.05, paired t-test). 6. Statistically, there was no significant difference between amount of increase in the rotational freedom of 3i systems and amount of increase in that of Avana ones(P>0.05, unpaired t-test). Conclusion: Conclusively, it was considered that repeated delivery and remove of abutment by 20 times would not have influence on screw joint stability. However, it caused statistically the significant change of rotational freedom in tested systems. Therefore, it is suggested that repeated delivery and remove of abutment should be minimal as possible as it could be and be done carefully Additionally, it is suggested that the means or treatment to prevent the wear of mating components should be devised.

Estimation of Glomerular Filtration Rate(GFR) Using $^{99m}Tc$-DTPA Renal Scan and the Parameters for Renal Function ($^{99m}Tc$-DTPA를 이용한 신장스캔에서 사구체 여과율의 측정방법과 영상분석에서 구한 지표들에 의한 신장기능의 평가)

  • Cho, Ihn-Ho;Yoon, Hyun-Dae;Won, Kyu-Chang;Lee, Chan-Woo;Lee, Hyoung-Woo;Lee, Hyun-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.11 no.1
    • /
    • pp.101-108
    • /
    • 1994
  • Many previously described nuclear medicine procedures to assess glomerular filtration rate have some problems because numerous blood sample is to be taken and they don't measure each separate renal function. Gates described isotopic method for the measurement of global and unilateral GFR based on the fractional renal uptake of $^{99m}Tc$-DTPA 2 to 3 minutes after its intravenous injection. We evaluated GFR using $^{99m}Tc$-DTPA in 57 people according to Gates method and compared with creatinine clearance. A good correlation was observed between creatinine clearance and GFR calculated by Gates' formula with an r value of 0.9(P<0.05). And also the relationship between parameters of $^{99m}Tc$-DTPA renal scan images and GFR was taken. They were significantly correlated with GFR calculated by Gates' formula : r value 0.66 between relative intensity of peak renal to peak aortic activity(pK/pA) and GFR, -0.42 between time between aortic and kidney peak(A-K) and GFR and -0.48 between parenchymal renal activity at 25 min compared to peak kidney activity(25K/pK) and GFR. In conclusion, the determination of GFR according to the Gates' formula shows good and reproducible of GFR with rapidity and simplicity. And the parameters from the renal scan images can use to estimate the renal function.

  • PDF

Diastolic Function in Patients with Hypertrophic Cardiomyopathy: Evaluation Using the Phase-contrast MRI Measurement of Mitral Valve and Pulmonary Vein Flow Velocities (비대성심근증 환자의 이완기능평가: 승모판과 폐정맥 유속을 측정한 위상차 MRI의 이용)

  • Kim, Eun Young;Choe, Yeon Hyeon;Kim, Sung Mok;Lee, Sang-Chol;Chang, Sung-A;Oh, Jae K.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.4
    • /
    • pp.314-322
    • /
    • 2014
  • Purpose: Diastolic dysfunction is a common problem in patients with hypertrophic cardiomyopathy (HCM). The purpose of this study was to assess the role of MRI in the assessment of diastolic function using mitral valve and pulmonary vein flow velocities in HCM patients. Methods and Results: Phase-contrast MRI (mitral valve and pulmonary vein) and transthoracic echocardiography was successfully performed for 59 HCM patients (44 men and 15 women; mean age, 51 years). Forty-nine patients had a diastolic dysfunction; grade 1 (n = 20), grade 2 (n = 27), and grade 3 (n = 2) using echocardiography, and ten patients had normal diastolic function. The transmitral inflow parameters (E, A, and E/A ratios) obtained by MRI showed positive correlation with the same parameters measured by echocardiography (Pearson's r values were 0.47, 0.60, and 0.75 for E, A, E/A, respectively, all P < 0.001). With the flow information of the pulmonary vein from cardiac MRI, pseudo-normalized pattern (n = 8) could be distinguished from true normal filling pattern (n = 17), and the diastolic function grades by cardiac MRI showed moderate agreement with those of echocardiography (kappa value = 0.45, P < 0.001). Conclusions: Assessment of left ventricle diastolic function is feasible using phase-contrast MRI in HCM patients. Analysis of pulmonary vein flow velocity on MRI is useful for differentiating pseudo-normal from normal diastolic function in HCM patients.

Evaluation of Renal Oxygenation in Normal Korean Volunteers Using 3.0 T Blood Oxygen Level-Dependent MRI (3.0 T 혈중산소치의존 자기공명영상을 이용한 정상한국인에서의 신장 산소공급의 평가)

  • Hwang, Sung Il;Lee, Hak Jong;Chin, Ho Jun;Chae, Dong-Wan;Na, Ki Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.1
    • /
    • pp.19-25
    • /
    • 2013
  • Purpose : Renal blood oxygen level-dependent (BOLD) MRI has been used in the evaluation of renal oxygenation. We tried to provide the normal $R2^*$ value of the human kidney with 3.0 T, and evaluated the differences in $R2^*$ values according to gender and location. Materials and Methods: Twenty-four healthy volunteers underwent BOLD MRI at 3.0 T. Multi gradient echo-echo planar imaging sequence with seventeen echoes was used. After generation of the $T2^*$ map, the $R2^*$ was calculated. The statistical differences in $R2^*$ values between the cortex and medulla, males and females, and the right and left kidney were analyzed. The regional differences of $R2^*$ within the both kidneys were evaluated respectively. Results: BOLD MRI was successful in all participants. No gross artifact interfered with $R2^*$ measurement. The mean $R2^*$ at 3.0 T was $17.1{\pm}2.60s^{-1}$ in the cortex and $27.7{\pm}4.83s^{-1}$ in the medulla (p < 0.001). The $R2^*$ value in the medulla was significantly higher in the male than female volunteers (p = 0.025). There were no statistical differences of $R2^*$ according to the side and location in the kidney (p = 0.197). Conclusion: Renal BOLD MRI can be efficiently performed with 3.0 T MRI. Renal medullary hypoxia is present in normal volunteers. Our results may be used as reference values in the evaluation of pathologic conditions using BOLD MRI.